09-184(3)-082S1r�
2 HOUR FIRE RATED THROUGH
PENETRATION FIRESTOP FOR SINGLE
P C PIPE THROUGH
+�
GYPSUM WALLS USING
e
TREMSTOP WS AND TREMSTOP MCR.
WL 2063
DRAWING NOT TO SCALE
F—RATING = 2 HR.
T—RATING = 1 HR.
3
2
5 4
PRE —RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY
l�s
PLASTIC PIPE —
NOW 4" DIAM. (OR SMALLER) SCH. 40 PVC PIPE FOR USE IN OPEN OR CLOSED
PIPING SYSTEMS.
A MAX. ANNULAR SPACE OF 1/8" IS REQUIRED WITHIN THE SYSTEM.
TREMSTOP WS —
INTUMESCENT WRAP STRIPS, CONTINUOUSLY WRAPPED AROUND THE OUTER
CIRCUMFERENCE OF THE PIPE SIX TIMES ON BOTH SIDES OF WALL ASSEMBLY.
TREMSTOP MCR —
PREFABRICATED STEEL COLLAR WRAPPED OVER THE WRAP STRIPS (ITEM 3)
AND MECHANICALLY FASTENED TO BOTH SIDES OF THE WALL ASSEMBLY.
E—SIL -- MIN.
1/4" THICKNESS OF SEALANT APPLIED AT THE INTERFACE OF THE WALL
AND COLLAR, AND
THE INTERFACE OF THE COLLAR AND PIPE. SEALANT APPLIED ON BOTH
SIDES OF WALL.
�s►, 2 HOUR FIRE RATED THROUGH
Uvuo' PEN TION FIRESTOP FOR
SINGLEMETAL PIPE THROUGH
CONCRETE FLOORS OR WALLS USING
777e E-SIL
WL 2061 I DRAWING NOT TO SCALE
I F-RATING = 2 HR
T-RATING = 0 HR
2
3B
1
3B 36
2 3
1 FLOOR OR WALL ASSEMBLY = 4.5" THICK CONCRETE
2 COPPER TUBING - 4" (OR SMALLER) TYPE L (OR HEAVIER)
COPPER, ANNULAR SPACE 15 M N 1 2"
�s A) PACKINGMATERIAL - MIN 3 1/2 " THICKNESS (MIN 6 PCF)
MINERAL' WOOL INSULATION
B) MIN 1/2" THICKNESS FYRE-SIL INSTALLED WITHIN ANNULUS
NOTE: FOR WALLS APPLY E-SIL TO BOTH SURFACES OF WALL,
r FIRE
RATED
THROUGH
PENETRATION
* • .
E THROUGH
CQNCRETE iiO. #rjj—S USING
TREMSTOP WS AND TREMSTOP MCR.
DRAWING NOT TO SCALE
F-RATING = 2 HOUR
T-RATING = 1-1/2 HOUR
(DPRE—RATED CONCRETEIFLOORSBLOCK
PLASTIC • r' ►R PVC PIPE FOR
USE IN CLOSED OR OPEN
PIPING SYSTEMS. A NOM. ANNULAR SPACE OF 1/8- IS REQUIRED WITHIN THE
FIRESTOP SYSTEM, I
• ',:firINTUMESCENT WRAP STRIPS, WRAPPED AROUND OUTER
CIRCUMFERENCE
s OF THE
PIPE FOUR TIMES.
(a)TREMSTOP r PREFABRICATED
•♦••,. STEEL COLLAR r r• i r THE •* s :IF
'O•#r *i. f
ADDITIONALAND MECHANICALLY FASTENED TO THE
WALL ASSEMBLY.
FYRE—SIL — MIW 1/4'- BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE
SLAB AND STEEL COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE.
AN BEAD •PAROUND
THE PIPE AT THE INTERFACE WITH THE TOP OF
NOTE:err••
APPLYIN WALLS, O EACH SIDE OF ASSEMBLY.
1 OR 2 — HOUR FIRE RATED GYPSUM WALLBOARD/STUD ASSEMBLY
A) STEEL PIPE — 6" DIAM.(OR SMALLER) SCH. 40 (OR HEAVIER) STEEL
CONDUIT 1 O.SMALLER) EMT r RIGID
r r r
s
M FILL MAX. 3/4- ANNULUS AT A THICKNESS
6" MIN.
HOT WATER OUTLET --",9
TO FIXTURES
HOT WATER OUTLET
OM LOOP --
ELECTRICAL JUNCTION BOX
(USE ONLY COPPER
TO ELECTRICAL DISTRIBUTION PANEL
UNION
TEMPERATURE & PRESSURE RELIEF VALVE
,s`� ANODE
�o' -UNION
CONDUCTORS}-- 1 MIN. j
RECIRCULATING ASSEMBLY .
