06-809-006'1-
PLUMBING FIXTURE SCHEDULE
PLUMBING SYMBOL LEGEND
PLUMBING ABBREVIATIONS
GENERAL NOTES
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION STANDARDS.
----"--'- AV ACID VENT
AFF - ABOVE FINISH FLOOR
AW - ACID WASTE
AW -ACID WASTE
2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES.
WC- FLOOR MOUNTED ACCESSIBLE WATER CLOSET
AV - ACID VENT
---- AW---- - BELOW GROUND ACID WASTE
CA - COMPRESSED AIR
3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW
16-1/2" HIGH, VITREOUS CHINA, 1.6 GALLON, FLOOR MOUNTED TANK WATER CLOSET,
CD -ABOVE GROUND CONDENSATE DRAIN
CD -CONDENSATE DRAIN
SURVEYS, AS -BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS
SIPHON JET.
PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON
---- CD —'--- -BELOW GROUND CONDENSATE DRAIN
CFH - CUBIC FEET PER HOUR
DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, A5
SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC WITH STAINLESS STEEL SELF SUSTAINING
CO - CLEANOUT
DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY.
CHECK HINGE, OPEN FRONT LESS COVER.
CA -COMPRESSED AIR
CONT - CONTINUATION
- - DOMESTIC COLD WATER
CW - DOMESTIC COLD WATER
4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS,
1/2" COMPRESSION X 1/2" OD CHROME PLATED ANGLE SUPPLY STOP WITH CHROME
WHICH ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF
PLATED 12" FLEXIBLE RISER AND ESCUTCHEON.
-- - DOMESTIC HOT WATER
DN - DOWN
THE NEW WORK.
DOMESTIC HOT WATER RECIRCULATING
DS - DOWNSPOUT
NOTE: FLUSH HANDLE SHALL FACE WIDESIDE OF STALL
DWG - DRAWING
5. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE.
G - GAS
SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES.
BASIS OF DESIGN
(GREASE)
GR - KITCHEN WASTE GREASE
EXIST -EXISTING
SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR WORKING
T - DEGREE FAHRENHEIT
HOURS.
CHINA - AMERICAN STANDARD - 2998,012
S - ABOVE GROUND SANITARY
FCO -FLOOR CLEANOUT
SEAT - BEMIS - 1655-SS/C
FD - FLOOR DRAIN
6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS
SUPPLY - MCGUIRE - H2169
---- S BELOW GROUND SANITARY
FS
NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY
-FLOOR SINK
ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO
------------- - SANITARY VENT
G - GAS
MAINTAIN CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS
ST - ABOVE GROUND STORM
GPH - GALLONS PER HOUR
AND OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES.
---- ST ----- - BELOW GROUND STORM
GPM - GALLONS PER MINUTE
7. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES.
L-1 ACCESSIBLE WALL HUNG LAVATORY
GR - KITCHEN WASTE (GREASE)
STO - OVERFLOW STORM DRAIN
HB - HOSE BIBB
E. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL
VITREOUS CHINA LAVATORY, 20" X 18", PUNCHED FOR SINGLE HOLE FITTING AND
--- — STO--- - BELOW GROUND OVERFLOW STORM
HD - HUB DRAIN
ROOMS OR AS SPECIFICALLY NOTED.
CONCEALED ARM CARRIER SUPPORT.
v1 - - WATER METER
HW - DOMESTIC HOT WATER
9. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE
4" CENTERSET CHROME PLATED BRASS FAUCET, VANDAL RESISTANT 0.5 GPM FLOW
-li-C -HOSE BIBB OR WALL HYDRANT
HWR -DOMESTIC HOT WATER RECIRCULATING
NON -ACCESSIBLE CEILINGS.
REGULATOR, CHROME PLATED WRISTBLADE HANDLES WITH HOT AND COLD WATER CODED
-
IE INVERT ELEVATION
INDEXES.
