08-985-007I
a
00
N
00
O
0
N
O
3 -
a
If)
U
O
0
M
O
n -
0
a _
hl
DOOM DETAIL&
5/8' CEMENTITIOUS n
u YPE 'X'
WALLBOARD WITH GYPSUM
'
SCHEDULED FINISH
F_R.P. PANELS WALLBOARD
—�
ON 5/8' DRYWALL
2 METAL STUDS
3 5/8' GALV.
CAULK (TYP. EACH
CONT. GALV. STEEL STUDS
16' O.O.
FLOOR FINISH MARBLE SILL CERAMIC
SIDE)
RUNNER
SEE FINISH ON THIN SET TILE ON THIN
HOLLOW METAL FRAME
SCHEDULE SET
CONT. P.T. 1 X 4
3 CLIPS PER JAMB
�
ZING CORNER 4 ,...- .
VA RIES
lu
SQUARE EDGE
if
CASING BEADS
zz
GALV. HEAVY
1 1
cD N
SEALANT DUTY STEEL
1/2'2
2
I u.� W
TRACK 4 BALL
I z
WOOD BI -FOLD BEARING TRACK
DOORS PER ASSEMBLY
SCHEDULE
Q-
FINISH FLOOR
NOTE:
t-
(SEE SCHEDULE) s
THRESHOLD SHALL NOT HAVE
2" 5�8'
ANY CHANGE IN
GREATER THAN 1:2LSLOPE.N
J-1 H-1 JAMB DETAIL MEAD SIMILAR N.T.S.
H-2 BI -FOLD DOOR HEAD DETAIL N.T.S.
T-1 THRESHOLD DETAIL N.T.S.
151A BY PEMKO f
NEW FLOORING
3'
if 1/4'
EXISTING CONCRETE
SLAB
No. 10 x 1-1/2" FHWS,
PHILLIPS (FACTORY
PROVIDED)
= COLOR SELECTION AND 151A HALF SADDLE, 1/4' X
FINISH BY OWNER 3', FLUTED
-2 T'HRE514OLD DETAIL_ N.T.S.
FRAME HEAD RABBET
HINGE
4: DEADLOCK STRIKE
� HOSPITAL ARM
PULL (LOWER BASE)
AND PUSH PLATE
4. PUSH BAR AND PULL
(t STRIKE FOR KNOB
LOCKS, HANDLE
SETS. ROLLER
LATCHES 4 EXIT
DEVICES
ct HINGE
SCHEDULED FLOOR BOTTOM
OF
FRAME
TYPICAL DOOR DETAIL.
N.T.S.
DOOP SCHEDULE
00
DOOR
p00R
DOOR
DOOR SIZE
_
FRAME
DETAILS
HDW.
LABEL
AUTO.-
^ ^ ^ l l
No.
No.
TYPE
MAT.
1" 1AT.
SET
NO.
ASSEM.
POOR.
(A.D.)
RE1"1ARKS
- - - - , - - - - - _ -
WTH.
HGT.
TH.
JAi" IB
HEAD
TRESH.
100
100
A
ALJGL.
3'-0'
1'-0'
1 3/4'
ALUM.
_
-
-
= EXISTING W/ DOOR Cl..OSER
101
101
8
WOOD
3'-0'
1'-0'
13/4'
METAL
J-1
H-1
T-2
-
-
-
IOIA
101A
C
WOOD
2'-0'
1'-0'
13/4
-
=
H-2
-
-
-
-
102
102
B
WOOD
3'-0'
-1'-0'
13/4
HM
J-1
H-1
T-1
-
-
_
LOCATED EXISTING DOOR WITH
103
NOT
USE
104
104=
B=
WOOD*
3'-0'
1'-0'
13/4
HM
=
_
_
-
-
-
= EXISTING W/ DOOR CLOSER
100
105
B
METAL
3'-0'
1'-0' 1
1 3/4'
HM
=
_
_
-
-
8
EXISTING W/ DOOR CLOSER
105
G_1 4 2
- I
PLYWD.
2'-8'
21-VT
1'
-
-
-
-
-
-
-
WITH AUTOMATIC CLOSER
DOOR NOTES
1.
ALL DOORS AS SHOWN ON FLOOR PLANS ARE EXISTING TO REMAIN.
2.
CONTRACTOR SHALL NOTIFY ARCHITECT IF ANY EXISTING DOORS (FIRE RATED OR OTHEWISE)
ARE FOUND DEFECTIVE OR NOT MEETING STANDARDS SET IN THIS CONSTRUCTION DOCUMENT SET.
3.
