09-184(3)-100R R I G A T 1 0 N N 0 T E S 1.) SOME IDIPE. LINES ARE DRAWN OFF_ -SET FOR CLARITY, INSTALL ALL IRRIGATION LINES IN LANDSCAPED AREAS, 2.) REFER TO THE LANDSCAPE PLANS WHEN TRENCHING TO AVOID TREE ROOT BALLS AND TO INSTALL HEADS AT APPROPRIATE LOCATIONS. 3,) ADJUST ALL. NOZZLES 1-0 REDUCE OVERTHROW ON PAVING & WALLS, THROTTLE ALL IRRIGATION CONTROL VALVES AS REQUIRED TO PREVENT FOGGING. SET CONTROLLER RUN TIMES TO MATCH PLANT WATER NEEDS AND SOIL_ CONDITIONS. 4.) INSTALL RISERS 18" FROM WALLS AND A MINIMUM OF 12" FROM ANY SIDEWALK, OR ROAD. RISERS ARE TO BE PAINTED FLAT BLACK, 5.) TOP OF SPRAY AND ROTOR HEADS SHALL BE SET AT TOP OF SOD OR TOP OF MULCIA LAYERS. 6.) REFER TO UTILITY PLANS PRIOR TO TRENCHING. THE IRRIGATION INSTALLER SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE TO UTILITIES CAUSED BY THEIR WORK DURING THE PROJECT, 7.) ALL WORK SHALL BE GUARANTEED FOR ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AGAINST ALL DEFECTS IN EOUIPMENT AND WORKMANSHIP, 8.) ELECTRIC POWER SUPPLY FOR THE IRRIGATION CONTROLLER SHALL BE BROUGHT TO A JUNCTION BOX AT THE CONTROLLER LOCATION BY THE SITE MEP CONTRACTOR. 9.) IRRIGATION WATER CONNECTIONS AND SYSTEM CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF LOCAL CODES FOR IRRIGATION INSTALLATION AND CONNECTIONS 'TO THE WATER SUPPLY, 10,) SIXTY (60) PSI MINIMUM STATIC WATER PRESSURE IS REQUIRED FOR THE EFFICIENT OPERATION OF THE IRRIGATION SYSTEM AS DESICNED, VERIFY THE MINIMUM STATIC WATER PRESSURE IS AVAILABLE AT THE PRO,.,IECT SITE PRIOR TO BEGINNING THE IRRIGATION INSTALLATION. NOTIFY THE LANDSCAPE ARCHITECT IF THE MINIMUM STATIC WATER PRESSURE IS NOT AVAILABLE. SHRUB NOZZLE ADAPTOR AND SPRAY NOZZLE 1/2" SCHAO PVC, PAINT FLAT BLACK 3/4" ANGLE IRON RENFORCEMENT Lj CL EXTEND 2' ABOVE FINISHED GRADE NYLON DP STRIP FASTENERS PANT FLAT BLACK RMSHED GRADE PVC FEMALE ADAPTER THREADED STREET ELL 200 PVC LATERAL REFER TO PLAN FOR UNE SIZE \\--SCH, 40 PVC TEE RUNG SHRUB RISER X III -a 1-1-f GATE VALVE NOT TO SCALE ROUND VALVE BOX. CAST IRON GASKETED GATE VALVE --NON RISING STEM REFER 'TO RRIGATION PLAN AND KEY PVC EXTENSION AS NEEDED hilIIIIE: E-E I EXCAVATED MATERIAL, IRRZTION_ m _T_ --------COMPACTED EXCAVATED MATERIAL N01 TO SCALE I R R I G A T 1 0 N L E G E N D IRRIGATION WATER TAP AND WATER METER. SIZE INDICATED ON PLAN. PROVIDED BY THE IRRIGATION INS -FALLER, PER