08-985(2)-011I ►9 m NOTE: THE DETAIL5 ON THIS SHEET ARE CONSiDERED TYPICAL AND ARE NOT NECESSARILY CALLED OUT ON FLANS RIMER TRACK AT FILL VOIC'' ::: ;:_ "• VERTICAL JOINTS AND FIPON JE CCn �D i'—SPRAY S CT ON - VERTICAL J AT AM 2 OC : � ' STEEL BEAM c7F/Fs 70R L FASTEN 22'' O1TC� STEEL JOIST 1 FILL VpIDG WI7N r AND FIF ODE 'NC 1; STEEL CLIP 'L' I """-- STAND-OFF • r ► I t , • , N CEILING r� r SPRAYED FIREPROOFING I. rIREPhi00FlNG - "-H METAL STu>~. q 24' OC. (TYPJ N , i': r'. SECTION `1 I . r RUNNER TRACK AT VERTICAL JOINTS f=' 4NT 20 CsA LIP 2' �— Fk t DC. FASTEN BEFORlT FASTEN GYP BD. FULL HT.FIR FASTEN k" PER FIRE TEST ,•.:: �� •' �•' RIMER FASTEN TO CLIPS ONE OR TWO HOUR E' ABUT TIGHTLY TO FFFG T = 4- F PARTITION STEEL JOIST CANNOT BE r A PART OF THE RATED SEPARATION. ---1 OR 2 LAYER GYR SD. :. OU T SHAFT WA : EACH SIDE •• AS REQ' D. SAFE AS REQUIRED FIREPROOFING MUST HAVE 2-HOUR THICKNESS OR GREATER f :1 TO SKETCH N 109, LtaCx, HAN01300K EG. t0 SKETCH 110, USCrt, HAND1.300k j SMOKE AND RATED PARTITION ADJACENT TO BEAM NTs•(2)SHAFT WALLS DETAIL NTS. 3 RATED PARTION UNDER BEAM MT� FIRE PROOFI SPRAY ON ROOF/FLOOR DECK do * ITT TITr ► •�,:, ;� •� ri1 ,sly' 1 i rit - �' f •--r� � � dd GYP. OD. ON .� METAL fTUD° { FILL VOIDS WITH SAFNG AND FIRE CODE COMPOUND I . ' STEEL STUDS 1 - STF ` r:AM ABUT TIGHTLY TO i G s 20 CAA. Z-CLIP"v 2' O.C. 20 G. P v . MAX G' GYP. BD. FASTEN BEFORE SPRAY 2 O.C." t CANTILEVER 1. :1FASTEN NOTE: BOARD MUST Fi11�11=R FASTEN TO CLIPS SPAN MN. 2 "STUDS ( I I I BEFORE CANTILEVF s y 1 ABUT TIGHTLY f_ t j N i } 'iWER FASTEN TO r NG �O CLIPS 1 ENTIRE r I OR 2 LAYERS SAFING a GYP. BD. EACH SIDE - AS REQ'D. SAFE AS REQVD TRAl US12EIg pgAM RATED PARTITION UNDER JOIST �UIV. TO SKETCH 109, USG, HAND50M EQUiv: t0 SKETCH • 114, USG, HANDBOOK U DERABEAM ANI�P/OR UNDERTAST GREATER THAN 2' LESS THAN (V FLOOR OR ROOF SLAB ASSEMBLY CUT GYPSUM PANELS TO FIT DECK CONFIG. 