ALL EXISTING DOORS HAVE ACCESSIBLE HARDWARE.
4.
DOOR NUMBERS CORRESPOND WITH ROOM NUMBERS FOR EASE OF IDENTIFICATION. SEE
FLOOR PLANS FOR LOCATIONS.
5.
DOORS, JAMBS, AND TRIM TO BE PAINTED WITH DTM BONDING PRIMER
AND DTM ACRYLIC COATING PAINT. SEMI -GLOSS FINISH. (COLORS BY AU BON PAIN).
ro.
ALL HARDWARE AND FRAMES SHALL MAINTAIN THE INTEGRITY OF THE FIRE RATING OF THE
DOORS.
�•
PROVIDE SMOKE TIGHT CAULKING AROUND ENTIRE PERIMETER OF FRAMES.
8.
USE DOUBLE (ATTACHED) 20 GAUGE METAL STUDS AT JAMB OF ALL DOOR OPENINGS IN
METAL STUD PARTITIONS.
9.
CONTRACTOR SHALL FIELD VERIFY THICKNESS OF ALL EXISTING PARTITIONS
ACCOMMODATING NEW DOORS IN ORDER TO DETERMINE THE 'THROAT" DIMENSIONS OF
NEW FRAMES.
10.
SEE FLOOR PLAN FOR EXACT DOOR SWING.
11.
NO KNOCK -DOWN FRAMES SHALL BE PERMITTED THROUGHOUT.
12.
FOR DOOR JAMB, HEAD AND SILL DETAILS, SEE SHEET A-5
13.
ALL WOOD DOORS TO BE SOLID CORE UNLESS OTHERWISE NOTED. SEE SPECIFICATIONS.
14.
ALL DOORS SHALL BE PROVIDED WITH A 5/8' UNDERCUT. MAXIMUM CLEARANCE BETWEEN
CITY OF SOUTH MIAMIr
THE BOTTOM OF THE DOOR AND THE CONCRETE SLAB SHALL BE 3/4" MAX. EXCEPT AT
BUILDING DEpt
THRESHOLD CONDITIONS.
,
STRUCT
RA SECTION
15.
CONTRACTOR SHALL VERIFY SIZE OF ALL DOOR OPENINGS AND CONTACT THE ARCHITECT
APPROVED
IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING DOORS AND/OR FRAMES.
�41�y
16.
ALL "B" LABELED STAIR DOORS TO BE 450` TEMP. RISE IN 30 MINUTES.
1-1.
USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED).KNURLED
LEVER HANDLES SHALL BE PROVIDED AT ALL TELEPHONE CLOSETS, MECHANICAL AND
ELECTRICAL ROOMS.
18.
DOOR HANDLES SHALL BE MOUNTED a 48' A.F.F. (MAXIMUM).
APPROVED
19.
DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10 DEGREES,
By
MIAWDADE C0UHT,
THE DOOR WILL TAKE AT LEAST 3 SECONDS TO CLOSE TO A POINT 3 INCHES FROM THE
FfRf DEP RT4fNr
LATCH.
$ --,—BLDG. MR--r'
WATER AIN EXTEN N
20,
THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS :
°At eY
a) REQUIRED FORCE FOR EXTERIOR HINGED DOORS IS = 8.5 Ibf
b) REQUIRED FORCE FO INTERIOR HINGED DOORS 15 = 5 Ibf
c) REQUIRED FORCE FOR SLIDING OR FOLDING DOOR IS = 5 Ibf
21,
ALL DOORS IN THE MEANS OF EGRESS SHALL BE SINGLE ACTION RELEASE, SHALL COMPLY WITH F.A.C.AND
SHALL NOT REQUIRE THE USE OF A KEY, TOOL OR SPECIAL KNOWLEDGE TO OPEN FROM THE EGRESS SIDE.
EXISTING
IMPACT
RESISTANT
DOOR AND
GLAZING
DOOR TYPES
O
FLUSH
ro"x12"SAS
PUSH PLATE
12, H. SAS
KICK PLATE
el -FOLD/
HALF LOUVER
PLASTIC
LAMINATE
ClwIt21 I
FLOOR
— LINE
Cx-1 Ca-2
_R
Ravbbnx
0
0
1-s
Orr
'
get
<z
ci!
p
LLA
x �'
Z
�<
2 ..a
CLO
xu
z
�Q
Q W
r-
®
V)2
3��v
DRAWN OLP
CHECKEDs LEN
DAlEt 02-18-08
SCAM NTS.
SEAL ` � �QF.: � •� � ��..
4.
Sheet No.
A-5
CIF
9
JOB $ 2-1033