06-697-002r- w y I SECOND - FIFTH FLOOR (TYPICAL) PERMIT AREA ONLY E.O.L. vw_ NAC #1 (1.542 amp, 3.0 max) Fire Alarm System Riser N.T.S. STYLE "Y" n 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd N N N N N ,N N N N L L L H L H L H L H138 H137 H136 H135 H134 H133 H132 H131 H130 NEW SK"5495" AUX. POWER SUPPLY LOCATED IN NEW RESTAURANT. P5 A D FtC SENN _ C5 120V DEDICATED CIRCUIT TO ELECT J C PANEL WITH 2OAmp CIRCUIT BREAKER. B E.O.L. E E V E E H L H L EXISTING BPS-10 BOOSTER - P2 POWER SUPPLY LOCATED IN D :V ELECT. ROOM. B.P.S #1 C 120V DEDICATED CIRCUIT TO ELECT E PANEL WITH 2OAmp CIRCUIT BREAKER. FIRST FLOOR WIRE LEGEND SYMBOL WIRE TYPE AND DESCRIPTION A 18-2 FPLP FOR SIGNALING LINE CIRCUIT B 14-2 FPLP WIRE FOR NOTIFICATION APPLIANCE CIRCUITS C 12 AWG THHN WIRE FOR APS & FACP POWER D 12 AWG THHN WIRE FOR APS & FACP_ GROUND EXISTING EST-2 FIRE ALARM CONTROL PANEL LOCATED IN LOBBY. STYLE "4" SECOND - FIFTH FLOOR (TYPICAL) PERMIT AREA Ol`NLY D10 D111 LL 0 E P N O N D5 SD E E N E E E E 81 120V BELL WITH SIGN TS FS BF R E E E E: A MAGNETIC LOCK TO FACP \pR ATTACHED TO FACP E A D F.A.C.P. TELCO LINES FOR REMOTE TO FACP-- E P1 E STATION NOTIFICATION R - E C 120V DEDICATED CIRCUIT TO ELECT OC PANEL WITH 2OAmp CIRCUIT BREAKER. FIRST FLOOR Fire Alarm Control Panel EST Model: STANDBY DESCRIPTION CURRENT PER UNIT (Amp) EST2 CITY TOTAL STANDBY CURRENT (Amp) ALARM CURRENT PER UNIT (Amp) �• TOTAL ALARM CITY CURRENT (Amp) Main Board 0.147 X 1 = 0,147 0.216 X 1 = 0.2160 Addressable Photoelectric Smoke Detector (SIGA-PS) 0.000045 X 27 = 0.001215 0,000046 X 27 = 0.0012 Addressable Heat Detector (SIGA-HRS) 0.000045 X 4 = 0,00018 0.000045 X 4 = 0.0002 Addressable Duct Detector (SIGA-PS) 0,000045 X 6 = 0.00027 0.000045 X 6 = 0.0003 Addressable Pulh Station 0.000260 X 15 = 0.00375 0,0004 X 15 = 0.0060 Elevator Warning Light 0,000000 X 2 = 0.0000 0.0200 X 2 = 0.0400 Addressable Monitor Module (SIGA-CT1) 0.000250 X 9 = 0.00225 0.0004 X 9 = 0,0036 Addressable Dual Monitor Module (SIGA-WTM) 0,000396 X 5 = 0.00198 0.00068 X 5 = 0.0034 Addressable Control Module (SIGA-CC1) 0.000223 X 8 -IX0.0008 0.001784 0.00010 8 Addressable Relay SIGA-CR 0.000100 X 1 7 = 0.0007 0.000100 X 7 = 0.0007 0.159 0.2722 2 Hour Fire Rated Through Penetration Firestop for Multiple Metal Pipe through 3733 Green Rd. Concrete floors or walls Beachwood, OH, 44122 using FYRE-SHIELD. e� Drawing not to stale CAJ1047 F-rating = 2 Hr. (326) T-rating - 0 Hr. 1D Floor or Wall assembly = 4 " thick concrete, Max. area of opening is 288 sq. in. ® -Copper Pipe: 4" dia. (or smaller) regular (or heavier) copper. -Steel Pipe: 8" dia. (or smaller) Sch.40 (or heavier) steel. -Conduit: 4" dia. (or smaller) EMT or 6" dig. (or smaller) steel conduit. -Copper Tubing: 4" dia.