1/4' NOM. GAP FILL WITH ACOUST. SEALANT FANNERS - ATTACH WITH ANCHORS T-0' OG. CEILING CONTINUOUS STEEL STUDS (I6' / 24' O.C-) ACOUSTICAL SEALANT RIMERS - ATTACH WITH ANCHORS 2'-0' Or: FIN. FLOOR SECTION - N.T.S. TEST REF: T-3342-0SU T-1114-05U GA-WP-1200 11 SMOKE ,4 ONE -HOUR PARTITION DETAIL ( x3A AR TO BEAU OR FLOOR DECK CEILING HAZARDOUS ROOM FUNCTIONS WHICH DO NOT OTHERWISE REQUIRE A RATED ENCLOSURE ARE "STILL REQUIRED TO BE SEPARATED BY A SMOKE RESISTANT PARTITION C0146TMCTWTO THE DECK ABOVE. SMOKE RESISTANT WALLS MUST BE CONTINUOUS FROM FLOOR TO DECK ABOVE UNLESS THE CEILINGIS A FIRE RESISTANCE RATED FLOOR/CEILING OR ROOF/CEiLNGASSEMBLY. "j RATED WALL PERPENDICULAR TO BEAM N.T.S. FLOOR OR ROOF SLAB ASSEMBLY MAX. 2' FILL VOIDS. SEE DETAIL "G TIGHTLY FILL VOIDS AT METAL DECK WITH SAFING MATERIAL - 4 O/CF DEN RMEW2 - ATTACH WITH ANCHORS 2'-0' O1C. CEILING rnTTnnTTnnTinTrnTtrrrm CONTINUOUS STEEL STUD5 (14' / 24' OLJ SAFING AS REQUIRED --- ACOUSTICAL SEALANT F"ERS - ATTACH WITH ANCHORS V-0' O.C. FIN. FLOOR SEGT-IUN- RT'.S. MST REF,. T-3362-05U T-1114-OSU GA-WP-1200 N.T. 12 SMOKE 4 ONE -HOUR PARTITION DETAIL (FEFW`Ilavlc"Ie TO OEM STiRUCTURE ABOVE --� SCHEDULE CEILING& 5/5' GYPSUM BOARD OVER 3 5/6' METAL STUDS F.E./F. HOSE CABINET/ ELECTRICAL/ TELEPWONE PANELS 5/N5" TYPE 'X' GYPSUM WALLBOARD AT RATED PARTITIONS NOTE —REFER TO 1/5' FLOOR PLAN FOR (rXACT LOCATIONS N.TF. E. CABINET SMOKE RESISTANT WALLS AND HAZARDOUS N.T.S. FIRE EXTINGUISHER CABINET/ELECTRICAL/ 1� FUNCTION SEPARATION WALLS (As DEFINED N STANDARD eulLow. CME 40ww I TELEPHONE/PANELS SECTION NOTE: ALL RATED PENETRATION DETAILS ON THIS 5HT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPANY DETAILS FOR HOSPITAL AND INSTITUTIONAL CONSTRUCTION. _ HANDBOOK DATED FEBRUARY 1551, REV15ED AUGUST I551. EQUIVALENT DETAIL NUM5iiR5 ARE SHOWN WHERE APPLICABLE - FILL VOIDS WITH SAFk" W FILL VOIDS WITH JCs AND FIRE CODE CON �' #? - AND FIRE GODh 'OWD RIMER FASTS► RUNNER " TN 2' O:t.: ROOF (FLOG .s y NC .�• .err., t' t .. _ ,u � ' • ' l .1 l• 1 t r � � ,r.�� ' p �' : I • l ED FIREPROOFING E X Il. I SPRAYED FIREPROOFING EXTEND ALL LAYERS OF GYF? BD. To DECK AND SEAL AT FACE LAYER WITH ACOUSTICAL SEALANT. )TYPICAL HEAD OF PARTITION N.T.5. g TYPICAL HEAD OF PARTITION CONC. SLAB ON METAL DECK -} GYPSUM WALLBOARD 13LOCK (1/1' X i') . SPACED la' O.C. VERT. AT EACH CHANNEL r cy —lf7 ''t WIRE TIE LATH, BLOCK TOGETHER J1 J• t AND CHANNEL K•. M a 3.4" D M LATH (GALV3 FIN. FLOOR OR ROOF GYPSUM PLASTER tS FULLY ED PACK WITH III NOTE: BOX IN WITH GYP. 60. AND METAL STUDS WHEN STEEL J015T CONDITION CONT. ANGLE RETANER SCREW TO STUDS - ONE OR TWO HOUR _ _ ►Ti PARTITION EQUIv. .