05-766-016AIR CONDITIONING
GENERAL NOTE6
1. ALL AHU TO HAVE COND. DRAIN FLOW SWITCH
2. ALL EXHAUST DUCT SHALL BE CONSTRUCTED OF SHEET
METAL, TERMINATE OUTSIDE THE BUILDING, AND BE
EQUIPPED WITH A BACKDRAFT DAMPER
(T-FIN ALLOWED)
3. DUCTS FROM TOILET ROOMS SHALL DISCHARGE TO THE
OUTSIDE OF THE BUILDING, SHALL BE TERMINATED NOT
LESS THAN 6 INCHES ABOVE THE FINISH ROOF SURFACE,
AND SHALL BE SCREENED WITH A CORROSION RESISTANT
MATERIAL HAVING A MESH SIZE NOT LARGER THAN 1/2 INCH.
(PROVIDE GOOSE NECK OR RAIN CAP ON ROOF
TERMINATIONS)
4. CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED.
5. CLOTHES DRYERS EXHAUST DUCT (OR VENTS) SHALL
COMPLY WITH MANUFACTURERS INSTALLATION INSTRUCTIONS,
BE CONSTRUCTED OF A MINIMUM 30 GAUGE METAL PIPE,
HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS
RUNNING IN THE DIRECTION OF THE AIR FLOW.
DUCTS JOINTS SHALL NOT BE ASSEMBLED WITH SHEET
METAL SCREWS OR OTHER FASTENERS WHICH WOULD
EXTEND INTO THE DUCT. DRYER EXHAUST DUCT SHALL
COMPLY WITH CHAPTER 6, TABLE 6033
GENERAL
1. PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS
SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED
INSTALL IN ACCORDANCE WITH THE FLORIDA
BUILDING CODE, ASHRAE, SMACNA, NFPA, AND LOCAL
ORDINANCES.
2. REFRIGERANT PIPING. SEAMLESS COPPER TYPE 'L' AND
HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH
WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDER
SHALL BE 95/5 APPLIED WITH SUITABLE FLUX.
INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2'
CLOSED CELL POLYETHYLENE PREMOLDEEPIPE
INSULATION, WITH AN APPROVED PIPE AND SMOKE
JACKET. PAINT ALL EXPOSED INSULATION WITH TWO
COATS OF WHITE LATEX PAINT.
HVAC DESIGN REQUIRES:
YES
NO
DUCT SMOKE DETECTOR
X
FIRE DAMPERS)
x
SMOKE DAMPER(S)
x
FIRE RATED ENCLOSURE
X
FIRE RATED ROOF/FLOOR
CEILING ASSEMBLY
x
FIRE STOPPING
X
SMOKE CONTROL
x
CEILING FANS
X
HEAT RECOVERY
X
MULTIZONE COOLING
X
PROGRAMMABLE THERMO
X
J
NOTES
PROVIDE P UNDERCUT AT ALL
BEDROOM ENTRY DOORS
AS PER FMC 601.04
ALTERNATE HURRICANE CONNECTION
NOTE: ALTERNATE CONDENSING UNIT MOUNTING
DETAIL AS PER DATA SUBMITTED BY PAUL
WELCH INC. ON BEHALF OF RHEEM AND
APPROVED BY MIAMI-DADE COUNTY
BUILDING DEPARTMEINT,MECHANICAL DIVISION
ON NOVEMBER 04,2003. PLEASE SEE ATTACHED
SPLIT SYSTEM SCHEDULE
UNIT .
I
2
SERVES
TOTAL CAPACITY BTU/HR
46,500
53AOO
SENS CAPACITY BTU/HR
32,100 %
31,100
CFM SUPPLY
1 kOO t
2,000
HEATER KW
9.8
9B
ESP -IN WG.
030
030
TEMP. AIR ENT. COIL DB/WB
80/61
80/61
C.U. FLA
14.6
14b
VOLTACsE
1-60-240
1-60-240
C.U. WT. LBS
DESIGN MANUFACTURER
RHEEM
R14EEM
COIL MODEL
RC5A3165
RC115A488208)
F.C. MODEL NO.
R3HC21JI18PO
R514C24JI1SF5
C.U. MODEL NO.
RAMC049JAZ
RAMC060JAZ
SEER
1150
11,40
LIQUID/SUCTION SIZE -IN
3/8' - 1/8'
ANCHOR
CONDENSING
UNIT TO SLAB
WITH 14'
METAL STRAP
20 GA. @
MID -PT. EACH
WAY W/ (4)
1 ill (W/
WASHER)
REMINGTON
POWER
FASTENERS
REFRIG.
