08-985-021#NEAT 1 NOT W SUPPL' P E T P diby� ELECTRIC WAT HUNG FROM JC NIGH AS POSSI DRAIN V SAFET' 1 1/2* MII DEPTH SHUT-OFF GATE VALVE COLD WATER SUPPLY TO NEATER PROVIDE 2 GAL. THERMAL EXPANSION TANK 3/4'PET RELIEF LINE PROVIDE AIR GAP FITTING IF TERMINATING OUTSIDE ROOM. 3/4' PAN �U TERMINATE 11/2' OVER DRAIN LINE SERVICE SINK FLOOD RIM LEVEL OR EXTEND TO THE EXTERIOR OF THE BUILDING AND TERMINATE POINTING DOWN 6' ABOVE FINISHED GRADE. NO ADDITIONAL HEAT TRAPS REQUIRED WHEN WATER HEATER HAS INTEGRAL HEAT TRAPS. TYPICAL WATER HEATER DETAIL N.T.S. COVER SECURED WITH SCREWS THREADED C.O. PLUG FIN. GRADE 4 X 6' DIA. CONCRETE PAD FLUSH W/FIN. GRADE SLIP JOINT EXTERIOR TYPE TYPICAL CLEANOUT DETAIL N.T.S. F System No. C-AJ-1156 F Rating -- 3 Hr T Rating — 0 Hr L Rating At Ambient -- Less Than 1 CFM/sq ft L Rating At 400 F -- 4 CFM/sq ft AM 11 InrAM C /N^1 I An ��A FLOOR 1. Floor or Wall Assembly -- Min 4-1/2 in. thick reinforced lightweight or normal weight (100 to 150 pc) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 27 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Steel Pipe -- Nom 21 in. diam (or smaller) 0.056 in. thick (or heavier) steel pipe. One pipe to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. (point contact) to max 3 in. Pipe to be rigidly supported on both sides of floor or wall assembly. 3. Firestop System -- The firestop system shall consist of the following: A. Steel Wire Mesh -- (Not Shown) -- Where needed to aid in system installation in concrete block wall construction, No. 8 steel wire mesh or min 0.034 in. thick (20 MSG) galv sheet steel may be formed, centered and installed within the through opening such that it is recessed a min of 1/8 in. from each surface of the wall. B. Packing Material -- Min 2 in. thickness of min 4.0 pcf mineral wool bait insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material. C. Fill, Void or Cavity Material* -- Sealant - Min 3/4 in. thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. At the point contact location between pipe and concrete, a min 1/2 in. diam bead of caulk shall be applied at the concrete/pipe interface on the top surface of floor and on both surfaces of wall. HILT] CONSTRUCTION CHEMICALS, DIV OF HILTI INC - FS-ONE Sealant *Bearing the UL Classification Mark 1/2' MIN. FLUSH VALVE LEFT OR RIGHT AS APPLICABLE (CONTR'S OPTION) FIXTURE WALL HUNG OR FLOOR MTD. AS APPLICABLE DRAIN FINISH FLOOR NON-FERROUS ZOOM SLOPE DOWN TO OUTLET a 1/87FT WJ NO TRAP OR INTERMEDIATE LOW POINTS. Z ALTERNATE CONN. (CONTIZS. OPTION) SYSTEM DIAGRAM ALL EXPOSED COMPONENTS CHROME PLATED AND / OR STAINLESS STEEL (SLOAN F-72-AI) FLUSH VALVE TRAP PRIMER DETAIL (F.V.P., N.T.S. FACE OF WALL WALL STAINLESS STEEL COVER SCREWED TO THREADED C.O. PLUG. System No. W-L-1054 F Ratings -1 and 2 Hr (See Items 1 and 3) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/Sq Ft L Rating At 400 F - 4 CFM/Sq Ft SECTION A -A 1. Wall Assembly -- The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory. 2. Through -Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2-1/4 in. Pipe may be installed with continuous point contact. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -- Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 30 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. D. Copper Tubing - Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe - Nom 6 in. diam (or smaller) regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -- Sealant - Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe wall interface on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIVOF HILTI INC -- FS-One Sealant *Bearing the UL Classification Mark PLUMBING FIXTURE COLD WATER TO FIXTURE PIMER VALVE JOSAM tt88250-10 OR APPROVED EQUAL W/ VACUUM BREAKER. NOTE: ALL EXPOSED PLUMBING ITEMS, SHALL BE CHROME PLATED FLOOR DRAIN PARTITION OR CHASE C.W. SUPPLY TO PLUMBING FIXTURE FIXTURE VALVE ESCUTCHEON PLATES (SEAL PARTITION OPENINGS) FINISH FLOOR PENETRATION —pN. SLEEVE E SEAL AS REQUIRED 1/2' MIN. ALTERNATE BY LOCATION CONN'S. (CONTRACTORS (REFER TO OPTION) SLOPE DR TO DETAIL) TRAP PRIMER N.T.S. PERFORATED VENT CAP 12' MIN ABOVE TOP OF CD PAN OUTLET o 1/8' FT. W/ NO TRAP OR INTERMEDIATE LOW POINTS. NOTE USED WHERE NO SUITABLE WATER CLOSET, ELECTRIC WATER COOLER, OR DRINKING FOUNTAIN IS WITHIN 30 FEET. VALVE DETAIL (T.P.V.) C.O. PLUG CONNECTION A.H.U. UNION �- AUXILIARY DRAIN PAN SLOPE 1/8'/ FT. TEE I I Q UNIT TYPE A B DRAW TNRU 2' PLUS X X BLOW TI-RU I' MIN. 2X WHERE 'X' = STATIC PRESSURE IN PAN. NOTES: A. SLOPE DRAIN LINE TO CONDENSATE RECEPTOR (MIN. 1/8' PER FOOT) B. DRAIN LINE SHALL BE COPPER TYPE 'L' AND INSULATED C. TSP = FAN TOTAL STATIC PRESSURE D. PROVIDE CONDENSATE OVERFLOW SAFETY SWITCH TO TURN OFF THE UNIT IF DRAIN PAN APPROACHES OVERFLOW. A/C CONDENSATE P-TRAP DETAIL N.T.S. ® Reproduced by HILTI, Inc. Courtesy of ��.SS I FiFo Underwriters Laboratories, Inc. FIRESTOP SYSTEMS December 4, 2002 C e L us W med Waste Lim Kftp Ouftt As +S`UAW4 As Pofttft 1i h At Leatat 114" Slops Per F*ot WCO Big Dipped iS Unit -Grei= 0440;9eii Conll;*+os GREASE TRAP SIZING CALCULATION FIXTURE # FIXTURES FIXTURE VALUE (GPM) TOTAL FIXTURE (GPM) AVERAGING MULTIPLIER FLOW RATING (GPM) 3 COMPARTMENT SINK 1 25 25 0.25 6.25 • CALCULATION BASED ON BIG DIPPER 'SIZING BIG DIPPER SYSTEMS IN FOOD SERVICE OPERATIONS' PHAMPLET. SINGLE FIXTURE BIG DIPPER EQUIPMENT MODEL GPM RATING W-150-IS 15 :1 �I0I4>;10Q;t 4 ;ONCRETE INSERT TNRU 8' PIPE SIZE J.L./F.M. APPROVED. GRINNE-LL FIG. !81/285 OR APPROVED EQUAL THREAD ROAD IPE RING ICK X 12' LONG SLEEVE PRENE FOAM (RUBATEX MRMFLEX) RING I' GREATER THAN O.D. IL, vrtiUGE X 12' LONG GALVANIZED STEEL PIPE SHIELD ;ONCRETE ANCHOR SELF DRILLING J.L. LISTED TNRU 4' PIPE SIZE -ROAD COUPLING, U.L./F.M. G12INNELL 136 OR APPROVED EQUAL ALL THREAD ROAD PE RING BEAM C TYPE CLAMP U.L./F.M. ROVED TNRU 6' PIPE SIZE. NELL FIG. 86 OR APPROVED EQUAL THREAD ROD RING G12INNEL FIG. 69 :.M. APPROVED (TYP) Revisions: A 0 0 0 I— r z h r Q N LL c c Jo L Q <z V) M�< Lij o m z QQ Q _J Q U_ z ow� � O U) � M W I Q N_ O -+J ;' 2 M O N d �m U 0C �vM Q�00 EX N 82 4--j a e ;� W .% d Cn a U d } z NNW U t IN n � J z O U g U� �z Q LLJ n DRAWN: JB CHECKED: ES DATE: 02 -18-08 SCALE: AS NOTED ;EAR... . v, G) . oIIINES 0 A�NT�NA P' .E jLICEPSE"M, §jm8a, a F Sheet No. P7.00 ® Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. FIRESTOP SYSTEMS November24,199s eL us PIPE HANGER DETAILS N.T.S. JOB # 21033