09-184(3)-044FINISH SCHEDULE
ROOM. NO.
ROOM NAME I AREA
FLOOR
MATERIAL
BASE
MATERIAL
WALL
FINISH
CEILING
MATERIAL
REMARKS
NORTH
EAST
SOUTH
WEST
100
MAIN ENTRY
GL 24X24
GLB
WC
WC
WC
WC
AS SHOWN
101
LOBBY / WAITING AREA
GL 24X24
GLB
WC
WC
WC
WC
ASC
102
RECEPTION AREA
GL 24X24
GLB
WC
WC
AP
WC
103
NOT USED
104
A/C. #2 CLOSET
CPT
VN B
PT
PT
PT
PT
DW
105
CLOSET
CPT
VN B
PT
PT
PT
PT
DW
106
MULTI -PURPOSE RM.
CPT
VN B
PT
PT
PT
PT
ASC
107
I.T. CLOSET
VN
VN B
PT
PT
PT
PT
DW
108
DR. OFFICE #1
CPT
VN B
PT
PT
PT
PT
ASC
109
OFFICE MANAGER
CPT
VN B
PT
PT
PT
PT
ASC
110
HALLWAY
GL 24X24
GLB
WC
WC
WC
WC
DW
ill
112
FACIAL ROOM #1
FACIAL ROOM #2
VN
VN
VN B
VN B
WC/MO
WC/MO
WC
WC
WC
WC
WC
WC
ASC
ASC
113
EXAM-8
VN
VN B
WC
WC
WC/Mo
WC
ASC
114
DR. OFFICE NOA
CPT
VN B
PT
PT
PT
PT
ASC
115
DR. OFFICE NO.2
CPT
VN B
PT
PT
PT
PT
ASC
116
A/C. #3
VN
VN B
PT
PT
PT
PT
ASC
117
V.I.P. WAITING
VN
VN B
PT/MO
PT
PT
PT
ASC
118
WORK AREA
GL 24X24
GLB
WC
WC
WC
WC
ASC
119
EXIST. TOILET
GL 24X24
GLB
PT
PT
MID
PT
DW
120
EXIST, TOILET
GL 24X24
GLB
MID
PT
PT
PT
DW
121
HALLWAY
GL 24X24
GLB
WC
WC
WC
WC
ASC
122
FACIAL
VN
VN B
WC1M0
WC
WC
WC
ASC
123
FACIAL
VN
VN B
WC
WC
WC/Mo
WC
ASC
124
NOT USED
125
NOT USED
126
CONSULTATION
GL 24X24/MO
GLB
PT
PT
PT
PT
127
DR. ASSISTANTS
CPT
VN B
PT
PT
PT
PT
ASC
128
HALLWAY
GL 24X24
GLB
WC
WC
WC
WC
DW
129
CLO.
GL 24X24
GLB
PT
PT
PT
PT
DW
130
HALLWAY
GL 24X24
GLB
WC
WC
WC
WC
ASC
131
EXAM-2
VN
VN B
WC
WC/MO
WC
WC
ASC
132
EXAM-3
VN
VN B
WC/Mo
WC
WC
WC
ASC
133
REMOLDELED MEN'S RE!,STROOM
GL 24X24
GLB
PT
PT
Mo
PT
DW
134
REMOLDELED WOMEN'S RESTROOM
GL 24X24
GLB
M0
PT
PT
PT
DW
135
LAB
VN
VN B
PT
PT
PT/MO
PT
DW
136
PROCEDURE ROOM
VN
VN B
PT
PT
PT/Mo
PT
ASC
137
A/C. #1 CLO.
GL 24X24
GLB
PT
PT
PT
PT
DW
138
CLO.
GL 24X24
GLB
PT
PT
PT
PT
DW
139
EXAM-4
VN
VN B
WC
WC
WC
WC/MO
ASC
140
EXAM-5
VN
VN B
WC
WC/MO
WC
WC
ASC
141
WAITING AREA
GL 24X24
GLB
WC
WC
WC
WC
ASC
142
143
PHOTO ROOM
EXAM-1
VN
VN
VN B
VN B
PT
WC
PT
WC/MO
PT
WC
PT
WC
ASC
ASC
144
I
I W.H. I W+D. CLO.