`.s10ETCH " i01, USIS, HAND600K SMOKE 4 RATED PARTITTION ADJACENT TO BEAM NTH N.TS. (STRUCTURALLY BOXED IN) DECK i HR. RATED MEMBRANE NEW 5/6' TYPE 'X' r, NEW STUD EXTENSION REMOVE EXIST. DRYWALL tr RATED CEILING j A NOTE: DRYWALL JOINTS ALL DRYWALL STAGGERED AT 5/8. TYPE X. OPPOSITE WALL SIDES BY MM 12' EXISTING WALL REMOVE EXIST. HEAD TRAGIC EXTEND EXISTi14G WALL 2 HRI WALI JHFRIJ 1 C "f TO DECK FOR i HR WALL (SHAFT WALL 51MILER) DECK SAFNNG CLIP N 1 FIR, RATED 2 PER STUD -- EXTRA WIDE WALL �� I SPACE MEMBRA14E— � �1 RATEDWALL FURRING PARTITION PENETRATION DETAIL OF NTs. �y-"j ONE HOOUR RATED MEMBRANE I FACE TO BE SEALED WITH I DRYWALL SEALANT, OR TAPE AND JOINT COMPOUND TIGHTLY FILL V0105 AT METAL ' DECK WITH 6AFING INSULATION I I - 1/2" CRC iG' O.C. T RATED CCNC. BLOCK SEE PLAN FOR SIZE AND iRATiNG �' :. �; SHAFT SIDE �•;ii NOTE: THE BLOCK MANUFACTURER FINISH SIDE SHALL SUBMIT DESIGN CALCULATION "STATING THE APPROVED EQUIVALENT t THICKNESS AS REQUIRED BY THE SECURE 1 - 1/2' GRC TO ANGLE FIN FLOOR STANDARD BUILDING CODE. � .. i-1/2' X 1-1/2, X ld GA, CONT. ANGLE FLOOR AND STRUCTURE ABOVE. FLOOR � -�.:1. FASTIEt•1 AT 24" Ot. I WALL SECTION WALL SECTIOII (MAX" HEIGHT Is'-0') N.T.6. — N TS. TYPICAL TWO HOUR PLASTER SHAM= TWALL DETAIL NTS N.T.S. 13 TYPICAL RATED BLOCK WALL FiRE OR SMOKE N.T.S. (14) fllm"j•rw*t( w_,v) PIl AA EL rY PIPINGS ANp/OR CONDUIT : u 'ING �r - DUCT ECTRICA CL la• 1a' la' CLEA CLEA CLEAIQ A/C DUCT RECESSED LIGH FI RE CEILING ROOM CORRIDOR ROOM N.T.S. [j,5) EQUIPMENT CLEARANCE DETAIL N.T.S. K 1 e N.T.S. M HOUR WALE ONE HOR WALL NOTES: 1. JOINTS MAY BE OPPOSITE IF SAFEiNCs IS USED N CAVITY. REF: CEG 6.11.03 CEG 5-5-54 2, JOINTS N FN15H LAYER TO RECEIVE TAPE AND JOINT COMPOUND HORIZONTAL JOINT REQUIREMENTS ABOVE SUSPENDED CEILINGS C %gN Gv elso N.T. N.T.S. N.T.S. Revisions: 0 0 0 ZL z H r..t "Q 0� Z AIM„ N t':14 woo w � z z A 0 i LI 44 DStAWP& VC cHiCKM LEN DA7'F.s; 02-i5-06 SC'AlLle N.T.5. SEAM.:' Sheet No. A-9 OF 9 Jos 0 2i033