08-985(2)-001ABBREV1A-T1-0N-,..'.-S'.- a Cf5 LV 16 It M 0 rn" N 0 G U c m O , y 0 ni GENERAL NOTES I. CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS FOR ALL SYSTEMS AND EQUIPMENT TO BE I PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION. EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS CONNECTION THE'ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO- VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW- NER 2.- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN TI-E CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON- TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE _ TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE RE -DONE. 1 4. SHUTDOWN OF UTILITIES, IF A SHUTDOWN OR ANY TYPE OF INTER- FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAC TOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA- IN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER (PROPERTY NOT NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION DURING THE B1DDiNG PERIOD. 1F THE DISCREPANCY COMES UP DURING THE CONST'RUPCE ONJT. 1$ ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE D112ECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM- MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. S.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC _ TION CONTRACT, 9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH Tt-Ei WORK, 10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE. II.- PROVIDE ELECTRIC INSULATION BETWEEN ALL ISSIMILAR METAL AND ALSO BETWEEN CEMENT AND METAL. 12.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. IS.- CONTRACTOR TO REVIEW ALL EXISTING BUILDINGS STEMS AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY NON -CONFORMING ITEMS TO ARCHITECTS AND ENGINEERS ATTENTION. 14.- GENERAL CONTRACTOR IS TO PROTECT EXISTING AJACENT AREAS TO WHEW RE ORK IS TO BE PERFORMED, ANY EX STING MILLWORK, EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15.- DRAWINGS ARE SC4-EMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME. 16.- ALL WOOD BLOCKING WITHIN BUILDING 5TRUCTU2E, 614ALL BE FIRE - RETARDANT TREATED AS PER SPECIFICATIONS. 17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS / PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. I8.- ELEVATION AND LEVELS; A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19.- ALL INTERIOR GYPSUM WALL BOARD i5 5/8, TYPE X G.W.B. ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF WATER RESISTANT G.W.B. 20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS. AND JANITOR'S CLOSETS. 21.- BEFORE PATCHING ANY FIRE - RATED C.M.U. P 1 RTITION. FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22.- PROVIDE FINISH WALL UNDBR AND BEHIND ALL EQUIPMENT AND CASEWORK. 23.- LOCATION AND SIZE OF CEILING AND WALL. ACCESS PANE S SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. TI-E CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO INSTALLATION. 24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS, 25.- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS= A. ELECTRIC CLOSETS C. MECHANICAL;ROOMS B. TELEPHONE CLOSETS D. STAIRS 26,- WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION( OF SPACES WITH APPROPRIATE FIRE S.T.0 MATERIAL. 27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING MOUNTED MECHANICAL, ELECTRICAL FI ,IXTURES, 29.- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN kL G.WB. PARTITIONS EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 7-V. UNLESS OTHERWISE NOTED. 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE- MENTS. CONT12ACTCQSH-IALL PROVIDE ALL NECESSARY INSULA- TION/FIRE PROTECTIVE COATINGS. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWING TO ARCHITECT AND THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT. EB0000924 LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS 2600 DOUGLAS RD. SUITE 605 CORAL GABLES, FLORIDA 33134 TELEPHONE: (305) 444-1679 FAX: (305) 448-1405 E-MAIL ADDRESS: GRALMAIL@LJAAPA.COM 0I i1 O A Aa c e c O FLoRrow LICENSE OAw0002689 7400 N.W. 7th Street Suite tOf Miami, Florida. 33126 TeL• (305)265-7177 Fax: (305)262-8435 LUfS E. NAYA, A.L!► FI. AR0008063 PROJECT NUMBER: 27033 INDEX OF DRAWINGS ARCHITECTURAL A-1 DEMOLITION PLAN, LEGEND AND NOTES. A-2 FLOOR PLAN, LEGEND AND NOTES. A-3 REFLECTED CEILING PLAN, LEGEND AND NOTES. A-4 EQUIPMENT PLAN, INTERIOR ELEVATIONS, LEGEND AND NOTES. A-5 DOOR SCHEDULE, NOTES AND DETAILS. A-5 FINISH SCHEDULE, DETAILS, NOTES AND PARTITION TYPES. A-7 PENETRATIONS AND FIRE RATING DETAILS. A-5 PENETRATIONS AND FIRE RATING DETAILS. A-9 PENETRATIONS AND FIRE RATING DETAILS. MECHANICAL MO.00 SYMBOLS LEGEND, AND GENERAL NOTES - ];VAC. M3.00 DEMOLITION FLOOR PLAN - HVAC. M3.01 DEMOLITION FLOOR PLAN - CHILLED WATER PIPING - HVAC. M3.02 FLOOR PLAN - HVAC. MS-03 FLOOR PLAN - CHILLED WATER PIPING - HVAC. M7.00 DETAILS -- HVAC. PLUMBING PO.00 SYMBOLS LEGEND, AND GENERAL NOTES. P3.00 FLOOR PLAN AND PARTIAL DEMOLITION FLOOR PLkN. P5.00 DOMESTIC WATER AND SANITARY ISOMETRIC RISER DIAGRAM. P7.00 DETAILS. BUILDING INFORMATION ORIGINAL BUILDING DESCRIPTION ELECTRICAL EO.00 SYMBOLS LEGEND, GENERAL NOTES AND LIGHTING FIXTURE SCHEDULE. E3.00 DEMOLITION FLOOR PLAN LIGHTING. E3.01 DEMOLITION FLOOR PLAN POWER. E3.02 FLOOR PLAN -- LIGHTING, E3.03 FLOOR PLAN - SYSTEMS. E5.00 RISER DIAGRAM. E8.00 PANEL BOARD SCHEDULES. FIRE PROTECTION FPOAO SYMBOLS, LEGEND AND GENERAL NOTES. FP3.00 FLOOR PLAN. JURISDICTION : SOUTH MIAMI, MLAMI DADE COUNTY PRIMARY USE CLASS : GROUP "S" SPECIAL STORAGE OCCUPANCY NUMBER OF STORIES : 9 LEVELS (OPEN AUTOMOBILE PARKING GARAGE) NEW PROJECT DESCRIPTION PROJECT AREA: : TOTAL: 1, 800 S.F. SPRINKLED : FULLY SPRINYLERED FLORIDA BUILDING CODE 2004 EDITION FLORIDA FIRE PREVENTION CODE 2004 EDITION REVISIONS ARCHI I M: M - AMMFI S IAVT _0 r: UOR" ✓ Pr,-z5 * AATTCsLE L LENGTH C CENTERING LAM LAMINATE O DIAMETER LAV LAVATORY POUND OR NUMBERL59 POUNDS A 1_06/14R POUNDS PER HOUR LD LINEAR DIFFUSER A/C AIR CONDITIONING LP LOW POINT ACI AMERICAN CONCRETE INSTITUTE LT LIGHT AC P AME5TOS CEMENT PIPE ti AC5C ASPHALTIC CONCRETE SURFACE COURSE ACU AIR CONDITIONING UNIT MAIL MATERIAL ACT ACOUSTICAL CEILING TILE MAX MAXIMUM AD AREA EA DRAM MC MEDICINE CABINET ADJ A MEGH MECHANICAL A/E AWAMCT/ENGMEER MFR MEMBRANE AF ACCESS FLOORING MIN MANUFACTURER AFF ABOVE FINISHED FLOOR MIN MINIMUM A <sR AC<vREGATE MISG MIS OUS AHU AIR HANDLMCs UNIT MO MASONRYNRY OPENING ALT ALTERNATE MTD MOUNTED AL ALUMINUM MTL METAL ANN ANNUNCIATOR MUL MULLION AN51 AMERICAN NATIONAL STANDARD$ INSTITUTE MULT MULTIPLE ANT ANTENNA AP ACCESS PANEL N Aft ACCESS PLENUM APROX APPROXIMATE ARCH ARCHITECTURAL N NORTH ASB ASDESTOS NEC NATIONAL ELECTRIC CODE 4SPH ASPHALT NC NOT IN CONTRACT NUM ASTM AMERICAN SOCIETY OF TESTING 4 MATERIALS OMER M RO NOMINAL 15 NPL NAME PLATE 15AT 15AMRY NTS NOT TO SCALE CD BOARD Q 15ITUM aITUMINOU5 DLDG CWLG DIN BLKCs i'SLOCKMG CA OVERALL CM BEAM OBS OBSCURE MOT DOTTOM OC ON CENTER OD OUTSIDE DIAMETER DIM) OFS OVERFLOW SCUPPER CAa CABINET OPP OPPOSITE 015 CATCH 5A5IN P CEM CEMENT CER CERAMIC CFM CUBIC FEET PER MINUTE PC PRECAST CONCRETE CCs COINER GUARD Pi PIPE JOINT CNP CRICKET HIGH POINT PL PLASTIC CI CAST 