Loading...
05-766-020301/0 cu. < 1.6 GRD. DOUBLE LUGS 150 METER 300 A 150 150 150 RATING NAMP.M 150 AMP. DI 22,000 A.I.G . 10,000 A-I.C. L3 • I/O Cu. IN Ili7' CONDUIT • 2 CU. THWN GRD IN 11/Z' CONDUIT j/`, C1LP. 2' RGC TO - POWER COMPANY TRANSFER PAD ' TO STRUCTURAL FOUNDATION REINF. AS PER NF.C. 250-61C • 5 FOUNDATION REBAR MIN. 20 FT. LONG HOUSE CONCRETE FOUNDATION ELECTRICAL RiSER NTS SNORT CiRCUIT AMPS CALCULATIONS SHORT CIRCUIT AMPS AT TRANSFORMER = 26,194 (FPL) SERVICE DROPS LENGTH 20 FT. MINIMUM 4/0 ALUMINUM C = 9090 2XLX1- 2 X 20 X 26,194= L-L = C X VL-L 9090 X 240 0.72 2 X L X I X1 X1.5_ 2X20X26,194X1.5 L-L C X VL-L 9090 X 240 = 0.72 M L-L = t + L-L - 1 + 0.48 1.48 = 0.68 M L-N = 1 + L-N - 1 .72 = 0.58 L_L = 26194 X 0.68 = 17,812 AMPS I L-L = 26194 X 0.58 = 15193 INTERRUPTING SHORT CIRCUIT AMPS AT METER BANK = 17812 AMPS USE 22,000 A.I.C. MINIMUM FPL MAXIMUM AT METER = USE 22,000 AI.C. MINIMUM AVAILABLE: (SEE CALCULATIONS ABOVE) MAIN 5US : 150 AMP fit" SERVICE : 120 / 240 SINGLE PHASE. 3 WIRE /� I II II NEUTRAL 150 AMP MOUNTING : SURFACE PANEL MAINS : 150 AMP POLES : 30 A.I.G.: 10.000 DEMAND K.V.A. No DEMAND K.V14. TRIP- POLE CON- DUIT WIRE SIZE DESCRIPTION CIR " CIR • DESCRIPTION WIRE SIZE CON- DUIT TRIP- POLE NO DEM'Ag K.V.A. DWAND Q.V.A. 120 15-1 1/2, 014/2 GUEST BATH 1 2 BATH GFCI. 012/2 i/2' 20-1 I -ISO IZm 15-1 1/2, FUTURE POOL LTG. 3 4 ALARM OUTLET 012/2 1/2' 20-1 I ' 120 20-1 1/2' $12/2 HIDRO-TUB GFC1. 5 fo MICROWAVE 012/2 1/2' Ism 20-1 1/2' PJPJ S LANCOCAFE LT& 1 8 CENTRAL VACCUM 012-2 1/2' 20-1 '�, 12 1.10 20-1 1/2' 012/2 GARAGE DR OPENER 9 10 "RAW DR OPI=NER 012/2 1/2' 20-1 15m 20-i 1/2' 012/2 BATH GFCI. Il 12 WATER HEATER •I0/2 3/4' 30-2 150 20-2 1/2' FUTURE POOL Putip 13 14 15 ib FUTURE SPR• PUMP 1/2, 20-2 .�++ I 5.00 30-2 3/4' 010/2 DRYER 1'I 18 1130 RANGE 06/3 I' 50-2 :- • lr IZm 20-1 1/2' 012/2 WASHER 1 22 L50 20-1 1/2' 012/2 EXT. RECEPT. GFCI. 23 24 BATH GFCI 012/2 1/2' 20-1 1 1.50 SPACE 25 26 SPACE 21 28 29 30 16.9m NOTE: MAIN BREAKER 4 LOAD CENTER BREAKER SHALL NAVE A SERIES CONNECTED INTERRUPTING RATINGS OF- 22,000 SYMMETRICAL AMPS. ELECTRICAL NOTES I. OUTSIDE RECEPTACLES, RECEPTACLES AT BATH, GARAGE AND KITCHEN SHALL COMPLY WITH THE STANDARD OF THE N.E.C. 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM LIGHTING CIRCUIT INTERCONNECTED AND WITH BATTERY BACK-UP. CONNECT SMOKE DETECTORS AHEAD OF SWITCHES, 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER SERVICE ENTRANCE LOCATION 4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. 5. ALL 'X BOXES SHALL COMPLY WITH N.E.C. 310-11A. 6. MAXIMUM NUMBER OF OUTLETS PER CIRCUIT SHALL COMPLY WITH F.B.C. 1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE WA51TAL AREAS. S. NO APPLIANCES OR APPLIANCE OUTLET SHALL BE INSTALLED BELOW BASE FLOOD LEVEL. 