Loading...
06-809-005411 CEILING --=PLAN LEGEN[:F INDICATES GYPSUM BOARD HEADER OVER OPENING INDICATES GYPSUM BOARD SOFFIT OR CEILING INDICATES GYPSUM BOARD SOFFIT x WITH OVERHEAD CABINETS. (SEE INTERIOR ELEVATIONS) INDICATES ACOUSTICAL TILE CEILING SYSTEM. 2x4 FLUORESCENT LIGHT FIXTURE 2x2 PARABOLIC FLUORESCENT LIGHT FIXTURE �] 2LIGHTx2 FIXTURE DI REDIRECT FLUORESCENT EGG CRATE FLUORESCENT - LIGHT FIXTURE PENDANT FLUORESCENT Lull �� DIRECT/INDIRECT LIGHT FIXTURE WALL WASH COVE LIGHT FIXTURE DECORATIVE CHANDELIER LIGHT FIXTURE FO-0-01 3 COMBO LIGHT FLUORESCENT STRIP LIGHT IN COVE FLUORESCENT LIGHT STRIP SM SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE SURFACED MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE (HATCHING DENOTES DIRECTIONAL LIGHT) 4' (2 BULB) EXPOSED ........................................... FLUORESCENT O SURFACE MOUNTED DECORATIVE LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE AND + ELEVATION ABOVE FINISH FLOOR • OPENDANT LIGHT FIXTURE SD SMOKE DETECTOR (SEE FIRE PROTECTION DRAWINGS) FIRE ALARM SPEAKER (SEE FIRE PROTECTION DRAWINGS) O SPRINKLER HEAD (SEE FIRE PROTECTION DRAWINGS) Q WALL MOUNTED SPRINKLER HEAD (SEE FIRE PROTECTION DRAWINGS) FIRE ALARM LIGHT l Y (SEE FIRE PROTECTION DRAWINGS) e EXIT LIGHT (HATCH DENOTES LIGHTED FACE) (SEE ELECTRICAL DRAWINGS) ®} DIRECTIONAL EXIT LIGHT tl (HATCH DENOTES LIGHTED FACE) (SEE ELECTRICAL DRAWINGS) A/C SUPPLY DIFFUSER (SEE MECHANICAL DRAWINGS) A/C RETURN GRILLE (SEE MECHANICAL DRAWINGS) AIR EXHAUST GRILLE (SEE MECHANICAL DRAWINGS) CEILING ACCESS PANEL 1 SOFFIT DETAIL SYMBOL A2.34 W/ DRAWING AND SHEET NUMBERS REVISION SYMBOL 3 (REFER TO COVER SHEET FOR REVISION INFORMATION) CEILING NOTES 1. COORDINATE ALL CEILING FIXTURES SHOWN ON CEILING PLAN WITH FIRE PROTECTION AND ELECTRICAL DRAWINGS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION BEFORE PROCEEDING WITH WORK. 2. SPRINKLER HEADS ARE SHOWN TO INDICATE THEIR LOCATION ON THE CEILING. SEE FIRE PROTECTION DRAWINGS FOR ALL INFORMATION REQUIRED TO COMPLETE THE WORK. 3. A/C SUPPLY, A/C RETURN AND AIR EXHAUST REGISTERS ARE SHOWN TO INDICATE THEIR LOCATION ON THE CEILING. SEE MECHANICAL DRAWINGS FOR ALL INFORMATION REQUIRED COMPLETE THE WORK. 4. GYPSUM BOARD SOFFIT ABOVE CABINETS TO BE 7'-2' ABOVE FINISH FLOOR (A.F.F.) UNLESS OTHERWISE NOTED IN PLANS OR ELEVATIONS. 5. HEADERS SCHEDULED TO BE AT 7'-2' ABOVE FINISH FLOOR (A.F.F.) UNLESS OTHERWISE NOTED IN PLANS OR ELEVATIONS. I. SEE ELECTRICAL DRAWINGS FOR LIGHTING IN AREAS INDICATING EXPOSED STRUCTURE. 7. CONTRACTOR SHALL PROVIDE CEILING ACCESS PANELS AT GYPSUM BOARD CEILINGS AS REQUIRED TO SERVICE ALL CONCEALED DAMPERS AND CONTROL VALVES. SEE MECHANICAL AND PLUMBING DRAWINGS. a. ALL ELEVATIONS INDICATED IN CEILING PLANS TO BE ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED ON PLANS. 9. COORDINATE ALL CEILING PLAN ELEVATIONS WITH DETAILS AND/OR INTERIOR ELEVATIONS. CONTACT ARCHITECT IF ANY DISCREPANCIES ARE FOUND BEFORE PROCEEDING WITH WORK. 10. ALL CEILINGS TYPICAL 9'-0' A.F.F. U.O.N. MGE ARCH TEC-S 150 Alhambra Circle, Suite 700 Coral Gables, Florida 33134 T.305.444.0413 F.305.441.6404 www.mgearchitects.com AA-F000121 PROJECT NAME GARSH INVESTMENTS CORPORATE OFFICES South Miami, Florida JOB NUMBER: 2006.010 DATE: 04/24/06 CAD FILE NO: AGENCY NO: REVISIONS/SUBMISSIONS: ZL BLDG. DEPT. COMMENTS AND COORD. 2 09/18/06 A Z Q A A SEAL: � i r .ti v, 4t� l .' t / ❑ PEDRO 'GOICOURIA, AIA AR-0005779 © DOSE L. ESTEVEZ, AIA AR-0008493 ❑ ROLANDO CONES& AIA AR-0011748\ ❑ ROBERTO A. SMITH, AIA AIA-0010466 DRAWING TITLE: FIFTH FLOOD CEILING PLAN FIFTH FLOOR CEILING PLAN 114V -1'-0" 1 DRAWING NO: A6.0