05-766-016AIR CONDITIONING GENERAL NOTE6 1. ALL AHU TO HAVE COND. DRAIN FLOW SWITCH 2. ALL EXHAUST DUCT SHALL BE CONSTRUCTED OF SHEET METAL, TERMINATE OUTSIDE THE BUILDING, AND BE EQUIPPED WITH A BACKDRAFT DAMPER (T-FIN ALLOWED) 3. DUCTS FROM TOILET ROOMS SHALL DISCHARGE TO THE OUTSIDE OF THE BUILDING, SHALL BE TERMINATED NOT LESS THAN 6 INCHES ABOVE THE FINISH ROOF SURFACE, AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING A MESH SIZE NOT LARGER THAN 1/2 INCH. (PROVIDE GOOSE NECK OR RAIN CAP ON ROOF TERMINATIONS) 4. CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED. 5. CLOTHES DRYERS EXHAUST DUCT (OR VENTS) SHALL COMPLY WITH MANUFACTURERS INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A MINIMUM 30 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCTS JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH WOULD EXTEND INTO THE DUCT. DRYER EXHAUST DUCT SHALL COMPLY WITH CHAPTER 6, TABLE 6033 GENERAL 1. PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED INSTALL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, ASHRAE, SMACNA, NFPA, AND LOCAL ORDINANCES. 2. REFRIGERANT PIPING. SEAMLESS COPPER TYPE 'L' AND HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX. INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2' CLOSED CELL POLYETHYLENE PREMOLDEEPIPE INSULATION, WITH AN APPROVED PIPE AND SMOKE JACKET. PAINT ALL EXPOSED INSULATION WITH TWO COATS OF WHITE LATEX PAINT. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X FIRE DAMPERS) x SMOKE DAMPER(S) x FIRE RATED ENCLOSURE X FIRE RATED ROOF/FLOOR CEILING ASSEMBLY x FIRE STOPPING X SMOKE CONTROL x CEILING FANS X HEAT RECOVERY X MULTIZONE COOLING X PROGRAMMABLE THERMO X J NOTES PROVIDE P UNDERCUT AT ALL BEDROOM ENTRY DOORS AS PER FMC 601.04 ALTERNATE HURRICANE CONNECTION NOTE: ALTERNATE CONDENSING UNIT MOUNTING DETAIL AS PER DATA SUBMITTED BY PAUL WELCH INC. ON BEHALF OF RHEEM AND APPROVED BY MIAMI-DADE COUNTY BUILDING DEPARTMEINT,MECHANICAL DIVISION ON NOVEMBER 04,2003. PLEASE SEE ATTACHED SPLIT SYSTEM SCHEDULE UNIT . I 2 SERVES TOTAL CAPACITY BTU/HR 46,500 53AOO SENS CAPACITY BTU/HR 32,100 % 31,100 CFM SUPPLY 1 kOO t 2,000 HEATER KW 9.8 9B ESP -IN WG. 030 030 TEMP. AIR ENT. COIL DB/WB 80/61 80/61 C.U. FLA 14.6 14b VOLTACsE 1-60-240 1-60-240 C.U. WT. LBS DESIGN MANUFACTURER RHEEM R14EEM COIL MODEL RC5A3165 RC115A488208) F.C. MODEL NO. R3HC21JI18PO R514C24JI1SF5 C.U. MODEL NO. RAMC049JAZ RAMC060JAZ SEER 1150 11,40 LIQUID/SUCTION SIZE -IN 3/8' - 1/8' ANCHOR