08-985-023
ELECTRICAL SYMBOL LEGEND ABBREVATIONS/SUFFIXES A.F.F. ABOVE FINISHED FLOOR A.F.G. ABOVE FINISHED GRADE BD. BOARD C. CONDUIT CAB. CABINET C.B. CIRCUIT BREAKER CKT. CIRCUIT E.C. EMPTY CONDUIT E.W.C. ELECTRIC WATER COOLER F.A. FIRE ALARM G.F.I. GROUND FAULT INTERRUPTER GND. GROUND HID NIGH INTENSITY DISCHARGE PPS HIGH PRESSURE SODIUM I.G. ISOLATED GROUND LT. LIGHT LTG. LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY MT. MOUNT MTG. HT. MOUNTING HEIGHT N.E.C. NATIONAL ELECTRICAL CODE N.I.C. NOT IN CONTRACT P.A. PUBLIC ADDRESS PNL. PANEL RECEPT. RECEPTACLE S.D.B.C. SOFT DRAWN BARE COPPER SW. SWITCH U.O.N. UNLESS OTHERWISE NOTED V.P. VAPOR PROOF W.P. WEATHER PROOF (NEMA 3R ENCLOSURE) X.P. EXPLOSION PROOF (CLASS TO MEET N.E.C.) (ALL SYMBOLS MAY NOT BE USED) DATA AND COMMUNICATIONS 0 TELEPHONE E DATA OUTLET (4'X 4'X 2 1/2' OUTLET BOX) (18' A.F.F.) PROVIDE 3/4' STUB OUT CONDUIT 6' ABOVE CEILING. 0 DATA OUTLET (4'X 4'X 2 1/2' OUTLET BOX)(18' A.F.F.) PROVIDE 3/4' STUB OUT CONDUIT 6' ABOVE CEILING. AT RAISED FLOOR AREA PROVIDE A 3/4' CONDUIT STUB OUT 4' UNDER RAISED FLOOR. ® TELEPHONE OUTLET (4'X 4'X 2 1/2' OUTLET BOX) (18' A.F.F.) PROVIDE 3/4' STUB OUT CONDUIT 6' ABOVE CEILING. ®w WALL MOUNTED TELEPHONE OUTLET (60'A.F.F.) 0 MONITOR DATA OUTLET Tv TELEVISION OUTLET (80' A.F.F.) U.O.N. ® PA SPEAKER 0 TERMINAL CABINET - TYPE INDICATED TELEPHONE TERMINAL BACK BOARD Cam] CCTV CAMERA CLOCK OUTLET (2'X4'X2' OUTLET BOX) (83.5' A.F.F. OR ON TOP © OF THE DOOR FRAME) PROVIDE 1/2' STUB OUT CONDUIT 6' ABOVE CEILING TO CLOCK SYSTEM. POWER EQUIPMENT HIGH VOLTAGE DISTRUBUTION PANELBOARD 277/480V ® LOW VOLTAGE DISTRUBUTION PANELBOARD 120/208V ® HIGH VOLTAGE PANELBOAl2D 277/48OV. _ LOW VOLTAGE PANELBOAl2D 120/208V. UT TRANSFORMER FIRE ALARM DEVICES � F FIRE ALARM STROBE LIGHT - 75 CANDELA MIN. - (80 ' A.F.F.) PB POWER SUPPLY OS E F/A SPEAKER (TIE TO EXISTING SYST.) ® F/A SMOKE DETECTOR (TIE TO EXISTING SYST.) ® F/A DUCT SMOKE DETECTOR (TIE TO EXISTING SYST.) E4 FIRE ALARM STROBE LIGHT / CHIME. (80' A.F.F.) ❑F FIRE ALARM PULL STATION (48' A.F.F.) 0 TERMINAL CABINET - TYPE INDICATED LIGHTING FIXTURES OLIGHTING FIXTURE IDENTIFICATION. SEE SCHEDULE O HID OR FLUORESCENT DOWN LIGHT Q-f= RECESSED / LAY -IN MOUNTED FLUORESCENT LIGHT FIXTURE ® PENDANT FLUORESCENT LIGHT FIXTURE FLUORESCENT STRIP 0 RECESSED MOUNTED/FLUORESCENT LIGHT FIXTURE ON EMERGENCY LIGHT LIFE SAFETY CIRCUIT. Os® RECESSED MOUNTED/FLUORESCENT LIGHT FIXTURE ON EMERGENCY LIGHT CRITICAL CIRCUIT. 