08-985(2)-018PLUMBING GENERAL NOTES: I. ALL WORK SHALL COMPLY WITH ALL LOCAL LAWS AND REGULATIONS AND THE FLORIDA BUILDING CODE. ALL MATERIALS AND WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY. 2. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE PLUMBING SYSTEMS, ALL IN ACCORDANCE WITH THESE CONSTRUCTION DOCUMENTS. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2004, ALL APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES, AND ALL THE STANDARDS OF CONSTRUCTION ESTABLISHED BY THE EXISTING INSTALLATION. 3. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE OF THE WORK AND BECOMING FAMILIAR WITH THE CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. THE CONTRACTOR IS REQUIRED TO BECOME FAMILIAR WITH ALL THE CONTRACT DOCUMENTS PERTAINING TO THE PROPOSED WORK. THE SUBMISSION OF A BID SHALL BE SUFFICIENT TO ESTABLISH THAT THE CONTRACTOR HAS INVESTIGATED THE SITE OF THE WORK AND IS SATISFIED AS TO ALL REASONABLE CONDITIONS TO BE ENCOUNTERED, THE WORK TO BE PERFORMED AND THE MATERIALS TO BE PROVIDED IN THE COMPLETION OF THE PROJECT. 4, FAILURE OF BIDDERS TO MAKE REQUIRED VISITATIONS AND/OR INVESTIGATIONS TO INFOW THEMSELVES FULLY OF EXISTING CONDITIONS, AND TO INCLUDE IN THEIR PROPOSALS A SUM SUFFICIENT TO COVER ALL POSSIBLE FIELD CONDITIONS, WILL NOT IN ANY WAY ENTITLE THEM TO ANY EXTRA CHARGES OVER AND ABOVE THEIR ORIGINAL PROPOSALS. 5. IT IS THE INTENT OF THE PLANS AND GENERAL NOTES TO PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL NECESSARY ITEMS REQUIRED, EVEN THOUGH ITEMS ARE NOT INDICATED ON THE DRAWINGS OR IN THE NOTES. ALL WORK CONSIDERED NECESSARY FOR THE COMPLETION OF THE WORK IN PROPER MANNER NOT SHOWN ON THE PLANS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING PRIOR TO BIDS OTHERWISE WORK SHALL NOT BE ADDITIONALLY CHARGED AFTER BID IS AWARDED. 6. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER, 7. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. 8. CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE, 9, UPON COMPLETION, CONTRACTOR SHALL CLEAN ALL DUST AND DEBRIS IN AREAS WHERE WORK WAS CONDUCTED. 10, ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF EQUIPMENT. 11. THE WORK THAT IS TO BE DONE UNDER THIS CONTRACT INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION OF THE SYSTEMS SHOWN ON DRAWINGS, 12. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW EVERY BEND, OFFSET, ELBOW OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED. 13. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND/OR SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF PIPING AND EQUIPMENT TO BE INSTALLED. 14, ALL MATERIALS AND EQUIPMENTS SHALL BE NEW AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 15. FOR EXACT LOCATION OF ALL PLUMBING FIXTURES, SEE ARCHITECTURAL DRAWINGS. DO NOT ROUGH -IN ANY PLUMBING FIXTURE AND/OR EQUIPMENT WITHOUT AN APPROVED COPY OF THE CORRESPONDING SHOP DRAWINGS. 