08-985(2)-0075/8' CEMENTITIOUS u TYPE 'X'
WALLBOARD WITH GYPSUM
SCHEDULED FINISH
F.R.P. PANELS WALLBOARD
ON 5/0" DRYWALL
2 METAL STUDS
3 5/5" GALV.
CAULK (TYP. EACH
CONT. GALV. STEEL STUDS
16" 0�0-
FLOOR FINISH MARBLE SILL CERAMIC
SIDE)
RUNNER
SEE FINISH ON THIN SET TILE ON THIN
HOLLOW METAL FRAME
CONT. P.T. 1 X 4
SCHEDULE SET
3 CLIPS PER JAMB
ZINC CORNER 4 -
VARIES
Q
SQUARE EDGE
►�
CASING: LEADS
GALV. HEAVY
1
ct) N
DUTY STEEL
SEALANT
1/2' ---1
2 2
TRACK 4 BALL
Z
WOOD BI-FOLD BEARING TRACK
DOORS PER ASSEMBLY
_j
SCHEDULE
a-
FINISH FLOOR
(SEE SCHEDULE)
NOTE:
THRESHOLD SHALL NOT HAVE
ANY CHANGE IN ELEVATION
C 2" 51,5.1
GREATER THAN 1.2 SLOPE.
J-1 H-1 JAME3 DETAIL./MEAD 51MIL.AR N.T.S.
H-2 B I -FOL.D DOOR HEAD DETAIL. N.T.S.
T-1 THRE5H OLD DETAIL. N.T.S.
151A BY PEMKO
NEW FLOORING
3'
1/4'
EXISTING CONCRETE
SLAB
No. 10 x 1-1/2" FHWS,
PHILLIPS (FACTORY
PROVIDED)
• COLOR SELECTION AND 151A HALF SADDLE, 1/4' X
FINISH BY OWNER 3% FLUTED
-2 THRESHOLD DETAIL_ N.T.S.
r-
U
kn
w
AL
to H
Q
W
z
FRAME HEAD RABBET
HINGE
� DEADLOCK STRIKE ---
(t HOSPITAL ARM
PULL (LOWER BASE)
AND PUSH PLATE
4. PUSH BAR AND PULL
(t STRIKE FOR KNOB
LOCKS, HANDLE
SETS. ROLLER
LATCHES 4 EXIT
DEVICES
HINGE
SCHEDULED FLOOR BOTTOM
OF
FRAME
TYPICAL. DOOR DETAIL.
N.T.S.
t
0
r
DCIOF� C
00 M
DOOR
p00R
DOOR
DOOM? SIZE
FRAME
DETAILS
HDW
SE=T
LABEL
AUTO.
DOOR,
REMAR<5
NO.
NO.
TYPE
MAT.
UJ�'H.
HGT.
TH.
MAT.
JAMS
HEAD
`>~RESN.
ND.
ASSEM.
(A.D.)
100
100
A
ALJGL.
3'-0'
-1'-0'
1 3/4"
ALUM.
f
_
-
-
# EXISTING W/ DOOR CLOSER V
101
101
B
WOOD
3'-0"
-1'-0'
13/4111
METAL
J-1
W-1
T-2
-
-
-
101A
101A
C
WOOD
2'-0'
11-0'
1 3/4
-
*
H-2
-
-
-
-
102
102
B
WOOD
3'-01
-I'-0'
1/4
HM
J-)
H-1
T-1
-
-
_
LOCATED EXISTING DOOR WITH
00 CLOSER_
103
NOT
USE
104
104=
8#
WOOD{
3'-0'
1'-0'
13/4
HM
-
• EXISTING W/ DOOR CLOSER
100
105
15
METAL
3'-0'
-7'-0'
1 3/4'
HM
-
-
B
EXISTING W/ DOOR CLOSER
105
G-1 4 2
-
PLYWD.
2'-81
2'-56
1'
-
-
-
-
-
-
WITH AUTOMATIC CLOSER
F_...)00fR NOTE5
1.
ALL DOORS AS SHOWN ON FLOOR PLANS ARE EXISTING TO REMAIN.
2.
CONTRACTOR SHALL NOTIFY ARCHITECT IF ANY EXISTING DOORS (FIRE RATED OR OTHEWISE)
ARE FOUND DEFECTIVE OR NOT MEETING STANDARDS SET IN THIS CONSTRUCTION DOCUMENT SET.
3.
