06-809-022SUITE 500 NEW 3 #3/0 do 1 #6G. IN EXISTING 2" C. TO 200A CIRCUIT BREAKER. N500 (10,000 AIC) ( SCA) 5TH FLOOR EXISTING METER CENTER 208V, 30, IN 120/208V, 10 OUT WITH A EXISTING o0 00 3P-800A M.C.B. MAIN BREAKER �(XISTING 11 150A METER SOCKETS, 6 USED AND 5 AVAILABLE. o0 n0 00 1000A C30 E3 EXISTING 11 2P-150A MAIN BREAKERS. C30 REPLACE ONE OF THE EXISTING 150A SPARE CIRCUIT BREAKER 'N500'. oO oO oO WITH NEW 200A CIRCUIT BREAKER TO CONTROL PANEL PROVIDE 200A METER. 4TH FLOOR 3RD FLOOR LXISTING (3)3"C. 2ND FLOOR EXISTING MAIN BREAKER 208/120V 30, 4W 1000A 1ST FLOOR EXISTING GROUNDING. EXISTING (3)3"C. — FROM FP&L. N 0 T E S NEW PANEL: 'N500' PANEL VOLTAGE: 120/208V, 1PH., 3W M.C.B.: N/A BUS RATING: 225A AIC RATING: 10,000 M.L.O.: 225 LOCATION: ROOM 111 MOUNTING: FLUSH N 0 T E S CKT NO. IDENTIFICATION LOAD/ PHASE (KVA) CIRCUIT BREAKER WIRE/CONDUIT SIZE CIRCUIT BREAKER LOAD/ PHASE (KVA) IDENTIFICATION CKT NO. "A" "C" TRIP POLES POLES TRIP "A" "C" 1 REC. 100 0.9 20 1 2#12, 1#12 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 0.9 REC. 102, 103 2 3 REC. 102 1 0.54 20 1 2#12, 1#12 GND IN 3 4 C 2#12, 1#12 GND IN 3/4"C 1 20 0.9 REC, 104, 105 4 5 REFER. 102 0.5 20 1 2#12, 1#12 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 0.72 REC. 105 6 7 TELEPHONE ROOM REC 0.36 20 1 2#12, 1#12 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 0.54 REC. 106 E 9 TELEPHONE ROOM REC. 0.36 20 1 2#12, 1#12 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 0.54 REC. 106 10 11 REC. 107 0.72 20 1 2#12, 1#12 GND IN 3 4 C 2#12, 1#12 GND IN 3/4"C 1 20 0.9 REC. 107 12 13 REC. 101, 108 0.9 20 1 2#12, 1#12 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 0.9 REC, 111 14 15 REC. 111 0.72 20 1 2#12, 1#12 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 1.0 COPIER 101 16 17 RFC, 101 0.54 20 1 2#12, 1#12 GND IN 3 4 C 2#12, 1#12 GND IN 3/4"C 1 20 0.36 REC. 101 18 19 REC. 101 0.5 20 1 2#12, 1#12 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 0.5 REC. 100 20 21 AC-1 4.35 1 60 2 2#4, 1#10 GND IN 1"C 1 20 1 0.0 SPARE 22 23 4.35 2#12, 1 #12 GND IN 3/4"C 1 20 1.1 LTG 101, 102,108, 111, 113 24 25 AC-2 3.35 40 2 2#8, 1#10 GND IN 3/4"C 2#12, 1#12 GND IN 3/4"C 1 20 1.4 LTG 103, 104 26 27 3.35 2 12 1 #12 GND IN 3 4"C 1 20 1.2 LTG 105, 106, 107, 111 28 1 29 AC-3 0.03 20 1 1 2#12, 1 #12 GND IN 3/4"C 2#12, 1 #12 GND IN 3/4"C 1 20 1.1 LTG 108, 109, 111 30 31 SPARE 0.0 20 1 2#12, 1 #12 GND IN 3/4"C 1 20 0.5 REC 111 32 1 33 CU-1 5.6 70 2 2#4, 1#10 GND 1N 1 C 2#12, 1#12 GND IN 3/4"C 1 20 1.0 LTG 101 34 1 1 35 5.6 