16, PROVIDE A CLEANOUT AT BASE OF EACH SOIL AND WASTE STACK. 17. CLEANOUTS SMALLER THAN 3 INCHES SHALL BE SO INSTALLED THAT THERE IS A CLEARANCE OF NOT LESS THAN 12 INCHES FOR THE PURPOSE OF PODDING, CLEANOUTS ON 3 INCH OR LARGER PIPES SHALL BE SO LOCATED THAT THERE IS A CLEARANCE OF NOT LESS THAN 18 INCHES FOR THE PURPOSE OF PODDING, 18. PROVIDE 24"X24"X4" CONCRETE PAD FOR ALL CLEANOUTS LOCATED IN GRASS OR EARTH AREAS. 19. ALL FLOOR DRAINS AND SHOWER DRAINS WITH TAP FOR TRAP SEAL, 20. FLOOR DRAIN RESEALS SHALL BE FROM A WATER CLOSET FLUSH VALVE TAILPIECE UNLESS OTHERWISE NOTED. FLUSH VALVE WITH TRAP PRIMER ASSEMBLY. 21, ALL HORIZONTAL PIPING 3" AND LARGER SHALL BE SLOPED AT 1 /8" PER FOOT. ALL HORIZONTAL PIPING 2 1/2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT. 22. ACCESS PANELS LARGE ENOUGH TO REPLACE OR REPAIR UTILIZING NORMAL TOOLS SHALL BE PROVIDED FOR ANY VALVE LOCATED WITHIN A CHASE OR CONCEALED IN CEILING OR WALLS, 23, PROVIDE SHUT-OFF VALVES AND UNIONS TO ALL FIXTURES AND EQUIPMENT, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. 24. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES SUCH AS STOP VALVES, TRAPS, SUPPORTS, P E T VALVES, ETC, AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE WATER HAMMER ARRESTOR AT EACH GROUP OF FIXTURES. 25. PROVIDE SLEEVES FOR ALL PIPING THROUGH WALLS AND FLOOR SLABS. SLEEVES SHALL BE EXTENDED 2 INCHES BEYOND EACH FACE, SLEEVES FOR ANY PIPES SHALL BE OF THE SAME MATERIAL AS THE PIPING. ANNULAR SPACE BETWEEN PIPING AND SLEEVES SHALL BE FILLED WITH FIRE STOP PRODUCTS. SEE DETAIL. 26, PROVIDE PITCH PANS AND LEADS FLASHING FOR ALL SANITARY SYSTEM VENTS, PLUMBING DEMOLITION NOTES: I. SITE INVESTIGATION EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK, THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF WITH THE NATURE, EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, EXISTING FACILITIES AND ALL BUILDING STRUCTURES. HE IS TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS, LIGHT VARIATION OF ROUTING AND OR CONSTRUCTION SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. 2. THE NATURE OF THE REMODEL TYPE CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGNER ENGINEERS AS WELL AS THE PLUMBING CONTRACTOR, EVERY EFFORT HAS BEEN MADE BY THE ENGINEERS TO SHOW AND VERIFY, WHERE POSSIBLE, THE LOCATION OF THE EXISTING PLUMBING SYSTEMS. THE MAJOR PORTION OF THE PLUMBING SYSTEMS ARE AS SHOWN ON THE DRAWINGS HOWEVER MINOR DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. NO ADVANTAGE IS TO BE TAKEN BY THE PLUMBING CONTRACTOR BECAUSE THESE MINOR DIFFERENCES. THE CONTRACTOR SHALL VISIT THE PREMESIS AND COMPARE SAME WITH THE DRAWINGS AND SPECIFICATIONS AND SATISFY HIMSELF OF THE CONDITIONS EXISTING AT THE BUILDING BEFORE DELIVERY OF HIS PROPOSAL. NO ADDITIONAL ALLOWANCE WILL BE MADE TO THE CONTRACTOR DUE TO HIS NEGLECT OR FAILURE TO COMPLY WITH THE SPECIFIED REQUIREMENTS. 3. CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING HIS DEMOLITION WORK WITH OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING PIPES USED FOR FUTURE CONNECTIONS. 4. CONTRACTOR SHALL VERIFY SLOPE AND DEPTHS AND EXACT LOCATIONS OF CONNECTION POINTS TO EXISTING PRESSURE OR DRAINAGE LINES BEFORE COMMENCING WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. ANY DISCREPANCIES SHALL BE BROUGHT UP TO THE ENGINEER FOR REVEIW. 5. EXISTING PIPES SERVING AREAS REMAINING IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED UNLESS A TEMPORARY INTERRUPTION IS COORDINATED WITH THE OWNER. 6. ALL SERVICE INTERRUPTIONS SHALL BE SCHEDULED WITH THE AUTHORIZED REPRESENTATIVE OF THE OWNER. ALL REMOVAL AND DISPOSAL WORK SHALL BE COORDINATED WITH THE AUTHORIZED REPRESENTATIVE OF THE OWNER. 7. ALL EXISTING PIPING INCLUDED IN THE SCOPE OF WORK SHALL BE SNAKED OUT TO THE BASE OF THE STACK AND 5' BEYOND AND TESTED BY THE CONTRACTOR. 8, CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT PROPERTY IN AREAS WHERE WORK IS BEING CONDUCTED, THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES CAUSED TO BUILDING COMPONENTS DUE TO WORK OPERATIONS. PATCH AND REPAIR EXISTING SURFACES DAMAGED AS REQUIRED TO MATCH ADJACENT SURFACES, 9. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ALL EXISTING CONSTRUCTION, INCLUDING EXISTING TO REMAIN AND TO BE REMOVED. ITEMS AND DEBRIS TO BE REMOVED WILL BE PROPERLY DISPOSED OF BY THE CONTRACTOR, WITHIN HIS CONTRACT, AT NO COST TO THE OWNER. 10, ANY UTILITY LINES TO REMAIN AND THAT ARE BROKEN OR DAMAGED DURING DEMOLITION OPERATIONS SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL CHARGE TO THE CONTRACT PRICE, OR SHALL BE REPAIRED BY THE OWNER AT THE CONTRACTOR'S EXPENSE, 11. ANY DISCREPANCIES BETWEEN THE WORK DEPICTED ON THESE DOCUMENTS AND THE ACTUAL CONDITIONS ENCOUNTERED SHALL BE BROUGHT PROMPTLY TO THE ENGINEER FOR REVIEW AND CLARIFICATION. 12. LOCATIONS WHERE SAW CUTTING OPERATIONS OF THE FLOOR SLAB ARE REQUIRED SHALL BE PATCHED BACK TO MATCH EXISTING FLOOR CONSTRUCTION ONCE THE NEW UNDERGROUND PIPING INSTALLATION IS COMPLETE. 13, ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR RESTORED TO ORIGINAL CONDITION. 14. EXISTING PIPES SERVING AREAS REMAINING IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED UNLESS A TEMPORARY INTERRUPTION IS COORDINATED WITH THE AUTHORIZED REPRESENTATIVE OF THE OWNER. 15, REMOVE OR RELOCATE EXISTING PIPING IN CONFLICT WITH NEW CONSTRUCTION, INCLUDING DRAINAGE, WATER AND SATISFY CODE REQUIREMENTS FOR PROHIBITED DEAD ENDS. 16. CAP EXISTING HOT COLD WATER, WASTE, VENT AND SOIL PIPING AT POINT THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION, I.E. BELOW FINISHED FLOOR, BEHIND FINISHED WALLS OR ABOVE HUNG CEILINGS. 17. THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, CUT- TINGS, EXTENSIONS, CONNECTIONS, REPAIRING, ADAPTING AND OTHER WORK INCINDENTAL THERETO, TOGETHER WITH SUCH TEMPORARY CONNECTIONS AS MAY BE REQUIRED. 