Loading...
05-766-008SECURITY AND FORCED ENTRY PREVENTION BURGLARY SECURITY I. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LBS, APPLIED IN ANY MOVABLE DIRECTION 2. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT INSERT. 3. THE ACTIVE LEAF OF PAIR5 OF EXTERIOR SWING DOORS. SHALL HAVE SAME LOCKS A$ REQUIRED FOR SINGLE EXTERIOR DOORS. THE INACTIVE LEAF OF THESE PAIRS OF DOORS SHALL HAVE MULTIPLE POINT LOCKS WITH 5/5' MINIMUM THROW BOLT WITH INSERTS. 4. SLIDING GLASS DOORS SHALL BE PROVIDED WITH SLIDING DOOR DEAD BOLTS OR A BOLT OR PIN NOT REMOVABLE OR OPERABLE FROM EXTERIOR AT THE JAMB, HEAD, SILL OR AT MEETING MULLIONS, THESE DOORS SHALL BE REINFORCED IN THE STRIKE AND LOCK AREA TO MAINTAIN BOLT STRENGTH EFFECTIVENESS, IF NECESSARY, AND SUCH DOORS SHALL HAVE NO SCREWS REMOVABLE FROM OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM OUTSIDE. 5. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON -REMOVABLE PINS, AND NON -EXPOSED SCREWS. 6. JAMBS OF ALL EXTERIOR OFFSET TYPE IN -SWING DOORS BE RABBETTED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF LOCKS AND LATCHES. 1. SINGLE, SWINGING, EXTERIOR DOORS, IF WOOD SHALL BE SOLID CORE OF NOT LESS THAN 1-3/5' THICK 8. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS INSTITUTE'S STANDARD 291.1. S. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN NATIONAL STANDARDS IN5TITUTE'5 STANDARD 2S-il 10. SLIDING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MFGS. ASSOC. STANDARDS FOR FORCED ENTRY RESISTANCE, AAMA 1303.3. EXTERIOR WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. 11. FRONT AND MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS. 12. A NIGHT LATCH, DEADBOLT OR SECURITY DEVICE MAY BE USED ON EXIT DOORS FROM A DWELLING UNIT, HOTEL GUEST ROOM OR SUITE PROVIDED SUCH DEVICES ARE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT AND THE DEVICE IS MOUNTED AT A HEIGHT NOT TO EXCEED 48 INCHES (12n MM) ABOVE FINISH FLOOR, AS PER FBC (1026.4) BEAM LINTEL - BEAM STUCCO PERIMET_ BACK BEDDING NOTE: WINDOW AND SLIDING GLASS DOOR INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS SET FORTH IN THE APPROVED PRODUCT CONTROL APPROVAL. v v v VINYL WEATHER STRIPPING PERIMETER CAUL & BACK BEDDINC 1 A ► I P % SILL 1 X 3 PT. WD. BLOCKING 1 X 4 PT. FURRING u" DRYWALL 1 /4" DRYWALL CAULK 1/4"? X 2 3/4" TAPCON W/ A MIN. EMBEDMENT OF 1 1 /4" INTO CONC. SPACED 6" FROM ENDS & BALANCE @ 12" O.C. 1 X 3 PT. WD. BLOCKING CAULKING WEATHERSTRIPPING 1 /4"? X 2 3/4" TAPCON W/ A MIN. EMBEDMENT OF 1 1 /4" INTO CONC. SPACED 6" FROM ENDS & BALANCE @ 12" O.C. PERIMETER CAULKING AND BACK BEDDING STUCCO SNAP IN GLAZING BEAD ( TYPICAL ) 1/4"? X 2 3/4" LONG TAPCONS 12" O.C. & 6" FROM ENDS CAULK MARBLE SILL 8" X 8" CONC. SILL W/ 2 #5 CONT. & EXTENDED INTO FC. CBS WINDOW DETAILS N.T.S. NOTE: ANCHOR CONN'S AS PER MANUF. SPECS. _u: DOOR JAMB DETAIL GENERAL NOTES 1. FOUNDATION DESIGN IS BASED ON A SOIL BEARING CAPACITY OF 2,000 PSF. FILL SHALL BE COMPACTED TO 95% OPTIMUM DENSITY AND FIELD TESTS SHALL BE TAKEN 2. ALL REINFORCEMENT SHALLBE 60,000 PSI MINIMUM YIELD NEW BILLET STEEL IN ACCORDANCE WITH ASTM A615 GRADE 60. ALL BAR LAPS SHALL HAVE A MINIMUM OF 36 BAR DIAMETER PLACING OF REINFORCEMENT SHALL CONFORM TO THE LATEST ACI AND MANUAL OF STANDARD PRACTICE CODES. USE CORNER BARS IN ALL FOUNDATION CORNERS TO MATCH REINFORCEMENT SIZE AND SPACING. 