(or smaller) Type L(or heavier) copper. -Iron Pipe: 8' dia.(or smaller) cast or ductile iron. -Max. number of pipes with opening is three (3). (3 A) Forming Material - (Not shown) - Nom. 1" thick poly- urethane backer rod friction fitted into opening. B) Nom. 3" FYRE-SHIELD thickness installed within opening. NOTE: For wall apply FYRE-SHIELD to both surfaces of wail. Project: ibs p.oduct• uad b ih• abo» 0"wo, ho. 1bn dto s dawE•d awmbly me 1 bwa tatwd G a dance with tb• fdfowin9 pprroo�d�eb have ban G.GO and we • AS711 E51d (U1.747s) St=M tat Method bo.}/ an bop D m� mactpotN Location: for mrou9 k.411 .11 FFatoppin4 D�rramana wn ,x wild not be tlablo ra1 any dgmogM d4at Instorer. mtaWo4�adupi-.e trtan�oo Dots: 5/1/95 -7wing: TR-1a47 d,ae aniy w rwpan.bi fw ry(oa(ne Signature [Approved b , C. TutteO moE,rid rouse Ee a ar«a. SOLID, AWG 14: _ 20.4 Ohms er 1000 End Of Battery Life (Volts) Max Ca acity (Amp) N Device # Device Description Ala Curl A H130 Strobe 75cd 0.165 H131 Horn /Strobe 75cd 0.184 C H 132 Strobe 75cd 0.165 # H133 Horn lStrobe 75cd 0.184 H134 Strobe 75cd 0.165 H135 Horn /Strobe 75cd 0.184 H136 Strobe 75cd 0.165 H 137 Strobe 75cd 0' 165 H138 Strobe 75cd 0.165 1.542 AUX. POWER SUPPLY "SK 5495" 3, } Distance Applied Voltage Drop Voltage �. 6 Feet 20.343 Volts 0.057 Volts �. 27 Feet 20,115 Volts 0,228 Volts >. 14 Feet 20.012 Volts 0.103 Volts >. 38 Feet 19.773 Volts 0.240 Volts >. 22 Feet 19,659 Volts 0.114 Volts >. 1 Feet 19.654 Volts 0.004 Volts 1.L10 Feet 19,624 Volts 0.030 Volts >. 22 Feet 19.579 Volts 0.045 Volts r. 1 Feet 0.001 Volts STROBE OR HORN/STROBE 80' A.F.F. OR 6' BELOW CEILING (WHICHEVER IS LOWER) PULL STATION 48' A.F.F. ADA HEIGHT REQUIREMENTS NO SCALE ALLOWABLE AMPACITY FOR COPPER y r WIRES SIZE ALLOWABLE AMPACITY 18 6 16 8 14 15 12 20 10 30 FROM NEC -TABLE 310-16 & 402-5 IFME ALARM SYSTEM TO 13E- INSTALLED IN ACCORDANCE, WITH NFPA 72 70;101- APPRQVED N AINII-DADE COUNTY FIRE DEPARTNT BLDG, PERMIT FIRE ALARM FIRE SUPPRESSION .WATE MAIN EXT. bAT E: Em REVISION: FIRE DEP TMEN 03/22/06 fi 7 rl- LO -<� n N ,It E-4 I Q'"' C�YJ P-+-1 ® Q C Q E4 ® O E: 4 1Z w C) E__4_ • 4` "'.off°,i'.�..; n`ii� `'•• ,^. PROJECT NO.: DRAWING NO.: SCALE: N. DATE:. 02/1,/�6.. DOAYr" YV�1;�8 . „ ISSUED: FOR PERMIT