18. EXISTING FIXTURES, MATERIALS AND EQUIPMENT TO BE REMOVED SHALL BE SALVAGED OR DISPOSED OF AS DIRECTED BY THE OWNER. 19. ANY FORESEEABLE COST OF PIPING NOT INDICATED WHERE FIXTURES AND EQUIPMENT ARE SHOWN BUT CONSIDERED NECESSARY FOR THE COMPLETION OF WORK IN A PROPER MANNER SHOULD BE BROUGHT UP TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDDING AND SHALL BE PROVIDED BY THIS CONTRACTOR AT NO ADDITIONAL CHARGE. CONTRACTOR SHALT. INCLUDE THE COST OF MINOR OFFSETS AND DEVIATIONS NOT INDICATED ON PLANS. 20. CONTRACTOR SHALL DO HIS OWN CUTTING AND REMOVAL OF ALL HIS RELATED WORK IN ALL LOCATIONS WHERE REQUIRED, EXCEPT WHERE OTHERWISE SHOWN ON THE DRAWINGS AND/OR AS SPECIFIED. 21. CONTRACTOR TO REMOVE ALL EXISTING FIXTURE, TRIM AND REPLACE WITH NEW FIXTURES AND TRIM AS SPECIFIED CONNECT NEW FIXTURE TO EXISTING SOIL, WASTE VENT WATER PIPING. 22, REMOVE EXISTING FIXTURES AND TRIM, PIPING INCLUDING CARRIERS, AND CAP/PLUG PIPING AT CEILING, BELOW FLOOR, OR BEHIND FINISHED SURFACES. 23, CONTRACTOR TO REMOVE EQUIPMENT HEATER, HOT WATER, COLD WATER, DRAIN AND CAP PIPING AT CEILING BELOW FLOOR, OR BEHIND FINISHED SURFACE. PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE CW HW REMARKS L-I LAVATORY 1 1/4" 1/2" 1/2" CONTRACTOR TO REUSE EXISTING FIXTURES FROM (ADA ACCESSIBLE) DEMOLISHED RESTROOM. WC_I WATER CLOSET - FLOOR MOUNTED 4" 1" - CONTRACTOR TO REUSE EXISTING FIXTURES FROM (ADA ACCESSIBLE) DEMOLISHED RESTROOM, SK-1 THREE COMPARTMENT SINK 2" 1/2" 1/2" STAINLESS STEEL SCULLERY SINKS BY ELKAY x WNSF83452, TWO FAUCETS FOR SPLASHBACK MOUNTING WITH 12" SWING NOZZLE, 8" CENTERS, REMOVABLE SEATS, CHROME PLATED, LEVER HANDLES MODEL x 5-1128 BY TES BRASS, THREE QUICK OPENING DRAIN VALVES WITH OVERFLOW OPENINGS MODEL x LK 87PT BY ELKAY. ANGLE SUPPLIES WITH FLEXIBLE RISERS AND LOOSE KEY MODEL Y LK1005 BY ELKAY. CHROME PLATED P-TRAPS. PS-1 HAND SINK 1 1/2' 1/2" 1/2" STAINLESS STEEL SPLASH MOUNTED GOOSENECK FAUCET (HANDS FREE) ELECTRIC/EYE SENSOR OPERATED, LOW VOLTAGE ADAPTER WITH INTEGRAL MIXING VALVE. BASKET DRAIN, ANGLE SUPPLIES WITH FLEXIBLE RISER AND LOOSE KEY, LK-1005 BY ELKAY AND CHROME PLATED P-TRAP. MODEL x 7-PS-51 BY ADVANCETABCO. MR -I MOP RECEPTOR 3" 1/2" 1/2" MOLDED RESIN, 24" X 24" X 10" WITH CENTER DRAIN MODEL x MSB-2424 BY FIAT, FITTING EXPOSED YOKE, WALL MOUNTED, VACUUM BREAKER, TOP BRACE, STOPS IN SHANKS. MODEL x 830-AA BY FIAT. HOSE AND HOSE BRACKET: x832-AA MOP HANGER % 889-CC BY FIAT, VINYL BUMPER GUARD xE-77-AA BY FIAT. PLUMBING SPECIFICATIONS: HANGERS AND SUPPORTS A. PROVIDE ADJUSTABLE HANGERS, INSERTS, BRACKETS, ROLLS, TRAPEZE, CLAMPS AND SUPPLEMENTARY STEEL AS REQUIRED FOR PROPER SUPPORT OF PIPE LINES. B. HANGERS SHALL ALLOW FOR EXPANSION AND CONTRACTION OF PIPE LINES AND OF ADEQUATE SIZE TO PERMIT COVERING TO RUN CONTINUOUSLY THROUGH HANGERS, C. COORDINATE LOCATION OF HANGERS WITH OTHER TRADES. D. HANGERS SHALL BE PLACED WITHIN 18 INCHES OF HUB OR JOINT FOR HORIZONTAL