LOCAL. CODES. REDUCED PRESSURE BACKFLOW PREVEN TER. PROVIDED BY IRRIGATION INSTALLER, PER LOCAL CODES. WATTS 909, OR EQUAL. IRRIGATION CONTROLLER WI TH RAIN SWITCH. NUMBER OF STATIONS A INDICATED ON PLAN. 120 VOLT, 3 AMP, ELECTRIC CIRCUIT FROM NEAREST ELECTRICAL PANEL, BY THE SITE MEP CONTRACTOR. RAINBIRD ESP--L.X SERIES WITH MINI —CLICK RAINSWITCH. IRRIGATION CON FROL VALVE. PLASTIC BODY WITH FLOW CONTROL. MOUNT IN 15" RECTANGULAR VALVE BOX. SIZE INDICATED ON PLAN, RAINBIRD PEB PRS VALVE SERIES, OR EQUAL. 1" BRASS QUICK COUPLER VALVE. MOUNT ON 0---RING TYPE SWING JOINT AND STABILIZE IN 10" ROUND VALVE BOX. PROVIDE ONE QCV KEY WITH 3/4" HOSE SWIVEL ADAPTER PER TWO QUICK COUPLER VALVES. RAINBIRD 44LRC VALVE WITH 44K KEY + SH--1. A 4 IRRIGATION CONTROL VALVE TAG. INDICATES VALVE LOCATION, STATION 55 NUMBER, SIZE AND ZONE FLOW RATE. IRRIGATION ISOLATION VALVE. SIZE SAME SIZE AS PIPE. MOUNT IN 10" ROUND VALVE BOX WITH 6" DIAMETER PIPE EXTENSION AS NEEDED. 2.5" AND SMALLER -- BRONZE THREAD ON TYPE WITH WHEEL HANDLE, PROVIDE ONE VALVE KEY FOR EACH TYPE VALVE INSTALLED. SIZE PVC MAIN LINE PIPE. CLASS 200, PVC. INSTALL 18" DEEP. m m m 25' AND SMALLER, SOLVENT WELD PVC PIPE AND FITTINGS. SIZE PVC LATERAL LINE PIPE. CLASS 200, PVC. INSTALL 12" DEEP. 2. a'" AND SMALLER, SOLVENT WELD PVC PIPE AND FITTINGS. SIZE SLV. PVC SLEEVE PIPE. SCH 40, PVC. SOLVENT WELD PVC PIPE AND FITTINGS, PROVIDE NOZZLE PER PLAN NOTE, INSrALL SPRINKLER AT FINISHED GRADE IN TURF, Fall - 11- 1 E- ABOVE MULCH IN BEDS, I E. I I APPROVED BACKFILL. DO NOT USE SIDE INLET WHEN PRESSURE RECULAWN IN HEAD DOES NOT ALLOW, SPRAY SPRINKLER BODY 18" OF FLEXIBLE PVC PIPE AND THREADED f-MING /----4-ATERAL PIPE LATERAL IEE POP UP SPRAY BODY NOT TO SCALE MAIN SUPPLY, LATERAL AND CABLE OR VARING TYPICAL TRENCHING 41Y<UL IN bUX ,ROOF CONNECTION BADE CON TROL VALVE - FED ON PLAN CONCRETE BRICK ET BOX ELEVATION SEAL BOTTOM OF VALVE PIT, BRICK RESTS ON PIPE) PVC MAINLINE PIPE 18" MIN, DEPTH TES BENEATH PIPEWORK ERAL PIPE 12" MIN, DEPTH REMOTE CONTROL VALVE NOT TO SCALE NOT TO SCALE S P R A Y B 0 D I E S RAINBIRD 1800 SERIES SPRAY BODIES & ADAPTERS USE FLEXIBLE PVC CONNECTIONS PROVIDE MPR SPRAY NOZZLES PER PLAN s * 6" POP—LJP TURF SPRAY BODY T A 12" POP—UP SHRUB SPRAY BODY R E X" SHRUB NOZZLE ON PVC RISER SPRAY HEAD NOZZLE CHART TTER _ E_ LE AT lu PATTERN 30 PSf A 0.9 15' QUARTER e 1.25 15' ONE THIRD c 1,85 15' HALF D 2.5 15' TWO THIRD E 2,81 '1,5' THREE QTR. F U FULL G O65 12' QUARTER H j �_ 2 ONE THIRD 1_3 12' HALF K —4-. 