06-809-018
x -- 0 rn ELECTRICAL SYMBOL LEGEND BASIC MATERIALS BASIC MATERIALS CONT. FIRE ALARM/DETECTION SYSTEM SYMBOL DESCRIPTON SYMBOL DESCRIPTION SYMBOL DESCRIPTION Sa SINGLE POLE SWITCH (SUBSCRIPT INDICATES ITEM CONTROLLED) f ENCLOSURE NEMA RATING F❑ MANUAL PULL STATION S3 THREE-WAY SWITCH L[:jOAR 3 3R NON -FUSED DISCONNECT SWITCH, SIZE & # OF POLES ® CEILING SMOKE DETECTOR, PHOTO -ELECTRIC SWP SINGLE POLE SWITCH WITH WEATHERPROOF COVER NF TYPE UNLESS OTHERWISE NOTED AR DENOTES AMP RATING OF SWITCH E = ELEVATOR WITH RECALL CONTACTS SLV LOW VOLTAGE SWITCH I = IONIZATION SF FAN SWITCH A OAF 3R FUSED DISCONNECT- LETAR DUCT SMOKE DETECTOR SM MANUAL MOTOR STARTER WITH OVERLOAD HEATERS DENOTES AMP RATING OF SWITCH R = RETURN SO DIMMER SWITCH MCP AF DENOTES AMP FUSE SIZE S = SUPPLY (1500 WATTS UNLESS OTHERWISE INDICATED) SIZE \ # OF POLES ® SUPERVISED CONTROL RELAY LN 30 � COMBINATION MAGNETIC MOTOR STARTER, SIZE & # OF POLES Q� DUPLEX RECEPTACLE 3 POLE UNLESS OTHERWISE NOTED ENCLOSURE NEMA RATING. DUCT SMOKE REMOTE ALARM INDICATING LAMP, W/ TEST SWITCH, WALL MOUNTED 72" AFF 0- TWIST LOCK RECEPTACLE NEMA STARTER SIZE T SURGE PROTECTION TYPE (TVSS) _�.— BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, -- REMOTE INDICATING LAMP FIRE ALARM WITH TEST SWITCH � WALL MOUNTED 72"'AFF SPP DUPLEX RECEPTACLE SURFACE MOUNTED PEDESTAL MOUNTED RECEPTACLE 7�— RRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, �--�- FLUSH MOUNTED COMBINATION AUDIBLE/VISUAL � XXCD NOTIFICATION DEVICE FLOOR OUTLET BOX AND DUPLEX RECEPTACLE CD = CANDELA RATING WITH APPROPRIATE FLANGE. BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. SS FIRE ALARM SPEAKER - CEILING MOUNTED CONDUIT SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE ® AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). XXCD CD = CANDELA RATING AND ONE COMBINATION W/ VOICE/DATA OUTLET ® FLOOR OUTLET BOX WITH TWO DUPLEX RECEPTACLES ��-� aRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, UNDERGROUND OR UNDER FLOOR. tJ �WALL MOUNTED SPEAKER WITH STROBE XXCD CD = CANDELA RATING AND ONE COMBINATION W/ VOICE/DATA OUTLET POKE THRU ---,BRANCH CIRCUIT CONDUIT EXPOSED FIRE ALARM SPEAKER - WALL MOUNTED I� GROUND OR GROUND ROD AS NOTED XXCD CD = CANDELA RATING DUPLEX LE WITH EACH HALF ON SEPARATE CIRCUIT RESHALLCEPTACBE -�'EM�.� EMERGENCY BRANCH CONDUIT O FIR AR WITH STROBE -CEILING MOUNTED (D= (BREAKER TWO POLE WITH COMMON TRIP) CD ANDELAKER RATING Q� DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER UP CONDUIT TURNING UP VISUAL SIGNALING UNIT, WALL MOUNTED �DN CONDUIT TURNING DOWN (NO AUDIO DEVICE) DUPLEX RECEPTACLE WITH TOP HALF SWITCHED CONDUIT STUB SPRINKLER TAMPER SIMPLEX RECEPTACLE (EWC DENOTES SWITCH CONNECTION ELECTRIC WATER COOLER. COORDINATE WITH EWC EWC Z CONDUIT CONTINUED SPRINKLER WATERFLOW FS INSTALLER FOR MOUNTING HEIGHT) -v`. FLEXIBLE CONDUIT SWITCH CONNECTION GFI RECEPTACLE. WP DENOTES WEATHERPROOF COVER. — — --- EXISTING TO BE REMOVED FP FIRE ALARM SYSTEM PRINTER W9-- GFI RECEPTACLE MOUNTED ABOVE COUNTER EXISTING TO REMAIN ZONE ADDRESSABLE MODULE TWO DUPLEX RECEPTACLES WITH COMMON COVER EXISTING AFFECTED BY