08-985-0012
Affiliate of
South Miami
Hospital
Health Systems of South Flori
GENERAL NOTES
I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF
DOCU IENTSJ CONTRACTOR IS RESPONSIBLE FOR PROVIDING
SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT
IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH
UTILITY CONNECTIONS AS REQUIRED FOR OPERATION.
EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS,
THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS
CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS
IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF
THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO-
VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW-
NER.
2.- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING
THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE
AS DESCRIBED IN THE DOCLMENTS. DISCREPANCIES ARE TO
BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS.
CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE,
AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE
CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER.
3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL THEY TAKE
AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON-
TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS
RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE
TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE
RE -DONE.
4.- SHUTDOWN OF UTILITIES$ IF A SHUTDOWN OR ANY TYPE OF INTBR-
FEIPEVCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAC
TOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA-
IN APPROVAL IN WRITING PRIOR TO PROCEEDING.
5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND
USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES
TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT
NOTED FOR REMOVAL CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND
SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER.
6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION
DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP
DURING THE CONSTRUCTIORIT IS ASSUMED THE CONTRACTOR BID
THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE
DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST
TO THE OWNER.
7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM-
MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION.
8.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY
BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER
EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE
PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC _
TION CONTRACT.
9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL
OPENINGS FOR MECHANICAL, ELECTRICAL AND PLLWING EQUIPMENT
WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED
BY ARCHITECT, BEF012E PROCEEDING WITH THE WORK
10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED
HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES
AS TO APPLICATION AND USE
II.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL
AND ALSO BETWEEN CEMENT AND METAL
12.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMITS TO COMPLETE THE PROJECT.
13.- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR
COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY
SING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION.
14.- GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO
WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK,
EQUPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/
REPLACED TO MATCH EXISTING (TYPICAL LNLESS OTHERWISE NOTED).
15.- DRAWINGS ARE SC14EMATIC SHOWING RELATIVE LOCATIONS AND
CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME
16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE -
RETARDANT TREATED AS PER SPECIFICATIONS.
17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS /
PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL LPGRADE
EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY
OF TI-E DESIGNATED RATING.
18.- ELEVATION AND LEVELS,
A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB.
UNLESS NOTED OTHERWISE
19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL
STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS
DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF
WATER RESISTANT G.WB.
20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS.
AND JANITOR'S CLOSETS,
2L- BEFORE PATCHING ANY F112E - RATED CMU PARTITION. FILL ANY
EXPOSED CELLS SOLID WITH GROUT.
22.- PROVIDE FINISH WALL U\VER AND BEHIND ALL EQUIPMENT AND CASEWORK
23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE
DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND
ELECTRICAL ITEMS WI4104 REQUIRE ACCESS. THE CONTRACTOR SHALL
COORDINATE WITH ALL TRADES, THE ARCHITECT SHALL REVIEW AND
APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO
INSTALLATION.
24.- T1-E•12E SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE
OR OTHER OUTLETS.
25.- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE
FUZRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH
ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS
A. ELECTRIC CLOSETS C. MECHANICAL ROOMS
B. TELEPHONE CLOSETS D. STAIRS
26.- WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS
PENET12AT E PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO
STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL
PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE
FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH
APPROPRIATE FIRE S.T.0 MATERIAL
27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTE12ICQ
SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR
ACOUSTICAL TILE FINISH.
28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF
CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES.
29.- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.WB. PARTITIONS
EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 7-07.
UNLESS OTl-1ERWISE NOTED.
30. CONIT12ACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED
STEEL COMPLIES WITH N.FP,A FIRE PROTECTION REQUIRE-
MENTS. CONTRACTORSHALL PROVIDE ALL NECESSARY INSUJ_A-
TION/FIRE PROTECTIVE COATINGS.
31. CONTRACTOR TO SUBMIT ALL SHOP DRAWING TO ARCHITECT AND
THE BUILDING DEPARTMENT FOR APPROVAL (ELEVATOR, TRUSSES,
WINDOWS, E:TCJ
3Z CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT.
AU BON PAIN RESTAURANT
SOUTH MIAMI HOSPITAL
MEDICAL ARTS BLiILDING
6200 S.W. 73 STREET SOUTH MIAMI, FLORmA 33143
TEL: (sos) 663-soya Fax: (786) 596-8010
L9 EB0000924
LOUIS J. AGUIRRE & ASSOCIATES P.A.