3. ALL STRUCTURAL STEEL SHALL BE ASTM A-36 STEEL ALL BOLTS SHALL BE ASTM A-325 GRADE. ALL ANCHOR BOLTS SHALL BE ASTM A-307 GRADE. 4. ALL STRUCTURAL STEEL SHALL BE FREE OF SCALE, RUST, OIL AND OTHER DELETERIOUS MATERIAL AND SHALL BE COATED WITH RUST INHIBITIVE PAINT. 5. ALL TIMBER SHALL HAVE A MINIMUM FIBER STRESS OF 1.250 PSI UNLESS OTHERWISE NOTED ON DRAWINGS. 6. ALL TIMBER IN DIRECT CONTACT WITH STEEL OR CONCRETE SHALL BE PRESSURE TREATED, HAVE AN APPROVED SEPERATING, MATERIAL, OR HAVE GALVANIZED ANCHOR SEAT. 7. ALL BEARING PARTITIONS SHALL BE SECURED TO ADJACENT PARTITIONS, AND SHALL HAVE AT LEAST A 3-STUD POST ALL ENDS AND CORNERS AND AT EACH END OF WINDOW AND DOOR OPENINGS. 8. ALL PARTITIONS GREATER THAN 10 FEET HIGH WITHOUT A LATERAL SUPPORT SHALL HAVE DOUBLE 2 X 4 STUDS AT 16" O.C. (NAILED TOGETHER WITH 10D NAILS AT 6" O.C.) 9. USE WASHERS AT ALL BOLTED TIMBER CONNECTIONS. 10. ALL BEARING WALL OPENINGS SHALL HAVE (2) 2 X 12 HEADERS (TYPICAL UNLESS NOTED) WITH 1/2" PLYWOOD IN BETWEEN. 11. COORDINATE ALL STRUCTURAL WORK WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR VERIFICATION OF LOCATIONS DIMENSIONS OF ALL PROJECT REQUIREMENTS. u" GYPSUM WOOD BOARD 1 X 4 PT. _WOCD_ FJRR N�,- ; , ^ 2 X 6 PT. WOOD JAMBS W/ u" ?TAP -CONS W/ 1-3/4" EMBED ® V'-STAGGEPED:- WOOD CASING TR'rl--- WD. DOOR FRAME ANCHORED TO WOOD BLOCKING WITH SEE PRODUCT APPROVAL FOR ANCHORING INSTALLATION METAL CLAD HOLLOW DOOR ( SEE SCHEDULE FOR SIZE ) SEALANT STUCCO FINISH 8" C.M.U. 3"=1'-0" 12. SUBMIT 3 SETS SHOP DRAWINGS FOR THE ARCHITECTS REVIEW OF ALL ITEMS REQUIRING FABRICATION. DO NOT FABRICATE UNTIL APPROVED. 13. CONCRETE: A- COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS: SLABS ON FILL ---------------- 2500 PSI ALL OTHER POURED IN PLACE CONC._ 3000 PSI GROUT ---------------------- 3000 PSI 14. MINIMUM CONCRETE COVER OVER REINFORCING STEEL AS FOLLOWS: FOOTING 3" COLUMNS 1-1/2" BEAMS 1-1/2" INTERIOR SLABS 3/4" EXPOSED SLABS 1-1/2" 15. PROVIDE 12" HIGH WATER HAMMER ARRESTING CHAMBER AT EACH FIXTURE GROUP. 16. CONTRACTOR SHALL PROVIDE SEPERATE BIDS FOR COPPER AND PVC WATER LINES. 17. ALL MATERIALS AND FIXTURES USED MUST BE BRAND NEW. 18. FIRE STOPS SHALL BE PROVIDED AROUND TOP, BOTTOM, AND SIDES OF SLIDING DOOR POCKETS. 19. STRUCTURAL WOOD, SUCH AS 4 X 4'SwAF�-! 4 X 6'S SHALL BE DOUGLAS FIR. 2 X` 4'S ;{�SEffR STRUCTURAL WOOD POST i1COMPOSITE"; YELLOW 'SOUTHERN PINE #2 OR ;,BETTER. i 20. :ALL -ROOF JOISTS, TRUSSES, LOOKOUTS, BEAMS AND GIRDERS SHALL BE SECURED WITH APPROVED METAL STRAPS, CLIPS AND 'ANCHORS AT CONNECTIONS. 21. ROOF TRUSSES AND JOISTS SHALL BE PROVIDED WITH PERMANENT CROSS/LATERAL A� D _ ALL_,BRACING. REQUIRED TO' RESIST UPLIFT- AND' LATERAL FORCES. TERMITE STATEMENT FBC,SECTION 1516.1 TERMITE PROTECTION. PRIOR TO THE BUILDING FINAL INSPECTION A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: 'THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES, TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.' GARAGE OVERE,4- 2 X 6 P.T. WOOD . W/ 5' X 1/2' DIA. A BOLTSO 24" O.C.( TOP 4 BOTTOM ) (OR AS PER N.O./ 8' CONC. BLOCK COL. (SEE FOUND PLAN FOR SIZE A SEE ELEVATION F WOOD DOOR STO DETAIL REVISION BY W A� V1 0 *4 I -I n w o� 00 el N O 0 �O i� rn 4 L LL � a 0 ,4448 V A; it a nZ O 1V1 OZ o W 0 � In 5 co Q ai U at E cd r Q �i N DATE S-ay•L)s SCALE AS SHOWN DRAWN JOB SHEET A-6 SHEET OF M. q. 'dAU.=_ ARCHITECT IA . S 25 1 REG