08-985-009NnTF- TWF= i PT.4II_e TIN TI-I1S sI-IEET .42E CONSIDERED TYPICAL AND ARE NOT NECE65,4RILY CALLED OUT ON PLANS SMALL OPENINGS MAY BE PATCHED USING JOINT COMPOUND, CAULK, OR BLOW-OUT PATCHES. LARGE OPENINGS REQUIRE A BLOW-OUT PATCH i OR WALL REPAIR SMOKE RESISTANT WALLS UP TO 1/2' OPENINGS MAY BE FILLED FULL DEPTH OF DRYWALL WITH ACOUSTICAL SEALANT. STRIKE OFF AT tin FACE OF DRYWALL. DO NOT SPREAD BEYOND OPENING.ALTERNATIVELY, A PROPRIETARY SYSTEM MAY BE USED. 'MAXIMUM UP TO V4' OPENINGS MAY BE FILLED WITH JOINT COMPOUND. UP TO 1/8' OPENINGS DO NOT REQUIRE ANY TREATMENT. LARGER THAN iR' OPENINGS REQUIRE A BLOW-OUT PATCH (SEE DETAIL 2 4 3 THIS SHEET). SOME LOCAL JURISDICTIONS DO NOT ALLOW THE BLOW-OUT PATCH, 30-MiN- 1-HR, 4 2-HR. RATED WALLS (FIRE FIRE 4 SMOKE) 3- AND 4-HIT WALLS REQUIRE THE USE OF A PROPRIETARY SYSTEM 1 TYPICAL DRYWALL SEALING DETAIL AT N.T.S. RATED PARTITION PENETRATION —CMM OR CONCRETE PROPRIATORY SYSTEM OR Ul.. TESTED NONSHRNC CGOMPI ETELY OPENING AS REQUIRED FOR CLOSURE gOVIDE CELL CLOSURE OF COMBUSTIBLE MAUL IN GML. WALLS CONCRETE MASONRY UNITS OR SOLID CONCRETE WALLS I I TYP SECT. I — STUDS RIANNER CHANNELS, TYPICAL L _ I•I S i i S I CAB (BUTTER BACKSIDE SURFACE) I I MIN. 2 'S' SCREWS PER SECTION, MR 3' FROM OPENING AND EDGE OF PATCH I 1 E3• I I I L___ __ _ ANNULAR OPENING N PARTITION AROUND I • I I • I PIPE OR CONDUIT GREATER THAN 3' DIA. I i i I CUT GYPSUM BOARD TIGHT TO PIPE =I I I DO NOT MUD AND TAPE EDGES Mn HOLES OVER 3' DIA. BLOW-OUT PATCH ONLY 1 LAYER ON EACH SIDE OF WALL REQUIRED FOR 1 OR 2 HOUR WALLS. BLOW-OUT PATCH IS NOT ACCEPTABLE ON WALLS RATED AT 3 OR 4 HOURS. NOTES: L BUTTER ENTIRE BACK SIDE OF PATCH WITH JOINT COMPOUND. 2. LEAVE ALL SCREWS EXPOSED. .,o . • EQUIVALENT TO USG WALL PENETRATIONS. FIRE TEST FILE T2-1313 PENETRATION DETAIL V (11-1-84) 2) TYPICAL DRYWALL PATCH DETAIL AT PENETRATIONS LARGER THAN 3' DIA1`+1 �l�t'o�lcoNlt��ol� 6 NOTE: ALL RATED PENETRATION DETAILS ON THIS SHT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPANY DETAILS FOR HOSPITAL AND INSTITUTIONAL CONSfRUr.nc.,K- HANDBOOK DATED FEBRUARY iSSI, REVISED AUGUST 1991. EQUIVALENT DETAIL NUMBERS ARE SHOWN WHERE APPLICABLE • I ;�I GM PATCH BUTTER BACKSIDE SURFACE. DO NOT REMOVE JOINT S S COMPOUND DISPLACED AT E `ems TYPE 'G' SCREWS MR 2 PER 6' MIN, 4 3' 6MR SECTION. LEAVE EXPOSED. ANNULAR OPENING M PARTITION AROUND PIPE OR CONDUIT V DIA OR LESS. HOLES UP TO 3' DIA. HOLES UP TO 3' DIA, BLOW-OUT PATCH ONLY I LAYER ON EACH SIDE OF WALL REQUIRED FOR 1 OR 2 HOUR WALLS. BLOW-OUT PATCH IS NOT ACCEPTABLE ON WALLS RATED AT 3 OR 4 HOURS. NOTES: L BUTTER ENTIRE BACK SIDE OF PATCH WITH JOINT COMPOUND. 