Loading...
08-985(2)-0075/8' CEMENTITIOUS u TYPE 'X' WALLBOARD WITH GYPSUM SCHEDULED FINISH F.R.P. PANELS WALLBOARD ON 5/0" DRYWALL 2 METAL STUDS 3 5/5" GALV. CAULK (TYP. EACH CONT. GALV. STEEL STUDS 16" 0�0- FLOOR FINISH MARBLE SILL CERAMIC SIDE) RUNNER SEE FINISH ON THIN SET TILE ON THIN HOLLOW METAL FRAME CONT. P.T. 1 X 4 SCHEDULE SET 3 CLIPS PER JAMB ZINC CORNER 4 - VARIES Q SQUARE EDGE ►� CASING: LEADS GALV. HEAVY 1 ct) N DUTY STEEL SEALANT 1/2' ---1 2 2 TRACK 4 BALL Z WOOD BI-FOLD BEARING TRACK DOORS PER ASSEMBLY _j SCHEDULE a- FINISH FLOOR (SEE SCHEDULE) NOTE: THRESHOLD SHALL NOT HAVE ANY CHANGE IN ELEVATION C 2" 51,5.1 GREATER THAN 1.2 SLOPE. J-1 H-1 JAME3 DETAIL./MEAD 51MIL.AR N.T.S. H-2 B I -FOL.D DOOR HEAD DETAIL. N.T.S. T-1 THRE5H OLD DETAIL. N.T.S. 151A BY PEMKO NEW FLOORING 3' 1/4' EXISTING CONCRETE SLAB No. 10 x 1-1/2" FHWS, PHILLIPS (FACTORY PROVIDED) • COLOR SELECTION AND 151A HALF SADDLE, 1/4' X FINISH BY OWNER 3% FLUTED -2 THRESHOLD DETAIL_ N.T.S. r- U kn w AL to H Q W z FRAME HEAD RABBET HINGE � DEADLOCK STRIKE --- (t HOSPITAL ARM PULL (LOWER BASE) AND PUSH PLATE 4. PUSH BAR AND PULL (t STRIKE FOR KNOB LOCKS, HANDLE SETS. ROLLER LATCHES 4 EXIT DEVICES HINGE SCHEDULED FLOOR BOTTOM OF FRAME TYPICAL. DOOR DETAIL. N.T.S. t 0 r DCIOF� C 00 M DOOR p00R DOOR DOOM? SIZE FRAME DETAILS HDW SE=T LABEL AUTO. DOOR, REMAR<5 NO. NO. TYPE MAT. UJ�'H. HGT. TH. MAT. JAMS HEAD `>~RESN. ND. ASSEM. (A.D.) 100 100 A ALJGL. 3'-0' -1'-0' 1 3/4" ALUM. f _ - - # EXISTING W/ DOOR CLOSER V 101 101 B WOOD 3'-0" -1'-0' 13/4111 METAL J-1 W-1 T-2 - - - 101A 101A C WOOD 2'-0' 11-0' 1 3/4 - * H-2 - - - - 102 102 B WOOD 3'-01 -I'-0' 1/4 HM J-) H-1 T-1 - - _ LOCATED EXISTING DOOR WITH 00 CLOSER_ 103 NOT USE 104 104= 8# WOOD{ 3'-0' 1'-0' 13/4 HM - • EXISTING W/ DOOR CLOSER 100 105 15 METAL 3'-0' -7'-0' 1 3/4' HM - - B EXISTING W/ DOOR CLOSER 105 G-1 4 2 - PLYWD. 2'-81 2'-56 1' - - - - - - WITH AUTOMATIC CLOSER F_...)00fR NOTE5 1. ALL DOORS AS SHOWN ON FLOOR PLANS ARE EXISTING TO REMAIN. 2. CONTRACTOR SHALL NOTIFY ARCHITECT IF ANY EXISTING DOORS (FIRE RATED OR OTHEWISE) ARE FOUND DEFECTIVE OR NOT MEETING STANDARDS SET IN THIS CONSTRUCTION DOCUMENT SET. 3. ALL EXISTING DOORS HAVE ACCESSIBLE HARDWARE. 4. DOOR NUMBERS CORRESPOND WITH ROOM NUMBERS FOR EASE OF IDENTIFICATION. SEE FLOOR PLANS FOR LOCATIONS. 