2#8, 1#10 GND IN 3/4"C 2 35 2.8 CU-2 36 1 37 SPARE 0.0 20 1 2.8 38 1 39 EN-1-1 2.1 25 2 1 2#10, 1#10 GND IN 3/4C 1 2#12, 1#12 GND IN 3/4"C 1 20 1.04 CU-3 40 41 2.1 1 1 0.2 ROOF RECEPTACLE 42 TOTALS: 18.6 18.2 8.7 10.5 TOTAL KVA PHASE A: 27.3 MAX. CONN. PHASE KVA: 28.7 TOTAL KVA PHASE C: 28.7 TOTAL CONNECTED KVA: 56.0 TOTAL DEMAND KVA: 39.05 TOTAL DEMAND AMPS: 187.7 NOTES: 1. NON —COINCIDENT LOADS. SUITE 500 3/4" CONDUIT (TYP. ALL DEVICES) F F F F F F 3/4' CONDUIT (TYP. ALL DEVICES) 5TH FLOOR 4TH FLOOR 3RD FLOOR 2ND FLOOR CORRIDOR F't:arU Of IZC)tJ i71 f r 1\1%tEPd ATL ij?N A OF A/C, ;1V'1, HOT WATER 1 ri.Fi� LT OTFFa E� [JFPa ��.rr TO OBTA!N �,NL) EXISTING ( CaRrt CT NVIR SIZES AND t�vi:F7t UF�F4 I [ F1ROTF C f FO . !C!T'i . FIRE ALARM -p - PANEL 4 7 TG I Ef,C;T,'F;C'F FO 1ST FLOOR FIRE ALARM RISER DIAGRAM GENERAL NOTES: 1. PROVIDE SYSTEM WIRING AND DEVICES FULLY COMPATIBLE WITH EXISTING FIRE ALARM SYSTEM. 2. PROVIDE ADDITIONAL POWER SUPPLY MODULE AND BATTERY CAPACITY AS REQUIRED FOR NEW DEVICES. PROVIDE BATTERY CALCULATIONS WITH SHOP DRAWING SUBMITTALS. 3. CONTRACTOR TO VERIFY EXACT LOCATION OF EXISTING FIRE ALARM PANEL PRIOR TO BID AND INCLUDE IN HIS PRICE ALL THE NECESSARY FOR INSTALLATION. 4. COORDINATE EXACT LOCATION OF DEVICES WITH ARCHITECTURAL DRAWINGS AND FEATURES TO AVOID CONFLICTS. Y; W'F iYY 1 g , *—AG.4.,a„' L X k "SUBJECT TO FIELD INSPf ;T10 ",, ` v. \, ,. .1 GENERAL NOTE: PROVIDE CONDUIT BENDING RADIUS TO COMPLY WITH FIBER OPTIC CABLE BENDING REQUIREMENTS. PHONE & DATA RISER DIAGRAM DO NOT INSTALL .FIRE F , THIS D WINNG! SEF01RE INSTALTA 11 N Fire Alarm contractor's woricil"Ig piayis si:,0 be subn-itted for pemit apprm7a1 to P liarni. Dade County rim Depa t�Y rrt. Approved for Buildi%-- Pc:rrpdt ot Pate , 701,/ � 13y r.• r MGE ARCH ITECTS 150 Alhambra Circle, Suite 700 Coral Gables, Florida 33134 T.305.444.0413 F.305.441.6404 www.mgearchitects.com AA-F000121 CONSULTANTS 5757 Blue Lagoon Dr,, v 400 Miami, FL 33126 Phone: 305-266-6553 Fax: 305-266-6695 ENGINEERING FOR ARCHITECTURE 7 www.tic-enryineers.com © Copyright 2005 TLC Engineering for Architecture, Inc. EB #0000015 TLC NO:606504 DRAWN BY: ACU CHECKED BY: CBB APPROVED BY: CBB 100% CONSTRUCTION DOCUMENTS PROJECT NAME GARSH INVESTMENTS CORPORATE OFFICES l9 South Miami, Flor••)"d• a ♦••••r JOB NUMBER: • Wr 2C;2*.00C DATE: i• 04/24/04 CAD FILE NO: • " AGENCY NO: • "• l".. REVISIONS/SUBMISSIONS: •"°"•" �`• "• vest i i • • V U " U i SEAL: Charles B. Buchanan,\Jr., E. Florida License' #54128 DRAWING TITLE: ELECTRICAL RISER • DRAWING NO: E-4