'IRON P LAM PLASTIC LAMINATE GIG CAST IRON COVER PLAS PLASTER CIP CAST IRON PIPE PLYWD PLYWOOD CJ CONTROL JOINT PNT PAINT CLG CEILING PT POINT OR PATIENT CLGD CEILING DIFFUSER PTD PAPER TOWEL DISPENCER CLKG CAULKING PTN PARTITION CLO CLOSET PTR PAPER TOWEL RECEPTACLE CLP CRICKET LOW POINT CLR CLOSER CMP C.ORRIJGATED METAL PIPE GZ CMU CONCRETE MASONRY UNIT GIRT QUARTER GNTR COUNTER QT QUARRY TILE CO CLEAN OUT CAL COLUMN COMM COMMUNICATION R CONC CONCRETE CONN C.OrINECT10N CON5T5 CONSTRUCTION R REAR CCNT CONTINUOUS RA RETURN AIR CPT CARPET TILE RAD RADIUS CT CERAMIC TILE R5 REINFORCED BEAM CTR CENTER RCPT RECEPTION CTSK COUNTERSUNK RD ROOF DRAIN REF REFEREWSE REMF REINFORCED REQ REQUIRED PaL DOUBLE RE5L RESILIENT DEG DEGREE FY.STR REGISTER DEPT DEPARTMENT RM ROOM DE51G DESIGNATION RO ROUGH OPENING DET DETAIL RUB. RAIN WATER LEADER DF DRINKING FOUNTAIN VG DOOR GRILLE DIA DIAMETER b DIAL DIAGRAM DIM DIMENSION S STUCCO D15R DISPENSER 5C 5CREE0 CONCRETE DN DO DOUN DOOR OPENING SCHED SCHEDULE DS1� DRY STANDPIPE SEC 5D SECOND !SMOKE DETECTOR DS DOM SPOUT SECT SECTION DW655 DRAWINGS SF SUPPLY FAN DWR DRAWER $a SPANDREL GLASS SGR SIC GRADE SHR SHOWER SHT SHEET EA EACH SIGs SIGNAL EC EPDXY COATING SIM SIMILAR EHD ELECTRIC HAND DRYER 5K SINK EL ELEVATION 5M SHEET METAL EJ EXPANSION JOINT SMK SMOKE ELEC ELECTRICAL SND SOUND ELEV ELEVATOR SPEC SPECIFICATION EMER EMERGENCY SPQR SPEAKERS ENCL ENCLOSURE 50 SQUARE ENGR ENGINEER SOFT SQUARE FEET EPNL ELECTRICAL PANEL SST STAINLESS STEEL EQ EQUAL ST STREET EQPT EQUIPMENT STC SOUND TRANSMISSION COEFFICIENT E5T ESTIMATE STD STANDARD ET EXPANSION TANK 5T-D STORM DRAIN EWC ELECTRIC WATER COOLER STL STEEL EXH EXHAUST STRL STRUCTURAL EXST EXISTING SUSP SU5PENDED EXT EXTERIOR SYM SYMMETRICAL SYS SYSTEM P T FA FIRE ALAF91 FAM FIRE ALARM BELL T TOILET FD FLOOR DRAIN T5 TIE 15EAM FG FMRIGLA55 TC TE COLUMN FCO FLOOR CLEANOUT TEL TELEPHONE FD FIRE DAMPER TEMP TEMPERATURE FDC FIRE DEPARTMENT COMIECTOR TtG TONGUE AND GLOVE FOR FIRE DOOR THK THICK FDN FOUNDATIONS TOC TOP OF CURB FDV FIR'r DEPARTMENT VALVE TOW TOP OF PARAPET Mc FIRE EXTINGUISHER CABINET TOS TOP OF SLAB FEX PIKE EXTINGUISHER TP TOP OF PAVEMENT FF FIN15W FLOOR TRD TREAD PH FIFE HYDRANT TS TU15ULAR STEEL FIN FINISH TSTAT THERMOSTAT FL FLOOR TV TELEVISION }�1 I FACTORY MANUAL TW TOP OF WALL FLASH FLASHING Tl P TYPICAL FLG FLANGE u FLOUR FLUORESCENT FOC FACE OF CONCRETE FOP FACE OF FINISH u5 UNDERCUT FOM FACE OF MASONRY UL UNDERWRITER'S LABORATORIES FOS FACE OF STUD UNF UON UNFINISHED UNLESS OTHERWISE NOTED FPRF FPM FIREPROOF FEET PER MINUTE U05 UNLESS OTHER SPECIFIED FRD FRENCH DRAIN uR UTIL URINAL UTILITY FS FULL SIZE FT FOOT OR FEET Y FTG FOOTINGS FT-1_15 FOOT POUNDS PURR FURRING VB VNYL CASE PUT FUTURE VCT VINYL COMP051TION TILE VERT VERTICAL VEST VESTIMLE co vF VERIFY IN FIELD VOL VOLUME GA GAUGE VT VAPOR TIGHT GAL GALLON VTR VENT THRU ROOF GALV G8 GALVANIZED t �1 GRADE GEAM q L L)TH T°+sll[\1v1! 9) GEN GENERATOR Cvvk '^ �O T� rS1,��LO�l WR WIRE GGL ND CRB GROUND RILL >3Loac + TLci W W/ WINDOW WISH GRD GRADE ',TTZ" r,TU AL. WC WATER CLOSET WCO WALL GLEANOUT c4m GYPSUM WALL BOARDWOOD :. WD GYP GYPSUM WF WWFAE5RIC HB HOSE 518 PC HANDICAPP'i"De"" 14CW HARDWOOD HDLLE HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL NP HIGH POINT WR HOUR HTR HEATER HVAC HEATING, VENTILATION, AND AIR CONDITIONING HYD HYDRANT I ID IN51DE DIAMETER C PIAM ) IN INCHES INT INTERIOR J JAN JANITOR Jd JUNCTION WX JCT JUNCTON JSK JANITORS SINK JT JOINT K KO KNOCK OUT W/O WITHOUT WP WATER PROOF WSCT WAINSCOT UALF UXLIM WELDED WISE FACSRIC WELDED WIRE MESH -.000