08-985(2)-021NEAT 1 HOT W SUPPL' PST9 Aby� ELECTRIC WA7 DUNG FROM J( HIGH AS POSS DRAIN V SAFET 1 1/2" MI DEPTH SHUT-OFF GATE VALVE COLD WATER SUPPLY TO HEATER PROVIDE 2 GAL. THERMAL EXPANSION TANK 3/4"PET RELIEF LINE PROVIDE AIR GAP FITTING IF TERMINATING OUTSIDE ROOM. aU /ten TERMINATE 11/2" OVER 3/4" PAN SERVICE SINK FLOOD RIM DRAIN LINE LEVEL OR EXTEND TO THE EXTERIOR OF THE BUILDING AND TERMINATE POINTING DOWN 6" ABOVE FINISHED GRADE, NO ADDITIONAL NEAT TRAPS REQUIRED WHEN WATER HEATER HAS INTEGRAL HEAT TRAPS. TYPICAL WATER HEATER DETAIL N.T.S. COVER SECURED WITH SCREWS THREADED C.O. PLUG FIN. GRADE 1 4 X 6" DIA, CONCRETE PAD FLUSH W/FIN. GRADE EXTERIOR TYPE TYPICAL CLEANOUT DETAIL N.T.S. JOINT F System No. C-AJ-1156 F Rating -- 3 Hr T Rating -- 0 Hr L Rating At Ambient -- Less Than 1 CFM/sq ft L Rating At 400 F -- 4 CFM/sq ft A- II Il"T A P"11 r l"./\I 1 AM i A acv I TWIN n-n FLOOR 1. Floor or Wall Assembly -- Min 4-1/2 in. thick reinforced lightweight or normal weight (100 to 150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 27 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Steel Pipe -- Nom 21 in. diam (or smaller) 0.056 in. thick (or heavier) steel pipe. One pipe to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. (point contact) to max 3 in. Pipe to be rigidly supported on both sides of floor or wall assembly. 3. Firestop System -- The firestop system shall consist of the following: A. Steel Wire Mesh -- (Not Shown) -- Where needed to aid in system installation in concrete block wall construction, No. E steel wire mesh or min 0.034 in. thick (20 MSG) gals sheet steel may be formed, centered and installed within the through opening such that it is recessed a min of 1/8 in, from each surface of the wall, B. Packing Material -- Min 2 in. thickness of min 4.0 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material. C. Fill, Void or Cavity Material* -- Sealant -- Min 3/4 in, thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. At the point contact location between pipe and concrete, a min 1/2 in. diam bead of caulk shall be applied at the concrete/pipe interface on the top surface of floor and on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS-ONE Sealant *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of c�PSSe I Fj�Q Underwriters Laboratories, Inc. FIRESTOP SYSTEMS November24,1999 Cus 1/2" MIN, FLUSH VALVE LEFT OR RIGHT AS APPLICABLE (CONTR'S OPTION) FIXTURE WALL HUNG OR FLOOR MTD, AS APPLICABLE DRAIN FINISH FLOOR NON-FERROUS -- — ZOOM SLOPE DOWN TO OUTLET • 1/87FT WJ NO TRAP OR INTERMEDIATE LOW POINTS. ALTERNATE CONN. (CONTR'S. OPTION) SYSTEM DIAGRAM ALL EXPOSED COMPONENTS CHROME PLATED AND / OR STAINLESS STEEL (SLOAN F-72-AU FLUSH VALVE TRAP PRIMER DETAIL (F.V.P.; N.T.S. �— FACE OF WALL WALL STAINLESS STEEL COVER SCREWED TO THREADED C.O. PLUG, System No. W-L-1054 F Ratings -1 and 2 Hr (See Items 1 and 3) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/Sq Ft L Rating At 400 F - 4 CFMlSq Ft Z:TION A -A PLUMBING FIXTURE COLD WATER TO FIXTURE PIMER VALVE JOSAM a88250-10 OR APPROVED