Loading...
08-985-012AIR DISTRIBUTION LEGEND DUCT: FIRST FIGURE IS SIDE 24XI2 NEW THERMOSTAT O SHOWN ® z NEW CEILING DIFUSER. POINT OF CONNECTION NEW SUPPLY RETURN GRILLE BETWEEN AND EXISTING WORK L - - - - - - - -1 ALL ELBOW MUST BE PROVIDED WITH TURNING VANES WHETHER EQUIPMENT OR DUCTS OR SHOWN ON DWGS. (SEE SPECS:EXISTING l TO REMAIN i-------- i 171/7/%��ll� TYP. 450 TAP -OFF WITH EXISTING EQUIPMENT OR DUCT VOLUME DAMPER �L VD VD TO BE REMOVED-�- i i MANUAL VOLUME DAMPER DIRECTION OF FLOW TYPE OF DIFFUSER 6 X 6 SIZE OF DIFFUSER 1 5 O CHILLER WATER SUPPLY £ f/ /���i�f/ AMOUNT OF CFM RETURN TO BE REMOVED Ti EXISTING THERMOSTAT TO CHILLER WATER SUPPLY E --- CHWS --- REMAIN RETURN TO REMAIN --- CHWR --- HOT WATER SUPPLY E NEW CHILLED WATER CHWS CHWR RETURN TO BE REMOVED / SUPPLY E RETURN --- HWS---- HWS HOT WATER SUPPLY is NEW HOT WATER SUPPLY RETURN TO REMAIN --- HWR----- E RETURN HWR NOTES I. 450 TAP -OFFS, SPUTTERS AT EACH TAP -OFF AND TEE, AND ACCESS DOORS SHALL BEE USED WHERE REQUIRED, WHETHER OR NOT INDICATED IN THE DRAWINGS. 2. IN AREAS WHERE NON -REMOVABLE CIELINGS ARE USED, PROVIDE 45 TAP -OFFS OF THE FIXED TYPE, WITH WIDTH PROPORTION TO BRANCH CFM. FAN SCHEDULE DESIGNATION EF-1 EF-2 EF-3 MANUFACTURER CARNES CARNES CARNES MODEL NUMBER VCDD010C VCDD010C VCDD010C AREA SERVED WOMENS RESTROOM MENS RESTROOM JANITOR ROOM (101A) C F.M. 90 85 85 E.S P. (IN. OF WATER) 0.25 0.25 0.25 SONES 1.3 1.3 1.3 R P.M. SP'® CTRL SPEED CTRL SPEED CTRL H.P. (A=AMP W=WATTS) 77W 77W 77W V OLT - PH - HZ 120 - 1 - 60 120 - 1 - 60 120 - 1 - 60 DRIVE DIRECT DIRECT DIRECT BACKDRAFT DAMPER YES YES YES INTERLOCK LIGHT SWITCH LIGHT SWITCH RUN CONTNUOSLY REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITTED FOR APPROVAL. 2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQUIPPED WITH SAFETY DISCONNECT SWITCH. 3. CONTRACTOR SHALL PROV DE CORRESPONDING ALL GALVANIZED STEEL WALL CAP (SEE DRAWING) AIR DISTRIBUTION SCHEDULE DESIGNATION A B MANUFACTURER TITUS TITUS MODEL NO. AND 1 OR TDC-AA 50 F CATALOG NO. LAY -IN LAY -IN FRAME TYPE 24X24 24X24 FIXED LOUVERS EGG CRATE DEVICE TYPE 1/2"X1/2"X1/2" FUNCTION SUPPLY RETURN PATTERN SEE DRAWING SEE DRAWING OPPOSED BLADE DAMPERS YES YES NOTES: 1. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITTED FOR APPROVAL. 2. ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETED. 3. UNLESS OTHERWISE NOTED, ALL AIR DEVICES FINISH SHALL BE BAKED OFF-WHITE. 