Loading...
08-985-007I a 00 N 00 O 0 N O 3 - a If) U O 0 M O n - 0 a _ hl DOOM DETAIL& 5/8' CEMENTITIOUS n u YPE 'X' WALLBOARD WITH GYPSUM ' SCHEDULED FINISH F_R.P. PANELS WALLBOARD —� ON 5/8' DRYWALL 2 METAL STUDS 3 5/8' GALV. CAULK (TYP. EACH CONT. GALV. STEEL STUDS 16' O.O. FLOOR FINISH MARBLE SILL CERAMIC SIDE) RUNNER SEE FINISH ON THIN SET TILE ON THIN HOLLOW METAL FRAME SCHEDULE SET CONT. P.T. 1 X 4 3 CLIPS PER JAMB � ZING CORNER 4 ,...- . VA RIES lu SQUARE EDGE if CASING BEADS zz GALV. HEAVY 1 1 cD N SEALANT DUTY STEEL 1/2'2 2 I u.� W TRACK 4 BALL I z WOOD BI -FOLD BEARING TRACK DOORS PER ASSEMBLY SCHEDULE Q- FINISH FLOOR NOTE: t- (SEE SCHEDULE) s THRESHOLD SHALL NOT HAVE 2" 5�8' ANY CHANGE IN GREATER THAN 1:2LSLOPE.N J-1 H-1 JAMB DETAIL MEAD SIMILAR N.T.S. H-2 BI -FOLD DOOR HEAD DETAIL N.T.S. T-1 THRESHOLD DETAIL N.T.S. 151A BY PEMKO f NEW FLOORING 3' if 1/4' EXISTING CONCRETE SLAB No. 10 x 1-1/2" FHWS, PHILLIPS (FACTORY PROVIDED) = COLOR SELECTION AND 151A HALF SADDLE, 1/4' X FINISH BY OWNER 3', FLUTED -2 T'HRE514OLD DETAIL_ N.T.S. FRAME HEAD RABBET HINGE 4: DEADLOCK STRIKE � HOSPITAL ARM PULL (LOWER BASE) AND PUSH PLATE 4. PUSH BAR AND PULL (t STRIKE FOR KNOB LOCKS, HANDLE SETS. ROLLER LATCHES 4 EXIT DEVICES ct HINGE SCHEDULED FLOOR BOTTOM OF FRAME TYPICAL DOOR DETAIL. N.T.S. DOOP SCHEDULE 00 DOOR p00R DOOR DOOR SIZE _ FRAME DETAILS HDW. LABEL AUTO.- ^ ^ ^ l l No. No. TYPE MAT. 1" 1AT. SET NO. ASSEM. POOR. (A.D.) RE1"1ARKS - - - - , - - - - - _ - WTH. HGT. TH. JAi" IB HEAD TRESH. 100 100 A ALJGL. 3'-0' 1'-0' 1 3/4' ALUM. _ - - = EXISTING W/ DOOR Cl..OSER 101 101 8 WOOD 3'-0' 1'-0' 13/4' METAL J-1 H-1 T-2 - - - IOIA 101A C WOOD 2'-0' 1'-0' 13/4 - = H-2 - - - - 102 102 B WOOD 3'-0' -1'-0' 13/4 HM J-1 H-1 T-1 - - _ LOCATED EXISTING DOOR WITH 103 NOT USE 104 104= B= WOOD* 3'-0' 1'-0' 13/4 HM = _ _ - - - = EXISTING W/ DOOR CLOSER 100 105 B METAL 3'-0' 1'-0' 1 1 3/4' HM = _ _ - - 8 EXISTING W/ DOOR CLOSER 105 G_1 4 2 - I PLYWD. 2'-8' 21-VT 1' - - - - - - - WITH AUTOMATIC CLOSER DOOR NOTES 1. ALL DOORS AS SHOWN ON FLOOR PLANS ARE EXISTING TO REMAIN. 2. CONTRACTOR SHALL NOTIFY ARCHITECT IF ANY EXISTING DOORS (FIRE RATED OR OTHEWISE) ARE FOUND DEFECTIVE OR NOT MEETING STANDARDS SET IN THIS CONSTRUCTION DOCUMENT SET. 3. ALL EXISTING DOORS HAVE ACCESSIBLE HARDWARE. 4. DOOR NUMBERS CORRESPOND WITH ROOM NUMBERS FOR EASE OF IDENTIFICATION. SEE FLOOR PLANS FOR LOCATIONS. 