Loading...
08-985-011NOTE: THE DETAILS ON THIS SHEET ARE CONSIDERED TYPICAL AND ARE NOT NECESSARILY CALLED OUT ON PLANS FILL VOID'' ;' - : • • : VERTIICAL ER TRACK AND FIF• ; OE CCG , JDON - - :__�FIB Wz �� ' ' SECTION - VERTICAL JT. AT BEAM :R Ft STEEL BEAM 20 GA CONT. l' STEEL JOIST FASTEN 2' O.C. FILL VOI AND FIF =.; STEEL CLIP �I e STAND-OFF I 7it, —-i CEILING lT1 P _ v a• 4- 7-CAULt V2' FIRED. GYPSUMB(:. 'T'rr : AREPROOFNG i F 6' Mlh SPRAYED FIREPROOFING -H METAL STIk r i':1' SECTION 24' O.C. (TYP.J VERTICAL JOINTS RUNNER TRACK AT �— M1T 20 GA— FASTENFFASTN -CLIP 2BEFORE FASTEN GYP. BD. FULL HT. SPRAYING PER FIRE TEST I,; . "::;. �• RUNNER FASTEN TO CLIPS , NOTE: ABUT TIGHTLY TO FPFCs ONE OR TWO HOUR NO PARTITION STEEL JOIST CANNOT BE _ A PART OF THE RATED 1 SEPARATION. 4 }+— I OR 2 LAYER GYP. BD. - HOUR RATED SHAM WALLS 1 ) EACH SIDE - As REQ D. SAFE AS REQUIRED SMOKE AND RATED PARTITION ADJACENT TO BEAM SPRAT ON FIRE PROOF ITT GYP. BD. ON= METAL STUD.' . ' I 1 .• STEEL JOIS.• \ C.: t • r STF` .SEAM 20 G: IP '1 2' OL. f FASTEN ' SPRAY y - ABUT TIGHTLY *OFPFCs 4NER FASTEN t ;i iO CLIPS : =� I OR 2 LAYERS I' , GYP. BD. EACH SIDE - AS REQ'D. �— SAFE AS REQV. ' .tRTITION UNDER BEAM RATED PARTITION UNDER JOIST �UIV: TO SKETCH 0 109, USG, HANDBOOK l YPICAL RATED PARTITION DETAIL UNDER BEAM AND/OR UNDER JOIST GREATER THAN 2' LESS THAN 6' FLOOR OR ROOF SLAB ASSEMBLY CUT GYPSUM PANELS TO FIT DECK CONFIG. V4' NOM. GAP FILL WITH ACOUST. SEALANT RUNNERS - ATTACH WITH ANCHORS 2'-0' OZ. CEILING CONTINUOUS STEEL STUDS (16' / 24' OjCJ ACOUSTICAL SEALANT RNNERS - ATTACH WITH ANC4iOR3 2'-0' O.C. FIN. FLOOR SECTION N.TS. TEST REF: T-3362-OSU T-1114-OSU GA-WP-1200 11 SMOKE ¢ ONE -HOUR PARTITION DETAIL IPERPQ3�lULAR TO DEW ROOF OR FLOOR DECK CEILING 5 ROOM FUNCTIONS VOT OTHERWISE RATED ENCLOSURE REQUIRED TO BE D BY A SMOKE PARTITION TEDTO THE DECK 515TANT WALLS MUST UOUS FROM FLOOR ABOVE UNLESS THE 4 FIRE RESISTANCE )OR/CEILING OR INGASSEMBLY. Ij ••�� FIREPROOFING MUST HAVE 2-HOUR THICKNESS OR GREATER ;;V.- TO SKETCH 109, USG, HANDBOOK Nrs. 2 SHAFT WALLS DETAIL EC.. TO SKETCH • 110, USG, HANDBOOK Nrs. 3 RATED PARTION UNDER BEAM a D FILL VOIDS OATH SAFING AND FIRE CODE COMPOUND 67=S RUNNERS MAX. 6' GYP. BD. CANTILEVER (-1- — -------I -� NOTE: BOARD MUST ( I I I SPAN MIN. 2 STUDS BEFORE CANTILEVF" - ABUT r!