COI -CLEAN OUT PLUG
IW - INDIRECT WASTE
10. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND
PRE -INSULATED CHROME PLATED WHEELCHAIR LAVATORY STRAINER, CAST GRID DRAIN
CO H 0 CO - WALL CLEANOUT
KW - KILOWATT
FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR
EXCEED THE RATING OF THE WALL, CEILING OR FLOOR, SEE ARCHITECTURAL DRAWINGS
PLUG WITH STRAINER AND OFFSET DRAIN ASSEMBLY WITH 1-1/4 INCH O.D. TAILPIECE,
� - FLOOR CLEAN OUT
LBS - POUNDS
FOR FINAL FINISHES.
CHROME PLATED 17 GAUGE 1-1/4 X 1-1/2" BRASS P-TRAP WITH CLEANOUT.
-
MH MANHOLE
FD FD �C -FLOOR DRAIN
�
NC - NORMALLY CLOSED
11, FLASH AND COUNTER -FLASH ROOF PENETRATIONS.
PRE -INSULATED 1/2" COMPRESSION X 3/8 INCH COMPRESSION CHROME PLATED ANGLE
(o) - ROOF DRAIN
SUPPLY STOPS WITH CHROME PLATED 12" FLEXIBLE RISERS AND ESCUTCHEONS.
NIC - NOT IN CONTRACT
12. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH
FS � -FLOOR SINK
NO - NORMALLY OPEN
ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER.
FULLY ADJUSTABLE LAVATORY CARRIER ADJUSTED TO ACCESSIBLE HEIGHT, SEE SPECS.
- SHUT-OFF VALVE IN VALVE BOX
NTS -NOT TO SCALE
OD -OUTSIDE DIAMETER
13, PROVIDELOW 1" MINIMUM CLEARANCE
INSIDEApURFACEANDNPIPE
BASIS OF DESIGN
-SHUTOFF VALVE
BETWEEN SLEEVETON
EXTERIOR.
PRV -PRESSURE REDUCING VALVE
CHINA - AMERICAN STANDARD - 0356,012
BALL VALVE
PSI -POUNDS PER SQUARE INCH
14, SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS.
FAUCET - CHICAGO - 602A-317-E2805
CALIBRATED BALANCING VALVE
PVC -POLYVINYL CHLORIDE PIPE
STRAINER/TRAP/STOPS - MCGUIRE - 2125WC
-CHECK VALVE (SWING)
RD -ROOF DRAIN
15. PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEA
CARRIER - ZURN ZR-1200 SERIES
PRESSURE REDUCING VALVE
RPBP - REDUCED PRESSURE BACKFLOW PREVENTOR
16. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES,
S-1 SINK-
SAN - SANITARY
DEVICES, APPLIANCES AND APPARATUS.
- SOLENOID OPERATED VALVE
SD - STORM DRAIN
SINGLE COMPARTMENT SCULLERY SINK CONSTRUCTED OF 14 GAUGE TYPE 304 18-E
�;�+��� ---REDUCED RRESSURE BACKFLOW PREVENTER
SF - SQUARE FEET
17. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED.
STAINLESS STEEL, 72" X 27-1/2" X 14" DEEP WITH a" HIGH FULL LENGTH BACKSPLASH
AND DRAINBOARD ON LEFT AND RIGHT, INTERIOR, TOP SURFACES AND SUPPORT LEGS
- RELIEF OR SAFETY VALVE
SH - SHEET
1E. MOUNT HOSE BIBBS 24" ABOVE FINISHED GRADE.
SHALL BE POLISHED TO A HIGH LUSTER FINISH. PROVIDE SINK WITH CRUMB CUP
ST - STORM
STRAINER.
- GAS COCK
STO - OVERFLOW STORM DRAIN
19. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL
GAS PRESSURE REGULATOR
V - VENT
CLEANOUT WITH COVER FLUSH TO FINISH SURFACE.