0 RECESSED MOUNTED FLUORESCENT LIGHT FIXTURE ON EMERGENCY LIGHT CRITICAL CIRCUIT O RECESSED MOUNTED INCANDESCENT LIGHT FIXTURE ON EMERGENCY LIGHT CRITICAL CIRCUIT ® EXIT LIGHT (-I WALL MOUNTED EXIT LIGHT SHADED QUADRANT INDICATES NUMBER OF FACES. ARROWS AS SHOWN OR REQUIRED. WIRING BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICKS INDICATES 2 tt 12 CONDUCTORS E I tt 12 GROUND IN 3/4' CONDUIT TICK MARKS WHEN SHOWN INDICATES NUMBER OF tt 12 CONDUCTORS IF OTHER THAN THREE, (1) INDICATES GROUND. CONDUIT LARGER THAN 3/4' E CONDUCTOR LARGER THAN tt 12 SHALL BE AS INDICATED. HOME RUN TO PANEL 'A' = PANEL DESIGNATION, 13,5 = CIRCUIT NUMBERS. U.O.N. A 1,3,5 MINIMUM SIZE OF 3/4'C . `j� FLEXIBLE CONDUIT CONDUIT RUN CONCEALED IN CEILING OR WALLS — — CONDUIT RUN UNDERGROUND OR IN SLAB CONDUIT RUN EXPOSED C CAPPED CONDUIT —�—�— SYSTEM AND/OR EQUIPMENT GROUNDING CONDUCTOR GROUNDING ELECTRODE E CONDUCTOR SYSTEM — S CONDUIT SEAL —CT — CABLE TRAY WIRING DEVICES DUPLEX RECEPT - NORMAL POWER 20 AMP NEMA 5-20R (18' A.F.F.) ` p DUPLEX RECEPT - CRITICAL POWER 20 AMP NEMA 5-20R 18' A.F.F. (COLOR RED) SINGLE RECEPT - 20 AMP NEMA 5-20R (18' A.F.F.) DUPLEX RECEPT. NORMAL PWR MOUNTED ABOVE COUNTER - 20 AMP NEMA 5-202 (44' A.F.F.) U.O.N. QUAD - PLEX RECEPT - 20 AMP NEMA 5-20P (18' A.F.F.) ® DUPLEX RECEPT ABOVE CEILING MOUNTED JO JUNCTION BOX WALL MOUNTED JUNCTION BOX a DATA/PPONE JUNTION BOX FLOOR MOUNTED JUNCTION BOX UNDER RAISED FLOOR FOR CONNECTION TO WIREMOLD PLUG STRIP MOUNTED AT RACKS AND FURNITURE BY A HARDWIRE FLEXIBLE CONNECTION BY ELECTRICAL CONTRACTOR. N PULL BOX FB FLOOR BOX E" WIREMOLD PLUG STRIP WITH 4-20 AMP OUTLETS 48' LOND U.O.N. S SINGLE POLE SWITCH - 20 AMP (48' A.F.F.) S3 THREE WAY SWITCH - 20 AMP (48' A.F.F.) So DIMMER SWITCH 2O00 WATTS 48' A.F.F.) VAV BOX PROVIDE POWER FOR CONTROL PROJECT: AU BON PAN RESTAURANT- SOUTH MIAMI HOSPRAL CLIENT NAYA ARCHrrECTS JOB No: 18001 LIGHTING FIXTURE SCHEDULE MANUFACTURER & CATALOG Na LAMPS RXTURE TYPE (OR APPROVED EQUIVALENT) MOUNTING REMARKS SERVICE TOTAL NO. TYPE WAS VOLTS WATTS LIGHTOLIER [ 1 ] [ 2 ] ® RECESSED 3 F32T8 / 41 32 277 88 SPS2GRAVA332 © LIGHTOLIER RECESSED 3 F17T8 / 41 17 277 59 [ 1 ] [ 2 ] SPS2GRAVA317 REMARKS: 1. PROVIDE ENERGY SAVING BALLAST AND LAMPS. 2. PROVIDE ELECTRONIC BALLAST TOALL FLOU RESCENT FIXTURE. CONDUIT AND BOXES COLOR CODE CHART ORANGE - CRITICAL BRANCH YELLOW - LIFE SAFETY BRANCH GREEN - EQUIPMENT BRANCH RED - FIRE ALARM PROJECT SPECIFICATION I. SITE INVESTIGATION: PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE AND BECOME ACQUAINTED WITH ALL OF THE EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITION RESULTS IN EXTRA MATERIAL OR LABOR. THE CONTRACTOR SHALL SUBMIT IN HIS BID AN AMOUNT THAT WOULD BE SET ASIDE FOR UNIDENTIFIED ITEMS. 2. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE ELECTRICAL SYSTEMS, ALL IN ACCORDANCE WITH THESE CONSTRUCTION DOCUMENTS. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2004 W/ 2006 REVISION AND ALL THE STANDARDS OF CONSTRUCTION ESTABLISHED BY THE SOUTH MIAMI HOSPITAL INCLUDING, BUT NOT LIMITED TO THE FOLLOWING PUBLICATIONS: A) CHAPTER 59A-3 FLORIDA ADMINISTRATIVE CODE 2002, B) NFPA 70 -2005, NFPA 72-2002, NFPA 99-2002, NFPA 101-2003 AND C) OSHA. 3. MINIMUM STANDARDS: THE MATERIAL, EQUIPMENT, INSTALLATIONS, AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM AT LEAST TO THE REQUIREMENTS OF THE REGULATING AGENCIES AS LISTED IN ITEM (2) ABOVE. ALL MATERIALS AND EQUIPMENT USED SHALL BE LISTED OR BEAR THE U.L. APPROVAL FOR THEIR INTENDED USE. 4. RESPONSIBILITIES: CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE INSTALLATION OF THE RACEWAY SYSTEM, EQUIPMENT AND WIRING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 5. GUARANTEE: THE CONTRACTOR/SUB-CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AND THAT HE WILL AT HIS OWN EXPENSE, REPAIR OR REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 6. ALL EQUIPMENT, SYSTEM AND SYSTEM COMPONENTS SHALL BE FROM THE SAME MANUFACTURER AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 7. RACEWAYS AND FITTINGS: CONDUIT RUNS SHALL BE CONCEALED IN CEILING SPACES, AND WALL PARTITIONS, NO RACEWAY SHALL BE EXPOSED IN INTERIOR SPACES SUCH AS RESIDENT ROOMS. CONCEALED CONDUITS MAY BE EMT. THE MINIMUM CONDUIT SIZE IS TO BE 3/4' FOR HOME RUN. ALL CONDUITS AND RACEWAYS SHALL BE METAL. 8. CONDUCTOR: ALL CONDUCTOR WIRE AND CABLE SHALL CONSIST OF 98 % CONDUCTIVITY COPPER. ALL CABLES SHALL BE SINGLE CONDUCTOR, 600 VOLT, THERMOPLASTIC INSULATION. SUITABLE FOR CONTINUOUS OPERATION AT 75 DEGREES C. CONDUCTOR TEMPERATURE IN BOTH WET AND DRY LOCATIONS. THESE CABLES SHALL BE N.E.C. INSULATION CLASSIFICATION TYPE THWN/TP N. MINIMUM SIZE SHALL BE tt12. ALL CONDUCTOR INSTALLATION SHALL BE COLOR CODED MAINTAINING THE INTEGRITY OF THE EXISTING INSTALLATION. COLORED INSULATION SHALL BE USED FOR AWG SIZES tt10 AND SMALLER AND APPROVED COLOR TAPES SHALL BE USED FOR AWG SIZES 1:8 AND LARGER ALL POWER AND CONTROL CIRCUITS SHALL CARRY EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC 250-95. 9. THE NATURE OF THIS TYPE OF CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEERS AS WELL AS THE CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEERS TO SHOW AND VERIFY WHERE POSSIBLE. THE LOCATION OF THE EXISTING ELECTRICAL SYSTEMS. THE MAJOR PORTION OF THE ELECTRICAL SYSTEMS ARE AS SHOWN ON THE DRAWINGS. HOWEVER MINOR DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. NO ADVANTAGE IS TO BE TAKEN BY THE CONTRACTOR BECAUSE THESE MINOR DIFFERENCES. 