Loading...
06-809-006'1- PLUMBING FIXTURE SCHEDULE PLUMBING SYMBOL LEGEND PLUMBING ABBREVIATIONS GENERAL NOTES SYMBOL DESCRIPTION SYMBOL DESCRIPTION 1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION STANDARDS. ----"--'- AV ACID VENT AFF - ABOVE FINISH FLOOR AW - ACID WASTE AW -ACID WASTE 2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES. WC- FLOOR MOUNTED ACCESSIBLE WATER CLOSET AV - ACID VENT ---- AW---- - BELOW GROUND ACID WASTE CA - COMPRESSED AIR 3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW 16-1/2" HIGH, VITREOUS CHINA, 1.6 GALLON, FLOOR MOUNTED TANK WATER CLOSET, CD -ABOVE GROUND CONDENSATE DRAIN CD -CONDENSATE DRAIN SURVEYS, AS -BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS SIPHON JET. PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON ---- CD —'--- -BELOW GROUND CONDENSATE DRAIN CFH - CUBIC FEET PER HOUR DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, A5 SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC WITH STAINLESS STEEL SELF SUSTAINING CO - CLEANOUT DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY. CHECK HINGE, OPEN FRONT LESS COVER. CA -COMPRESSED AIR CONT - CONTINUATION - - DOMESTIC COLD WATER CW - DOMESTIC COLD WATER 4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, 1/2" COMPRESSION X 1/2" OD CHROME PLATED ANGLE SUPPLY STOP WITH CHROME WHICH ARE TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF PLATED 12" FLEXIBLE RISER AND ESCUTCHEON. -- - DOMESTIC HOT WATER DN - DOWN THE NEW WORK. DOMESTIC HOT WATER RECIRCULATING DS - DOWNSPOUT NOTE: FLUSH HANDLE SHALL FACE WIDESIDE OF STALL DWG - DRAWING 5. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE. G - GAS SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES. BASIS OF DESIGN (GREASE) GR - KITCHEN WASTE GREASE EXIST -EXISTING SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR WORKING T - DEGREE FAHRENHEIT HOURS. CHINA - AMERICAN STANDARD - 2998,012 S - ABOVE GROUND SANITARY FCO -FLOOR CLEANOUT SEAT - BEMIS - 1655-SS/C FD - FLOOR DRAIN 6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS SUPPLY - MCGUIRE - H2169 ---- S BELOW GROUND SANITARY FS NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY -FLOOR SINK ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO ------------- - SANITARY VENT G - GAS MAINTAIN CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS ST - ABOVE GROUND STORM GPH - GALLONS PER HOUR AND OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES. ---- ST ----- - BELOW GROUND STORM GPM - GALLONS PER MINUTE 7. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES. L-1 ACCESSIBLE WALL HUNG LAVATORY GR - KITCHEN WASTE (GREASE) STO - OVERFLOW STORM DRAIN HB - HOSE BIBB E. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL VITREOUS CHINA LAVATORY, 20" X 18", PUNCHED FOR SINGLE HOLE FITTING AND --- — STO--- - BELOW GROUND OVERFLOW STORM HD - HUB DRAIN ROOMS OR AS SPECIFICALLY NOTED. CONCEALED ARM CARRIER SUPPORT. v1 - - WATER METER HW - DOMESTIC HOT WATER 9. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE 4" CENTERSET CHROME PLATED BRASS FAUCET, VANDAL RESISTANT 0.5 GPM FLOW -li-C -HOSE BIBB OR WALL HYDRANT HWR -DOMESTIC HOT WATER RECIRCULATING NON -ACCESSIBLE CEILINGS. REGULATOR, CHROME PLATED WRISTBLADE HANDLES WITH HOT AND COLD WATER CODED - IE INVERT ELEVATION INDEXES. COI -CLEAN OUT PLUG IW - INDIRECT WASTE 10. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND PRE -INSULATED CHROME PLATED WHEELCHAIR LAVATORY STRAINER, CAST GRID DRAIN CO H 0 CO - WALL CLEANOUT KW - KILOWATT FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR EXCEED THE RATING OF THE WALL, CEILING OR FLOOR, SEE ARCHITECTURAL DRAWINGS PLUG WITH STRAINER AND OFFSET DRAIN ASSEMBLY WITH 1-1/4 INCH O.D. TAILPIECE, � - FLOOR CLEAN OUT LBS - POUNDS FOR FINAL FINISHES. CHROME PLATED 17 GAUGE 1-1/4 X 1-1/2" BRASS P-TRAP WITH CLEANOUT. - MH MANHOLE FD FD �C -FLOOR DRAIN � NC - NORMALLY CLOSED 11, FLASH AND COUNTER -FLASH ROOF PENETRATIONS. PRE -INSULATED 1/2" COMPRESSION X 3/8 INCH COMPRESSION CHROME PLATED ANGLE (o) - ROOF DRAIN SUPPLY STOPS WITH CHROME PLATED 12" FLEXIBLE RISERS AND ESCUTCHEONS. NIC - NOT IN CONTRACT 12. