05-766-01712 W, 2' Y 29 FIXTURE UNITS TOTAL PLUMBING NOTES 1.0 GENERAL 1.1 PROVIDE (FURNISH AND INSTALL) ALL NECESSARY MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND HERE IN SPECIFIED. INSTALL IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE AND LOCAL ORDINANCES. 1.2 SCOPE OF WORK: PROVIDE THE FOLLOWING COMPLETE SYSTEMS: A. SANITARY COLLECTION B. DOMESTIC HOT AND COLD WATER C. AIR CONDITIONING CONDENSATE. 1.3 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED, 1.4 VERIFY AT JOB SITE SPACE CONDITIONS, DIMENSIONS WITH PIPE, FIXTURES, AND EQUIPMENT 51ZE PRIOR TO 2.0 MATERIALS 2.1 PROVIDE SHUT-OFF VALVES FOR EACH FIXTURE AND AIR CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM. 2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM PIPING AND SLABS TO PREVENT CORROSION. 2.3 PIPING 2.3.1 DOMESTIC HOT AND COLD WATER: COPPER TUBING TYPE "K' OR "L' WITH SOLDER JOINTS. WOG BRONZE VALVES 125 P.S.I. MIN. PROVIDE PRE -MOLDED FIBERGLASS INSULATION FOR HOT WATER LINES. NOTES: I. ANTI -SCALD VALVES FOR TUB/SHOWER REQUIRED 2. MINIMUM SIZE OF ALL PLUMBING DRAIN LINE BELOW FLOOR 2 INCH FLUM51NG FLAN 1/411 NOTE: 2' DRAIN a LESS 6 114" PER FOOT SLOPE 3" DRAIN a HIGHER ,0 l/s" PER FOOT SLOPE REVISION BY W A� ~ A 0 a w �W �cf) 0 0 LL 08 a o H r� d z .fl 8 clsw 0 (j) 5 UL. �1 Q U . .n - a �i N L Nrr DATE 5'-a4•05 SCALE AS SHOWN DRAWN JOB SHEET p-i SHEET , ,QF M. J. CHID i XNC14TECT REO. No. 10,154