GL 24X24
I
GLB
I
PT
I
PT
I
PT
i
PT
I
DW
I I
FINISH I F(;FNn GENERAL NOTES FOR WALL TYPES
ALL INTERIOR FINISHES SHALL MEET
I. STUDS GAUGES SHALL BE AS FOLLOWS:
THE FOLLOWING REQUIREMENTS:
1. ALL WALLS AND CEILING FINISHES TO
A. ALL STUDS EXCEPT 1-5/8') 10-0- HT. OR LESS = 25GA.
BE CLASS: A
B. ALL STUDS EXCEEDING 1V-O'HT. = 20GA.
C. ALL STUDS I -518"= 20CA
2. ALL INTERIOR FINISHES IN CORRIDORS
D. 18GA. METAL STUD FRAMING@ ALL WALLS SUPPORTING CABINETRY.
SHOULD BE CLASS: A
E. ALL STUDS@ WALLS WHERE CABINETS ARE TO BE AFFIXED MUST BE 18GA. ORB R
3. ALL GYPSUM WAALBOARD PARTITIONS,
CEILINGS AND SOFFITS SHALL BE 5/8"
2. TILE BACKER BOARD IS TO BE USED AT ALL HORIZONTAL BATHROOM SURFACES. SUCH AS TUB DECKS, SHOWER SEAT, NICHES
TYPEW.
AND SILLS FOR STONE, CERAMIC OR MARBLE APPLICATION, ADHERENCE TO RECOMMENDATIONS CONCERNING SEALING EXPOSED
EDGES, PAINTING, TILE ADHESION, FRAMING AND INSTALLATION IS NECESSARY FOR SATISFACTORY PERFORMANCE
4. FOR CEILING HEIGHTS, REFER TO
REFLECTED CEILING PLANS (SHEETS
3. MOISTURE RESISTANT BOARD IS TO BE USED AT ALL AREAS EXPOSED TO MOISTURE AND ALL PIPE PENETRATIONS.
A-4.01, A-4.02, & A-4.03).
4. TILE BACKER BOARD SHALL BE USED AT STONE / CERAMIC / MARBLE APPLICATIONS,
5. ALL GYPSUM BOARD CEILINGS SHALL
BE PAINTED (TYP.).
5. FIRE RATED BOARD SHALL BE USED AT ALL FIRE RATED LOCATIONS ANDS BE CONTINUOS TO UNDERSIDE OF SLAB. ALL
PENETRATIONS SHALL HAVE PROPER UL RATED FIRE SAFING PER ASTM E814 AND UL1479 TEST CRITERIA.
6. ABBREVIATIONS:
6. USE 6" METAL STUDS AT 24' D.C. AT WALLS WHERE ELECTRICAL PANELS AND PLUMBING LINES WILL BE INSTALLED.
GL 24X24 = GLASS TILES
GL B = GLASS BASEBOARDS
7. REQUIRED BRACING FOR STUDS SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR INSTALLING THEM.
WC = WALLCOVERING
CPT = CARPET
8. COORDINATE REQUIRED BLOCKING FOR ALL FUTURE GRAB BARS AT HANDICAP ADAPTABLE BATHROOMS.
VN = VINYL TILES
•VN B = VINYL BASEBOARDS
9. FOR VERTICAL AND HORIZONTAL REINFORCEMENT OF CONCRETE I MASONRY WALL IS) REFER TO STRUCTURAL DRAWINGS AND
PT = PAINT
PROJECT MANUAL SPECIFICATIONS.
