Loading...
05-766-007tX Ewa Uz N W Z ZLL a C EGRE55 WINDOW DETAIL FBC 1005.4.2 K, o PILASTER 's DETAIL 4' SMOOTH STUCCO BA (3/4' RAISE] WINDOW OPr FRONT ELE� WINDOW BAND DETAIL TH STUCO )TER 3 /4 II HIND DEVICE 'MAX HEIGHT OPEN AREA 50. FT. NTS, X4" WOOD BACKING TOP OF WALL OINET P WALL CABINET ITERIOR PARTITION WITH 5/8" METAL STUDS AT 16' O.C. ,TE K4" WOOD BAKING TOP OF WALL fBINET 3ASE WALL CABINET SECTION VIEW • 2x4@16"C/C-OR-2x6®24"C/C • A MINIMUN 2" X 4" HORIZONTAL WOOD MEMBER, SECCURELY FASTENED TO NOT LESS THAN 2 SUCH STUDS, SHALL BE INSTALLED FOR THE ATTACHEMENT OF EACH WALL HUNG PLUMBING FIXTURE AND WALL CABINET. STEEL STUDS SUPPORTING WALL HUNG PLUMBING FIXTURES SHALL BE DOUBLE OR NOT LESS THAN 20 GAGE @ 16" C/C. UJAl..,L HUNG FIXTURE DETAIL A-5 J FBC 2318.1.15 & FBC 2510.5.1.1 19/32" CDX. PLYWOOD SHEATING W/ 8d GALV. NAILS @ 6" O.C. & 3" O.C. ® GABLE END TRUSSES - PREFAB. ENGINEER WOOD TRUSSES @ 24" O.C. (AS PER MANUF. SPECS.) R-19 FIBERGLASS INSULATION SEE STRUCT. DWG FOR BEAM TYPE,SIZE & REINF. ACOUSTICAL SPRAY FINISH ON 1 /2" DRYWALL ON METAL HI -HATS @ 16" O.C. SEE STRUCT. DWG FOR MFGR./ MODEL & NAILING 1 X 2 PT FIRESTOPS ® TIE BEAM PERIMETER (8'-0" HGT. AFF. MAX.) 1 /2" DRYWALL ON 1 X 2 P.T. WD. FURRING STRIPS @ 24" O.C. PROVIDE R-3 MIN. INSULATION IN CAVITY 1 X 2 PT WOOD NAILER WOOD BASE 4" CONCRETE SLAB W/ 6"X6" 10/10 W.W.M. ON VAPOR BARRIER OVER TERMITE TREATED WELL COMP. FILL SEE STRUCTURAL DWG FOR FTG. TYPE & REINF. 6 MILL. VAPOR BARRIER 3 /T II WALL SECTION CEILING LINE (SEE PLAN FOR CEILING HEIGHT) TOP CHANNEL 25 GA 6ECURED TO TF4155 W/ 11/2' DRYWALL SCREW 11/2' DRYWALL EACH SIDE 35/8' MTL. (25 GA) STUDS 9 24' O.C. As' BOTTOM CHANNEL (25 EA) SECURED TO SLAB W/ 211/2'0 COIL NAILS NILTI ® I(o' O.C. MAX. WOOD BASE FIN, FLOOR METAL STUD PARTITION 3/4" DETAIL, 12 I6 l'-4" O.H. TYP. CONCRETE BARREL ROOF ON 1-90# MINERAL SURFACE HOT MOPPED TO 1-30# FELT TINTAGGED TO 19/32" PLYWOOD SHEATHING THE 1-30# FELT IS ANCHORED TO THE PLYWOOD SHEATHING WITH SENCO GALVANIZED, DIAMOND POINT, 1-1/4" X .120" DIAMETER. WOOD SHEATHING ANCHORAGE SHALL BE HAND NAILED IN ACCORDANCE WITH SFBC CHAPTER 29. FASTENING OF TILE SHALL COMPLY WITH SECT. 3403.3 A & B SFBC BROWARD ED. Q p w U � J mcf) OD TOP OF B.B. ELEV. +9'-6" METAL DRIP ON 1 X 2 PT. WOOD NAILER 2 X 6 ON 2 X 8 SMOOTH FINISH WOOD FASCIA - PAINTED STUCCO SOFFIT ON WIRE LATH & FELT - 4' WIDE CONT. SCREENED VENT TWO COAT STUCCO FINISH OM 8" CONCRETE BLOCK 9 GA LADDER TYPE JOINT REINF. Q 16" O.C. OF SLAB +o n /AII REVISION BY (40 4 A� A T� V1 �I (4.) O� 00 N O O to rn 0 v t�L o rn p o� 1$ U- Q ° ' z O 1V1 Oco 0 0 zi �1 d cl) N 0 t Q uw DATE 6-ay-OS SCALE AS SHOWN DRAWN JOB SHEET A-5 �f SHEET OF .M. J. q_HIU - ARCHITECT 0, , RECIL No. 10,154