THIS PROJECT O CEILING HEAT DETECTOR 135' F UNLESS OTHERWISE — — - - -- - - FUTURE INDICATED. TWO DUPLEX RECEPTACLES WITH COMMON COVER FACP MOUNTED ABOVE COUNTER NEW oiml FIRE ALARM CONTROL PANEL ISOLATED GROUND DUPLEX RECEPTACLE, FATC IG (ORANGE DEVICE) ---GRID FIRE ALARM TERMINAL CABINET LIGHTING DUPLEX RECEPTACLE FAAP NOTE: ---caw— FIRE ALARM ANNUNCIATOR PLAN - FLUSH MOUNTED TICK MARKS SHOWN ON ANY DEVICE REPRESENTS RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT (RED DEVICE) TYPICAL--C�—I FLUORESCENT STRIP FIXTURE F FIRE ALARM SYSTEM CONDUIT AND WIRING �! ��� FOR ANY DEVICE IN LEGEND FIXTURE DESIGNATION —A © CLOCK RECEPTACLE L�JI FLUORESCENT FIXTURE TELEPHONE/COMPUTER RACEWAY SYSTEM SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED CIRCUIT NUMBER---2 a LOWER CASE LETTER INDICATES CONTROL CIRCUIT SWITCH LEG E�E] LIGHTING CONTROL TIME CLOCK FLUORESCENT FIXTURE DIAGONAL SHADING DENOTES EMERGENCY LIGHT FIXTURE. ® PHOTOCELL, MOUNTED ON ROOF FACING NORTH FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX GN GROUND BAR PLUG-IN STRIP WITH RECEPTACLES, 18" O.C. UNLESS O HID, FLUORESCENT, OR INCANDESCENT FIXTURE -- -- --- X = MOUNTING (F)LUSH, (S)URFACE, (M)ODULAR FURNITURE ADAPTOR (P)OLE, F(L)OOR, & (R)ACEWAY OTHERWISE INDICATED v FLUORESCENT, OR INCANDESCENT WALL WASHER. N = # OF VOICE JACKS JUNCTION BOX, CEILING / WALL MOUNTED (3— ACCENT FLOOD LIGHTING - AIMING AS INDICATED N = # OF DATA JACKS N = # OF FIBER PORTS ©F JUNCTION BOX FLOOR MOUNTED EXIT LIGHT FIXTURE ® DIRECTION ARROWS AS SHOWN N = # OF VIDEO PORTS --�fj JUNCTION BOX- WALL MOUNTED (SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) X N N N N COMMUNICATIONS "INFORMATION OUTLET" MTD. AT },... JUNCTION BOX- FURNITURE SYSTEM FEED F(91 WALL MOUNTED EXIT LIGHT FIXTURE d ROOM # - OUTLET # RECEPTACLE HEIGHT UNLESS OTHERWISE NOTED. ■ CONDUIT SEAL -OFF FITTINGS 0-0-0 EXTERIOR LIGHT FIXTURE WITH ARMS AS SHOWN C = ABOVE THE COUNTER REFER TO SPECIFICATIONS FOR MANUFACTURER'S W = WALL MOUNTED PART NUMBER. MAGNETIC MOTOR STARTER OR CONTACTOR ON DRAWINGS SIZE AS NOTED TRACK WITH TRACK LIGHT FIXTURE (TRIANGLES d WALL PHONE EDH-X INDICATE QUANTITY OF LIGHT FIXTURES) P = PAY PHONE LE]_A\M ELECTRIC DUCT HEATER BATTERY PACK WITH WIN HEADS ® TELEPHONE OUTLET PEDESTAL MOUNTED MOTOR CONNECTION, NUMBER DENOTES HORSEPOWER E] TELEPHONE OUTLET FLOOR MOUNTED VARIABLE FREQUENCY DRIVE TELEVISION RACEWAY DISTRIBUTION SYSTEM FD-D-d DIRECT DIGITAL CONTROL PANEL TRANSFORMER TELEPHONE/COMPUTER TERMINAL BOARD N❑ TELEVISION OUTLET FOR ANTENNA TV TELEVISION SIGNAL WALL OUTLET _._.>® ___ TELEPHONE TERMINAL CABINET -TV--.__,., TV DISTRIMU11ON SYSTEM RACEWAY T -----,,TELEPHONE SYSTEM RACEWAY MO MAGNETIC LOCK NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. GENERAL NOTES: 1. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. 2. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. ABOVE -COUNTER RECEPTACLES SHALL BE MOUNTED 6" ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. 3, EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. 4. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110. B. THE EXCLUSIVELY -DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408. 5. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE -RESISTIVE ASSEMBLIES, (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET: A, ALL ELECTRICAL BOXES SHALL BE METALLIC. B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE, C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). E. PROVIDE A WALL AROUND OUTLETS LARGER THAT 16 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET. G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE -RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES, H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING. 6. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED. 7. ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED DOWN. 8. THE NUMBER OF ARROWHEADS ON THE HOMERUNS DENOTES THE NUMBER OF CIRCUITS. ELECTRICAL DRAWING INDEX SHEET DESCRIPTION ISSUED E-0 GENERAL NOTES, LEGEND, FIXTURE SCHEDULE AND DRAWINGS LIST Yes E-1 PARTIAL FIRST FLOOR PLAN LIGHTING Yes E-2 PARTIAL FIRST FLOOR PLAN POWER Yes E-3 ROOF PLAN Yes E-4 ELECTRICAL RISERS AND PANEL SCHEDULES Yes E-5 DETAILS t 10 Yes E-6 S11BO\ ELECTRICAL SPECS 0 oft Yes 1; lF��-� 1NSp ELECTRICAL DEMOLITION NOTES 1. WITHIN THE AREA IDENTIFIED, UNLESS SPECIFICALLY NOTED OTHERWISE, CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING UNUSED ELECTRICAL EQUIPMENT INCLUDING BUT NOT LIMITED TO LIGHTING FIXTURES, WIRING DEVICES, AND ASSOCIATED CONTROLS, ETC. REMOVE ALL UNUSED WIRING COMPLETELY INCLUDING CONDUIT AND CONDUCTORS BACK TO POWER SOURCE OR NEXT ACTIVE OUTLET. WHERE CONDUIT IS INACCESSIBLE, REMOVE CONDUCTORS AND CUT BACK CONDUIT FLUSH WITH SLAB OR WALL. PATCH OPENING TO MATCH EXISTING FINISH. WHERE EXISTING WIRING EXTENDS OUTSIDE OF THE AREA BY NATURE OF THE ORIGINAL INSTALLATION, CONTRACTOR SHALL MODIFY EXISTING WIRING AS REQUIRED TO MAINTAIN CONTINUITY OF EXISTING CIRCUITRY SUCH THAT NO EQUIPMENT TO REMAIN IS LEFT WITHOUT SERVICE. 2, ALL REMOVED ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR WITH THE APPROVAL OF THE OWNER AND SHALL BE RE -USED OR REMOVED FROM THE SITE. 3. THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE EXISTING CONDITIONS PRIOR TO COMMENCING WORK AND SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS HIM FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS. 4, PRIOR TO BID, THE EXTENT AND UNDERSTANDING OF THE WORK TO BE PERFORMED SHALL BE CLEARLY ESTABLISHED SUCH THAT NO ADDITIONAL COSTS WILL BE INCURRED BY THE OWNER. ANY WORK, OTHER THAN AS DESCRIBED ON ANY ITEM OR SYSTEMS SHALL BE QUALIFIED WITH THE BID. CONTRACTOR TO MOVE EXISTING CONDUITS AND WIRING, AS REQUIRED FOR NEW CEILING CONSTRUCTION. VERIFY PRIOR TO BID, 5. PRIOR TO COMMENCING WORK, CONTRACTOR SHALL DISCONNECT POWER IN THE DEMOLITION AREA INCLUDING POWER FOR THE LOW -VOLTAGE SYSTEMS SUCH AS FIRE ALARM, CONTROL WIRING, ETC. 6. CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DEMOLITION WORK. CONTRACTOR SHALL VERIFY IN FIELD ROUTING OF ALL EXISTING FEEDERS PRIOR TO DEMOLITION. 7. CONTRACTOR SHALL PROVIDE TEMPORARY POWER WHERE REQUIRED DURING DEMOLITION AND CONSTRUCTION SCOPE OF WORK. 8. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR AND SHALL BE COORDINATED WITH OTHER TRADES. 9. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY FOR THE DURATION OF THE WORK. 10. ALL DEVICES SHALL BE REMOVED UNLESS OTHERWISE NOTED. 11. ANY EXISTING DEVICE NOT USED SHALL BE RETURNED TO THE OWNER. LIGHTING FIXTURE SCHEDULE REQUIRED TYPE DESCRIPTION MANUFACTURER MODEL NUMBER VOLTAGE LAMPS VA REMARKS NUM. TYPE C2D 2X2, 2 LAMP, RECESSED, LENSED, STATIC DAYBRITE 2DPG-2-31U1-FS01-120-1/2-EB 120 2 31U1 70 TROFFER C2DE SAME AS TYPE 'CD2' WITH EMERGENCY DAYBRITE 2DPG-2-31U1-FS01-120-1/2-* 120 2 31U1 70 * PROVIDE FIXTURE WITH EMERGENCY BALLAST. BATTERY BALLAST 2X2, 2 LAMP, RECESSED FIXTURE, 9-CELL DAYBRITE 2P3-G-S-2-31U1-33-AL-120-1/2-EM D2 LOW IRIDESCENCE, SEMI-SPECULAR, 3" 120 2 31U1 70 DEEP PARABOLIC LOUVER D2E SAME AS TYPE 'D2' WITH EMERGENCY DAYBRITE 2P3-G-S-2-31U1-33-AL-120-1/2-* 120 2 31U1 70 * PROVIDE THIS FIXTURE WITH EMERGENCY BALLAST. BATTERY BALLAST t i CUSTOM MADE FLOURESCENT FIXTURE WITH DELTALIGHT USA W SERIES 120 2 F32T8 70 * REFER TO ARCHITECTURAL DRAWINGS FOR LENGTH SPOT LIGHTS, OF FIXTURE. M PENDANT MOUNTED DECORATIVE LIGHTING SCHMITZ LIGHTING 16205-* 120 1 10OW T10 100 * FIXTURE SELECTION PER ARCHITECT. FIXTURE WITH HALOGEN LAMP HALOGEN N DECORATIVE SPOTLITE MP LIGHTING SR85-* 120 1 50W 50 * FIXTURE SELECTION BY ARCHITECT. COORDINATE MR16 WITH ARCHITECT FOR FINISH OF FIXTURE. P 6" ROUND, RECESSED FLOURESCENT CAPRI CF026W-G24D-U-* 120 1 26W 30 * COORDINATE WITH ARCHITECT FOR FINISH OF DOWNLIGHT, G24D FIXTURE. P2 SPOT LIGHT FOR CUSTOM MADE DELTA LIGHT USA * SEE REMARKS 120 1 100W 100 * REFER TO FIXTURE TYPE H FOR EXACT FLOURESCENT FIXTURE. PAR SPECIFICATION. PE SAME AS TYPE 'P' WITH EMERGENCY CAPRI CFQ26W-G24D-U-* 120 1 26W 30 * PROVIDE FIXTURE WITH EMERGENCY BALLAST. BATTERY BALLAST G24D DECORATIVE TRACKLIGHT MP LIGHTING SR85-* * FIXTURE SELECTION BY ARCHITECT. COORDINATE 'j' 120 1 50W 50 WITH ARCHITECT WITH FIXTURE FINISH. PROVIDE MR16 LIGHT WITH TRACK. REFER TO LIGHTING PLAN FOR TRACK LENGTH. U DECORATIVE WALL LIGHT SCHMITZ LIGHTING 18820,46 120 1 28W T5 35 * FIXTURE SELECTION BY ARCHITECT. COORDINATE WITH ARCHITECT FOR FINISH OF FIXTURE. X UNIVERSAL MOUNTED POLYCARBONATE EXIT BEGHELLI VA4RSA 120 1 LED 10 COORDINATE MOUNTING HEIGHT WITH ARCHITECT. SIGN WITH NICKLE CADIUM BATTERY. FINISH TO BE SELECTED BY ARCHITECT. MGE ARCHITECTS 150 Alhambra Circle, Suite 700 Coral Gables, Florida 33134 T.305.444.0413 F.305.441.6404 www. m g e a rch i to ct s. co m AA-F000121 CONSULTANTS 5757 Blue Lagoon Dr., :400 Miami, FL 33128 Phone: 305-266-6553 Fax: 305-266-6695 ENGINEERING FOR ARCHITECTURE www.tic-engineers.com o Copyright 2005 TLC Engineering for Architecture, Inc. EB #0000015 TLC NO:606504 DRAWN BY: ACV CHECKED BY: CBB APPROVED BY: CBB 100% CONST PROJECT NAME GARSH INVESTMENTS CORPORATE OFFICES South Miami, Florida' JOB NUMBER: DATE: CAD FILE NO: AGENCY NO: 20OC. :. ; 04/24/Oe . • REVISIONS/SUBMISSIONS: . • • • r • r . r r �rr .rrry r.� SEAL' i " x � t . ILP r .a .'. ., Iw+1 t 3. Charhes B. BUChanan, jr , P.E. Florida License` #54128 DRAWING TITLE: GENERAL NOTES LEGEND AND DRAWINGS LIST DRAWING NO: E-0 J **I