09-184(3)-044FINISH SCHEDULE ROOM. NO. ROOM NAME I AREA FLOOR MATERIAL BASE MATERIAL WALL FINISH CEILING MATERIAL REMARKS NORTH EAST SOUTH WEST 100 MAIN ENTRY GL 24X24 GLB WC WC WC WC AS SHOWN 101 LOBBY / WAITING AREA GL 24X24 GLB WC WC WC WC ASC 102 RECEPTION AREA GL 24X24 GLB WC WC AP WC 103 NOT USED 104 A/C. #2 CLOSET CPT VN B PT PT PT PT DW 105 CLOSET CPT VN B PT PT PT PT DW 106 MULTI -PURPOSE RM. CPT VN B PT PT PT PT ASC 107 I.T. CLOSET VN VN B PT PT PT PT DW 108 DR. OFFICE #1 CPT VN B PT PT PT PT ASC 109 OFFICE MANAGER CPT VN B PT PT PT PT ASC 110 HALLWAY GL 24X24 GLB WC WC WC WC DW ill 112 FACIAL ROOM #1 FACIAL ROOM #2 VN VN VN B VN B WC/MO WC/MO WC WC WC WC WC WC ASC ASC 113 EXAM-8 VN VN B WC WC WC/Mo WC ASC 114 DR. OFFICE NOA CPT VN B PT PT PT PT ASC 115 DR. OFFICE NO.2 CPT VN B PT PT PT PT ASC 116 A/C. #3 VN VN B PT PT PT PT ASC 117 V.I.P. WAITING VN VN B PT/MO PT PT PT ASC 118 WORK AREA GL 24X24 GLB WC WC WC WC ASC 119 EXIST. TOILET GL 24X24 GLB PT PT MID PT DW 120 EXIST, TOILET GL 24X24 GLB MID PT PT PT DW 121 HALLWAY GL 24X24 GLB WC WC WC WC ASC 122 FACIAL VN VN B WC1M0 WC WC WC ASC 123 FACIAL VN VN B WC WC WC/Mo WC ASC 124 NOT USED 125 NOT USED 126 CONSULTATION GL 24X24/MO GLB PT PT PT PT 127 DR. ASSISTANTS CPT VN B PT PT PT PT ASC 128 HALLWAY GL 24X24 GLB WC WC WC WC DW 129 CLO. GL 24X24 GLB PT PT PT PT DW 130 HALLWAY GL 24X24 GLB WC WC WC WC ASC 131 EXAM-2 VN VN B WC WC/MO WC WC ASC 132 EXAM-3 VN VN B WC/Mo WC WC WC ASC 133 REMOLDELED MEN'S RE!,STROOM GL 24X24 GLB PT PT Mo PT DW 134 REMOLDELED WOMEN'S RESTROOM GL 24X24 GLB M0 PT PT PT DW 135 LAB VN VN B PT PT PT/MO PT DW 136 PROCEDURE ROOM VN VN B PT PT PT/Mo PT ASC 137 A/C. #1 CLO. GL 24X24 GLB PT PT PT PT DW 138 CLO. GL 24X24 GLB PT PT PT PT DW 139 EXAM-4 VN VN B WC WC WC WC/MO ASC 140 EXAM-5 VN VN B WC WC/MO WC WC ASC 141 WAITING AREA GL 24X24 GLB WC WC WC WC ASC 142 143 PHOTO ROOM EXAM-1 VN VN VN B VN B PT WC PT WC/MO PT WC PT WC ASC ASC 144 I I W.H. I W+D. CLO. GL 24X24 I GLB I PT I PT I PT i PT I DW I I FINISH I F(;FNn GENERAL NOTES FOR WALL TYPES ALL INTERIOR FINISHES SHALL MEET I. STUDS GAUGES SHALL BE AS FOLLOWS: THE FOLLOWING REQUIREMENTS: 1. ALL WALLS AND CEILING FINISHES TO A. ALL STUDS EXCEPT 1-5/8') 10-0- HT. OR LESS = 25GA. BE CLASS: A B. ALL STUDS EXCEEDING 1V-O'HT. = 20GA. C. ALL STUDS I -518"= 20CA 2. ALL INTERIOR FINISHES IN CORRIDORS D. 18GA. METAL STUD FRAMING@ ALL WALLS SUPPORTING CABINETRY. SHOULD BE CLASS: A E. ALL STUDS@ WALLS WHERE CABINETS ARE TO BE AFFIXED MUST BE 18GA. ORB R 3. ALL GYPSUM WAALBOARD PARTITIONS, CEILINGS AND SOFFITS SHALL BE 5/8" 2. TILE BACKER BOARD IS TO BE USED AT ALL HORIZONTAL BATHROOM SURFACES. SUCH AS TUB DECKS, SHOWER SEAT, NICHES TYPEW. AND SILLS FOR STONE, CERAMIC OR MARBLE APPLICATION, ADHERENCE TO RECOMMENDATIONS CONCERNING SEALING EXPOSED EDGES, PAINTING, TILE ADHESION, FRAMING AND INSTALLATION IS NECESSARY FOR SATISFACTORY PERFORMANCE 4. FOR CEILING HEIGHTS, REFER TO REFLECTED CEILING PLANS (SHEETS 3. MOISTURE RESISTANT BOARD IS TO BE USED AT ALL AREAS EXPOSED TO MOISTURE AND ALL PIPE PENETRATIONS. A-4.01, A-4.02, & A-4.03). 4. TILE BACKER BOARD SHALL BE USED AT STONE / CERAMIC / MARBLE APPLICATIONS, 5. ALL GYPSUM BOARD CEILINGS SHALL BE PAINTED (TYP.). 