4. SUPPLY, RETURN OR EXHAUST OUTLETS SERVED BY AN INDIVIDUAL DUCT BRANCH PROVIDED WITH AN ACCESIBLE MANUAL DAMPER SHALL BE SUPPLIED WITH INTEGRAL O.B.D. 5. FOR SQUARE NECK OUTLETS CONNECTED TO A RIGID DUCT, PROVIDE THE REQUIRED INSULATED SQUARE TO ROUND TRANSITION. ;UNIT VENTILATOR & FAN COIL UNIT SCHEDULE !UNIT TYPE FCU-1, 2,3 (E)ist.) FCU-4 (NEW) AREA SERVED SALES/SEATING Backroom (101) TOTAL SUPPLY AREA - CFM 1030 1550 E.S.P. - INCHES OF WATER 0.20 0.25 'MOTOR HORSEPOWER - HP (WATTS) 1/6 3/4 'AVAILABLE ELECT. SERVICE -V/PH 20811 /60 208/1 /60 ,GRAND TOTAL HEAT- BTU / HR 31,600 40790 TOTAL SENSIBLE HEAT- BTU / HR 24,200 36166 ENTERING AIR TEMP- DB/WB ff) 80/67 77.5/63.8 LEAVING AIR TEMP - DB/WB ff) ---- 56.2 /55.0 WATER FLOW - GPM 5.6 5.58 ENTERING WATER ff) 45 45 1LEAVING WATER (OF) 57 57 lMAX. COIL PRESSURE DROP - FT. H2O -- 5.0 MAX. MAX COIL VELOCITY - F.P.M. i --- 558 HEATING CAPACITY - KW , HOT WATER HOT WATER STEPS OF ELECT. HEAT CAP. - No. -- -- IWEIGHT- LBS. ---- 195 'DIMENSIONS - (L, W, H) IN. ---- 44 X40 X18 DESIGN MANUFACTURER TRANE TRANE MODEL NUMBER FCDB1202 BCHC036B MAX. FUSE SIZE ---- 15.0 WIN. CIRCUIT CAPACITY ---- 7.5 NOTES: 1- Component of each U.V. shall be enclosed in a suitable apparatus casing constructed of 16 gage steel panel. a) Each casing shall be lined thoroughly throughout with not less than 1 inch 3 pound density of fire retardant synthetic rubber -coated glass fiber insulat b) Each cooling coil shall be provided with a steel drain pan adequately insulated c) Drain pan shall extend under all uninsulated valves and piping wich are suject to candensation. d) All steel surface shall be provided with an approvaed corrosion resistant coating. 2- Single source power of voltage. RECTANGULAR DUCT HANGERS MINIMUM SIZE MAXIMUM HALF OF PAR AT 10 FT. SPACING PAR AT 8 FT. SPACING PAR AT 5 FT. SPACING PAR AT 4 FT. SPACING DUCT PERIMETER STRAP WIRE/ROD STRAP WRE/ROD STRAP WRE/ROD STRAP WRE/ROD P/2 = 30" 1" X 22 ga. 10 ga. (0.135) 1" X 22 ga. 10 ga. (0.135) 1" X 22 ga. 12 ga. (0.106) 1" X 22 ga. 12 ga. (0.106) P/2 = 72" 1" X 18 ga. 3/8" 1" X 20 ga. 1/4" 1" X 22 ga. 1/4" 1" X 22 ga. 1/4" P/2 = 96" 1" X 16 ga. 3/8" 1" X 18 ga. 3/8" 1" X 20 ga. 3/8" 1" X 22 ga 1/4" P/2 =120" 1 1/2" X 16 ga. 1/2" 1" X 16 ga. 3/8" 1" X 18 ga. 3/8" 1" X 20 ga. 1/4" P/2 = 168" 1 1/2" X 16 ga 1/2" 1 1/2" X 16 ga 1/2" 1" X 16 ga. 3/8" 1" X 18 ga. 3/8" P/2 = 192" NOT GIVEN 1/2" 1 1/2" X 16 ga. 1/2" 1" X 16 ga. 3/8" 1 1/2" X 16 ga. 3/8" P/2 = 193" UP SPECIAL ANALYSIS REQUIRED WHEN STRAPS ARE LAP JOINED USE SINGLE HANGER MAXIMUM ALLOWABLE LOAD THESE MINIMUM FASTENERS: STRAP WIRE OR ROD (DIA.) 1" X 18,20.22 ga. - TWO #10 OR ONE 1/4" BOLT 1 " X 22 ga. - 260 Ibs. 0.106" - 80 Ibs. 1" X 16 ga. - TWO 1/4" DIA. BOLT 1 " X 20 ga. - 320 Ibs. 0.135" - 120 Ibs. 1 112" X 16 ga. - TWO 3/8" DIA. BOLT 1 " X 18 ga. - 420 Ibs. 0.162" - 160 Ibs. PLACE FASTENERS N SERES, NOT SIDE BY SIDE 1 " X 16 ga - 700 Ibs. 1/4" - 260 Ibs. 1 1/2"X 16 ga. - 700 Ibs. 3/8" - 680 Ibs. 1/2" -1250 Ibs. 5/8" - 2000 Ibs. 3/4" - 3000 Ibs. NOTES: 1. DIMENSIONS OTHER THAN GAGES ARE IN INCHES. 2. TABLEALLOWS FOR DUCT WEIGHT, 1 Ib1ft2 INSULATION WEIGHT AND NORMAL REINFORCEMENT AND TRAPEZE WEIGHT, BUT NO EXTERNAL LOADS. 