1?-'- , TWO THIRD L 1.95 12' THREE QTR. m 2.6 12' FULL 0.4 10' QUARTER p 0,5 10' ONE THIRD R &8 10' HALF u O.6 4' X 15' END STRIP v 1.2 4' X 30' SIDE STRIP w 1.2 4' X 30' CENTER STRIP x 1.7 9' X 18' SIDE STRIP zio VARIES 10' 10' ADJUSTABLE ARC Z12 VARIES 12' 12' ADJUSTABLE ARC z VAMES 15' 15' ADJUSTABLE ARC y 0.5 2' ADJUSTABLE FLOOD BUBBLER 0 1.0 5' STREAM BUBBLER —QUICK COUPLER VALVE, POSITION IN VALVE BOX SO THAT KEY MAY BE OPERATED WTHOUT INTERFERENCE, -1" ANGLE IRON - 24" LONG SECURED TO QUICK COUPLER WITH 2 STAINLESS STEEL HOSE CLAMPS. 10" ROUND PLASTIC VALVE BOX ,---0--RlNG PVC TRIPLE SAING JOINT, SAME SIZE AS QUICK COUPLER, r---THREADED SERVICE TEE BRASS QUICK COUPLER VALVE EXTERNAL WALL MO9JNT IRRIGATION CONTROLLER WITH INTERNAL 3—WIRE STEP DOWN TRANSFORMER AND LOCKING CABINET. SECURE TO BUILDING WALL 1.5" PVC SCH. 40 CONDUIT AND FITDNGS JUNCTION BOX I" PVC SCH. 40 CONDUIT TO POWER SUPPLY WIRES TO REMOTE CONTROL VALVES ­ 24 VOLT SECONDARY CIRCUIT —120 VOLT, 3 AMP, 3 WIRE PRIMARY CIRCUIT FROM DEDICATED BREAKER IN ELEC, PANEL PER CODES, BY ELECTRICAL. CON11RACTOR, WALL MOUNTED CONTROLLER NOT TO SCALE NOT 70 SCALE 18" Max 12" Min L_ Consultants mI Viles Rd. Stifte# 105B Coral Springs, FL 33067 PH: 954-20-8839 Fax: 954-773-9841 www.fmb*_m0qj&A ,AMP I --------MARK LOCATION OF SLEEVE WITH A OFFICE TZ SECTION PVC RPE .AANT LOCATE BOTH ENDS OF SLEEVE IMPROVEMW FOR .___EXTEND ALL SLEEVES 2'-0" BEYOND • EDGE OF PAVEMENT, TYPICAL DECK PAVEMENT ,PR.,, LEA R. FUSHED GRADE -VARIES PEREZ - Q&*AIROS V-0" VITY 6310 SUPjA!�j#9?A(E MIAMI, FLORID"143 ­d I I G ill e Vsions Date SUB -BASE FILL/PLANTING FlLL/EXlSTUG�0U.____­ CONDITION VARIES ________,________SCflEDULE 40 PVC SLEEV SIZE AS NOTED ON PLANS�- -----S CAP BOTH ENDS OF (_EEVE BELOW GRADE AND LEAVE CM-�S­jl-_--�_._.�_____ UNGLUED ON PVC SLEEVE 7') UNDIS7URBED SOIL SLEEVE. UNDER PAVIN NOL-, !W: "7 Seal , 0'T 0�, 40— FIBERGLASS Etkt,;6URE -----BRONZE RPD BACKFLOW PREVENTER PER LOCAL CODES, PROVIDE 'TRUE UNION THREADED COUPLINGS. nj I F; -16- 'MOO, ",—OUT 1-0 IRRIGATION IN FROM IRRIGATION Ched(ed By: WATER SUPPLY SYSTEM 'D.F. Drawn By. J.S. RR D BACKFLOW PREVENTER NOT TO SCALE Issue: xx-xx-xx Date- 02-13-08 Shftt Index: IRRIGA-ITION D IE TA I L S & NOTES sheet Number. LA- . 0