2. LEAVE ALL SCREWS EXPOSED. EQUIVALENT TO USG WALL PENETRATIONS. FIRE TEST , FiLE 72-513 PENETRATION DETAIL V (11-1-84) NTS. 3TYPICAL AT PENETRATIONS LESS THAN 3'' diamATCH DAIeter t ® COVER PLATE \ " / DRILLED HOLE M DRYWALL SECTION 1-1 SAFING INSULATION DRILLED HOLE IN DRYWALL APPROX.EQUAL SECTION 2-2 48= MAk — — 3/8, OR V1' THREADED ROD METAL STUDS BEHIND GYP.13D. I I METAL RUNNERS 1 RATED DRYiUALL CLCx PACK WITH THERMARVER L� PER TEST ASSEMBLY MULTIPLE CONDUIT / PIPE MULTIPLE /pIp�p��T�TIONS SAFING AT MANUFACTURED NUT AND COVER PLATE DENSITY WITH NO VOIDS AS REQUIRED FOR CLOSURE nrz r•erxs PLASTER AND METAL LATH GYPSUM PLASTER. METAL LATH AND METAL STUD PARTITIONS REF: UL SYSTEM No. WL 1065 (o PIPE PENETRATION DETAIL NTs. MULTIPLE PIPE PENETRATION DETAIL MIN. 2 x 2 x 10 GAGE ANGLE ATTACHED TO ALL FOUR SIDES OF DAMPER SLEEVE W/ 010 SHEET METAL SCREWS MIN PIPE INSULATION (IF APPLICABLE) CAST IRON PIPE 2 PER SIDE OR I EVERY DOES NOT CONTINUE THRU SLAB 8 INCHES. ATTACH TO SLEEVE OPENING I' NOT TO WALL. OF NON SHRINK GROUT CHANNEL TO SUPPORT SERVICES NON -RATED CEILING EQUIV: TO SKETCH 305, 306, USG, HANDBOOK T.S. S PENETRATION DETAIL IN RATED CEILING DUCT COMBINATION SMOKE/FIRE DAMPER BUTT INSULATION TO ANGLE. DO NOT INSULATE DUCT THRU A/C DIFFUSER WALL PROVIDE OPENING BETWEEN PACK IN FULL WITH THERMA CAULK UNDERSIDE SMOKE TIGHT WALL AND DAMPER SLEEVE FIBER FIRE SAFIINSULATI (TYPa AS PER MANUFACTURER NG I/4' MAX.Fl RECOMMENDATION SMOKE/FIRE PARTITION NOTES: 1. PROVIDE SUPPORT AT FLOOR PENETRATIONS FOR SARNG WHEN PIPES ARE OVER 2' WIDE. NOTES: 1. SEE MECHANICAL DRAWINGS FOR DAMPER DETAILS. 2. MOTOR SHALL BE MOUNTED ON DAMPER SLEEVE AND TO BE MONITORED TO FIRE ALARM SYSTEM. 3. ALL PIPES, CONDUITS, AND DUCTS AT ALL SMOKE/FIRE WALL PENETRATIONS SHALL BE DONE a W DEGREES ON BOTH SIDES. METAL STUDS BEHIND I I I I GYPSUM BOARDIC-4 I I THERMARBER SAFING MATERIAL PACKED TIGHTLY 5/8' TYPE 'X' DRYWALL PATCH I METAL RUNNERS TOP AND BOTTOM _ _ APPLY DRYWALL COMPOUND TO I I I I BACK SIDE OF DRYWALL PATCH. SEAL SMOKE TIGHT AT ALL EDGES (TYPJ. PARTIAL ELEVATION MA IN WALL S AWACE I-:'j iPATCH SCREW I I LRIMER TRACK SECTION PARTIAL ELEVATION RUNNER TRACK SECTION TAPE AND FINISH SECTION FLUSH PATCH - SMALL NTs. [4) FLUSH PATCH DETAIL BOTTOM OF STRUCTURE A/C DUCT THRU FIRE PARTITION METAL STUD FRAMING AROUND DUCT I I I I I ( I