08-985(2)-008l FINISH SCHEDULE
ROOM
WAINSCOT
CEILING
FLR.
NO-
ROOMNAME NAME
FLOOR
BASE
WALLS
REMARKS
MAT,
HGT.
MAT.
NC�T.
100
NEW SALES AREA
CT
COVE
PAINT ON EXIST'G G.W.B.
-
-
*ACT
*V-0'
* EXISTING
101
NEW SACKROOM
Q.T.
COVE
FRP PNL. ON DUROCK
-
-
*ACT
V-0'
f EXISTING
p
101A
NEW JANITOR RM
-
-
F.R.P. ON EXIST'G GUJB.
-
*ACT
I'-h"
* EXISTING
O
lu
102
NEW WOMEN'S RM
CT
CT
PAINT ON EXIST'G G10B.
CT,
5'-0"
*ACT
I'-&'
TO MATCH EXISTING
103
VESTIBULE
CT
COVE
PAINT ON GUHE�.
-
-
*ACT
#V-0'
# EXISTING
'E
104
EXIST'Cx MEN'S R1'1.
*CT
•GT
*PAINT ON EXIST'G G.WJ5
C.T_
5'-0'
1 -ro
EXISTING TO REMAIN
105
NEW PREPARATION RM
•Q.T.
COVE
PAINT ON EXIST'G G U 5.
-
-
*ACT
#13'-0'
* EXISTING
FIN13H 3CHEDULE NOTE3
1.
ALL INTERIOR FINISHES SHALL MEET THE FOLLOWING REQUIREMENTS: ALL INTERIOR FINISHES SHALL BE GLASS 'A' WITH FLAME
SPREAD 0-25 AND SMOKE DEVELOPED 0-450. 0.45 WATTS PER SQ. CM. ALL FLOOR FINISH IN CORRIDORS AND EXITS SHALL BE
CLASS 'I' MINIMUM DEVELOPED 0-450 MAY BE USED IN EXCEPTIONS: CLASS 'B" INTERIOR FINISH WITH FLAME SPREAD 26-15 AND
SMOKE SMALL INDIVIDUAL ROOMS OF NOT OVER 4 PERSONS CAPACITY, OTHER THAN EXITS AND ACCESS TO CORRIDOR EXITS.
2.
ALL WALLS 4 CEILING FINISHES TO BE CLASS "A' FINISH (0-25) FLAME.
3.
INTERIOR FINISH IN CORRIDORS SHALL BE CLASS 'I'.
4.
NOT USED.
D.
PROVIDE WATER-RESISTANT GYPSUM WALLBOARD IN ALL WET AREAS AND FINISH WITH ENAMEL PAINT.
G .
CONTRACTOR TO REPAIR, PATCH, AND REPAINT ALL DAMAGED FINISHES AS REQUESTED IN ALL EXISTING REFINISHED
AND REMODELED AREAS.
-1.
ALL CORRIDOR WALL SURFACES ADJACENT TO PROJECT AREA ARE TO PAINTED OR CLEANED TO MATCH EXISTING.
S.
ALL EXISTING DOOR FRAMES IN AREAS WHERE NEW WORK IS TO BE DONE, ARE TO RECEIVE NEW PAINT/ STAIN AS
SELECTED BY OWNER.
S.
EXISTING AREAS TO BE RETAINED. PATCH AND REPAIR / REPLACE AS REQUIRED TO MATCH EXISTING ADJACENT FINISH.
10.
BASE TO MEET "AU BON PAIN DESIGN STANDARDS%
11.
CERAMIC FLOOR TILE TO MEET OR EXCEED 'AU BON PAIN DESIGN STANDARDS".
12.
EXISTING SUSPENDED ACOUSTICAL CEILING TILE TO REMAIN, UNLESS OTHERWISE NOTED.
13,
CONTRACTOR TO PROVIDE SHOP DRAWINGS TO A/E FOR REVIEW AND APPROVAL.
14.
ALL ACCESSORIES ARE TO MEET "AU BON PAIN DESIGN STANDARDS'.
15_
PAINT ON GYPSUM WALLBOARD SHALL BE: BENJAMIN MOORE SATIN FINISH, COLOR SELECTION BY AU BON PAIN.