9. A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. 10, MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION. 2040 11. ELECTRICAL CONTRACTOR WILL CONFER WITH FLORIDA POWER a LIGHT TO LOCATE THE ACCESS ELECTRIC METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. PANEL 12. ALL RANGES AND DRYERS SHALL BE WIRED WITH 4 WIRE CONDUCTORS, WITH 4 WIRE CORDS, 4 WIRE ATTACHMENT RECEPTACLES AND ISOLATE NEVT• FROM FRAME. N.E.C. 250-60 13. PROVIDE ARC -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 15 AND 20 AMPS 125 VOLT BEDROOM BRANCH CIRCUIT RECEPTACLES OUTLETS. NEC 210-12 14. PROVIDE RECEPTACLE OUTLET FOR AIR HANDLER AND CONDENSING UNIT, WITHIN 25'-0' AS PER N.E.C. 210-63. ELECTRICAL LEGEND $ SWITCH , b PUSH-BUTTON $g THREE WAY SWITCH TV E] TELEVISION ANTENNA qp DUPLEX RECEPTACLE T TELEPHONE JACK POLED DUPLEX RECEPTACLE ® SMOKE DETECTOR W/ SD BATTERY BACKUP QUADPLEX RECEPTACLE [3J DISCONNECT SWITCH q) SINGLE RECEPTACLE p ELECTRICAL PANEL It SPECIAL RECEPTACLE 3:1 ELECTRIC METER 0 CEILING MOUNTED FIXTURE WP WEATHER PROOF 4 WALL MOUNTED FIXTURE GPI GROUND FAULTED INTERRUPTER ❑ RECESSED CEILING FIXTURE HB -f - HOSE BIB EXHAUST FAN PC O PULL CHAIN DOORBELL O JUNCTION BOX O FLORESCENT LIGHT QQ FLOODLIGHT FIXTURE CENTRAL VACUUM CEILING FAN ® NUTONE LIGHT ROMEX 15 AN ACCEPTABLE ALTERNATIVE. t 111511 FAEL1 `( 4 , r 4.4 1 TOTAL CONNECTED LOAD = 16.'a0+ 26.30 ;/ 43.2 tl'ru FIRST 10 KW a 100% r 10.0 KW MAIN BUS : 150 AMP SERVICE : 120 / 240 SINGLE PHASE. 3 WIRE I II II NEUTRAL 150 AMP .• MOUNTING : SURFACE FANELI � MAINS : 150 AMP a POLES 40 A.I.G.: 10.000 = o' DEPJAND K.V.A. No DEMAND K.V.A. TRIP- POLE CON- DUIT WIRE SIZE DESCRIPTION CIR • CIR. • DESCRIPTION WIRE SIZE CON- DUIT TRIP- POLE NO DEMAND I K.V.A. DEMAND- K.V.A. "' Obs 2 15-1 1/2' 014 GARAGE 1 2 BED • 4 AF:C•I. 014 1/2' 15-1 2 0B9 A 15-1 15-1 15-1 1/2' 1/2' I/2' 014 014 014 FAMILY ROOM ENTRY/ HALLWAY-AFCI KITCHEN t FAMILY LTGS 3 5 1 4 6 8 GREAT ROOM DEN AF.G,I. BED • 3 AF.C•I. 014 014 014 1/2' 1/2' 1/2, I5-1 15-1 15-1 15-1 1/2' 014 BED • 2 AP=. 9 i0 BATH • 2AlUJr- 014 1/2' 15-1 -- m.89 2 15-1 1/2' 014 MASTER 5ED. AAC.i. 11 12 KA6TER OW 4 BATH AFO•L 014 1/2, 15-1 2 m89 ISO 20-1 1/2' 012 SMALL APPLIANCES 13 14 SMALL APPLIANCES 012 1/2, 20-1 115m ISO 20-1 1/2' 012 SMALL APPLIANCES 15 1(o LAUNDRY OUTLET 012 1/2, 20-1 150 1 1.50 20-1 1/2' 012 DISdUASHER 11 18 REFRKWRATOR 012 1/2' 20-1 IZm 1�00 20-I 1 1/2' 012 DISPOSAL IS 20 AI-W. • 1 06/2 3/4' 60-2 9B0 ---- (53) 35-2 3/4' 010 A/c COMP. • I 21 22 23 24 AJau• • 2 %/2 3/4' 60-2 sw ---- (6.0) 40-2 3/4' 08 A/C COMP •2 25 26 21 28 H►-HATS 4/2 1/2' 15-1 1.00 SPACE 29 30 MASTER OR-wcA4A1L-AFL!