REFER TO aErAIL
CW SUPPLY
JACKET ACCESS EXPANSION TANK
PANELS
AIR GAP 6"
•
DRAIN VALVE AIR GAP
FITTI NG
AUXILIARY
CATCH PAN T&P LINE TO
DP LINE TO TERMINATE TERMINATE
OUTSIDE 6" AFG OUTSIDE 6" AFG
TYPICAL ELECTRICAL WATER HEATER DETAILS
ZL
GONG. SLAB
A
L-1 1 /2*X1 1 /2-X1
1 /2"0 ALL -THREAD ROD
HANGER WITH DOUBLE
NUT TOP AND BOTTOM
AT 8'--0" O/C
ADJUSTABLE CLEVIS
PIPE HANGER
HEX NUT GRINELL OR EQUAL
AND BOLT (SIZED AS REQ'D)
i
I
PIPE (SEE PLAN
24 GA. SHEET METAL PIPE FOR SIZE)
SADDLE MIN. LENGTH SHALL
BE 2 TIMES DIA• OF PIPE
OR 12" WHICHEVER IS
GREATEST.
(HORIZONTAL)
TYPICAL PIPE HANGER
(WITHOUT/INSULATION) N.T.S.
3/8" SELF DRILLING
PIPE TO SYSTEM
BALL VALVE
SEE PLANS FOR
CONTINUATION
CHECK VALVE
NIPPLE
IN —LINE CIRCULATING
PUMP GRUNDFOS MODEL
UP25-64SU 1/12 HP
DIELECTRIC UNION TYPE
(115V/10/60 HZ)
CONNECTION SO PUMP
CAN BE REMOVED FOR
I
SERVICE ( )
1
NIPPLE
PIPE FROM SYSTEM
BALL VALVE
SEE PLANS FOR
CONTINUATION
RECIRCULATING
U DETAIL
SCALE: N.T.S.
COVER SECURED
WITH SCREWS
THREADED C.O. PLUG
FIN. GRADE
FLUSH W/FIN.
GRADE
ADJUSTABLE COLLAR
THREADED C.Q. PLUG /
FIN. FLOORS /
WALL
TYPICALCLEANOUT DETAILS
!#IN. G' MANHOLE COO '
CONCRETE OR PAVEMENT
� � �� /i�
LOCKABLE
RATE -TIGHT i...l.iz6KAB CAP
MIN, SLOPE 2`
MIN,µ
12' STEEL COLLAR ,
I
R . =U M11MM PAD
2r MIN, ,IQ''
MIN
i' a BENTDNITE OR FINE SAND SEALANT
'*
si isa PVC RISER
-j
.•- WASHED SILICA SAND PACK
,.,I
WELL SCREEN SCH 40 PVC SLUTTED PIPE
J
M13RIZONTAL FACTORY CUT 0.01' HM,
2' MIN.
STATIC GGROUNDVA`I'ER TABLE
J
NEITEI
D C�R-(�fE("EN AT
tE.gX�^' xTE: "Fg ��t"�}IEL.L�S^
�y IAMETER
BELOW THE BOTTOM OF THE -�
TANK. IN ALL CASES
WELLSCREEN MUST BE AT J
LEAST FIVE FT, INTO
HE GROUNDS //TER
d
fLA
CAP Btri TOM
3 - 3
_ MIN, MIN.
ITORING WELL DETAIL
CONDENSATE A/C UNIT
DRAIN LINE DRAIN
CONNECTION
TRAP
2" MIN
2" MIN
NOTE.
INSTALLATION OF PIPING SHALL
CLEAR FILTER PULL—OUT SPACE
AND REMOVABLE SERVICE PANELS.
TYPICAL CONDENSATE PIPING
CONNECTION DETAIL
N.T.S.
2' GOOSE OVER
FLOW PIPENECK
SEEER-Ill1 ar
=11 1T�I' 1 -- 1�11=1•-11 I1=_2111
0P
r_
a
ILIE CONDENSATE
DRAIN 1 PIPE
FRENCH DRAIN 2eOX24'
DEEP PVC OR EW&
PIPEINMOUT COVER.
� ..
FII.LED MHED
ROCK MINIM SEPARATION
MOM C ►
FRENCH DRAIN
PIPE SEE FILM.',
r SCHEDULE
S FLOOR HANGER
AT EVERY OTHER FLOOR
(TYPICAL)
:I
FIRE STOPPING " CONC. SLAB
SEE ARCHITECTURAL
FOR DETAILS
FLOOR SUPPORT PIPING DETAIL
N.T.S.
PLUMBING DETAILS
I{ III I■I■11
SIR J Ei
�►
y
i
.•
IN'TtRIOR,
811 PONCE BLVD.
CORAL GABLES, FL 33134
TELEPHONE (305) 441-1556
i
httP://www.S-9architeCf&cOrn
AA C001330
CONSULTANTS
.",
ENGINEERS
809 SW 8 Street, No,00 Florida 33130
i
i
��■
.:.A.....
:) ui
C
ui
It
LL
:
<
i
•r
LL
REVISIONS_
r+
COMMENT
i
i
I
I
i
Lp
.. ..
"t3yi ICERAN
S&G PROJECT NO.
0723700
;
CHECKED BY:
DRAWNr
«-
1.25.2008
IDATE-
1.25.2008
SHEETiNDEX
r •
DETAILSING
P-5.0