IEo,
PAINT ON DOORS 4 FRAMES SHALL BE: BENJAMIN MOORE SEMI -GLOSS FINISH, COLOR SELECTION BY AU BON PAIN,
11,
F.R.P. PANELS IN BACKROOM, COLOR SELECTION AND TYPE BY OWNER.
f=AfRT I T I ON TYPE
WALL. TYFE GENERAL NOTE6:
1. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE APPROPRIATE CONSTRUCTION OF ALL WALL TYPES AND COORDINATION
OF ALL MECHANICAL, ELECTRICAL, PLUMBING AND EXISTING CONDITIONS ADJACENT TO SUCH WALLS. SINGE THE WORK INVOLVES EXISTING
BUILDING SYSTEMS AND FACILITIES, THE CONTRACTOR SHALL GIVE SPECIAL CONSIDERATION TO EXAMINATION OF ANY EXISTING CONDITIONS
THAT WILL PREVENT THE CONSTRUCTION OF SUCH RATED WALLS AS PER PLANS. VARIATION OF TYPICAL RATED WALL TYPES DETAILS
SHALL BE ANTICIPATED AND SHALL BE EXPRESSLY INCLUDED AS PART OF THE WOR< WHENEVER REQUIRED, AT NO ADDITIONAL COST TO
THE OWNER. A/E WILL SUPPLY THE DIFFERENT DETAILS FOR SUCH WALLS IF NEEDED, IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN
NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT.
2. ALL PARTITIONS SHALL BE 4' NOMINAL DIMENSION UNLESS OTHERWISE NOTED ON PLANS.
3. INTERIOR WALLS, PERMANENT PARTITIONS (RATED OR NOT) AND TEMPORARY PARTITIONS SHOULD SUPPORT A MINIMUM OF (5) POUNDS PER
SQUARE FOOT APPLIED PERPENDICULAR TO THE WALL.
4, PROVIDE BACKING SUPPORT AT ALL PARTITIONS WHERE EQUIPMENT IS INDICATED TO BE MOUNTED.
5. INSTALL METAL STUDS AT lro' O.C. WITH GYPSUM WALLBOARD HUNG VERTICALLY. '
6, GENERAL CONTRACTOR TO VERIFY ANY EXISTING PARTITIONS WITH NEW WALL TYPE DESIGNATIONS AND UP -GRADE AS REQUIRED TO
REFLECT NOTED WALL TYPES.
�• SUPPORT OF SOFFITS FROM RATED PARTITION IS APPROVED, ONLY IF THEY ARE ATTACHED DIRECTLY TO METAL STUDS AND/OR
STRUCTURAL BACKING ONLY, ATTACHMENT TO GYP. WALLBOARD IS NOT ALLOWED.
S. ALL EXISTING/NEW EXTERIOR MASONRY WALLS TO HAVE SCHEDULE SCHEDULE FINISH ON 5/S' TYPE 'X' GYPSUM WALLBOARD ON 1-5/0"
METAL STUDS AT 16" O.G. OVER RIGID INSULATION BOARD (TYPICAL AT ROOM SIDE OF ALL FINISHED ROOMS ONLY),
9. ALL EXTERIOR MASONRY WALLS TO HAVE ONLY RIND INSULATION AT ALL UNFINISHED ROOM SIDES.
10. PROVIDE CONTINUOUS (UNINTERRUPTED BY FURRING) R-4.5 (MIN.) RIGID INSULATION BOARD AT ALL EXTERIOR BLOCK/CONCRETE WALLS
FACING AIR CONDITIONED SPACES. INSTALL FROM FINISH SLAB TO UNDERSIDE OF STRUCTURAL DECK, GYPSUM WALLBOARD TO CONGEAL
INSULATION TO UNDERSIDE OF FINISHED STRUCTURAL DECK.
11- ALL DIMENSIONS SHOWN ON FLOOR PLANS ARE EITHER ROUGH (STUD TO STUD) OR MASONRY (MASONRY (MASONRY TO MASONRY OR
MASONRY TO STUD) TYPICAL U.O.N.
12• IT IS REQUIRED THAT AFTER THE METAL STUD FRAMING IS COMPLETED ON A RATED PARTITION THAT THE COMPANY PROVIDING THE SYSTEM
INSPECTS AND CERTIFIES IN WRITING THAT THE FRAMING HAS BEEN PERFORMED IN COMPLIANCE WITH THEIR REQUIREMENTS AND U.L. LABEL.
