Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06-809-008
S N Q) c m E v Cn 0 lf) 6� 0 N d N �r N I a LO 0 MQD U) 0 .N Q0 rurari I LV11 VVIY II\VL WATER HEATER WITH FLOW CONTROL VALVE UNION NOTE: ALL PIPING BETWEEN WATER HEATER AND FAUCET SHALL BE MINIMUM 1/2". TANKLESS ELECTRIC WATER HEATER No Scale INSULATED PIPE HANGER No Scale CW SUPPLY T CHROME PLA1 ESCUTCHEON WATER CLOSET No Scale PIPE HANGER (SEE SPECS.) ) SHEETMETAL .E W/FLARED E l=.•, ,.,., THE HANDLE OF THE FLUSH LEVER SHALL FACE THE WIDE SIDE OF THE STALL (NO EXCEPTIONS). System No. C—AJ-1044 (formerly system no. 319) F Rating — 2, 3 and 4 Hr (see items 2A and 4) T Rating — 0 Hr L Rating At Ambient — 2 CFM/sq ft L Rating At 400 F — less than 1 CFM/sq ft SECTION A -A 1. floor or wall assembly lightweight or normal weight (100-150pcf) concrete. except as noted in table under item 4, min thickness of solid concrete floor or wall assembly is 4-1/2". floor may also be constructed of a min. 6" thick. ul classified hollow core precast concrete units*. when floor is constructed of hollow core precast concrete units, packing material (item 3) and caulk fill material (item 4) to be installed symmetrically on both sides of floor, flush with floor surface. wall assembly may also be constructed of any ul classified concrete blocks*. max. dia. of opening is in solid lightweight or normal weight concrete. floor is 32" max. dia. of opening in floor constructed of hollow --core precast concrete units is 7". see concrete blocks (cant) and precast concrete units (cfty) categories in the fire resistance directory for names of manufacturers. 1A. steel sleeve — (optional, not shown) — max. 15" id (or smaller) schedule 10 (or heavier) steel sleeve cast or grouted into floor or wall assembly. sleeve may extend a max. of 2" above top of floor or beyond either surface of wall. max. 16" id (or smaller) mina 0.028 wall thickness (or heavier) galvanized steel sleeve cast or grouted into floor or wall assembly. sleeve may extend a max. of 1/2" beyond either surface of floor or wall. 2. through penetrants — one metallic pipe, conduit or tubing to be installed either concentric ally or eccentric ally within the firestop system. max. annular space between pipe, conduit or tubing and edge of through opening or sleeve is dependent on the parameters shown in item 4. min. annular space between pipe or conduit and edge of through opening is 0". (point contact). pipe conduit or tubing to be rigidly supported on both sides of floor or wall assembly. the following types and sizes of metallic pipes, conduits or tubing may be used: A. steel pipe — nom. 30" dia. (or smaller) schedule 10 (or heavier) steel pipe B. iron pipe — nom. 30" dia. (or smaller) cast or ductile iron pipe C. conduit — nom. 6" dia. (or smaller) rigid steel conduit D. conduit — nom. 4" dia. (or smaller) steel electrical metallic tubing E. copper tubing — nom. a" dia. (or smaller) type I (or heavier) copper tube F. copper pipe — nom. 6" dia. (or smaller) regular (or heavier) copper pipe 3. packing material — polyethylene backer rod or nom. 1" thickness of tightly packed min.eral wool butt or glass fiber insulation firmly packed into opening as a permanent form. packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of caulk fill material (item 4). 4. fill, void or cavity material* — caulk — applied to fill the annular space flush with top surface of floor. in wall assemblies, required caulk thickness to be installed symmetrically on both sides of wall, flush with wall surface, at point contact location between penetrant and sleeve or between penetrant and concrete, a min. 1/4" dia, bead of caulk shall be applied at top surface pipe conduit or tubing to be rigidly supported on both sides of floor or wall of floor and at both surfaces of wall. the hourly f ratings and the min. required caulk thickness' are dependent upon a number of parameters, as shown in the following table: min. floor nom. pipe tube or wall or conduit max. annular min. caulk f thickness, in. dia.., in. space, in. thickness, in. rating, hr. 2-1/2 1/2-12 1-3/E 1/2 2 2-1/2 1/2-12 3-1/4 1 2 4-1/2 1/2-6 1-3/8 1/4 (A) 2 4-1/2 1/2-12 1-1/4 1/2 3 4-1/2 1/2-20 2 1 3 4-1/2 1/2-20 2 1 3 4-1/2 1/2-12 3-1/4 1 3 4-1/2 1/2-6 1-3/E 1 (B) 4 (A) min. 2` thickness of mineral wool batt insulation required in annular space. (B) min. 1" thickness of mineral wool batt insulation required in annular space. on both sides of floor or wall assembly. min 1" thickness of caulk to be installed flush with each surface of floor or wall assembly. minnesota mining and manufacturing co. — cp 25wb+. *bearing the ul classification marking 3 WALL/FLR - CONC - PIPE - 2/3/4 HR 1 System No. C-AJ-1044 MGE ARCHITECTS 150 Alhambra Circle, Suite 700 Coral Gables, Florida 33134 T.305.444.0413 F.305.441.6404 www.mgearchitects.com AA-F000121 CONSULTANTS 5757 Blue Lagoon Dr., 000 Miami, FL 33128 Phone: 305-266-6553 ENGINEERING Fax: 305-266-6695 FOR ARCHITECTURE www.tic-engineers.com © Copyright 2005 TLC Engineering for Architecture, Inc. EB #0000015 TLC NO:606504 DRAWN BY: EMB CHECKED BY: EMB APPROVED BY: RSM 100% CONSTRUCTION DOCUMENTS PROJECT NAME GARSH INVESTMENTS CORPORATE OFFICES South Miami, Florida JOB NUMBER: • u • • r • 2006.00C DATE: 04 P,410E CAD FILE NO: • • AGENCY NO: r • r • • • REVISIONS/SUBMISSIONS: :" .• ` r r• rrur o r • • U V • U • r V • r • ► U • V Y r • r SEAL: ... , • l V.rp' �� �:� LI ��,4 ����..a M• t , i � ••r••� Raul S. Mastrapa, P.E. Florida License #40182 DRAWING TITLE: DETAILS PLUMBING DRAWING NO: P-2 J