07-1605-010F_ BOTT. OF DECKING +/— II'-0" (EXIST. CLG) FIBERGLASS DUCT BOARD R=6.0 MIN. Q DIAL. BRACING 5/6" DRYWALL ON 20 GAGE MTL. FRAMING ® 1611 O.G. COORD. IN FIELD BEVEL EDGE AIRCRAFT WIRE LIGHT FIXTURE HUNG FROM INSTRUT (NOT TYP) Soffit Section - A/A scale: n.t.s. An 1\ I EG+AAN I CAL Si=EC I F I CAT IONS AS MODEL NO. S.E. E.R. C.F.M. RLA/ HEAT MAX. CIRC. SENSIBLE NEAT TOTAL NEAT CU/AHU LRA STRIP SIZE AMP. CAPACITY(BTU) CAPACITY(BTU) CARRIER CU # 24APA598AO030 0 CARRIER AHU # FV46NB000IO 15.5 1600 21.8/ 110.0 IOKW CO-45 361 820 481 210 OUTSIDE AIR CALCULATION: TOTAL 50. FT. = 1500 NEAREST USE - 'OFFICE' PER TABLE 405.5 FBG.M OCCUPANTS/ 1000 50. FT. = 7 TOTAL OCCUPANTS = cf .1 TOTAL CFM/ PERSON REO. = 20 TOTAL OUTSIDE AIR REO. 152 CFM TOTAL OUTS 1 DE AIR PROVIDED = 200 CFM I-IVAG DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR / FIRE DAMPER(S) ✓ SMOKE DAMPER(S) ✓ FIRE RATED ENCLOSURE / FIRE RATED ROOF/FLOOR CEILING ASSEMBLY ✓ FIRE STOPPING ✓ SMOKE CONTROL ✓ A:2' GE I L I NG GRILLE SPECS. OTITUS FT2Ox45 WHITE FINISH LINEAR OTITUS FTIOx 45" WHITE FINISH LINEAR DIFFUSER OTITUS 'MB-50' SERIES MODU-BIO-G WHITE FINISH 4 WAY, SUPPLY DIFFUSER W/ 2 SLOTS, 24x24. COORD. INSTALL OF CENTER TILE W/O.G. OTITUS WHITE FINISH 'PXP' PERFORATED SCREEN I$ FRAME ONLY TRANSFER GRILLE, 24x24 OTITUS 'M15-50' MODU-BIO-G, E WHITE FINISH, 444AY, SUPPLY DIFFUSER W/ 4 SLOTS, 24x24 GOORD. INSTALL OF CENTER TILE W/ O.G. 0 0 0 260 CFM W/ 160 GFM Yv ADJ. VOLUME ADJ. VOLUME DAMPER FVAMPER IMFRIAM�i 4^� ''111�11 F� 7v/,,ju ,IRx 17,0110INF FA00 imam 1"31 mmuff, NA PA" r111111111111.10 Evil II II • � -j UTPP Ili + DOUBLE' ITj' ra 107,90r. PAM TRANSFER I L 100 CFM 4 WAY GRILLES YV ADJ. VOL. (TYPJ DAMPER Mechanical plan scale: 1/4" = 1'-0" UC - UNDERCUT DOOR I" o AMF61i i�' MEIN 14 — 12x24" PERFORATED SCREEN 4 FRAME RETURN GRILLE NOTE: BOLT UNIT (4) 5/8" STAINLESS THRU BOLTS TO EXIST. FRAME —� APPROX. LOCATION I OF NEW CU MOUNTED ON ROOF I NOTE: CONTRACTOR SHALL LOCATE EXIST. MAIN COND. LINE OR ROOF DRAIN LINES 4 TAP IN NEW COND. PIPES (TYP) IN COPPER SECONDARY EMERGENCY COND. DRAIN LINE SLOPE 1/4" PER FT. 1 1/2"COPPER PRIMARY CONDENSATION LINE SLOPE 1/4" PER FOOT in x n 11 20x2O FILTER (COORD. W/ MANUFJ I L EXIST. MTL. ROOF I STAND. VERIFY IN I FIELD (2) 18 GALV. 1 1/2"A MTL. STRAPS BOLTED TO EXIST. FRAME 6" VIA. MTL. DUCT THROUGH ROOF 200 CFM FRESH AIR INTAKE W/ VOLUME DAMPER — 20"x2O" RETURN PROVIDE APPROVED SCREENED AIR MAIN GOOSENECK AT ROOF 4 CONSULT NV BUILDING ROOFER — COORD. EXACT ROUTE IN —FIELD NEW CEILING HUMS AHU ANY CORE DRILLING SHALL UNIT IN/ DRAIN PAN REQUIRE X—RAY OF EXISTING D (SEE DETAIL) SLAB DUCT SMOKE DETECTOR 48"x I" LINEAR f 150 CFM 4 WAY DIFFUSER L DETECTOR YV ADJ. VOL. W VIA OPENING TROUBLE LIGHT DAMPER OO YV ADJ. DAMPER 50 CFM INDICATOR AT INLET (TYP) ON SIDE I WAY CITY OF SOUTH MIAMI BUILDING DEPT. MECHANICAL, SECTION APPROVED BY: DATE: o� rchert jl A r & h l te,GtUre, Mdarlda"9e'-MeMt D el 619 r1 8450 sw 201 het mllami, Wda 33189 754.264.4773 A I A NAKE5 Generd Nora: Any mars, ambigutlies, and omisslorrs Ind swings and specMcalft shill be reported to the ardh►tect for carec1lons betas any part of to work b ftled. socpr* stipdatK no additionalalowarcewll be mode In the contract and/or nranufoctM favaa byvktue of mars, ornboft ad/a anlsslons wt idh ftW trove been discovered during ttre preparation of the bid estimate and directed to our allaft in a t" MOW. DO NOT SCALE DRAWINGS. Use Nured dmensionc only. Contactor shallverifyall dmensiorwaxl conditions. In the event of a convict, wk1yIheDWVwbdWWomdhg whh the wok §75 ..-z zz Li � O i � O 0 s S Rob�rkJQ�o►p.,�•r reg'O tion no.4 ; . SlaledFW& a 3 2 Bldg. Dept. Caren. 02/04/08 1 Bldg. Dept. (arm. 01/28/08 o Issued For Permit 12/04/07 ISSUE DATE