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH FS � -FLOOR SINK NO - NORMALLY OPEN ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER. FULLY ADJUSTABLE LAVATORY CARRIER ADJUSTED TO ACCESSIBLE HEIGHT, SEE SPECS. - SHUT-OFF VALVE IN VALVE BOX NTS -NOT TO SCALE OD -OUTSIDE DIAMETER 13, PROVIDELOW 1" MINIMUM CLEARANCE INSIDEApURFACEANDNPIPE BASIS OF DESIGN -SHUTOFF VALVE BETWEEN SLEEVETON EXTERIOR. PRV -PRESSURE REDUCING VALVE CHINA - AMERICAN STANDARD - 0356,012 BALL VALVE PSI -POUNDS PER SQUARE INCH 14, SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. FAUCET - CHICAGO - 602A-317-E2805 CALIBRATED BALANCING VALVE PVC -POLYVINYL CHLORIDE PIPE STRAINER/TRAP/STOPS - MCGUIRE - 2125WC -CHECK VALVE (SWING) RD -ROOF DRAIN 15. PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEA CARRIER - ZURN ZR-1200 SERIES PRESSURE REDUCING VALVE RPBP - REDUCED PRESSURE BACKFLOW PREVENTOR 16. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, S-1 SINK- SAN - SANITARY DEVICES, APPLIANCES AND APPARATUS. - SOLENOID OPERATED VALVE SD - STORM DRAIN SINGLE COMPARTMENT SCULLERY SINK CONSTRUCTED OF 14 GAUGE TYPE 304 18-E �;�+��� ---REDUCED RRESSURE BACKFLOW PREVENTER SF - SQUARE FEET 17. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. STAINLESS STEEL, 72" X 27-1/2" X 14" DEEP WITH a" HIGH FULL LENGTH BACKSPLASH AND DRAINBOARD ON LEFT AND RIGHT, INTERIOR, TOP SURFACES AND SUPPORT LEGS - RELIEF OR SAFETY VALVE SH - SHEET 1E. MOUNT HOSE BIBBS 24" ABOVE FINISHED GRADE. SHALL BE POLISHED TO A HIGH LUSTER FINISH. PROVIDE SINK WITH CRUMB CUP ST - STORM STRAINER. - GAS COCK STO - OVERFLOW STORM DRAIN 19. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL GAS PRESSURE REGULATOR V - VENT CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. E" WIDESPREAD CHROME PLATED BRASS FAUCET, VANDAL RESISTANT 2.0 GPM FLOW REGULATOR, CHROME PLATED WRIST BLADE HANDLES AND GOOSENECK FAUCET. FC - SHUTOFF VALVE ON RISER VAC -VACUUM 20, COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET VTR - VENT THRU ROOF FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN. r-C - GAS COCK ON RISER CHROME PLATED CAST GRID STRAINER WITH 1-1/2" TAILPIECE, CHROME PLATED 17 GAUGE - CONNECTION, TOP WCO - WALL CLEANOUT 21. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) 1-1/2" BRASS P-TRAP WITH CLEANOUT. I WTR -WATER PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL - CONNECTION, BOTTOM T PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE 1/2" COMPRESSION X 3/8" COMPRESSION CHROME PLATED ANGLE SUPPLY STOPS WITH C - ELBOW, TURNED DOWN RE-ROUTED AT NO ADDITIONAL COST. CHROME PLATED 12" FLEXIBLE RISERS AND ESCUTCHEONS. - ELBOW, TURNED UP 22. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER BASIS OF DESIGN DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE G-TEE, TURNED UP FIXTURE. SINK - ELKAY -WNSF-8124LR � -TEE, TURNED DOWN AGO - FAUCET - CHICAGO-631 23. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL 1 STRAINERS - - 1aB C -CAP CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS, TRAP -MCGUIRE - a - DIRECTION OF FLOW ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS SUPPLIES - MCGUIRE - 2165CC CONTRACTOR OR FURNISHED BY OTHERS. e - CONNECT TO EXISTING - DEMOLISH TO POINT INDICATED z - REVISION REFERENCE - DETAIL REFERENCE: TOP -DETAIL#, BOTTOM -DRAWING# SHOWN ON PLUMBING DRAWING INDEX SHEET DESCRIPTION ISSUED P-00 PLUMBING- GENERAL NOTES, LEGEND, SCHEDULE k SHEET INDEX YES P-1 PARTIAL FIFTH FLOOR PLAN - PLUMBING YES P-2 DETAILS - PLUMBING YES TANKLESS ELECTRIC WATER HEATER SCHEDULE MARK MANUFACTURER MODEL VOLTAGE/PHASE KW EWH-1 CHRONOMITE SR-20L 208/1 0 4.16 NOTES: 1. BASIS OF DESIGN : CHRONOMITE OR EQUAL NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT MG E ARCH IT E C-7 jq 150 Alhambra Circle, Suite 700 Coral Gables, Florida 33134 T.305.444.0413 F.305.441.6404 www. mgea rch itects.com AA-F000121 CONSULTANTS 5757 Blue Lagoon Dr., #400 Miami, FL 3312Q Phone: 305-266-6553 0 10 Fax: 305-266-6695 FORCA RE EECTURE www.tic-engineers.com O Copyright 2005 TLC Engineering for Architecture, Inc. EB #0000015 TLC NO:606504 DRAWN BY: EMB CHECKED BY: EMB APPROVED BY: RSM 1007. CONSTRUCTION DOCUMENTS PROJECT NAME GARSH INVESTMENTS CORPORATE OFFICES South Miami, Florida JOB NUMBER: 2006.000 DATE: • ♦ ♦ W 40 ♦ ♦ " q0+ A/06 CAD FILE NO: • AGENCY NO: • • r r ♦ • REVISIONS/SUBMISSIONS: 0 + r • r ♦ yr ♦• •••• /3+•• U . Poo* " SEAL: 1 i i � '� try, ••�J C✓J Ir. :, , � r e (N. 3 Raul S. Mastrapa,\ P.t. Florida License` #40182 DRAWING TITLE: GENERAL NOTES & LEGEND - PLUMBING DRAWING NO: P-00