CONDENSING UNIT TO SLAB WITH 14' METAL STRAP 20 GA. @ MID -PT. EACH WAY W/ (4) 1 ill (W/ WASHER) REMINGTON POWER FASTENERS REFRIG. LINES ELEV. SAME AS IN. FLR. CONDENSING UNIT ---i 12" THICK CONCRETE SLAB CONDENSING UNIT TO BE SECURED TO CONIC. SLAB WITH (6) 12" (W/WASHER) REMINGTON POWER FASTENERS TO WITHST 146 M.P.H. WINDS t/ Fin. Grade r L6' min. CONDENSING UNIT MOUNTING IDETAIL NT5 NOTE: ALTERNATE ANCHOR CONN'S AS PER MANUF. SPECS., APPROVED BY BUILDING DEPARTMENT. MASTER BEDROOM / 12' X 8' CD 12' X 8' CD 250 CFM 250 CFM S' T NUTONE 696 5O CFM-3' a TO ROOF 6'X6'CD SO CFM0 IT ---� i O 4 � i 6 X0 6�CD T MASTER BATH BATH 4' 4 30 14' 6' x 6' Cr. 80 6' X 6' CO � 4'0 T 100 CFM 0 11 6'0 I I 12'a . z PVC COMO. DRAIN REF. LINES 6' Ar-j3. t 12' MIN. FROM [- ATTIC SPA \ STRUCTURE 6' 1 6' CD I II 5,9 AHU NUTONE 696 8' 0 TO CRC ' 0 1 4sx8 V pRAG — T'ST T#2 CENTERED ABOVE DOOR OL--- 12' 14XS RAG CENTEIMD ABOVE DOOR 8¢ 14' 12' X 8' CD 30' 200 CFM E— 10, X 6' CO ISO CFM 8X8 8'a 4'� LREC ❑ / 14xe / RAG X / CEN DOOR O I I I6'� 6' x 6' Co 10, x 6' CD 15 CFM ISO CFM NUTONE 696 TO RROOF 0 0 I BEDROOM 2 X 6' CD — — — 0 CFM — — COVERED TERRACE NUTONE 696 -50 CFM-3' + TO ROOF a,x16,CO 200 CFM GREAT ROOM 8'X16'CD 200 CFM FOYER 6' x 6' Co E- 100 CFM Air discharge plenum shall be mechanically attached to the AHU AS PER FBC MECH. 603.7 PLENUM 4'MIt AL ARC AHU Perforated Cap Secondary drain line to flow swicth ❑ Air Handler 12" Above Bot. of Drain Pan N Adjustable Air Handler /\ Base by Miami Tech. Inc. Drain Line Thumb screws to outside. I Wires 3/4" above slab & Flow switch "Shall shut 2 ' underground down the a/c unit to prevent overflow." Rubber mounts. AHU MOUNTING DETAIL5 NTT BREAKFAST ROOM \ / \ KITCHEN 1 ------------- I of ❑ I HOOD VENT O ❑ 1 8' 31/4' X 10' 4 24 6' TO ROOF 125 CFM 1 / / 14' 1 (a, x Irv, SIR 124 I rl71 Z50 CFM T'ST/A,T# I I I I I I I I I I I L----L-- 12, X 8' CO E- 200 CFM DINING ROOM J S'X16'SR 250 CFM PAP ZED I/ III FAMILY ROOM BEDROOM 3 ONE 696 ROGF OFm Tr8'X16,51 250 Cl" REF. LINES UP TO ATTIC SPACE 4' 0 (ID) GALV. MTL _ 1=XHAUST DUCT (30 G.A.) ✓r-- �� UP TO ROOF JACK WITH ❑ WP CAP,B.D.D. GARAGE ❑----------------❑ I I I 1 I I 1 I I i 1 I I A/C PLAN 1/411 2' PVC COND. DRAIN 6' AFj3. 4 12' MIN. FROM STRUCTURE REF. LINES UP ATTIC SPACE _REVISION BY W I� A� �A a r� �w O co!I 00 N� N O O �O CID 0 v LL rn � a 0§ 04 �a Z z U� c'n Q U 0 E t a N UW DATE 6 -O.4• 05 SCALE AS SHOWN DRAWN JOB SHEET M-1 SHEET' OF M. J. CHIU .; ARCHITFCT1 h� ry REG. No. 10,154