CAST IRON PIPE. HUBLESS JOINTS MUST BE SUPPORTED AT EVERY OTHER JOINT EXCEPT THAT WHEN THE LENGTH BETWEEN SUPPORTS EXCEEDS FOUR FEET THEY SHALL BE PROVIDED AT EACH JOINT. E. HANGERS SHALL BE PLACED AT EACH CHANGE OF DIRECTION, WITHIN ONE FOOT OF VALVES AND OTHER APPURTENANCES INSTALLED IN HORIZONTAL PIPING AND NOT MORE THAN THREE FEET FROM END OF EACH BRANCH RUNOUT. F. HANGERS SHALL BE ADJUSTABLE CLEVIS TYPE WITH CONTINUOUS THREADED RODS. SANITARY GREASE WASTE AND VENT PIPING A. ALL HORIZONTAL BRANCHES, SEWER AND DRAIN LINES SHALL BE SLOPED A MINIMUM OF 1/8 INCH PER FOOT UNLESS OTHERWISE INDICATED ON PLANS. B. EVERY FIXTURE CONNECTED TO THE DRAINAGE SYSTEM SHALL BE EQUIPPED WITH A WATER SEAL TRAP. C. VENT STACKS SHALL NOT PASS THROUGH ROOF AT VALLEYS, ROOF CRICKETS, IN FRONT OF WINDOWS OR WITHIN 6-0" OF ROOF EDGE. D. MATERIALS SHALL BE AS FOLLOWS 1) DRAINAGE AND VENT PIPING (BELOW GRADE)t SHALL BE HUB AND SPIGOT SERVICE WEIGHT CAST IRON WITH GASKETED PUSH -ON JOINTS. 2) DRAINAGE AND VENT PIPING (ABOVE GRADE): SHALL BE HUBLESS SERVICE WEIGHT CAST IRON WITH NEOPRENE GASKETS AND STAINLESS STEEL BAND JOINTS. DOMESTIC COLD AND HOT WATER PIPING A. PROVIDE AIR CHAMBER 18" HIGH, NEXT SIZE LARGER THAN PIPE SERVING THE FIXTURE. B. PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED. C. ESCUTCHEONS SHALL BE CHROME PLATED BRASS WITH LOCKING SCREWS WHERE PIPES PASS THROUGH FINISHED WALLS. D. EACH HOSE BIBB SHALL BE FURNISHED WITH A VACUUM BREAKER AND SHUT-OFF VALVE, E. PROVIDE PIPING AS FOLLOWS: 1) WATER PIPING (BELOW GRADE): SHALL BE COPPER TYPE "K" ASTM B-88 WITH WROUGHT COPPER FITTINGS AND 95-5 SOLDERED JOINTS, PAINT WITH BITUMASTIC WHEN INSTALLED IN GRADE. 2) WATER PIPING (ABOVE GRADE): SHALL BE COPPER TYPE "L" ASTM B-88 WITH WROUGHT COPPER FITTINGS AND 95-5 SOLDERED JOINTS. COPPER TYPE "K" ASTM B-88 UNDER GROUND. 3) PRESSURE AND TEMPERATURE RELIEF LINES: SHALL BE TYPE "M" COPPER WITH WROUGHT COPPER FITTINGS AND 50-50 SOLDERED JOINTS. F. ALL EXPOSED PIPING WITHIN TOILET ROOMS SHALL BE CHROME PLATED. VALVES A. PROVIDE CONTROL VALVES WHERE NOTED ON PLANS, AND AS REQUIRED FOR COMPLETE REGULATION OR CONTROL OF ALL SYSTEM MAINS, BRANC14ES TO GROUP OF FIXTURES, AND TO EACH PIECE OF EQUIPMENT. B. PROVIDE ACCESS PANELS AS REQUIRED TO VALVES, OR GROUP OF VALVES, WHERE CONCEALED AND FOR PROPER MAINTENANCE AND OPERATION OF SYSTEM. C. GATE VALVES: 1) 2-1/2 INCHES AND SMALLER SHALL BE BRONZE BODY, SCREWED BONNET, NON -RISING STEM, SOLID WEDGE, CLASS 125, 200 PSI NON -SHOCK WATER, THREADED END WATTS WGV-SERIES, SOLDERED END WATTS WGVS-SERIES. TESTING A. COMPLETE WATER PIPING SYSTEM SHALL BE PRESSURE TESTED BY CAPPING OR PLUGGING OPENINGS, FILLING SYSTEM WITH WATER AND APPLYING HYDROSTATIC PRESSURE OF 125 PSI FOR PERIOD OF NOT LESS THAN 2 HOURS, B. SOIL, WASTE AND VENT PIPING SHALL BE TESTED BY CAPPING THE ENDS OF THE SYSTEM AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOW TO STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. KITCHEN EOUIPMENT SCHEDULE MARK DESCRIPTION WASTE CW HW REMARKS CONVECTION "OLIVER" OVEN 1/4" - PROVIDE DUAL CHECK VALVE BACKFLOW PREVENTER ® (STEAM INJECTION) (ASSE 1024) PROVIDE DUAL CHECK VALVE BACKFLOW PREVENTER © ELECTRIC CONVECTION OVEN - (2) 1/4" - (ASSE 1024) CW ROUGH AT 95" AFF ® PROOFER I/2" I/2° DRAIN PROVIDE I" AIR GAP PROVIDE DUAL CHECK VALVE BACKFLOW PREVENTER (ASSE 1024) IQ SOUP STATION 1/2" - - PROVIDE DUAL CHECK VALVE BACKFLOW PREVENTER 3 EXPRESSO COFFEE MACHINE - 1/4" (ASSE 1024) PROVIDE DUAL CHECK VALVE BACKFLOW PREVENTER O9 DUAL BREWER - 1/4" - (ASSE 1024) PROVIDE BACKFLOW PREVENTER WITH INTERMEDIATE II SODA MACHINE 3/4" 3/8" _ ATMOSPHERIC VENT (ASSE 1012) DRAIN PROVIDE 1-1/2" AIR GAP PROVIDE DUAL CHECK VALVE BACKFLOW PREVENTER 13 ICEMAKER 3/4" 3/8° (ASSE 1024) DRAIN; PROVIDE 1-1/2" AIR GAP *ALL EQUIPMENT SHALL BE PROVIDED WITH AQUA PURE FILTERS AS PER MANUFACTURERS RECOMMENDATION SYMBOL PLUMBING SYMBOL LEGEND u DESCRIPTION ------------------ CD PT CO I �--- WCO -c+ E FEi FEC -mm- El- ASV. AR AI2VTR ARWS AFF BLW. CEIL., CLG. CDS DN EXIST FA FB FL. FD GWS SS TRL. VB VIV VTR WS EXISTING LINE TO BE REMOVED -,'- VENT LINE COLD WATER LINE HOT WATER LINE HOT WATER RETURN LINE CONDENSATE DRAIN LINE PRESSURE AND TEMPERATURE RELIEF LINE GATE VALVE CHECK VALVE COUPLING OR UNION PRESSURE AND TEMPERATURE RELIEF VALVE CLEANOUT WALL CLEANOUT FLOOR CLEANOUT HOSE BIBB CAP POINT OF CONNECTION BETWEEN EXIST AND NEW FIRE EXTINGUISHER ON WALL BRACKET (2A-IOBC) FIRE EXTINGUISHER IN CABINET (2A-IOBC) WATER HAMMER ARRESTOR ABOVE ACID RESISTANT ACID RESISTANT VENT THRU ROOF ACID RESISTANT WASTE STACK ABOVE FINISHED FLOOR LEVEL BELOW CEILING A/C CONDENSATE DRAIN STACK DOWN EXISTING FROM ABOVE FROM BELOW FLOOR FLOOR DRAIN GREASE WASTE STACK SOIL STACK TRAP RESEAL LINE VACUUM BREAKER VALVE IN VERTICAL VENT THRU ROOF WASTE STACK PLUMBING DRAIN SCHEDULE MARK DESCRIPTION WASTE REMARKS FD-I POLISHED NICKEL 3" J.R. SMITH MODEL x 2005-B. POLISHED NICKEL BRONZE TOP, BRONZE TOP FLOOR WITH TRAP PRIMER. DRAIN FS-1 SANITARY FLOOR SINK 3" ACID RESISTANT INTERIOR FLOOR DRAIN WITH DOUBLE DRAINAGE FLANGE, WEEPHOLES, BOTTOM OUTLET INSIDE CAULK CONNECTION, SQUARE TOP, MEDIUM DUTY GRATE, STAINLESS STEEL MESHBUCKET LINER, LESS INTERNAL DOME STRAINER, 1/2 GRATE AND SEDIMENT BUCKET. MODEL x 49324A-31-35-45-3-X BY JOSAM. WATER HEATER SCHEDULE NO. CAPACITY HEATING SOURCE WATERKW VOLTAGE MANUFACTURER MODEL NO. COLD I HOT EVVH-1 50 GAL ELEC 1 1/2" 1 1/2" 18 480/3/60 LOCHINVAR HSX 18-082 Revisions: Z� I NO M d g o 0 o .. J [ <Z uI CEO W Om QQ O COW �- w Ld r U) I � M nto (D o cn U) m N o "� M M v U (� O Q L 1 E M N ° o 41<a c� .-w EI CA c� O M �� "Lj - Ln � h c5 g (J-) IW W � U z IW En U w - z m cn 7�; O 1-- 1 m 0 n I� W W 0 DRAWN: JB CHECKED: E6 DATE: 02-18-®a SCALE: AS NOTED SEAL l; "'�ri ME4 ANICA' .: E ")NESTO SANTANA RE, LICENSE u 60788 Sheet No. Pd.O0 JOB # 21033