10. ALL FLOORS, WALLS, AND ROOF PENETRATIONS SHALL BE PROPERLY SEALED -OFF. IF FIRE RATED, AN APPROVED FIRE RETARDANT SEALANT SHALL BE USED. II. THESE DRAWINGS ARE A GUIDE FOR THE INSTALLATION OF THE RACEWAY SYSTEM AND EQUIPMENT. THEY ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND PARTLY DIAGRAMMATIC. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A COMPLETE AND FUNCTIONAL INSTALLATION. 12. ANY DEVIATIONS FROM THESE DRAWINGS AND SPECIFICATIONS MUST BE AUTHORIZED IN WRITING FROM THE ENGINEERS OFFICE. THE CONTRACTOR SHOULD BE HELD LIABLE FOR ANY DEVIATIONS WITHOUT SUCH AUTHORIZATION. 13. ANY WORK NOT SHOWN OR SPECIFICALLY MENTIONED ON THESE PLANS AND/OR SPECIFICATIONS BUT CONSIDERED NECESSARY FOR COMPLETION OF THE WORK IN THE PROPER MANNER SHALL BE PROVIDED BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGE. 14. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. ELECTRICAL CONTRACTOR TO COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF ALL OUTLETS, (LIGHTS, RECEPTACLES, SWITCHES, PULL BOXES, ETC.) FOR EXACT LOCATION. 15. ALL ELECTRICAL EQUIPMENT SUCH AS PANELS, PULUJ-BOXES, FEEDERS, BREAKERS, ETC. SHALL BE PROPERLY IDENTIFIED WITH A PERMANENT LABEL AFFIXED TO THE EQUIPMENT. IDENTIFY BREAKERS IN PANELS BY MEANS OF A TYPED, PLASTIC COVERED DIRECTORY. CONTRACTOR SHALL PROVIDE UPDATED PANEL DIRECTORIES. 16. ALL SERVICE INTERRUPTIONS AND ALL REMOVAL AND DISPOSAL WORK SHALL BE SCHEDULED AND COORDINATED WITH THE AUTHORIZED REPRESENTATIVE OF THE OWNER. 17. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS AND OTHER ITEMS AS REQUIRED FOR THE WORK AS OUTLINED IN THE PLANS. PROVIDE ALL THE REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 18. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF PRINTS FOR INDICATING ALL CHANGES AS THE CONSTRUCTION PROGRESSES. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL DELIVER A SET OF 'AS -BUILT' DRAWINGS TO THE OWNER IN REPRODUCIBLE MATERIAL. CONTRACTOR SHALL STAMP 'AS -BUILT' ON THE PLANS, (EACH SHEET), AND PRINT, DATE AND SIGN IN INK. 19. CONVENIENCE RECEPTACLE LIGHTING SWITCHES AND WIRING DEVICES SHALL BE ENGRAVED INDICATING PANEL AND CIRCUIT NUMBERS. Revisions: A 0 0 0 L M Q o O N LL � O o .Mi J� LA_ Q Q z_ ~0 �J0 LIJ O m z QQ Q �J Q I=- U z0 LLJ �Wto � MO W N coo 3 Vi o Q C U) co N_ O , fn CE O N m U 0 0 � " n �•=u00 � E '� �< rr .—N.3 < d b cn ch uj U N v J z U g u. W LJ 0 zo LJ Q = U LJ (f) Z I_,_, Q W cl, U =D 0::� C:) x U z ,L w III� U LLJ _z 00 m cn DRAWN: JB CHECKED: E5 DATE: 02-18-m8 SCALE: A5 NOTED • �LE I�IQ�Lr J';r `L ;, A,' Q , .171E Sheet No. E0.00 JOB # 21033