MID = MOSAIC GLASS
ASC = ACCUSTICAL CEILING
10. ALL CMU. BLOCK TYPES TO BE MINIMUM 2 HP, RATED (TYPICAL),
DW = DRYWALL
DW = CHANGE IN ARCH PLAN
11. INSULATION TYPES (REFER TO ENERGY CALCULATIONS FOR REQUIRED RNALUES.
A. R-1 I MINIMUM INSULATION @ ALL EXTERIOR WALLS.
C. 1"EXTRUDED POLYISOCY ANURATE AT ROOF LEVEL FURRED CONCRETE CEILINGS,
If f
CEILING FINISH MAY OCCUFL REFER TO
CEILING FINISH MAY OCCUR. REFM TO REFLECTED CEILING PLANS AND DETAILS. CEIM FINISH MAY OCCUFL REFER TO
REFLECTED CUM PLANS AND DETAILS. REFLECTED CEILING PLANS AND DETAILS.
77.
17 GYPSUM BOARD. REFER TO (1) LAYER 17 GYPSUM BOARD 17 GYPSUM BOARD. REFER
GENERAL NOTE XAND X, TO GENERAL NOTE XAND )L
1 5F STEEL STUD AT 24' D.C.
NEW STUCOD FINISH B-FOLD INSULATION. REFER
TO MATCH EXISTING. TO GENERAL NOTE X
HORIZONTAL BRACING AS REQUIRED,
REFM TO NOTE X
REFER
(1) LAYER ST GYPSUM WALLBOARD OR VENEER BASE APPUED AT RIGHT ANGLES OR 8CAtU BLOCK TO
PARALLEL TO EACH SIDE OF 3 Sr METAL STUDS 24* O.G. WITH f TYPE S DRYWALL SCREWS GOUANOTE XANDX
r0.11TOVERTICAL EDGES AND 17 O.C. TO TOP AND BOTTOM RUNNERS AND REFER TO RR PLAN D(TER)OR INTERIOR
INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24" D.C. EACH
SIDE ANDOPPOSITESIDES.
1 W METAL STUD AT 24'0.C.
3 5T METAL STUD AT 24'D.C. REFER TO GENERAL NOTE X
REFM TO GENERAL NOTES,
FLUB TO STRUCTURAL
FLOOR FINISH MAX OCCUR.
DRAWINGS FOR 3W
CONTINUOUS SEALANT. REFER TO FINISH SCHEDULE
DOTRIOR DROP AT SLAB.
CONTINUOUS SEALANT
FLOOR SLAB. FLOOR SLAB FLOOR SLAB
Z_ FLOOR FINISH MAY =IF. :a--- FLOOR FINISH MAY OCCUR. HORIZONTAL CONTROL
REFER TO FINISH SCHEDULE REFERTOFINISH SCHEDULE
JOINT MAY OCCUR.
CONTINUOUS SEALANT
TYPICAL METAL STUD PARTITION 11 Q TYPICAL METAL STUD PARTITION 8aa TYPICAL METAL STUD PARTITION
-Heerjy In6n, aknal 1'nC_. X:
811 Ponce De Leon Blvd. 6 W
-Coral -Ggbles, FL 331' 3A
'E
L:
'FAX- (=,,'44C-23.'4
http://www.s-garchitects.com 6
W
AA 0002293
EB 0005176 ii
Project Number
0723701 En
z
0
Consultants
el
G.V. PIREZ iE
STRUCTURAL ENGINEERS
7315 S.W. 87th AV
MIAMI, FL 33173
TEL- 305-412-2200
Consultants 0.
DESIGN ONE
CONSULTING ENGINEERS CL
809 S.W. 8 STREET, No. 200
MIAMI, FL 33130
TEL- 305-860-0384
OFFICE TENANT
IMPROVEMENT FOR
DR. ILEANA R. 8
PEREZ - QUINTAIROS
6310 SUNSET DRIVE W
MIAMI, FLORIDA 33143 F_
p
Revisions Date
bi
ROBERTO SEQUEIRA
REGISTRATION NO. AR-0009035
PLAN NORTH
9
6
LA
td
E5
z
0
R
Checked By:
E.G.
Drawn By:
Issue:
03-04-09
Date: 01-12-09
Sheet Index:
WALL TYPES
AND FINISH
SCHEDULE
Sheet Number
A 60,2