5. FIRE RATED BOARD SHALL BE USED AT ALL FIRE RATED LOCATIONS ANDS BE CONTINUOS TO UNDERSIDE OF SLAB. ALL PENETRATIONS SHALL HAVE PROPER UL RATED FIRE SAFING PER ASTM E814 AND UL1479 TEST CRITERIA. 6. ABBREVIATIONS: 6. USE 6" METAL STUDS AT 24' D.C. AT WALLS WHERE ELECTRICAL PANELS AND PLUMBING LINES WILL BE INSTALLED. GL 24X24 = GLASS TILES GL B = GLASS BASEBOARDS 7. REQUIRED BRACING FOR STUDS SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR INSTALLING THEM. WC = WALLCOVERING CPT = CARPET 8. COORDINATE REQUIRED BLOCKING FOR ALL FUTURE GRAB BARS AT HANDICAP ADAPTABLE BATHROOMS. VN = VINYL TILES •VN B = VINYL BASEBOARDS 9. FOR VERTICAL AND HORIZONTAL REINFORCEMENT OF CONCRETE I MASONRY WALL IS) REFER TO STRUCTURAL DRAWINGS AND PT = PAINT PROJECT MANUAL SPECIFICATIONS. MID = MOSAIC GLASS ASC = ACCUSTICAL CEILING 10. ALL CMU. BLOCK TYPES TO BE MINIMUM 2 HP, RATED (TYPICAL), DW = DRYWALL DW = CHANGE IN ARCH PLAN 11. INSULATION TYPES (REFER TO ENERGY CALCULATIONS FOR REQUIRED RNALUES. A. R-1 I MINIMUM INSULATION @ ALL EXTERIOR WALLS. C. 1"EXTRUDED POLYISOCY ANURATE AT ROOF LEVEL FURRED CONCRETE CEILINGS, If f CEILING FINISH MAY OCCUFL REFER TO CEILING FINISH MAY OCCUR. REFM TO REFLECTED CEILING PLANS AND DETAILS. CEIM FINISH MAY OCCUFL REFER TO REFLECTED CUM PLANS AND DETAILS. REFLECTED CEILING PLANS AND DETAILS. 77. 17 GYPSUM BOARD. REFER TO (1) LAYER 17 GYPSUM BOARD 17 GYPSUM BOARD. REFER GENERAL NOTE XAND X, TO GENERAL NOTE XAND )L 1 5F STEEL STUD AT 24' D.C. NEW STUCOD FINISH B-FOLD INSULATION. REFER TO MATCH EXISTING. TO GENERAL NOTE X HORIZONTAL BRACING AS REQUIRED, REFM TO NOTE X REFER (1) LAYER ST GYPSUM WALLBOARD OR VENEER BASE APPUED AT RIGHT ANGLES OR 8CAtU BLOCK TO PARALLEL TO EACH SIDE OF 3 Sr METAL STUDS 24* O.G. WITH f TYPE S DRYWALL SCREWS GOUANOTE XANDX r0.11TOVERTICAL EDGES AND 17 O.C. TO TOP AND BOTTOM RUNNERS AND REFER TO RR PLAN D(TER)OR INTERIOR INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24" D.C. EACH SIDE ANDOPPOSITESIDES. 1 W METAL STUD AT 24'0.C. 3 5T METAL STUD AT 24'D.C. REFER TO GENERAL NOTE X REFM TO GENERAL NOTES, FLUB TO STRUCTURAL FLOOR FINISH MAX OCCUR. DRAWINGS FOR 3W CONTINUOUS SEALANT. REFER TO FINISH SCHEDULE DOTRIOR DROP AT SLAB. CONTINUOUS SEALANT FLOOR SLAB. FLOOR SLAB FLOOR SLAB Z_ FLOOR FINISH MAY =IF. :a--- FLOOR FINISH MAY OCCUR. HORIZONTAL CONTROL REFER TO FINISH SCHEDULE REFERTOFINISH SCHEDULE JOINT MAY OCCUR. CONTINUOUS SEALANT TYPICAL METAL STUD PARTITION 11 Q TYPICAL METAL STUD PARTITION 8aa TYPICAL METAL STUD PARTITION -Heerjy In6n, aknal 1'nC_. X: 811 Ponce De Leon Blvd. 6 W -Coral -Ggbles, FL 331' 3A 'E L: 'FAX- (=,,'44C-23.'4 http://www.s-garchitects.com 6 W AA 0002293 EB 0005176 ii Project Number 0723701 En z 0 Consultants el G.V. PIREZ iE STRUCTURAL ENGINEERS 7315 S.W. 87th AV MIAMI, FL 33173 TEL- 305-412-2200 Consultants 0. DESIGN ONE CONSULTING ENGINEERS CL 809 S.W. 8 STREET, No. 200 MIAMI, FL 33130 TEL- 305-860-0384 OFFICE TENANT IMPROVEMENT FOR DR. ILEANA R. 8 PEREZ - QUINTAIROS 6310 SUNSET DRIVE W MIAMI, FLORIDA 33143 F_ p Revisions Date bi ROBERTO SEQUEIRA REGISTRATION NO. AR-0009035 PLAN NORTH 9 6 LA td E5 z 0 R Checked By: E.G. Drawn By: Issue: 03-04-09 Date: 01-12-09 Sheet Index: WALL TYPES AND FINISH SCHEDULE Sheet Number A 60,2