5. DOORS, JAMBS, AND TRIM TO BE PAINTED WITH DTM BONDING PRIMER AND DTM ACRYLIC COATING PAINT. SEMI -GLOSS FINISH. (COLORS BY AU BON PAIN). (. ALL HARDWARE AND FRAMES SHALL MAINTAIN THE INTEGRITY OF THE FIRE RATING OF THE DOORS. 7• PROVIDE SMOKE TIGHT CAULKING AROUND ENTIRE PERIMETER OF FRAMES. S. USE DOUBLE (ATTACHED) 20 GAUGE METAL STUDS AT JAMB OF ALL DOOR OPENINGS IN METAL STUD PARTITIONS. S. CONTRACTOR SHALL FIELD VERIFY THICKNESS OF ALL EXISTING PARTITIONS ACCOMMODATING NEW DOORS IN ORDER TO DETERMINE THE "THROAT" DIMENSIONS OF NEW FRAMES. 10, SEE FLOOR PLAN FOR EXACT DOOR SWING. 11. NO KNOCK -DOWN FRAMES SHALL BE PERMITTED THROUGHOUT. 12. FOR DOOR JAMB, HEAD AND SILL DETAILS, SEE SHEET A-5 13. ALL WOOD DOORS TO BE SOLID CORE UNLESS OTHERWISE NOTED. SEE SPECIFICATIONS. 14. ALL DOORS SHALL BE PROVIDED WITH A 5/0" UNDERCUT. MAXIMUM CLEARANCE BETWEEN CITY 1 �OU'TH MIARV suII.I 1I�t f)r-p7, THE BOTTOM OF THE DOOR AND THE CONCRETE SLAB SHALL BE 3/4" MAX. EXCEPT AT THRESHOLD CONDITIONS.,t.:; �Trvuc 15. CONTRACTOR SHALL VERIFY SIZE OF ALL DOOR OPENINGS AND CONTACT THE ARCHITECT1`,cc IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING DOORS AND/OR FRAMES.`✓"`r°. 1�. ALL "B" LABELED STAIR DOORS TO BE 450' TEMP. RISE IN 30 MINUTES. 1-1. USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED).KNURLED LEVER HANDLES SHALL BE PROVIDED AT ALL TELEPHONE CLOSETS, MECHANICAL AND ELECTRICAL ROOMS. I& DOOR HANDLES SHALL BE MOUNTED Q 4S" A.F.F. (MAXIMUM). + V. Is. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10 DEGREES, hQA4,, �- ADF_ COURY rjRkr pn THE DOOR WILL TAKE AT LEAST 3 SECONDS TO CLOSE TO A POINT 3 INCHES FROM THE y LATCH." �_,_..., t�IM•lcr� k17 ° � 20, THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS : a) REQUIRED FORCE FOR EXTERIOR HINGED DOORS'IS = S.5 Ibf b) REQUIRED FORCE FO INTERIOR HINGED DOORS IS = 5 Ibf c) REQUIRED FORCE FOR SLIDING OR FOLDING DOOR IS = 5 Ibf 21, ALL DOORS IN THE MEANS OF EGRESS SHALL BE SINGLE ACTION RELEASE, SHALL COMPLY WITH F.A.C.AND SHALL NOT REQUIRE THE USE OF A KEY , TOOL OR SPECIAL KNOWLEDGE TO OPEN FROM THE EGRESS 51DE. 0 EXISTING IMPACT RESISTANT DOOR AND GLAZING moor 74rFE5 O FLUSH to " x 12 " S/S PUSH PLATE 12" k S/S KICK. PLATE BI -FOLD/ HALF LOUVER PLASTIC LAMINATE rt� It^ I I FLOOR u LINE — — — Cs-1 Cs-2 Revisions: 1�1 0 z (Oi Z 0 0 A DRAWN: OLP CHECKED: LEN DATE: 02 -18-08 SCAM: NTS- SEAL .'S ,..� OF r 4; �I±U A Sheet NO. A-5 OF 9 JOB # 21033