SAME CERTIFICATION SHALL BE PROVIDED FOR GYPSUM WALLBOARD INSTALLATION, SCREWING AND TAPING. CONTRACTOR IS RESPONSIBLE
FOR PLACING ELECTRICAL, AND OTHER OUTLETS AND BOXES IN SUCH A FASHION AS TO NOT VIOLATE INTEGRITY OR STC RATING OF
PARTITION.
13. ALL EXISTING MASONRY WALLS OR CONCRETE COLUMNS IN AREAS AFFECTED BY NEW RENOVATIONS SHALL RECEIVE SCHEDULED FINISH ON
5/0' TYPE "X" GYPSUM WALLBOARD ON I/S' METAL FURRING STRIPS AT I&' O.C. (TYPICAL UNLESS OTHERWISE NOTED ON PLANS).
14• BLOCK UP ALL PENETRATIONS THROUGH EXISTING EXTERIOR WALLS DUE TO THE REMOVAL OF EXISTING EQUIPMENT WITH RINKER TYPE T-18
OR T-IIA, RE -STUCCO EXTERIOR FACE AND PAINT TO MATCH EXISTING ADJACENT. (SEE MECHANICAL DRAWINGS)
2'x2' CEILING
SMOKE DETECTOR OR GRID
SPRINKLER HEAD
ACOUSTICAL
TILE
DETAIL
BOTTOM OF EXIST'G
STRUCTURAL DECK
CEILING BACK-UP
STUD
CEILING DETAILS
3-5/8' MTL.
STUDS 10 IFo'
O.G.
ACOUSTICAL
CEILING TILE
5/8' G.W.B.—
DOOR FRAME
EXISTING CONC.
SLAB
ACOUSTICAL
CEILING
NOTE: DO NOT SUPPORT SOFFIT FROM FIRE RATED PARTITIONS.
AT FIRE PARTITIONS ANCHOR TO STRUCTURE ABOVE.
CEILING DETAIL
BOTTOM OF FIN,
STRUCTURAL GONG. DECK
EXIST'G SUSPENDED
ACOUSTICAL CEILING
GRIP ----N,
EXIST'G SUSPENDED
ACOUSTICAL CEILING
INSTALL NEW WASHABLE
GRID
TYPE CEILING TILES
NEW METAL
NEW F.R.P. PANEL ON ONE
TRACK (TYP_)
SCHEDULE FINISH ON 5/5'
PROVIDE METAL
LAYER 5/a'CEMENTITIOUS
/
TYPE 'X' WALLBOARD
STUDS AT
WALLBOARD
ON METAL STUDS '� 1(0`
WALLBOARD
ON GEN ER
HORIZONTAL
�' METAL STUDS At 1�0"
(�
JOINTS
A.PROVIDE
O.C.
,�. /
w
>
METAL STUDS
/
Q
AT UTALLE3OARD
/
w
ACTUAL DIM. 4 '1/8' FOR
HORIZONTAL JOINTS
3 5/8' STUD
SOUND
ROOM SIDE
ACTUAL DIM. 1 1/4'
ATTENUATION
BLANKET TO
VISQUEEN VAPOR
FOR 9>' STUD
UNDERSIDE OF
BARRIER
EXISTING
ACTUAL DIM. 9 1/4"
CEILING TILE
THERMAL BATT INSULATION
/
GONG_ BLOCK
FOR FOR 8' STUD ------.-
BETWEEN STUDS
/
WALL
SEALANT (BOTH
SEALANT
FINISH SLAB
(EXISTING)
SIDES)
FINISH CONCRETE
/
SLAB
PARTITION TYPES NOTES:
;
5ECT 10N
I_•- ALL STUD PARTITIONS TO BEAR
'�
\_20
CABINETS SHALL HAVE A MIN. 20 Csa,
3/18' TAPGONS ifa' O.C.
CI MIN. EMBEDMENT)
GAGE STEEL
TYPICAL
TRACK (TOP #
PROVIDE %' CEMENTITIOUS
lA WALLBOARD
6ECT ION
BOTTOM
AT WET
LOCALITATIONS
TYPICAL)
ILIme
CEILING DETAIL
MfwTAL STUDS`
'�C V !w'f1Vl lam:
A
A
A
....
pop„
�
va"
�A
Q
*�
96
mu
0
ow
N
vgS
164
O
DRAW% OLP
C ECKED: LEN
DATE: 02 -18-08
SCALE: NTS.._
NOT TO SCALE
NOT TO SCALE