^ PD. TIGH'i TO.:, ENTIRE V I SAFING EQUIV: TO SKETCH IP 114, USG, HANDBOOK RATED WALL PERPENDICULAR TO BEAM N.T.S. (i)TYPICAL HEAD OF PARTITION FLOOR OR ROOF SLAB ASSEMBLY I > ' MAX. 2' FILL VOIDS. SEE DETAIL % TIGHTLY FILL VOIDS AT METAL DECK WITH SAFING MATERIAL - 4 O/CF DEN RIVERS - ATTACH WITH ANCHORS 2'-0' O:C. CEILING CONTINUOUS STEEL-57=5 (I6' / 24' O:CJ SAFING AS REQUIRED ACOUSTICAL SEALANT RUNNERS - ATTACH WITH ANC 4ORS 2'-O' OjC. FM. FLOOR • v 'a SECTION N.T.S. TEST REF. T-3362-OSU T-ITI4-OSU GAWP-1200 N.T.S. 12 SMOKE E ONE -HOUR PARTITION DETAIL (PElWe VIQl1.AR TO DECK) STRUCTURE ABOVE N.TS. D ABUT TIGHTLY TO FPFG 20 GA. Z-CLIPS 2' O.C. FASTEN BEFORE SPRAY R J NER FASTEN TO CLIPS N.T.S. CONC. SLAB ON METAL DECK b v % F- • O 4 _ X— -d a tTj t� bTis' — �°— �. i•1'IJ 1 fV 1 ll�• D'�' `—FIN. FLOOR OR ROOF ,♦.♦.♦.,I FACE TO BE o. WITH DRYWALL SEALANT, OR TAPE AND JOINT C40MPOUND NOTE: ALL RATED PENETRATION DETAILS ON THIS SHT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPANY DETAILS FOR HOSPITAL AND INSTITUTIONAL CONSTRUCTION HANDBOOK DATED FEBRUARY 1SSI, REVISED AUGUST ISSL EQUIVALENT DETAIL NUMBERS ARE SHOU,N WHERE APPLICABLE FILL VOIDS WITIJ AGFILL VOIDS WITH SAFM! AND FIRE CODIi, 'OWD AND FIRE CODE COP ' RUNNER'r _tJ 2' Oi- RtMJER FASTP', JG RDOFi: ROOFR LOL ,.K F - i i-t t r. D •i f 1.1 I , d D D , 'lJ4 Jl -d t ED FIREPROOFNG cl 6PRAYED FIREPROOFING E • --}--I f i „AVITY FULLY PACKED I I ( WITH SAFING NOTE: BOX M WITH • �. -' ;:I.T7%.* '::� I I GYP. BD. AND METAL STUDS • \ — I I i WHEN STEEL JOIST CONDITION — ��__2'4'40 GA GALV. ANGLE — — — — 6, RETAINER FASTEN TO A DECK 2' O.C. CCNT. ANGLE RETAINER 4' SCREW TO STUDS ONE OR TWO HOUR] ONE OR TWO HOUR PARTITION PARTITION EQUIV: ` l • ,KETCH 101, USG, HANDBOOK �l. SMOKE 4 RATED PARTITTION ADJACENT TO BEAM Nrs. Tj SMOKE 4 RATED PARTITTION ADJACENT TO BEAM NTs. (STRUCTURALLY BOXED IN) DECK I HR RATED MEMBRANE ;�• ,;, NEW 5/8' TYPE 'X' },`•'* NEW STUD EXTENSION REMOVE EXIST. DRYWALL a• a+ RATED CEILING ROOF)FLOOR DECK 3 NOTE: DRYWALL JOINTS ALL DRYWALL AT a D c D a OPP IITYE MWALL 5/8' TYPE 'X' SIDc D c D EXISTING WALL REMOVE EXIST. D ' D HEAD TRACK ( ;I EXTEND EXISTING WALL 2 HR. WALL THRU 1 