08-357-013SECURE WITH 1 /4"0 CONDENSING VINYL COATED STAINLESS UNIT STEEL CABLE OR EQUAL STRENGTH STRAPS. ANCHOR TO SLAB IN CRISSCROSS PATTERN ACROSS THE UNIT. POWDER DRIVEN STUDS, OR 1/2"0 EXPANSION BOLT. 3" EMBEDMENT (MIN.) 4 PER UNIT (TYPICAL). PROVIDE NEOPRENE WASHERS BETWEEN THE BOLT & CABINET. TURN ISO MODE PAD BUCKLE (TYP.) (m'•) SET AT ABOVE FLOOD LEVEL • , ;� • '.� • p : • MIN. 2" ABOVE ADJOINING GRADE. ALL EXTERIOR MOUNTED EQUIPMENT SHALL BE ANCHORED TO CONCRETE SLAB WITH MINIMUM OF 4 ANCHOR BOLTS, EACH TO WITHSTAND 500 POUNDS MINIMUM PULL OUT CAPACITY AND MEET ALL OTHER WIND LOAD REQUIREMENTS OF THE "FLORIDA BUILDING CODE - RESIDENTIAL". CONDENSING UNIT MOUNTING DETAIL N.T.S. GRAC AC UNIT CONDENSATE TRAP DETAIL N.T.S. PACKAGED SPLIT SYSTEM SCHEDULE SYSTEM DESIGNATION AHU-1 AREA SERVED SEE PLAN REFRIGERANT TYPE R-22 REFRIGERANT LINES SIZE (INCH) OD (SUCTION / LIQUID) 7/8 / 3/8 LOCATION A/C CLOSET OPERATING WEIGHT, POUNDS (MAXIMUM) 120 PHYSICAL DIMENSIONS D x W x H (INCHES) 23.5 x 24.0 x 44.5 DESIGN MANUFACTURER MODEL NO. TWE04OE13FB AIR FLOW (VARIABLE SPEED), CFM 1,280 / 600 OUTSIDE AIR, CFM/ MIN. HTG. CFM --/ 600 C TOTAL STATIC PRESSURE IN W.G. 0.5 v FAN MOTOR HP (NON -OVERLOAD) 1/2 (4.3 F.L.A.) ELECTRICAL SERVICE -VOLTS /PH/HZ 240/1/60 Qr-1 GRAND TOTAL CAPACITY, BTU/HR DESIGN/ (A.R.I. CONDITION) 32.08/ (34.4) TOTAL SENSIBLE CAPACITY, BTU/HR DESIGN/ (A.R.I. CONDITION) 26.5 / (26.4) ENTERING AIR TEMPERATURE, F DB/WB (A.R.I. CONDITION) 80 / 67 ELECTRICAL SERVICE 240/1/60 TOTAL HEATING CAPACITY, KW NOMINAL 4.80 NUMBER OF STEPS 1 AHU'S F.L.A. / MIN. CKT. AMP. / MAX. FUSE AMP. 24.3 / 30 / 30 TYPE PERMANENT THICKNESS 1" QUANTITY AND SIZE FACTORY SUPPLIED UNIT DESIGNATION CU-1 LOCATION GRADE NUMBER OF COMPRESSORS 2 CAPACITY REDUCTION YES CONDENSER FAN -TYPE /QUANTITY/HP/ No OF SPEED/FLA PROPELLER/1 / 1/3 / 2 / 2.80 MINIMUM CIRCUIT AAPACITY / MAX FUSE SIZE 18 / 30 Cn AMBIENT AIR TEMPERATURE F' OB 95 r4 OPERATING WEIGHT, POUND 400 PHYSICAL DIMENSIONS D x W x H (INCHES) 37.25 x 34.25 x 49.87 U ELECTRICAL SERVICE -VOLTS /PH/HZ 240/1/60 DESIGN MANUFACTURER MODEL NO. 2TTZ9030AI000A SEER RATING, MINIMUM 19.5 DESIGN MANUFACTURER TRANS NOTES O O O O O PROVIDE ALL KITS REQUIRED FOR SINGLE O PROVIDE PROGRAMMABLE THERMOSTAT. POINT AHU ELECTRIC CONNECTION. 