I 24' JAX ICEILING LINE USE INTERMEDIATE STUD WHEN SPACING IS GREATER THAN 24' DUE TO LARGE DUCT T; OF METAL STUDS (BEYOND) Nrs. 9)TYPICAL DUCT PENETRATION DETAIL BOTTOM OF STRUCTURAL DECK CAULK SMOKE TIGHT (TYP.) EACH SIDE i'-0' SMOKE/FIRE RATED PARTITION MAX (SEE WALL TYPES) BLOW UP PATCH TO BE LJ ONE LAYER 5/8' TYPE 'X' GYPSUM WALLBOARD EACH SIDE (SEE SIMILAR DETAIL THIS SHEET) MULTIPLE CONDUIT PENETRATING FIRE/ SMOKE RATED PARTITI METAL HANGERS (TYP APPLY DRYWALL COMPOUND TO BACK SIDE OF DRYWALL PATCH EACH SID SEAL SMOKE TIGHT AT ALL EDGES (TYP. UNSLEEVED r' a'�" `"" /SLEEVED FOR PIPES AND CONDUIT PIPING SUBJgCT TO—// FOR PIPES AND CONDUIT CONDENSATION NOT TO VCIOBNTTRRTAICCT(ON, CONDENSATION. IOMOVEMENTN. MSIA ATION WHERE EXPSUBMSION APPLICABLE AND/OR CONDENSATION. UMPBUNDLE SECURE I, I ACOUSTIC CAULK 1/2' MAX (SAFE IF OVER V29 TYPICAL SEAL CONDUIT FOR T O EAR MCHEESS WIRE PENETRATIONS FIRE OR SMOKE WALL PENETRATIONS (SLEEVES SHALL BE SECURED PLASTER DRYWALL, CONCRETE, OR MASONRY MMOVEE"MENTNTTHE ) TO PREVENT TYPICAL SEAL AS FOLLOWS: LESS THAN bl' • ACOUSTIC CAULK OR DRYWALL JOINT COMPOLNO (NO TAPE) MORE THAN 14' _ ROUE W SY4 01 _. TYPICAL CONDUITS (SLEEVED AND/OR UNSLEEVED). AND WIRE PENETRATIONS DETAIL NTs. MR 2'x2'x10 GA. ANGLE ATTACHED TO ALL FOUR SIDES tLV W SHEET METAL SCREWS MINIMUM 2 PER SIDE OR I EVERY 8 INCHES ATTACHED TO SLEEVE NOT TO WALL DAMPER (SEE MECHANICAL DRAWINGS) BUTT INSULATION TO ANGLE DO NOT INSULATE DUCT THRI WALL PROVIDE OPENING BETWEEN WALL AND DAMPER SLEEVE AS PER MANUFACTURER RECOMMENDATION NOTE: L SEE MECHANICAL DRAWINGS FOR DAMPER DETAILS. 2. ALL PIPES, CONDUITS AND DUCTS AT ALL FIRE WALL PENETRATIONS SHALL BE DONE AT W DEGREES ON BOTH SIDES. N.T.S. (i0) TYPICAL INSULATED DUCT PENETRATION DETAIL Nr6. BOTTOM OF STRUCTURAL DECK c FI�REmB sssssssssssssssss sssssssssssssssss<�sssss I II i I I I I I I I L•: •:I I I I I I I I DRYWALL OVER METAL FURRING STRIPS 1 IDES) a • . •. _ METAL 4„ y� ,�••; �..••. SEAL `• TIGHT ( • ° •: FIRE S • .., t • ' '. • ••. NOTE. t •% BLK IMMEDI • •.•: ] r •�. y ... • •. ARGON NOTE= ALL PIPES, CONDUITS, DUCTS AT ALL SMOKE / FIRE WALL PENETRATIONS SHALL BE DONE AT W DEGREES ON BOTH SIDES SMOKE TYP_) M FILL WITH MSUL FOR CON,. WALL, FILL ATELY ADJ. WIT►4 CONQ THEN APPLY THIS, DETAIL EQUiV. TO USG PILOT FIRE TEST: FLOOR PLAN -CONDUIT FIRE STOPPING -REPORT 23396 EQUIV. TO USG WALL PENETRATIONS FIRE TEST FILE T2-1313 EQUIV. TO USG WALL PENETRATIONS FIRE TEST FILE T2-1313 FILE 1-4651 ( 5-26-'i6) PENETRATION DETAIL ' F ' ( 11-1-84) PENETRATION DETAIL ' F ' ( i1-1-84) REF: U.L. SYSTEM No. 83 12 MULTIPLE PIPE PENETRATION THRU 14 MULTIPLE PIPE PENETRATION DETAIL 15 PIPE PENETRATION THRU MASONRY Nrs•' 11 PIPE PENETRATION THRU SLAB Nlrs. WALL DIFFUSER DETAIL N.T.S.iNrs. ONE HOUR WALL DETAIL Nrs. .. • '• • f EXTERIOR 4, • .