CONSULTING ENGINEERS
2600 DOUGLAS RD. SUITE 605
CORAL GABLES, FLORIDA 33134
TELEPHONE: (305) 444-1679
FAX: (305) 448-1405
E-MAIL ADDRESS: GRALMAIL@LLJAAPA.COM
CITY MAP
L"07 Ell raw
I/ �. li � ���ii��%f�plwll�M�■� ��tA
f
AREA MAP
Sort f7noolo Ago
INTERIOR REMODELING ONLY
FEBRUARY 18, 2008
o � A 0
architects
FLORIDA LICENSE +AA0002689
7400 N.W. 7th Street Suite fOf Miami, Florida. 3312,E
Teh (305)265-7177 Fax: (305)2624;435
LUIS E. NAYA, AJ.A FL AIt0008063
PROJECT NUMBER: 27033
INDEX OF DRAWINGS
ARCHITECTURAL
A-1 DEMOLITION PLAN, LEGEND AND NOTES.
A-2 FLOOR PLAN, LEGEND AND NOTES.
A-3 REFLECTED CEILING PLAN, LEGEND AND NOTES.
A-4 EQUIPMENT PLAN, INTERIOR ELEVATIONS, LEGEND AND NOTES.
A-5 DOOR SCHEDULE, NOTES AND DETAILS.
A-6 FINISH SCHEDULE, DETAILS, NOTES AND PARTITION TYPES.
A-7 PENETRATIONS AND FIRE RATING DETAILS.
A-8 PENETRATIONS AND FIRE RATING DETAILS.
A-9 PENETRATIONS AND FIRE RATING DETAILS.
14711 p(s) ._za
MO.00 SYMBOLS LEGEND, AND GENERAL, NOTES - HVAC.
M3.00 DEMOLITION FLOOR PLAN - HVAC.
M3.01 DEMOLITION FLOOR PLAN - CHILIED WATER PIPING - HVAC.
M3.02 FLOOR PLAN - HVAC.
M3.03 FLOOR PLAN - CHUM WATER PIPING - HVAC.
M7.00 DETAILS - HVAC.
PO.00 SYMBOLS LEGEND, AND GENERAL NOTES.
P3.00 FLOOR PLAN AND PARTIAL DEMOLITION FLOOR PLAN.
P5.00 DOMESTIC HATER AND SANITARY ISOMETRIC RISER DIAGRAM.
P7.00 DETAILS.
BUILDING INFORMATION
MADE
ONVol04
EO.00 SYMBOLS LEGEND, GENERAL NOTES AND LIGHTING
FIXTURE SCHEDULE.
E3.00 DEMOLITION FLOOR PLAN LIGHTING.
E3.01 DEMOLITION FLOOR PLAN POWER.
E3.02 FLOOR PLAN - LIGHTING.
E3.03 FLOOR PLAN - SYSTEMS.
E5.00 RISER DIAGRAM.
E6.00 PANEL BOARD SCHEDULES.
FIRE PROTECTION
FPO.00 SYMBOLS, LEGEND AND GENERAL NOTES.
FP3.00 FLOOR PLAN.
ORIGINAL BUILDING DESCRIPTION
BUILDING Q
JURISDICTION : SOUTH MIAMI, MIA MI DADE COUNTY 0
PRIMARY USE CLASS : GROUP "S" SPECIAL STORAGE OCCUPANCY
NUMBER OF STORIES : 9 LEVELS (OPEN AUTOMOBILE PARKING GARAGE) Q
NEW PROJECT DESCRIPTION 0
PROJECT AREA: : TOTAL: 1, 800 S.F.