HR Ma ASV _ TO DECK FOR I HR WALL (SHAFT WALL SIMILER) I` <) EXTEND ALL LAYERS OF DECK I GYP. BD. TO DECK AND SAFING SEAL AT FACE LAYER WITH ACOUSTICAL SEALANT. IN I HR. RATED 2 PER STUD EXTRA WIDE WALL SPACE 7T1 HR RAT(=D I; MEMBRANE 9) TYPICAL HEAD OF PARTITION I I . I GYPSUM WALLBOARD BLOCK (IR' X 19 SPACED IS' Or- VERT. AT EACH CHANNEL '1 WIRE TIE LATH, BLOCK • ;. IJ AND CHANNEL TOGETHER �'• 11 3.40 D M LATH (GALV) GYPSUM PLASTER —TIGHTLY FILL VOID DECK WITH SAFMG INSULATION 1 - t/1' CRC 16' Or- RATED CONC. BLOCK SEE A.:11 PLAN FOR SIZE AND RATING SHAFT SIDE '1 NOTE: THE BLOCK MANUFACTURER FINISH SIDE SHALL SUBMIT DESIGN CALCULATION .1' '•:' STATING THE APPROVED EQUIVALENT 1 ' 1 I SECURE I - IR' CRC TO ANGLE THICKNESS AS REQUIRED BY THE FIN, FLOOR STANDARD BUILDING CODE /�14/2' X 1-In' X 18 GA CONT. ANGLE "• FLOOR AND STRUCTURE ABOVE FLOOR ::•1;1. . FASTEN AT 24' O:C. WALL SECTION WALL SECTION (MAXIMUM HEIGHT 18'-V) KTS. N.T,s. [ 13) TYPICAL RATED BLOCK WALL FIRE OR SMOKE SCHEDULE I ' CEILING PI 5/8' TYPE 'X' GYPSUM 5/8' GYPSUM BOARD WALLBOARD AT RATED Al OVER 3 5/8' METAL STUDS PARTITIONS EL F.E./F. HOSE CABINET/ ELECTRICAL/ TELEPHONE PANELS I 0 I � _i U r:ruvc3 raviivrc ... DING "v DUCT °CTRICA GL 1V 18' 18' oo (LEA CLE CLEA A/C DUCT RECESSED LIGHI FI KTURE CEILING ROOM CORRIDOR ROOM N.TS. NTs. 14 TYPICAL TWO HOUR PLASTER SHAFTWALL DETAIL (014xnrl /a r*ff W-0', )NDUIT (10) PARTITION PENETRATION DETAIL OF N.TS. ONE HOOUR RATED MEMBRANE �� .•_� Oil _ .�Oi � NOTES: L JOINTS MAY BE OPPOSITE IF SAFEMG IS USED IN CAVITY. REF: CEG 8-11-83 CEG 5-S-84 2. JOINTS IN FINISH LAYER TO RECEIVE TAPE AND JOINT COMPOUND N•Ts• ,� HORIZONTAL JOINT REQUIREMENTS ABOVE SUSPENDED CEILINGS N.T.S. N.T.S. C �• ` 4� S NG pEpt' :• s NOTE: SECTION REFER TO 1/8' FLOOR PLAN FOR EXACT LOCATIONS N.T.S. F. E. CABINET l�o SMOKE RESISTANT WALLS AND HAZARDOUS N.T•S• 1-1 FIRE EXTINGUISHER CABINET/ELECTRICAL/ N.TS. j8 EQUIPMENT CLEARANCE DETAIL NTS. jg NT.s• N.T.S. FUNCTION SEPARATION WALLS (As DEFINED IN sTANDARD euixwx CODE flows.) TELEPHONE/PANELS SECTION Revisions: 0 0 A z Indv �z N a. a OWN OZ /W $..s A OW !• OM21 3� LLA u. zA O r'7 z 1'y z LLI a DRAVft4 VC CNECIM& LEN DAIL 02-IS-08 SCALER. • Jl NL7.a. 4. • �` ••` E. "+" Sheet`* No: A-9 OF 9 JOB 0 21033