6387 SW 69 ST EB-09-051-011 PLUM5ING GENERAL NOTES AND SPECIFICATIONS: o I. A. SCOPE OF WORK THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE -_ Q) DRAWINGS, SPECIFIED HEREIN AND/OR AS NEEDED FOR A COMPLETE SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO: D V) L DOMESTIC COLD AND HOT WATER PIPING SYSTEMS 2. SANITARY DRAIN AND VENT SYSTEMS I/2° HB_W/ - - - _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -- _ _ -- !1/s"_HB W/.- -- - 3. PLUMBING FIXTURES AND TRIM VAC. BREAKE - - - - - - - - - - - - - - - - - - - - - - - - _ _ _ - __ I VAC.BREAKER - -- - - - - -- - - - - 4. AIR CONDITIONING CONDENSATE DRAINS 5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER 6.PIPING INSULATION 1. SUPPORTS AND HANGERS I _ _ � __ . .. . __ I � B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE 'FLORIDA BUILDING CODE- 2001 AND LOCAL ORDINANCES AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR 0 BUILDING CONSTRUCTION", AND WATER-USE EFFICIENCY STANDARDS MANUAL I I 1, "MRS" REGULATIONS. IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS, I I 11 I THE MORE STRINGENT REQUIREMENTS WILL GOVERN: I 211 VTR — I I I I 2. CONTRACTOR TO VERIFY AT SITE THE LOCATION, ELEVATION AND SIZE OF ALL I I I I 211 I O EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING. I I I z 3. UNDERGROUND METAL PIPING SMALL BE PROTECTED WITH A COAT OF BITUMINOUS I I I Family Room COMPOUND BEFORE COVERING 11 4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS I L vim-- 'n o m �' OR °.+MOCK ABSORBERS (ARRESTORS)FIXTURES W/QUICK CLOSING VALVES SHALL HAVE WATER I I I j � _0 O HAMMER ARRESTOR FOR BOTH CW t HW. O I I C-ourtvord I , © O S. ALL FLOOR DRAINS t0 HAVE TRAP PRIMERS 1/2" LINE FROM THE NEAREST I i I 2" VTR 1,211 I p U E C PLUMBING FIXTURE. I i I 211 1/1/211 I O 'j � � � O 6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS, I L*211 I O 's E. SMALL HAVE SMOOTH IMPERVIOUS SURFACES AND SMALL BE FREE FROM DEFECTS 4 I I --� 3/4 I r` o o 11_ O AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM t0 BE CHROME PLA'M-D. I I I O a v O FIXTURES SMALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. I I I ) I o - E WAS " a2 11 3 I °; > o o p -1, UNDERGROUND WASTE LINES 3 AND ABOVE t0 BE PVC SCH. 40 AND SLOPE 1/8 /FT. I I I I o a� L a cic WASTE LINES 2" AND UNDER, AND ABOVE GROUND PIPES SLOPE ® 1/4"/FT. — - -- ---- ---- -- -- I o a o < a I I I 8. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT I I I EVERY:CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING t0 CODE. I � °�. VENT LINES TO BE PVC SHEDULE 40 AND EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH LEAD. I 1/2" UG I 10. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE 11161' AE30VE GROUND TO BE I j I g1/4t1 COPPER TYPE "L" OR "M", OR APPROVED CPVC . NO JOINTS ALLOWED UNDERiSROUND. I I I I I I I U I I 1/211 Bedroom I 1- I� N !i. PIPING I Dining Room I I I 11/211 I p p A. SUPPORT ALL PIPE FROM SOLID PORTIONS OF STRUCTURE AND AT PROPER I - - - - - - - - - - - - - - -- - - - - - - - - I I I m (ll >, m m o - INTERVALS ACCORDING WITH CODE. I I I >. m _ M v B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR I -- -- I I 211 I °'N 3 U v E 0 MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE ANT? SLEEVES. I ---._ 311 � o C � -0 0 Y -- I I I 0111 o o v a V) a 3 �� - - - — — - - — — — - --- I I I — — — — - — -- — — — — -- — — — — — — C. WHERE EXPOSED PIPES PASS THROUGH FLOORS,WALLS, OR CEILINGS, PROVIDE - ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE I I I - ice)(J(� I 1 I I DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES. PROVIDE I I 1 111/2" I I I mechanical GRAYWATER RECYCLING CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS. TANK I C_ •- 12. Gt10N8 AND TESTS . I I I I I 1 PRESSURE I ._ C INSPECTIONS TE , I T,� C ._ ._ A. CONTRACTOR SHALL BE RESPONSIBLE t0 ASK FOR INSPECTIONS t0 THE I --- 211 VTR I U:5�� I I I WATER I �+-- 0 AUTHORITIES HAYING JURISDICTION, AS THE WORK PROSSES. ALL 11/2" I, 11 ry SYSTEMS SHALL BE TESTED BY CODE AND/OR LOCAL REGULATIONS. L - - - - - 2 I / 211 I — -___T _ —-_ _ _ _ _ �R I -C3 I I I - - - - - ' - - - - - - - - - : C- ---- Kitchen SUr1P - - - - - rC�All��AL B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF I -- -- -- -� SYSTEMS SHALL ESE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE I 211 j 211 I I 2" P I •_ O U HIGHEST POINT AND ALLOWED t0 STAND UNTIL INSPECTION 15 MADE BY AN - - - - - - - - - - - - - - - - - - - - - - - - ( STERN '� > OO E 0 OWNER REPRESENTATIVE. I 3u 1 11/211 9,4" I s,;n ��.2 �� I Q �-' (� Q 10, 13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2)POUNDS OF CHLORINATED I _ - _..Y _ .`.- -;._--1 � _ - - - -� �1 - - - _ - - — _ - - I ') 4- LIME TO EACH IADOO GALLONS OF WATER(50 PPM OF AVAILABLE CHLORINE). I 1,211 " 2" 211 VfR - 211 - -- - "- _ _ _ _ _ _ _-- - -- _ - - - -- - - -L O RETAiN MIXTURE IN P IPES 24 MCXlRS AND FLUSH TWC�f HLY WITH POTABLE WATER 2 1 VTR -- 111 ACTY FILTER = O U — — — — — -- -`-...— _ _. _ _ _ _ _ _ _ _ _F1LtE LTER + EC 'O -F-� (n ' BEFORE PLACING IN SERVICE. I - _.. ._._ _ _ _ - I ri 11/211 HB W/ - -. 21. D X211 --- --- -- -:-_ SOLAR WATER HEATER OO 14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN-SERVICE TEST - j -_ VAC. BREAKER I 3" 0 211 AA 2 `- o AFTER COMPLETION OF THE INSTALLATION. I 111 311 1, 11/ " lid 411 -- -mechanical loft +,rq CONNECT t0 NEW SOY-�� r 11/ /2 above I — •- SEPTIC TANK (SEE 2W I `- - 1 2 SITE PLAN) COOL I 31, 3" (2 ) Laundry. 31) 2 I I U N U I I � � Cn Q 4"a�8"/FT I 4"��es°A I M• I _ _ I E 00 PLUM81NCx FIXTURE SCHEDULE EXTRA DEEP (20 FU) , (20 FU) I `J PL. BOX �'� -- - - _ c ACCESS FRAME HEAVY-DUCT1' -- ---- G a r a�� I a= o 00 TRAP PIX I.M NOT COLD MAW, SIZE UNITS WATER WATER SECURED COVER I I' I o, o � In WC 311 3 _ lie FLOOR I \\ I = o SURFACE \ GASKETED ABS LAY 11/2" 1 11/2" 1,211 CLEANOUT PLUG SH 211 2 11/2" 1,211 . ea. : .. e s w : a• : . SK IVl" 2 1,211 1,211 '. 1" CW SERV. Q� (25 FU) WM 21/ 2 11/2" 1,211 OW 1" SW N/A 1,211 _ ANA S L_ -=— - -- � Q) 1,211 W/VALvE t I I � � I_1_ YAC. BREAKER CONNECT t0 EXIS _ - - _. -- _ -- _ _ -- _ _ _ I •U) _a__+ WATER METER (SE I I I overhead rolling garage door I I (D SITE PLAN) I I I I � •- n THREADED COUNTERSUNK I Bedroom B e d r o c.I?1 I I I CLEANOUT PLUG --- C_ 1) FIXTURES t0 COMPLY WlFBC 2001 Plumbtng Sections COVER 406-421,603.1 4 6043 t.4,601J,.2,1.1,3, 4 -1031, AND �— F'c,r c h I I I MIAMI-DADE WATER-USE EFFICIENCY STANDARDS MANUAL - --- I ' i I •- — 2) ANTI-SCALD VALVE: ( I I I ALL SHOWERS t BATH/3M©WER COMBINATIONS SHALL •-- �_ BE PROTECTED WITH A CONTROL VALVE OF THE I I I I � � O PRESSURE BALANCE,:THERMOSTST'IC MIXING OR COM- I \� O SINATION TYPE SET.HANDLE POSITION STOPS PER I MANUFACTURERS INSTRUCTIONS At TIME OF INSTALLATION COUNTERSINK _ �;1 I �- 00 0 TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120'F. SCREW 311/1/" \ I -- == ----_-- - -- -- — LENNGTH STANDARD ' //� Iv 11 HB W/ I O I-1- (OPTIDNdLR LAEtMXS� I VAC, BREAKER I a� COST) L - - - - - - - - - - - - - - - - - - - - - -- - - - - - - -- - - - - - - - - - - - - - -- - - - - - - - - - J �°-,' U „ 4_j �.- s� N cm L✓ CLEANOUT D �"�11 L5 0 o I-1- N.T.S. a o • 5cale Sheet Scale Floor�1 / n __ °r°W1/"9 N°. Scale: 4" = 1 '-0" Joe #: os-ors GUERRERO/GCINZALEZ •s, �"r , • ENGINEERS, INC. Michael C. Guerrero. P.F_ a Mechanical Eng. Uc. /15235 Rafael L Gonzalez. P.E. Electrical Eng. Lic. #11037 of 8230 Coral Way Miami. Florida 33155 r� Tel. (305) 282-3944. Fax (305) 282-8211 bt E—moil: PROJECTSOGUER1iER000NZALEZENGiNEERS.001A 0007812 �=Y