5. DOORS, JAMBS, AND TRIM TO BE PAINTED WITH DTM BONDING PRIMER AND DTM ACRYLIC COATING PAINT. SEMI -GLOSS FINISH. (COLORS BY AU BON PAIN). ro. ALL HARDWARE AND FRAMES SHALL MAINTAIN THE INTEGRITY OF THE FIRE RATING OF THE DOORS. �• PROVIDE SMOKE TIGHT CAULKING AROUND ENTIRE PERIMETER OF FRAMES. 8. USE DOUBLE (ATTACHED) 20 GAUGE METAL STUDS AT JAMB OF ALL DOOR OPENINGS IN METAL STUD PARTITIONS. 9. CONTRACTOR SHALL FIELD VERIFY THICKNESS OF ALL EXISTING PARTITIONS ACCOMMODATING NEW DOORS IN ORDER TO DETERMINE THE 'THROAT" DIMENSIONS OF NEW FRAMES. 10. SEE FLOOR PLAN FOR EXACT DOOR SWING. 11. NO KNOCK -DOWN FRAMES SHALL BE PERMITTED THROUGHOUT. 12. FOR DOOR JAMB, HEAD AND SILL DETAILS, SEE SHEET A-5 13. ALL WOOD DOORS TO BE SOLID CORE UNLESS OTHERWISE NOTED. SEE SPECIFICATIONS. 14. ALL DOORS SHALL BE PROVIDED WITH A 5/8' UNDERCUT. MAXIMUM CLEARANCE BETWEEN CITY OF SOUTH MIAMIr THE BOTTOM OF THE DOOR AND THE CONCRETE SLAB SHALL BE 3/4" MAX. EXCEPT AT BUILDING DEpt THRESHOLD CONDITIONS. , STRUCT RA SECTION 15. CONTRACTOR SHALL VERIFY SIZE OF ALL DOOR OPENINGS AND CONTACT THE ARCHITECT APPROVED IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING DOORS AND/OR FRAMES. �41�y 16. ALL "B" LABELED STAIR DOORS TO BE 450` TEMP. RISE IN 30 MINUTES. 1-1. USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED).KNURLED LEVER HANDLES SHALL BE PROVIDED AT ALL TELEPHONE CLOSETS, MECHANICAL AND ELECTRICAL ROOMS. 18. DOOR HANDLES SHALL BE MOUNTED a 48' A.F.F. (MAXIMUM). APPROVED 19. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10 DEGREES, By MIAWDADE C0UHT, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO CLOSE TO A POINT 3 INCHES FROM THE FfRf DEP RT4fNr LATCH. $ --,—BLDG. MR--r' WATER AIN EXTEN N 20, THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS : °At eY a) REQUIRED FORCE FOR EXTERIOR HINGED DOORS IS = 8.5 Ibf b) REQUIRED FORCE FO INTERIOR HINGED DOORS 15 = 5 Ibf c) REQUIRED FORCE FOR SLIDING OR FOLDING DOOR IS = 5 Ibf 21, ALL DOORS IN THE MEANS OF EGRESS SHALL BE SINGLE ACTION RELEASE, SHALL COMPLY WITH F.A.C.AND SHALL NOT REQUIRE THE USE OF A KEY, TOOL OR SPECIAL KNOWLEDGE TO OPEN FROM THE EGRESS SIDE. EXISTING IMPACT RESISTANT DOOR AND GLAZING DOOR TYPES O FLUSH ro"x12"SAS PUSH PLATE 12, H. SAS KICK PLATE el -FOLD/ HALF LOUVER PLASTIC LAMINATE ClwIt21 I FLOOR — LINE Cx-1 Ca-2 _R Ravbbnx 0 0 1-s Orr ' get <z ci! p LLA x �' Z �< 2 ..a CLO xu z �Q Q W r- ® V)2 3��v DRAWN OLP CHECKEDs LEN DAlEt 02-18-08 SCAM NTS. SEAL ` � �QF.: � •� � ��.. 4. Sheet No. A-5 CIF 9 JOB $ 2-1033