• q, . • - .- • .• FIRE BARRIER a • f : • ?' PUTTY d • • . • v . /-PIPE DRY" MTL FUF STRIPS li L�l m REF: U.L. SYSTEM No. 84 16 PIPE PENETRATION THRU MASONRY BOTTOM OF STRUCTURAL DECK PIPE HANGERS (TYP AT BOTH SIDES) MAX I I PIPE DRYWALL TYPE 'X' ON METAL STUDS SEAL SMOKE TIGHT (TYP-) EACH SIDE I \ FOR SEALING AND/OR I PATCHING OF OPENING I SEE DETAIL NO.8 THIS SHT. DOTED LINE INDICATE PATCH CONDITION N FULL WITH REF: U.L. SYSTEM No. 84 16 PIPE PENETRATION THRU MASONRY BOTTOM OF STRUCTURAL DECK PIPE HANGERS (TYP AT BOTH SIDES) MAX I I PIPE DRYWALL TYPE 'X' ON METAL STUDS SEAL SMOKE TIGHT (TYP-) EACH SIDE I \ FOR SEALING AND/OR I PATCHING OF OPENING I SEE DETAIL NO.8 THIS SHT. DOTED LINE INDICATE PATCH CONDITION N FULL WITH 4FING NSUL. DR CON,. ELK. _L I1"IM1EDIATELY NOTE- L ALL PIPES AND CONDUIT AT SMOKE/FIRE WALL PENETRATIONS SHALL EAS WITH CONIC, BE DONE AT W DEGREES ON BOTH SIDES. 'PLY THIS DETAIL Nrs rl-1� TYPICAL PIPE SUS ^ AT RATED PARTITI BOTTOM OF STRUCTURAL DECK PIPE HANGERS (TYP. I'-0' AT BOTH SIDES) MAX. PIPE SMOKE OR FIRE RATED PARTITION U.L SYSTEM NO. W-L-1054 F RATING - I HOUR AND 2 HOUR A 3 3 U1 T RATING - 0 HOUR r FIRE RATED CONCRETE 2 OR CONCRETE BLOCK WALL 3M FIRE BARRIER MOLDABLE PUTTY SEAL 5MOKE TIGHT INSTALLED FLUSH TO ITYPJ EACH SIDE BOTH SURFACES OF FOAM GLASS PIPE THE WALL INSULATION THICKNESS 3 L AS SPECIFIED. EXTEND 2 METAL PIPE / CONDUIT V BEYOND WALL ON BOTH SIDES A —�---- AS REQUIRED FOR CLOSURE SECTION A -A CUT OPENING IN WALL WITHIN 1/4' OF FOAM L WALL ASSEMBLY - THE I HOUR OR 2 HOUR FIRE -RATED GYPSUM WALLSOARD/STUD WALL A50B'ISLY SHALL BE CONSTRUCTED GLASS AND SEAL OPENING OF THE MATERIAL AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS INCLUDE FEATURES. UMT14 DRYWALL MUD IN Ti•E UL FIRE RESISTANCE AND SHALL THE FOLLOWM CONSTRZTIGN A STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOODS STUDS TO CONSIST OF PROVIDE CELL CLOSURE NOMINAL 2 BY 4 WA LUMBER CENTER. STEEL TOBESPACED -4-ESpONNpMiNI R M 2-V! INCH WIDE AND SPACED p6=5 FRE ArI6�TP C 4 Y, T oPETNNNo SHIu L BEEFFRAI'ED ON All SIDES USING THS OF ST�EEI. Sty M5 BETLLEETHE N T OF SV RfICAL OF NON-COMBUSTIBLE STUDS ToTHEW THE FRAMED4 INCH STEEL � ola�TERR