SPREM ED : FULLY SPRIINELERED Q
APPLICABLE CODES
FLORIDA BUILDING CODE 2004 EDITION Q
FLORIDA FIRE PREVENTION CODE 2004 EDITION
REVISIONS
FIRST
ABBREVIATI-0N-F_%,-7nE
I AND
L
L ANGLE
• AT
L
LENGTH
C CENTERING-1
LAM
LAMINATE
O DIAMETER
LAV
LAVATORY
• POUND OR NUMBER
LBS
POUNDS
A
LBS/HR
POUNDS PER HOUR
LD
LINEAR DIFFUSER
A/C
AIR CONDITIONING
LP
LOW POINT
ACI
AMERICAN CONCRETE INSTITUTE
LT
LKaHT
ACP
ASBESTOS CEMENT PIPE
M
ACSC
ASPHALTIC CONCRETE SURFACE COURSE
ACU
AIR CONDITIONING UNIT
ACT
ACOUSTICAL CEILING TILE
MAIL
MATERIAL
AD
AREA DRAIN
MAX
MAXIMUM
ADJ
ADJUSTABLE
MC
MEDICINE CABINET
A/E
ACCESS
MEC 4
MECHANICAL
AF
FLOORING
A�� FLOOR
MEMB
MFR
MEMBRANE
MANUFACTURER
AG
ABOVE FINISI$D FLOOR
MIN
MIN
MINIMUI
AMR
ALT
AG
AGGREGATE
AIR HANDLING WIT
MISCELANEOUS
ALT
ALTERNATE
MO
MASONRY OPENING
AL
ALUMINUM
i MTD
MOLNTED
ANN
ANNUNCIATOR
M
PETAL
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
MUL
MULLION
ANT
ANTENNA
MOLT
MULTIPLE
AP
ACCESS PANEL
N
APL
ACCESS PLENUI
APROX
APPROXIMATE
ARCH
ARCHITECTURAL
N
NORTH
ASB
ASBESTOO
NEC
NATIONAL ELECTRIC CODE
ASPH
ASPHALT
NIC
NOT IN CONTRACT
ASTM
AMERICAN SOCIETY OF TESTING t MATERIALS
NO
NUMBER
d
ROM
NOMINAL
NPL
NAME PLATE
BAT
BATTERY
NTS
NOT TO SCALE
BD
BOARD
0
BITUM
BITUMINOUS
BLDG
BUILDING
BLKG
BLOCKING
CIA
OVERALL
BM
BEAM
OBS
OBSCURE
BOT
BOTTOM
OC
ON CENTER
OD
OUTSIDE DIAMETER DIM)
co
OF$
OVERFLOW SCUPPER
CAB
CABINET
i OPP
OPPOSITE
CB
CATCH BASIN
CENT
NIT
CEMENT
CER
CERAMIC
CFM
CUBIC FEET PER MIWTE
PC
PRECAST CONCRETE
CG
CORNER GUARD
Pi
PIPE JOINT
C-IP
CRICKET HIGH PONT
PL
PLASTIC
Cl
CIC
CAST IRON
CAST IRON COVER
P LAM
PLASTIC LAMINATE
CI
ClioCAST
IROW PIPE
PLAS
PLASTER
CJ
CONoL JOINT
PLYWlD
PLYWOOD
CLG
CEILING
PINT
PT
PAINT
POINT OR PATIENT
CLGD
CEILING DIFFUSER
PTD
PAPER TOWEL DIBPENCER
CAULKING
PTN
PARTITION
CLO
CLOSET
PTR
PAPER TOWEL RECEPTACLE
CLP
CRICKET LOW POINT
CLR
CLOSER
CMP
CORRUGATED METAL PIPE
Q
CMU
CONCRETE MASONRY WIT
C
COUNTER
CRT
CIUARTER
CO
CLEAN OUT
QT
QUARRY TILE
COL
COLUMN
COMA
COMMUNICATION
CONO
CONCRETE
R
CONN
CONNECTION
CONSTS
CONSTRUCTION
R
REAR
CONT
CONTINUOUS
I"
RETURN AIR
CPT
CARPET TILE
RAD
RADIUS
CT
CERAMIC TILE
RB
REIFORCED BEAM
CTR
CENTER
RCPT
RECEPTION
CTSK
COUNTERSINC
RD
ROOF DRAIN
O
REF
(REFERENCE
REINF
REINFORCED
REQ
REOUIRED
DBL
DOUBLE
RESL
RESILIENT
DEG
DEGREE
RGTR
REGISTER
DEPT
DEPARTMENT
RM
ROOM
DESK,
DESIGNATION
RD
ROUGH OPENING
DET
DETAIL
RWL
RAN WATER LEADER
DF
DRINl FOUNTAIN
DG
DOOR GRILLE
VIA
DIAMETER
d
DIAL
DIAGRAM
DIM
DIMENSION
DISR
DISPENSER
S
STUCCO
ON
DOWN
SC
SCREED CONCRETE
DO
DOOR OPENING
SCHED
SCHEDULE
DSP
DRY STANDPIPE
SEC
SECOND
Ds
DOWN SPOUT
SD
SHOM DETECTOR
Daw
DRq1*46
SECT
SECTION
DW2
DRAWER
SF
SUPPLY FAN
SG
SPANDREL. GLASS
SGR
SYNTHETIC GRADE
SWR
SWOUER
EA
EACH
am
8-EET
EC
EPDXY COATING
SIG
SIM
SIGNAL
SIMILAR
END
ELECTRIC NAND DRYER
SK
6I NK
EL
ELEVATION
SM
SHEET METAL
EJ
EXPANSION JOINT
SINK
SMOKE
ELEC
ELECTRICAL
8ND
SOUND
ELEV
ELEVATOR
SPEC
SPECIFICATION
EMER
EMERGEINCY
SPKR
SPEAKERS
ENCL
ENCLOSURE
SQ
Salc•RE
ENGR
ENGINEER
SCAT
SCIUARE FEET
EPIC
ELECTRICAL PANEL
SST
STAINLESS STEEL
EQ
EQUAL
ST
STREET
EQPT
EQUIPMENT
STC
SOUND TRANSMISSION COEFFICIENT
EST
ESTIMATE
STD
STANDARD
ET
EXPANSION TAW.
