Loading...
08-357-014A/C RATING: IOK A/C 120/2461 PHASE 3 WIRE 200 AMP MOUNT: FLUSH PANEL A CIRCUIT LOCATION BREAKER POLE `VIRE CONDUIT 1 DISHWASHER 20 1 12 1/2 2 WASHER 20 1 12 1/2 3 DISPOSAL 20 1 12 1/2 4 BATH RECEPT 20 1 12 1/2 5 BATH RECEPT 20 1 12 1/2 6 SMALL APPL 20 1 12 1/2 7 SAIALL APPL 20 1 12 1/2 8 AHU 1 40 2 8 3/4 9 AHU 2 40 1 8 1/2 10 AHU 1 40 2 8 3/4 11 AIIU 2 40 1 8 1/2 12 CU 1 30 2 10 3/4 13 CU 2 30 1 10 1/2 14 CU 1 30 2 10 3/4 15 CU 2 30 1 10 1/2 17 OVEN 40 1 8 1/2 18 DRYER 30 1 10 1/2 19 OVEN 40 1 8 1/2 20 DRYER 30 1 10 1/2 21 WATER HEATER 40 1 8 1/2 22 DRYER 30 1 10 1/2 23 WATER HEATER 40 1 8 1/2 24 LIGHTS 15 1 14 1/2 25 LIGHTS 15 1 14 1/2 26 LIGHTS 15 1 14 1/2 27 LIGHTS 15 1 14 1/2 28 LIGHTS 15 1 14 1/2 29 LIGHTS 15 1 14 1/2 30 LIGHTS 15 1 14 1/2 31 RECEPT 15 1 14 1/2 32 RECEPT 15 1 14 1/2 33 RECEPT 15 1 14 1/2 34 RECEPT 15 1 14 1/2 35 RECEPT 15 1 14 1/2 36 RECEPT 15 1 14 1/2 37 RECEPT 15 1 14 1/2 ELECTRICAL, GENERAL NOTES A. GENERAL PROVISION: 1. GENERAL: PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM. 2. CODES AND STANDARDS: CONFORM TO THE REQUIREMENT OF ALL GOVERNING CODES AND STANDARDS, INCLUDING NATIONAL ELECTRICAL CODE. 3. VISIT THE SITE OF PROPOSED PROJECT TO BECOME FAMIUAR WITH THE WORK CONDITIONS AND NATURE OF WORK, PRIOR TO SUBMITTING BIDS. NOTIFY ENGINEER OF DISCREPANCIES OR OMISSIONS FOR INTERPRETATION OR DECISION AND SUCH DECISION SHALL BE FINAL. B. BASIC MATERIALS AND METHODS: CONDUIT — INTERIOR WORK: CONCEALED ELECTRICAL METALLIC TUBING; EXTERIOR BELOW GRADE: SCHEDULE 40 PVC; EXTERIOR EXPOSED: SCHEDULE 40 RGS. OUTLET BOXES — 4" x 4" STEEL WITH PLASTER RINGS SIZED IN ACCORDANCE WITH N.E.C. FOR CONCEALED INTERIOR WIRING, CAST FERROUS OUTLET BOXES WITH INTEGRAL HUBS FOR EXPOSED AND EXTERIOR DEVICES. WIRE — COPPER, THHN/THWN DUAL RATED. WIRING DEVICES — SPECIFICATION GRADE DEVICES AND PLATES WITH IVORY FINISH, EXCEPT MATCH PANELED WALL WITH DEVICES AND PLATES OF SIMILAR COLOR. a. RECEPTACLES: 20 AMPS, 120V, 2 POLE, 3 WIRE, GROUNDING TYPE OR ISOLATED GROUND TYPE AS SHOWN ON DRAWINGS. b. SWITCHES: 20 AMPS C. LIGHTING FIXTURES: 1. FURNISH LIGHTING FIXTURES AS REQUIRED BY OWNER AND AS INDICATED ON DRAWINGS. FURNISH ALL NECESSARY MOUNTING HARDWARE AND LAMPS. 2. ALL RECESSED INCANDESCENT FIXTURES SHALL SATISFY THE REQUIREMENTS OF N.E.C. 410-65(2). D. PANELS: 1. ALL PANELS SHALL BE U.L. RATED AND OF THE SAME MANUFACTURER. PROVIDE SIZE AND TYPE AS INDICATED ON DRAWINGS. PANELS SHALL HAVE FULL SIZE NEUTRAL BUS AND 1/2 SIZE GROUND BUS. E. GROUNDING: 1. PROVIDE CONTINUOUS GROUNDING SYSTEM IN ACCORDANCE WITH N.E.C. SECTION 250, AND AS INDICATED. PROVIDE GROUND CONDUCTOR IN ALL RACEWAYS. F. IF, THROUGH ERRORS OR OMISSIONS, THE INTENT OF ARCHITECT/ENGINEER WITH REGARD TO ANY DETAIL IS NOT CLEAR, OR IS CAPABLE OF MORE THAN ONE INTERPRETATION, SUCH MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS, AND THE ARCHITECT/ENGINEER SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. OTHERWISE, NO EXTRA CHARGE WILL BE ALLOWED FOR THE WORK OR MATERIAL WHICH THE ARCHITECT/ENGINEER WILL REQUIRE, PROVIDED Ta,AT IT COMES WITHIN A REASONABLE INTERPRETATION OF THE DRAWINGS AND SPECIFICATIONS. G. THE PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE PERFORMED, ALL ITEMS NOT SPECIFICALLY MENTIONED OR SHOWN, BUT NECESSARY FOR THE COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. THIS CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE MECHANICAL, ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS BEFORE SUBMITTING HIS FINAL BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED DUE TO THE CONTRACTOR'S FAILURE TO FAMILIARIZE HIMSELF WITH THE PLANS. H. INFORMATION SHOWN ON THE DRAWINGS AS TO THE LOCATION OF EXISTING UTILITIES HAS BEEN PREPARED FROM THE MOST RELIABLE DATA AVAILABLE TO THE ENGINEER. THIS INFORMATION IS NOT GUARANTEED, HOWEVER, AND IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE LOCATION, CHARACTER AND DEPTH OF EXISITNG UTILITIES. CALCULATIONS FOR PANEL GENERAL LIGHTING (3650 x 3) 10,950 APPLIANCE CIRCUIT 3,000 LAUNDRY CIRCUIT 1,500 DISPOSAL 500 RANGE 12,000 DISHWASHER 1,500 WATER HEATER 5,000 DRYER 51000 TOTAL 39,450 W 20.0 KW AT 100% 20.0 KW 29.4 KW AT 40% 11.7 KW SUBTOTAL 31.7 KW HEATING@ 65% 9.7 KW 41.4 KW PROPOSED ELECTRICAL PLAN 1/4 INCH =1 FOOT ELECTRICAL LEGEND NOTES- 1. ELECTRICAL OUTLETS OR BOXES LOCATED ON ❑PPOSITE SIDES OF RATED WALLS OR PARTITIONS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES, O LIGHTING FIXTURE, CEILING MOUNTED LIGHTING FIXTURE, WALL MOUNTED S SINGLE POLE SWITCH, MOUNTED @ 4B' AFF., TO CENTER, '3'—DENOTES 3—WAY, 'D'—DENOTES DIMMER, DUPLEX 15A, 125V, 2P, 3W, GROUNDING RECEPTACLE, MOUNT @ 18'AFF, TO CENTER, Per NEC 210.12, Arc Fault Circuit Interrupter Protection All circuits that supply outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter listed to provide protection to the existing branch circuit RISER DIAGRAM NO SCALE RELOCATE EXISTING ELECTRICAL PANEL, METER AND O GENERATOR TO THIS AREA f METER O (A a T❑ POWER COMPANY TRANSFORMER, 120/240V, 1PH, 3W SERVICE n al 0 v 7 3 META C.W.P. 0 PANEL ' RISER DIAGRAM NOTES GRADE LINE 1, 3—#3/0 KCM, THWN CU, 1-1/21C, 2, 3—#3/0 KCM, 1—#6 GND, THWN CU, 2'C, 3. 1-#4 GND, THWN Cu, 1/2'C, 4. 3/4'0 x 10' LONG COPPERCLAD GROUND ROD. 5. 6. 200' AMP, 2P, S/N, ENCLOSED CIRCUIT BREAKER, NEMA 3R ENCLOSURE, AIC=22,000 AMP, 7. NEUTRAL BUS, B. GROUND BUS, 91 #4 GROUND TO NEUTRAL BUS TIE, Y OF SOUrH h11AMl BUILDING Dr_P'r. ELELTRiCAL SECTION APPROVED BY: 'yr_u DATE: 0 ISSUE DATE: 3/16/08 PRO). NO, 080311 SCALE: AS NOTED DRAWN BY: MW CHECKED BY: JCGriffin SHEET NO.; A 8.0 AMPS AT 240 V/ 1 PHASE 172 AMPS