6387 SW 69 ST EB-09-051-002 1 2 3 4 5 6 7
A B C D
19'-9" 221-71' 26'-2"
I I
1 I
I I
i � I
3" insulated steel wall panels, '
36" coverage, typ.
1
1 , ,
------------
-------, --------+- ---------------------------------------------------------------------------- -----,
I
1 I I 2
A5
5 '
H 71
------------- -------
------------------ ------------'------------- 1 I
I
telescoping glass doors at
Courtyard ; O
1
1 I CLL I I 1
i i I
I i I 1 I N ' , I I , , I ,
O '
Living Room --� Family Room
I
N
Bath 4
"
1 1 +0 1
I
ourtya B
B � stained concrete floor (slab on ;
4 +0" grade) throughout fi t floor
_____________________1________-________ ________- ____----________-
I I 1 I
I i -
stained concrete floor (slab on
grade) throughout first floor CC ti BB
CO
- I � o
I 1 I Z
i 1 I I
(D
do 4'-6" 4 7 8"::%4'-9 1/8" 16'-6" N
structural steel as noted on
ti O
structural drawings (note: size —'
1 and position of all steel ; ; CG ; r,
1
N ' members to be determined by O
' structural engineer)
Q � cu
PAI I ' Q In
iio Dining Room 1 I
+0" H Bedroom 4 4 0
�1 +0„ '
1 I r
1 I � o
' ------------------------- _ -- __ -- - ----- --- --------------------------------- _ '
____________ _________i--_______-_______ ___--_____
I I Z
( i 1 1
1 i EE 1 1 I !
1 1 I I
• 1 ' 1 I 1 �+
1 1 1 I� I I N
A mechanical loft above i i - mechanical loft above - o 0 v E o
1 ; itch en zo cfl 01 yc► o (/1
OD 00
i 1 I 1
oft
-----------, �
1 N
-' ------------ --------- ---+ d i
0 ' i area reserved for equipment: inverter, controller g
1— o o i lazed overhead ro#I�n ara 1 i #} system; o a
2 � g________-_ g� .._���°°r��' ���hunter hei ht � and batteries far photovoltaic s tem; reverse ,
I
Bath 1 Lavato - --- - osmosis, charcoal and UV tight filters for rainwater
I
' +0" +0" system; storage tank for solar hot water system; ;
I
filtration tank for graywater system; air handler far; F � � L
I C
—
i - ------ - - - -- - ---- ------------------------
------------ --- --------------------------------- - i
� CO � H VAC system �
2 --------------------------------- -- ----------- ---- -------------------------------
;----- --- - - -�- �`
- - I 1
, + G�1 Z
i I �
D-0 Laund o mechanical loft above i `. rainwater cistern IV a r
9'-5 5/8" Z 7/8 5'-0" 4 8'-0 1/4" 4 7/8' 9'-9" 4 7/8' ° 8'-7 1/4"
4 a
2'-4 7/
1
OD
I �
ao M Bat h2 Bath 3 LP gas tank
M aD +0" '
Bedroom 1 o +0
+0" 0 cs�
O ( S '�` hvac equipment C
ara e > r_ U
+0" above grade, slope to driveway � d ch #-' W
co I -
Co Co +
\ I
1
� 3" insulated steel wall panels, N t/3 M
M , ' 36" coverage, typ.
D I N
Interior walls to be 5/8"GWB
wer 3 5/8" metal studs at 16"
7 '\_T NV
- g _ O.C.
------------------------- -----------------------------------
1 }
p
overhead rolling garage door
I I � �
I
1 1
!A
Porch �- Bedroom 2 Bedroom 3 1 1 ``mss �►
1
-3" +0}� +0" '
1
1
1 1 tU
I �_ �� ! �_ !r T ; ' I i_
12'-4 1/4" 4 7/81' 11 10 5/8 4 7/8 1 24'-2 3/8" 1 1
1 � L C
.1-� iCI
------------------------------ --- ------ -- ----------------------- ' d7 E s-
I '73 4p ,♦� O
04 05 C 4 cc 'S �L
I �, O ' = _I
---- 19-5 3/4
M U_
V CMO
N � E
E � g
70'-t3"
Scale
• Sheet Scale
Drawing Mo.
- A-01
Floor Plan
1 Note: see A-06 for interior elevations and finish schedules. of
Scale: 1/4" = V-0"
1
2 3 4 5 6 7