• 014 1/2, 15-I 2 089 31 32 SPACE 33 34 35 36 31 Be 3S 4m 1084 19bm 1054 4 REMAINDER a 4051. 028 KW AN II J� II EL TOTAL LOAD (KW) 2328 KW I Ql SUBFEED C.U. FROM A.H.U. KW. /240 (■ AMPS) 91.00 AMPS, QQ CALC. a .003 KW. SQ. FT. X 3,511 SQFT = 10.13 KW. -� TOTAL CONNECTED LOAD = 10.84 + 1054 = 21.38 KW. ti.•. FIRST 10 KW e 100% = 10.00 KW ' REMAINDER e 40% = 4.55 KW 11A IIA ,�+� TO FUTURE LANDSCAPE I HEATER KW 0 BLOWER) 10.40 KW $ A.H.U. 02 e 100% = 10.40 KW (HEATER KW + BLOWER) TO FUT6RE POOL LIGHT \K�T���OAD MPS) 4129 AMPS AN IIA ,..•� I � . .. . 1 11A LIGHT -------- --------- -------- \: - - - - - - -- - - - - - - - - --------- 4A �13A� 3A O 3A IlAr �•A�,, \-- / le COVERED TERRACE BREAKFAST SA MASTER BEDR0004 / - r•„ 28A OUTLET FOR \ FUTURE POOL TA TA TA g' IIA \. 3A 1`. SPRRINKLER�PUMF ilA IIA �c I -� 2�3pB 16,18$ l I SD ,s;'• �= II GFCI 13A TA 3 m ( A --_- � 14 � I 0 I A 7"13 3/IN �+ 4 3 TA \ FAMILY ROOM 12A GFCI 3 3 4A 3A iA i FAN { � / GFCI >�w, ISP. O 1 3m I IiA / \ Iz R3 14A 1�,19 28A / A IGHT \ / 28A 28A I 3A I 1 2 A 12A tJJ i2A \ O 3A 3m I UEST I I J ATHGREAT ROOM I 14 / 3A 12A M15AT _vP � �"'� I 1 � ® 13 C7Al30A I I SD 30A4A I // 2A---------- IIA 4A 1ITCi-iN 211A KOA% 72ep- BA 2BA f M.LC. 1�H/COMP T' 2A FROM 12A. �y�.GFCt - CEILING 1•'a' 2,q/0A _ _- - p _ v 13A 14A \ SD ® 1 IIA ' 1 IGHT 01 0,22 / ' 2A 12A I 11.5 I SD 5A I .l \ / y / 4A 1 1 FAN GFI I 5A -9' I of `'I.C. VP i2 4'} 1 1 ALARM i6,A $GIF I G. ! ;`� 2A 25,21A CI r /4) cv 77 x F +....r M . 6A1 PANEL A '�` PRE IRED FOR 9A g,q iC. ® / 1 // �, PANEL B CLG. FAN sb �� 1 e� >►, / N IA BEDRC�M 4 IA BEDROOM 2 I % : sa T 3 2A ^ 5A DEN / `.FOYER /-'�;•ti=�r;,4UND 119,1g':.,, 2A L21j� PREWIIRED FOR CLG. FAN 5A 9A 9•A 6A �;'ea' S i I I �,.rr > .` GFCf CENTRAL 9,A _ ��6A 5A `�� PA I I , �� 3 23B 4 �'. VACCUM WP PB LIGHT I C. PREWIRED FO \ *,5A 15A ti� 1t, 1A - @ 72 �; \ 6.A CLG. FAN "� '� AKP y ,�,; rya. I I \ D I N i NG A. F.F. IA 23.8 \ FANIX �9 9A .M \ IBA \. I► LiGHT' 9A ®9 SD I ► �' 1 1A 9A u 1 6A t 15A qp I A / / 8A LG. + 12,14.8 1A GARAGE \ IA S; - JU f' 2405 GFCI BATH 8A / 8A iOA LIGHT./FAN /, „ I CO RED ENTR x i I X - - - - - - 9.B i GARAGE OUTLET DOOR; 88A11111.- 1 1 5A I I I I GARAGE DOOR I 1 PREwIRED FORS;#, I I I I 1 I 1 HB CLG. FAN > I I y Y I I i DISC -A SA BEDROOM 3 6A ---mA- 1 IOA I ------ i I DISC-B 1 ELEC. METER 23.5 Lill, ELECTRICAL 11...,"".tl g_ -/��' 1/411 - RT- ASION BY fe, V1 r ^rw O� w 00 s• U_ it 0 , C 0Qu+ M 04 LL Zci w c 0 0 O,,N^^ •. w): cr) cd i E cd Q UNff DATE 5 - ;•y- oS r. SCALE AS SHOWN DRAWN JOB SHEET SHEET OF A, ' ,Q +' REG. No.10,154