O� WALL. �IN HK+ MATERIAL M C1111. WALLS RTEMIN15 WTAL EDHE IIN�WID�ER�ANDTi TO M THAN OF THE THE OPENNWA A 2 TO 3 INCH CLEARANCE IS PRESENT BETWEEN THE PENETRATING ITEM AND THE FRAMING ON ALL FOUR SIDES. B. WALLBOARD GYPSUM• - 5/8 INCH THICK 4 FOOT WIDE WiTH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, TRIC"65, NUMBER OF TION 04ALL BE AS SPECFIED IN THE INDIVIDUAL U309 FASTENER TYPE AND SWEET AMAXC UL SYSTEM No 202 OR U400 SERIES DESIGN IN THE FIRE RESISTANCE DIRECTORY. A M DIAMETER OPE4NG 1514-1/) INCH FOR WOOD STUD WALLS. NOTE: THROUGH PENETRANTS - ONE PNEUMATIC TIRE PIPE, OR CONDUIT TO BE CENTERED WITHIN THE FiRESTOP SYSTEM. MAXMIM ALL PIPES, CONDUITS AND DUCTS AT ALL SMOKE/FIRE WALL ONE STEEL PIPE, OR CONDUIT EMT PER OPENING, CENTERED N OPENING. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON PENETRATION SHALL BE DONE AT W DEGREES ON BOTH SIDES. BOTH SIDES OF FLOOR OR WALL AN ANNULAR SPACE OF MINIMUM 0 INCH TO MAXMM 2-V4 INCH IS R OUiRED WITHIN FIRESTOF SYSTEM, PNEUMATIC TUBE PIPE, CONDUIT OR TUBING TO 13E RIGIDLY SUPPORTED ON BOTH SIDES OF WAN. ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF PNEUMATIC TUBE, CONDUITS OR TUBING MAY BE USED: A PNEUMATIC TUBE PIPE - NOMINAL 10 INCH DIAMETER (OR SMALLER) Ib GAUGE, COLD ROLLED, ELECTRIC WELDED STEEL, FLASH REMOVED, DEGREASED AND HOT OF GALVANIZED. S. CONDUIT - NOMINAL 4 INCH DIAMETER (OR SMALLER) STEEL ELECTRICAL METAWC TUBING OR STEEL CO CUIT. . FILL, VOID OR CAVITY MATERIAL- - SEALANT - IN 1 HOUR FIRE RATED ASSEMBLIES, MINMM 5/8 INCH THICIQESS OF FILL MATERIAL APPLIED WITH THE ANNULUS, FLUSH WITH BOTH SURFACES OF THE WALL IN 2 HOUR FIRE RATED ASSEMBLIES, MNMM 1-V4 INCH THICIQNESS OF FILL MATERIAL APPLIED WITHIN TIME ANNULUS, FLUSH WITH BOTH SURFACES OF WALL MAtcl'11'I MOM MN" rul l y PIPt 15m mm BLAB THICr M RATING B' 614' 1Y' 2 Hm tea' 1214' 1' 3 HM NOTE MW111M AW LAR SPAR BtfltM PFR AND OP*JM NOT TO MOM 24' EQUIV. TO USG WALL PENETRATIONS FIRE TEST FILE T2-1313 PENETRATION DETAIL ' F ' (11-1-84) HILn CONSTRICTION CINB1ICALS, MG - r-S-oiNE OR Fsaml SEA -ANT. REF. UL SYSTEM No202 -BEARING THE LL GLASSFiGATION MARKING: Nrs. 4PENETRATION F!RESTOP FOR METAL PIPE/CONDUIT a PIPE PENETRATION DETAIL MLr6. 19 i 4 2 HOUR PENETRATION DETAIL rLTs. 2 TNTs. THROUGH A CONCRETE WALL Rev' 0 0 0 0 z ' a v Miz 1 O� x � r..r z NEMI 2 cwIIIIII x V_ �J i�1 O = Q O W Fy 3� v tin w � z J z In O v �z H < z °4 LLI a DIRAVNN& VC CHZC3MA LEN DATL 02-IS-08 SCAIL N T S. lTI- �y Sheep, `N0.- A-7 OF 9 JO$ 4 21033