EQUAL W/ VACUUM BREAKER. NOTE: ALL EXPOSED PLUMBING ITEMS, SHALL BE CHROME PLATED FLOOR DRAIN PARTITION OR CHASE C.W. SUPPLY TO PLUMBING FIXTURE FIXTURE VALVE ESCUTCHEON PLATES (SEAL PARTITION OPENINGS) FINISH FLOOR PENETRATION —UN. SLEEVE E SEAL AS REQUIRED 1/2" MIN. ALTERNATE BY LOCATION CONN'S. (CONTRACTOR'S (REFER TO OPTION) SLOPE DN. TO DETAIL) OUTLET • 1/8" FT. W/ NO TRAP OR INTERMEDIATE LOW POINTS, EWNOTE: USED WHERE NO SUITABLE WATER CLOSET, ELECTRIC WATER COOLER, OR DRINKING FOUNTAIN IS WITHIN 30 FEET. TRAP PRIMER VALVE DETAIL (T.P.V.) N.T.S. NOTES: A. SLOPE DRAIN LINE TO CONDENSATE RECEPTOR (MIN. 1/8" PER FOOT) B. DRAIN LINE SHALL BE COPPER TYPE "L" AND INSULATED C. TSP - FAN TOTAL STATIC PRESSURE D. PROVIDE CONDENSATE OVERFLOW SAFETY SWITCH TO TURN OFF THE UNIT IF DRAIN PAN APPROACHES OVERFLOW. A/C CONDENSATE P-TRAP DETAIL. N.T.S. 1. Wall Assembly -- The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory. 2. Through -Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2-1/4 in. Pipe may be installed with continuous point contact. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -- Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe — Nom 30 in. diam (or smaller) cast or ductile iron pipe. C. Conduit -- Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. D. Copper Tubing -- Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe -- Nom 6 in. diam (or smaller) regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -- Sealant -- Min 5/E in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe watt interface on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS-One Sealant *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of ��SS I FjFQ Underwriters Laboratories, Inc. FIREST010 SYSTEMS December 4, 2002 C m � us A.N.U. AUXILIARY DRAIN PAN SSURE IN PAN. : � Or I M t SM0 WCO GREASE TRAP SIZING CALCULATION FIXTURE #k FIXTURES FIXTURE VALUE (GPM) TOTAL FIXTURE (GPM) AVERAGING MULTIPLIER FLOW RATING (GPM) 3 COMPARTMENT SINK 1 25 25 0.25 6.25 * CALCULATION BASED ON BIG DIPPER "SIZING BIG DIPPER SYSTEMS IN FOOD SERVICE OPERATIONS" PHAMPLET. SINGLE FIXTURE BIG DIPPER EQUIPMENT MODEL GPM RATING W-150-IS 15 RESILIENT TYPE NCRETE INSERT THRU 8" PIPE SIZE /F.M. APPROVED. GRINNELL FIG, /285 OR APPROVED EQUAL THREAD ROAD - � d THICK X 12" LONG SLEEVE iEOPRENE FOAM (RUBATEX )R ARMFLEX) RIPE RING I" GREATER THAN 1IPE O.D. GAUGE X 12" LONG GALVANIZED STEEL PIPE SHIELD PIPE HANGER DETAILS N.T.S. :ONCRETE ANCHOR SELF DRILLING I.L. LISTED THRU 4" PIPE SIZE ROAD COUPLING, U.L./F,M. GRINNELL 136 OR APPROVED EQUAL ALL THREAD ROAD IPE RING TOP BEAM C TYPE CLAMP U.L./F.M. APPROVED THRU 6" PIPE SIZE. GRINNELL FIG, 86 OR APPROVED EQUAL ALL THREAD ROD RIPE RING GRINNEL FIG. 69 J.L./F.M. APPROVED (TYP) Revisions: 0 A M o 0 LO o a v JU U_ < z VJ0 W Om t r V) <cr— J In =< Z OW M � n I M co �to O Q o cli " � W u N a M vC4 CE 0 U �9� 0a"E,=S ° C4 a o -4-1 �N t -cl 6 cn c� nor L r �c ©.,Uz U0:5 o O g V) Q W 0 n DRAWN: JB CHECKED: E3 DATE: 02-I0-Oa SCALE: AS NOTED SEAL MEC ANI A"L: ERNESTO ANTANA P-E, LICENSE► 60788. Sheet No. P7.00 JOB # 21033