LINES
ELEV.
SAME AS
IN. FLR.
CONDENSING
UNIT ---i
12" THICK
CONCRETE
SLAB
CONDENSING
UNIT TO BE
SECURED TO
CONIC. SLAB
WITH (6) 12"
(W/WASHER)
REMINGTON
POWER
FASTENERS
TO WITHST
146 M.P.H.
WINDS t/
Fin. Grade
r L6' min.
CONDENSING UNIT
MOUNTING IDETAIL NT5
NOTE: ALTERNATE ANCHOR CONN'S AS PER MANUF. SPECS., APPROVED BY BUILDING DEPARTMENT.
MASTER
BEDROOM
/
12' X 8' CD
12' X 8' CD
250 CFM
250 CFM
S'
T
NUTONE 696
5O CFM-3' a
TO ROOF
6'X6'CD
SO CFM0
IT
---�
i
O
4 �
i 6 X0 6�CD
T
MASTER BATH
BATH
4' 4
30
14'
6' x 6' Cr.
80
6' X 6' CO
�
4'0
T
100 CFM
0
11
6'0 I
I 12'a
.
z PVC
COMO. DRAIN
REF. LINES
6' Ar-j3. t
12' MIN. FROM
[- ATTIC SPA
\
STRUCTURE
6' 1
6' CD I
II
5,9
AHU
NUTONE 696
8' 0
TO CRC ' 0
1
4sx8 V
pRAG —
T'ST T#2
CENTERED
ABOVE
DOOR
OL---
12'
14XS
RAG
CENTEIMD
ABOVE
DOOR
8¢
14'
12' X 8'
CD
30'
200 CFM
E—
10, X 6' CO
ISO CFM
8X8
8'a
4'�
LREC
❑
/
14xe
/
RAG
X /
CEN
DOOR
O I I I6'�
6' x 6' Co 10, x 6' CD
15 CFM ISO CFM
NUTONE 696
TO RROOF 0 0 I BEDROOM 2
X 6' CD
— — — 0 CFM
— —
COVERED TERRACE
NUTONE 696
-50 CFM-3' +
TO ROOF
a,x16,CO
200 CFM
GREAT ROOM
8'X16'CD
200 CFM
FOYER
6' x 6' Co E-
100 CFM
Air discharge plenum
shall be mechanically
attached to the AHU
AS PER FBC MECH. 603.7
PLENUM
4'MIt
AL ARC
AHU
Perforated Cap
Secondary
drain line to
flow swicth ❑ Air Handler 12" Above Bot.
of Drain Pan
N Adjustable Air Handler
/\
Base by Miami Tech. Inc.
Drain Line Thumb screws
to outside. I Wires
3/4" above slab & Flow switch "Shall shut
2 ' underground down the a/c unit to
prevent overflow."
Rubber mounts.
AHU MOUNTING DETAIL5 NTT
BREAKFAST ROOM
\ / \
KITCHEN 1
-------------
I
of ❑ I
HOOD VENT O ❑ 1 8'
31/4' X 10' 4 24
6' TO ROOF
125 CFM 1 /
/ 14'
1 (a, x Irv, SIR 124
I rl71 Z50 CFM T'ST/A,T#
I I I
I I
I I I
I I I
L----L--
12, X 8' CO E-
200 CFM
DINING ROOM
J
S'X16'SR
250 CFM
PAP
ZED
I/ III
FAMILY ROOM
BEDROOM 3
ONE 696
ROGF OFm
Tr8'X16,51
250 Cl"
REF. LINES UP
TO ATTIC SPACE
4' 0 (ID) GALV. MTL _
1=XHAUST DUCT (30 G.A.) ✓r-- ��
UP TO ROOF JACK WITH ❑
WP CAP,B.D.D.
GARAGE
❑----------------❑
I
I
I
1
I
I
1
I
I
i
1
I
I
A/C PLAN 1/411
2' PVC
COND. DRAIN
6' AFj3. 4
12' MIN. FROM
STRUCTURE
REF. LINES UP
ATTIC SPACE
_REVISION
BY
W
I�
A�
�A
a
r�
�w
O
co!I
00
N�
N
O
O
�O
CID
0
v
LL
rn
� a
0§
04
�a
Z
z
U�
c'n
Q
U
0
E
t
a
N
UW
DATE 6 -O.4• 05
SCALE
AS SHOWN
DRAWN
JOB
SHEET
M-1
SHEET'
OF
M. J. CHIU .; ARCHITFCT1
h�
ry
REG. No. 10,154