ALL EXISTING DOORS HAVE ACCESSIBLE HARDWARE.
4.
DOOR NUMBERS CORRESPOND WITH ROOM NUMBERS FOR EASE OF IDENTIFICATION. SEE
FLOOR PLANS FOR LOCATIONS.
5.
DOORS, JAMBS, AND TRIM TO BE PAINTED WITH DTM BONDING PRIMER
AND DTM ACRYLIC COATING PAINT. SEMI -GLOSS FINISH. (COLORS BY AU BON PAIN).
(.
ALL HARDWARE AND FRAMES SHALL MAINTAIN THE INTEGRITY OF THE FIRE RATING OF THE
DOORS.
7•
PROVIDE SMOKE TIGHT CAULKING AROUND ENTIRE PERIMETER OF FRAMES.
S.
USE DOUBLE (ATTACHED) 20 GAUGE METAL STUDS AT JAMB OF ALL DOOR OPENINGS IN
METAL STUD PARTITIONS.
S.
CONTRACTOR SHALL FIELD VERIFY THICKNESS OF ALL EXISTING PARTITIONS
ACCOMMODATING NEW DOORS IN ORDER TO DETERMINE THE "THROAT" DIMENSIONS OF
NEW FRAMES.
10,
SEE FLOOR PLAN FOR EXACT DOOR SWING.
11.
NO KNOCK -DOWN FRAMES SHALL BE PERMITTED THROUGHOUT.
12.
FOR DOOR JAMB, HEAD AND SILL DETAILS, SEE SHEET A-5
13.
ALL WOOD DOORS TO BE SOLID CORE UNLESS OTHERWISE NOTED. SEE SPECIFICATIONS.
14.
ALL DOORS SHALL BE PROVIDED WITH A 5/0" UNDERCUT. MAXIMUM CLEARANCE BETWEEN CITY 1 �OU'TH MIARV
suII.I 1I�t f)r-p7,
THE BOTTOM OF THE DOOR AND THE CONCRETE SLAB SHALL BE 3/4" MAX. EXCEPT AT
THRESHOLD CONDITIONS.,t.:;
�Trvuc
15.
CONTRACTOR SHALL VERIFY SIZE OF ALL DOOR OPENINGS AND CONTACT THE ARCHITECT1`,cc
IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING DOORS AND/OR FRAMES.`✓"`r°.
1�.
ALL "B" LABELED STAIR DOORS TO BE 450' TEMP. RISE IN 30 MINUTES.
1-1.
USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED).KNURLED
LEVER HANDLES SHALL BE PROVIDED AT ALL TELEPHONE CLOSETS, MECHANICAL AND
ELECTRICAL ROOMS.
I&
DOOR HANDLES SHALL BE MOUNTED Q 4S" A.F.F. (MAXIMUM).
+ V.
Is.
DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10 DEGREES,
hQA4,, �- ADF_ COURY rjRkr pn
THE DOOR WILL TAKE AT LEAST 3 SECONDS TO CLOSE TO A POINT 3 INCHES FROM THE
y
LATCH."
�_,_..., t�IM•lcr�
k17
° �
20,
THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS :
a) REQUIRED FORCE FOR EXTERIOR HINGED DOORS'IS = S.5 Ibf
b) REQUIRED FORCE FO INTERIOR HINGED DOORS IS = 5 Ibf
c) REQUIRED FORCE FOR SLIDING OR FOLDING DOOR IS = 5 Ibf
21,
ALL DOORS IN THE MEANS OF EGRESS SHALL BE SINGLE ACTION RELEASE, SHALL COMPLY
WITH F.A.C.AND
SHALL NOT REQUIRE THE USE OF A KEY , TOOL OR SPECIAL KNOWLEDGE TO OPEN FROM
THE EGRESS 51DE.
0
EXISTING
IMPACT
RESISTANT
DOOR AND
GLAZING
moor 74rFE5
O
FLUSH
to " x 12 " S/S
PUSH PLATE
12" k S/S
KICK. PLATE
BI -FOLD/
HALF LOUVER
PLASTIC
LAMINATE
rt� It^ I I
FLOOR u
LINE — — —
Cs-1 Cs-2
Revisions:
1�1
0
z (Oi
Z
0
0
A
DRAWN: OLP
CHECKED: LEN
DATE: 02 -18-08
SCAM: NTS-
SEAL .'S
,..� OF r 4;
�I±U
A
Sheet NO.
A-5
OF
9
JOB # 21033