4 INSTALL FLOAT SWITCH OR MOISTURE SENSOR O CIRCUIT BREAKER INTEGRAL WITH AHU. SIZE IN AUX. DRAIN CONNECTION OF AHU, TO SHUT PER MANUFACTURER'S RECOMMENDATIONS. DOWN EQUIPMENT, UPON WATER DETECTION. PROPOSED MECHANICAL PLAN 1/ INCH = 1 FOOT Q v. THERMAL VALVE W, DX SUCTION LINE REFRIGERANT LINES AIR HANDLING UNIT PITCH SHALL BE ROUTED TO ALLOW PIPING TO MOVE WITHOUT STRAIN OR STRESS AIR COOLED CONSULT MANUFACTURER FOR PIPE SIZES & ADJUST COND. UNIT �.p SUCTION LINE PITCH FOR FIELD CONDITIONS. DOUBLE PORT SIGHT GLASS VALVE REFRIGERANT PIPING DIAGRAM REFRIGERANT PIPING TO CONDENSING UNIT MAINTAIN 4' MINIMUM c� CLEARANCE ALL AROUND. R/A PLENUM WITH NON-COMBUSTIBLE AHU! OVER FLOW FRAME SUPPORT F CONNECTION CONDENSATE DRAIN CONNECTION. FLOAT SWITCH BY MECHANICAL CONTRACTOR, INTERLOCKED TO F 1 1/4' CD. SHUTDOWN UNIT UPON MOISTURE DETECTION. SEE MECHANICAL PLANS. L- 2' BELOW FLOOR (SEE PLUMBING PLANS). AHU INSTALLATION DETAIL N.T.S. RVAC NOTES 1. ALL WORK REFLECTED ON THESE DOCUMENTS ARE IN STRICT ACCORDANCE WITH 2004 EDITION OF FLORIDA BUILDING CODE- RESIDENTIAL, INCLUDING 2006 SUPPLEMENTS AND ALL APPLICABLE NFPA, ASHRAE STANDARDS & LOCAL ORDINANCES. 2. CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL CONSTRUCTION CONDITIONS. 3. CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, PERMITS, FEES, INSPECTIONS, TESTS AND INSURANCE ETC. 4. ALL SUPPLY AND RETURN AIR DUCTWORK INDICATED ON THESE DOCUMENTS SHALL BE FIBERGLASS DUCT BOARD OR FLEXIBLE INSULATED DUCT WITH CORROSION RESISTANT REINFORCING WIRE HELIX WITH R-6 INSULATING VALUE WHERE INSTALLED IN ATTIC SPACE. ALL OTHERS MAY BE FIBERGLASS DUCT BOARD WITH R-5 INSULATING VALUE. EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL UNLESS OTHERWISE INDICATED AND BE CONSTRUCTED AND INSTALLED IN STRICT ACCORDANCE WITH SMACNA STANDARDS. 5. ALL AIR DISTRIBUTION DEVICES SHALL BE AS SCHEDULED. 8. CONTRACTOR SHALL. VERIFY SPACE CONDITIONS AND DIMENSIONS AND COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO FABRICATION AND INSTAL ATION OF DUCTWORK AND ORDERING EQUIPMENT. THIS SHALL INCLUDE BUT NOT BE LIMITED TO: A) COORDINATE THE LOCATION OF THE GRILLES, LOUVERS, WALL AND ROOF OPENINGS SIZES AND LOCATIONS WITH THE ARCHITECTURAL & STRUCTURAL FEATURES AND ELEMENTS. B) COORDINATE THE LOCATION OF THE A/C EQUIPMENT AND FANS TO AVOID INTERFERENCE WITH OTHER TRADES AND THE ARCHITECTURAL AND STRUCTURAL ELEMENT'S OF THE BUILDING. 7. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. 8. CONTRACTOR SHALL MAKE NECESSARY REPAIRS IN DUCTWORK FOR AN AIR TIGHT SYSTEM. 9. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATION OF FIRE RATED BARRIERS PER LOCAL CODES. CEILING FIRE DAMPERS SHALL BE RADIATION TYPE, U.L LABEL 10. ALL EXHAUST FAN OUTLETS SHALL MEET ALL SEPARATION REQUIREMENTS AS SET FORTH IN FLORIDA BUILDING CODE. 11 WHERE DUCTS PASS THROUGH BUILDING STRUCTURE THE OPENING SHALL BE 1' LARGER IN ALL DIRECTIONS. 12. REFRIGERANT PIPING SHALL BE TYPE 'L' COPPER. INSULATE SUCTION LINE WITH 3/4' THICK FOAMED PLASTIC INSULATION, 25/50 FLAME SPREAD AND SMOKE DEVELOPED RATING (MAXIMUM) (R-4). 13. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR PERIOD OF ONE YEAR FROM DAIS OF ACCEPTANCE. COMPRESSORS SHALL CARRY 5 YEAR FACTORY WARRANTY. 14. ALL OTHER ELEMENTS / COMPONENTS AND PARTS NOT SPECIFICALLY NOTED HEREIN AND IS REQUIRED AS STANDARD PRACTICE FOR A COMPLETE WORKING SYSTEM SHALL BE PROVIDED AND INSTALLED AT NO ADDITIONAL COST TO OWNER. 15. ALL ROOF MOUNTED EQUIPMENT AND ACCESSORIES, ALONG WITH EQUIPMENT LOCATED AT GRADE, SHALL BE SECURED TO WITHSTAND THE FLORIDA BUILDING CODE 1619.2 WIND LOAD REQUIREMENTS. 16. ALL WORK SHALL BE PERFORMED IN FIRST CLASS WORKMANLIKE MANNER. 17. INSTALL ALL EQUIPMENT AS PER MANUFACTURER'S RECOMMENDATIONS. 18. BALANCE EACH AIR SYSTEM TO DELIVER QUANTITIES INDICATED. SUBMIT AIR BALANCE TEST RESULTS, PRIOR TO FINAL ACCEPTANCE BY OWNER. 19. BUILDING ENVELOP INSULATION: o) ROOF R-30 b WALLS R-4.1 c) PARTITION - NONE 20. INSTALLATION AND TERMINATION OF ALL CONTROL WIRING IS THE RESPONSIBILITY OF MECHANICAL CONTRACTOR. COORDINATE ALL REQUIRED J-BOXES AND CONDUITS WITH THE ELECTRICAL CONTRACTOR. 21. CONDENSATE DRAIN PIPING: SEE PLUMBING PLANS. PVC SHALL. NOT BE INSTALLED IN RETURN AIR PLENUM. Project: O Q E - O O �w o n� Q � o0 Architect: . •1 •� f r f � e LA M M r u- w Q u Lu t�7 N r J° a � N �M uJ Qomc�i�- Ln N In 1�0 Q QMLn2 IN MY PROFESSIONAL JUDGEMENT AND TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND THE SPECIFICATIONS COMPLY WITH THE FLORIDA BUILDING CODE AND ALL APPLICABLE CODES, COPYRIGHT02007 James Griffin, Architect ALL RIGHTS RESERVED. THESE DRAWINGS AND THE SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF JG . WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT. THEY ARE NOT TO BE USED IN ANY MANNER ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH THE APPROPRIATE COMPENSATION TO JG. REPRODUCTIONS OF SPECIFICATIONS WITHOUT THE WRITTEN CONSENT OF JG IS PROHIBITED. DRAWING TITLE PROPOSED MECHANICAL PLAN ISSUE DATE: 3/16/08 PROD. NO. 080311 SCALE: AS NOTED DRAWN BY: MW CHECKED BY: JCGriffin SHEET N0.' A /.0