ST-D
STORM DRAIN
EWC
ELECTRIC WATER COOLER
STL
STEEL
EXH
EXHAUST
STRL
STRUCTURAL
EXST
EXISTING
SUSP
SUSPENDED
EXT
EXTERIOR
SYM
SYMMETRICAL
SYS
SYSTEM
T
FA
FIRE ALARM
FABL
FIRE ALARM BELL
T
TOILET
FD
FLOOR DRAIN
TB
TIE BEAM
FG
FIBERSL.ASS
TC
TIE CMAPN
FCO
FLOOR CLEANOUT
TEL
TELEPHONE
FD
FIRE DAMPER
TEMP
TEMPERATURE
FDC
FIRE DEPARTMENT CONNECTOR
T*G
TONGUE AND GROVE
FDR
FIRE DOOR
THK
THICK
FDN
FOUNDATIONS
TOG
TOP OF CURB
FDV
FIRE DEPARTMENT VALVE
TOPP
TOP OF PARAPET
FEC
FIRE EXTINGUISHER CABINET
TOO
TOP OF SLAB
FEX
FIRE EXTNGIISHER
TP
TOP OF PAVEMENT
FIX
FINISH FLOOR
TRD
TREAD
FH
FIRE HYDRANT
TS
TUM LAR STEEL
FIN
FINISH
TSTAT
THERMOSTAT
FL
FLOOR
TV
TELEVISION
FM
FACTORY MANUAL
TW
TOP OF
FLASH
FLASHING
TYP
TYPICAL
FL.G
FLANGE
FLOUR
FLUORESCENT
U
FOG
FACE OF CONCRETE
FOF
FACE OF FINISH
US
UNDERCUT
FOM
FACE OF MASONRY
UL
UNDERWRITE" LABORATORIES
FOS
FACE OF STUD
UNF
UNFINISHED
FPRF
FIREPROOF
UON
UNLESS OTHERWISE NOTED
FPM
FEET PER MINUTE
UOS
UNLESS OTHER SPECIFIED
FRD
FRENCH DRAIN
UR
URINAL
FS
FULL 812E
UTIL
UTILITY
FT
FOOT OR FEET
v
FTG
FOOTING
FT-LD
FOOT POUNDS
FURR
FURRING
VB
VINYL. BASE
FUT
FUTURE
VCT
VINYL COMPOSITION TILE
VERT
VERTICAL
d
VEST
VESTIBULE
VF
VERIFY N FIELD
1V/TT
VOLUME ,
GA
GAUGE
VAPOR TIGHT
GAL
GALLON
VTR
VENT THRUROOF
GALV
GB
GALVANIZED
GRADE BEAM C
GEN
GENERATOR 4`I�Y OT SOU�H P7AM
�
GROUND SUILASSDI G
WR
WIRE
GLB
GLASS BLOCK
TION
W
WINDOW
GR
GRILLE
E STRUCT
L S
We
WATER CLOSET
CUM
GYPSUM WALL BOARD
WCO
WALL CLEANOUT
GYP
GYPSUM
LLD
U F
WOOD
WALL FABRIC
L{
APPROVE[)WP
W/O
w5CT
WITHOUT
WATER PROOF
WAINSCOT
WT
WEIGHT
1,415
HOSE BIB
W1F
WELDED WIRE FABRIC
HG
HDWD
HANDICAPPED pgjA; �_.,
HARDWOOD
WUUM
WELDED WIRE MESH
NDUE
WIT
HARDWARE
HEIGHT
HIM
HOLLOW METAL
HORIZ
HORIZONTAL
NP
HIGH PORT
HR
HOUR
HTR
I -EATER
HVAC
HEATING, VENTILATION, AND AIR CONDITIONING
HYD
HYDRANT
'D
INSIDE DIAMETER C DIAM)
�--
IT
NNNR
INCHES
IR
t ` p F -Pi
N'
JAN
JB
JOT
JSK
JT
KKID
JANITOR
JUNCTIB ON OX
J UNCTIOIN
JANITORS SINK
JOINT
A.U►-