3. STRAPS ARE GALVANIZED STEEL; OTHER MATERIALS ARE UNCOATED STEEL. 4. ALLOWABLE LOADS FOR P/2 ASSUMETHAT DUCTS ARE 16 GA. MAXIMUM, EXCEPT THAT WHEN MAXIMUM DUCT DIMENSION (W) IS OVER 60" THAN P/2 MAXIMUM IS 1.25 in. 5. 12, 10, 8 ga. WIRE IS STEEL OF BLACK ANNEALED, BRIGHT BASIC, OR GALVANIZED TYPE. MINIMUM HANGER SIZES FOR ROUND DUCTS DUCT MAXIMUM WIRE ROD STRAP DIAMETER SPACING DIAMETER 10 DN 12' ONE 12 ga. 1/4" 1"x 22 ga 250 mm DN 3.7 m ONE 2.75 mm 6.4 rrm 25.4 X 0.85 mm 11"- 18" 12' TWO 12 ga. OR ONE 8 ga. 1/4" 1"x 22 ga 460 mm 3.7 m ONE 4.27 mm. 6 4 rrm 25.4 X 0.85 mm 19"- 24" 12' TWO 10 ga 1/4" 1"x 22 ga 610 mm 3.7 m TWO 3.51 mm. 6 4 mm 25.4 X 0.85 mm 25"- 36" 12' TWO 8 ga. 3/8" 1"x 20 ga 900 mm 3.7 m TWO 2.7 mm. 9.5 mm 25.4 X 1.00 mm 37" - 50" 12' TWO 3/8" TWO 1" X 20 ga. 1270 mm 3.7 m TWO 9.5 mm TWO 25.4 X 1.00 mm 51"- 60" 12' TWO 3/8" TWO 1" X 18 ga 1520 mm 3.7 m TWO 9.5 mm TWO 25.4 X 1.31 mm 61"- 84" 12' TWO 3/8" TWO 1" X 16 ga. 2130 mm 3.7 m TWO 9.5 mm TWO 25.4 X 1.61 mm NOTES: 1. STRAPS ARE GALVANIZED STEEL: RODS ARE UNCOATED OR GALVANIZED STEEL; WIRE IS BLACK ANNEALED, BRIGHT BASIC, OR GALVANIZED STEEL. ALL ARE ALTERNATIVES. 2. TABLE ALLOWS FOR CONVENTIONAL WALL THICKNESS, AND JOINT SYSTEMS PLUS ONE LB/SF INSULATION WEIGHT. F HEAV ER DUCTS ARE TO BE INSTALLED, ADJUST HANGER SIZES TO BE WITHIN THBR LOAD LMITS. HANGER SPACING MAY BEADJUSTEDBY SPECIAL ANALYSIS. RECTANGULAR DUCT REINFORCEMENT 2" W.G. STATIC POS. OR NEG. NO REINFORCEMENT REQUIRED RENFORCEMETIT CODE FOR DUCT GAGE NO. REINFORCEMENT SPACING OPTIONS DUCT DIM. 10' 1 8' 6' 1 5' 1 4' = 2-1/2' 2' 10" dn. 26 ga. B-26 B-24 NOT B-26 &26 REQUIRED 11", 12" 24 ga. B-26 B-26 B-26 B-26 B-26 13", 14" 22 ga. B-26 B-26 B-26 B-26 B-26 15", 16" 20 ga. G22 C-24 C-24 G26 C-26 C-26 B-26 B-26 17", 18" 20 ga. C-22 C-24 G24 C-26 C-26 G26 G26 B-26 19", 20" 18 ga C-20 G22 G24 G26 C-26 G26 G26 C-26 21", 22" 16 ga. D-20 D-22 D-24 D-26 G26 G26 G26 G26 23", 24" 16 ga. E-20 E= 22 D-24 D-26 D-26 G26 C-26 C-26 25", 26" E-20 F-18 F-18 G-16 NOT DESIGNED E 22 E-20 F-20 G-18 H-16 [=1 E-24 E-22 E-22 F-20 G-18 H-18 1-16G 4-16G D-26 E= 24 E 24 F 22 G-20 H-20 H-18G 1­18G J-16H D-26 D-26 E-26 E-24 F-24 G-22 K20G K18G 1­18G P 18G J 18H C-26 G26 G26 27", 28" D-26 G26 G26 29", 30" D-26 D-26 C-26 31" - 36" E 26 D-26 D-26 37" - 42" E= 24 E-26 E-26 43" - 48" F-24 F-24 E= 24 49" - 54" G-24 F-24 F-24 55" - 60" G-22 G-24 F-24 61"-72" H-22G H-22G H-24 73" - 84" �20G 4 22G 122G 85" - 96" 1-18H 1.20H MH 97" - 108" K-18H J 18H 1-18H 109" - 120" K-181 J-18I HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPERS) X FIRE RATED ENCLOSURE X FIRE RATED ROOF/FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X HVAC GENERAL NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AN0 - LOUIPIVIE-11 ► - NECESSARY FOR THE INSTALLATION OF HVAC SYSTEM IN ACCORDANCEVI'IT-H THtSE DRAWINGS. - FLORIDA BUILDING CODE 2004 - ANS/ASHRAE 15-1994 - - - NFPA PAMPHLETS 90A, 90B-91-2002 ; - - - SMACNA -1995 ASHRAE-2001 - OSHA-2005 2. THE WORK INCLUDES PROVIDING THE HVAC SYSTEMS, INCLUDING DUCTWORK, DIFFUSERS AND GRILLES, INSULATION, CONTROLS AND EQUIPMENT NECESSARY FOR A COMPLETE FUNCTIONING SYSTEM. HVAC SYSTEM INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: SUPPLY, RETURN AND EXHAUST DUCTWORK SYSTEMS WITH GRILLES, DIFFUSERS FILTERS AND DAMPERS. 3. TEMPERATURE CONTROL SYSTEM INCLUDING LOW VOLTAGE WIRING AND CONDUIT, TRANSDUCERS, ACTUATORS, CONTROLLER. 4. WARRANTY: PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED PROJECT. 5. DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS AS REQUIRED. FURNISH AND INSTALL ALL DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS AND MATERIALS NECESSARY TO FACILITATE THE SYSTEM FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT INDICATED. 6. CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES, ESPECIALLY WITH THE LOCATION OF STRUCTURAL MEMBERS, PIPING, SPRINKLERS, CONDUITS AND LIGHTING OUTLETS AND/OR FIXTURES. 7. ALL MATERIAL AND EQUIPMENTS SHALL BE NEW OF U.S. MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED PERSONNEL. 8. FLEX DUCT: PROVIDE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181) WITH 1-1/2" THICK 1 PCF FIBERGLASS INSULATION R-6 AND REINFORCED OUTER PROTECTIVE COVERNAPOR BARRIER. FLEX DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER 50, AND SHALL BE RATED FOR 2" W.G. PRESSURE AND 0 TO 250 DEGREES FAHRENHEIT. PROVIDE METAL ADJUSTABLE CLAMPING DEVICES, SCREW OPERATED. USE TWIST -LOCK CONICAL TAP COLLARS AT CONNECTIONS INTO SHEET METAL DUCTWORK. FLEXIBLE DUCTWORK MAYBE USED FOR BRANCHES TO DIFFUSERS AS INDICATED ON DRAWINGS. DO NOT EXCEED EIGHT (8) FEET IN LENGTH FOR ANY FLEX DUCT. 9. BALANCING DAMPERS: FABRICATED OF SAME MATERIAL AS DUCT, TWO METAL GAUGES HEAVIER THAN DUCT. MOUNT ON 3/8" SQUARE ROD WITH SAW SLOT POSITION INDICATOR. PIVOT AND BEARING, LOCKING POSITION REGULATOR. 10. ALL EQUIPMENT AND MATERIALS SHALL BE NEW, FREE FROM DEFECTS AND WITH MANUFACTURER'S WARRANTY. 11. PROVIDE DOUBLE THICKNESS TURNING VANES AT ELBOWS AND EXTRACTOR DAMPERS AT ALL DUCT BRANCHES AND TAKE -OFFS. 12. ALL EXHAUST DUCTWORK SHALL BE OF GALVANIZED SHEET METAL FABRICATED IN ACCORDANCE WITH SMACNA STANDARD FOR PRESSURE CLASS ACCORDING TO EACH SYSTEM. 13. FLEXIBLE CONNECTOR: WHERE REQUIRED PROVIDE U.L. LABELED NEOPRENE COATED FIBERGLASS FABRIC DUCT CONNECTORS. 14. CONTRACTOR SHALL BE RESPONSIBLE TO TEST & BALANCE THE HVAC SYSTEMS AS PER ASSOCIATED AIR BALANCE COUNCIL STANDARDS. 15. CONDENSATE LINES SHALL BE INSULATED WITH 1/2 INCH FOAMED PLASTIC. INSULATION SHALL BE WITH FLAME SPREAD 25, SMOKE SPREAD UNDER 50. 16. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. 17. CONTRACTOR SHALL PRINT UP INSTRUCTIONS FOR OWNER'S OPERATION OF SYSTEMS. 18. THE CONTRACTOR SHALL PAY ALL INSPECTION FEES. ALL COSTS OF PERMITS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK UPON FINAL ACCEPTANCE A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 19. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE LOCATION OF EXISTING EQUIPMENT, DUCTWORK, PIPING, CONDUITS, ETC., AND/OR ANY CONDITION THAT MAY AFFECT HIS WORK. 20. ALL AIR CONDITIONING DUCTWORK SHALL BE CODE GAGE GALVANIZED SHEET METAL INSULATED WITH 2 INCH THICK AND 1.0 PCF GLASS FIBER FLEXIBLE BLANKET INSULATION WITH ALUMINUM FOIL REINFORCED WITH GLASS FIBER FASING (FSKL) JOHN-MANVILLE MICROLITE (R-6 INSTALLED) OR APPROVED EQUIVALENT, DUCT SIZES SHOWN ARE NET FREE AREA. PROVIDE DOUBLE THICKNESS TURNING VANES AND EXTRACTORS AT ALL ELBOWS AND TAKE -OFFS. 21. ALL CONCEALED SUPPLY AIR DUCTS SHALL BE EXTERNALLY INSULATED WITH DUCT WRAP AS INDICATED IN SPECIFICATIONS. RIGID INSULATION SHALL BE PROVIDED IN EXPOSED LOCATIONS SUCH AS MECHANICAL ROOMS. 22. RETURN DUCTS LOCATED ABOVE UNCONDITIONED SPACES SHALL BE INSULATED THE SAME AS THE SUPPLY AIR DUCTS. 23. EXHAUST AIR DUCTWORK SHALL BE UNINSULATED. OUTSIDE AIR DUCTWORK SHALL BE INSULATED SLOPED BACK TOWARDS INTAKE LOUVER AT 1/8 INCH PER FOOT. 24. DUCT FINISHES AND SEALERS SHALL HAVE A SMOKE DEVELOPED RATING OF LESS THAN 50 AND A FLAME SPREAD OF 25 OR LESS. 25. CHILLED WATER PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH 150 POUND MALLEABLE IRON FITTINGS WITH SCREWED OR VITAULIC COUPLINGS TO MATCH EXISTING, AND SHALL BE PROPERLY SUPPORTED THROUGHOUT. ALL RUNS MUST BE SUPPORTED AT EVERY CHANGE IN DIRECTION AND A MINIMUM OF EVERY 6FT. (1" SIZE), 7FT. (1 W SIZE), 9FT. (1 W SIZE), 1OFT. (2" & 2 W SIZES) AND 12FT. (SIZES 3" AND LARGER). 26. ALL NEW CHILLED WATER PIPING SYSTEM SHALL BE INSULATED WITH 1-1/2" THICK "FOAMGLASS" INSULATION INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. PROVIDE REMOVABLE INSULATION COVERS TO ALL VALVES, FLOW MEASURING DEVICES, STRAINERS, AND ANY OTHER FITTINGS THAT MAY REQUIRE PERIODIC ACCESS IN THE FUTURE. 27. ALL RE -HEAT PIPE SHALL BE COPPER PRESSURE TYPE "L" CONFORMING TO ATMB-88. INSULATION THICKNESS FOR RE -HEAT PIPE SHALL BE 2" CELLULAR GLASS. i Revisions: 0 .0 I- z ^' M r7 Q o to N LL � o (�Ov v 2 li Q QZ a M - V J O V) LLJ m z QQ Q :2 J n- I=-Q U 0 z 0 O �W� MO W NI M 3 0 N M Q C14 ~ N_ O -4-J n M G N a U M 0t0 °�25 4 N 02 1 < o Q fN d IV Q z UCrNNLj o L"N J z O g Cn LLJ J LLJ C) _ z � LLJ UU LLJ 8 U Q V) O ��- _ m O � z Q LLJ z W 0 DRAWN: JB CHECKED: ES DATE: 02 - IS-05 SCALE: AS NOTED SEAL. r ! vMEINI L C �TO,SAMTANA .P.E DQEN31r a 6'07$8' -� Sheet No. M0.00 I JOB # 21033 1