E" WIDESPREAD CHROME PLATED BRASS FAUCET, VANDAL RESISTANT 2.0 GPM FLOW
REGULATOR, CHROME PLATED WRIST BLADE HANDLES AND GOOSENECK FAUCET.
FC - SHUTOFF VALVE ON RISER
VAC -VACUUM
20, COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET
VTR - VENT THRU ROOF
FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN.
r-C - GAS COCK ON RISER
CHROME PLATED CAST GRID STRAINER WITH 1-1/2" TAILPIECE, CHROME PLATED 17 GAUGE
- CONNECTION, TOP
WCO - WALL CLEANOUT
21. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.)
1-1/2" BRASS P-TRAP WITH CLEANOUT.
I
WTR -WATER
PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL
- CONNECTION, BOTTOM
T
PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE
1/2" COMPRESSION X 3/8" COMPRESSION CHROME PLATED ANGLE SUPPLY STOPS WITH
C - ELBOW, TURNED DOWN
RE-ROUTED AT NO ADDITIONAL COST.
CHROME PLATED 12" FLEXIBLE RISERS AND ESCUTCHEONS.
- ELBOW, TURNED UP
22. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER
BASIS OF DESIGN
DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE
G-TEE, TURNED UP
FIXTURE.
SINK - ELKAY -WNSF-8124LR
� -TEE, TURNED DOWN
AGO -
FAUCET - CHICAGO-631
23. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL
1
STRAINERS - - 1aB
C -CAP
CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS,
TRAP -MCGUIRE - a
- DIRECTION OF FLOW
ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS
SUPPLIES - MCGUIRE - 2165CC
CONTRACTOR OR FURNISHED BY OTHERS.
e - CONNECT TO EXISTING
- DEMOLISH TO POINT INDICATED
z - REVISION REFERENCE
- DETAIL REFERENCE: TOP -DETAIL#,
BOTTOM -DRAWING# SHOWN ON
PLUMBING DRAWING INDEX
SHEET
DESCRIPTION
ISSUED
P-00
PLUMBING- GENERAL NOTES, LEGEND, SCHEDULE k SHEET INDEX
YES
P-1
PARTIAL FIFTH FLOOR PLAN - PLUMBING
YES
P-2
DETAILS - PLUMBING
YES
TANKLESS ELECTRIC WATER HEATER SCHEDULE
MARK
MANUFACTURER
MODEL
VOLTAGE/PHASE
KW
EWH-1
CHRONOMITE
SR-20L
208/1 0
4.16
NOTES:
1. BASIS OF DESIGN : CHRONOMITE OR EQUAL
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
MG E ARCH IT E C-7 jq
150 Alhambra Circle, Suite 700
Coral Gables, Florida 33134
T.305.444.0413 F.305.441.6404
www. mgea rch itects.com
AA-F000121
CONSULTANTS
5757 Blue Lagoon Dr., #400
Miami, FL 3312Q
Phone: 305-266-6553
0 10 Fax: 305-266-6695
FORCA RE EECTURE www.tic-engineers.com
O Copyright 2005 TLC Engineering for Architecture, Inc.
EB #0000015 TLC NO:606504
DRAWN BY: EMB CHECKED BY: EMB
APPROVED BY: RSM
1007. CONSTRUCTION DOCUMENTS
PROJECT NAME
GARSH
INVESTMENTS
CORPORATE
OFFICES
South Miami, Florida
JOB NUMBER:
2006.000
DATE:
• ♦ ♦
W 40
♦ ♦
"
q0+ A/06
CAD FILE NO:
•
AGENCY NO:
• •
r r ♦ •
REVISIONS/SUBMISSIONS:
0
+ r • r
♦
yr
♦•
••••
/3+••
U
.
Poo*
"
SEAL:
1 i i
� '� try, ••�J C✓J Ir. :, , �
r e (N. 3
Raul S. Mastrapa,\ P.t.
Florida License` #40182
DRAWING TITLE:
GENERAL NOTES
& LEGEND -
PLUMBING
DRAWING NO: P-00