PLUMBING FIXTURE SCHEDULE
SYMBOL
FIXTURE TYPE
TRAP
C.W.
H.W.
DESCRIPTION
KS
KITCHEN SINK
2'
1/2,
liz'
REP.
REP. ICE MAKER
-
'/z'
-
DA
N.T.3
�MO ll��
Ae
ACT
CHANDLER AND ASSOCIATES
ARCE11TECTURK PA
AA 0003050
JASON IL CHAML K AIA AR NQ 16M
SOUTH MIAMI, FLORIDA 33143
TEL (M 669-7992
FAX (M 669-7593
WWW.CHANDLERAR COM
oorrxxw Boa
j
PLUMBING No'rES
1.0 GENERAL
1.1 PROVIDE ( FURNISH AND INS_' L ) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
1.2 SCOPE OF WORK :
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY COLLECTION.
B. HOT AND COLD WATER SUPPLY.
C. AIR CONDITIONING CONDENSATE.
D. ROOF DRAINAGE.
1.3 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED.
1.4 VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATION OR INSTALLATION. COORDINATE REQUIREMENTS
TO AVOID INTERFERENCE WITH OTHER TRADES.
1.5 SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
1.6 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
2.0 MATERIALS
2.1 PROVIDE SHUT-OFF VALVES FOR EACH FIXTURE AND
WATER HAMMEL ARRESTOR WHERE SHOWN AND WHERE
REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM.
2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND
FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM
PIPING AND SLABS TO PREVENT CORROSION.
2.3 PIPING
2.3.1 DOMESTIC HOT AND COLD WATER: COPPER TUBING TYPE
"K" OR "L" WITH SOLDER JOINTS. WOG BRONZE VALVES
125 P.S.I. MIN. PROVIDE PRE -MOLDED FIBERGLASS
INSULATION FOR HOT WATER LINES.
2.3.2 SANITARY WASTE, VENT, AND ROOF DRAINAGE CAST IRON PIPING
NO -HUB
2.3.3 A/C CONDENSATE:
GROUND LEVEL
15ULDING PLAN,
ABOVE FLOOR: COPPER D.W.V. PIPE WITH ARMFLEX INSULATION.
BELOW FLOOR: PVC SCHEDULE 40 AND FITTINGS.
INSULATE ALL OVERHEAD HORIZONTAL RUNS WITH 1 /2" ARMFLEX
INSULATION.
THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW. THEY ARE
NOT TO BE CONSTRUED AS FINAL CONSTRUCTION DOCUMENTS
UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED AND
COMMENTS INCORPORATED INTO THESE DWGS. DUE TO THE
VARIATIONS IN INTERPRETATIONS OF THE CODE THAT OCCUR IN
DIFFERENT MUNICIPALITIES FINAL APPROVAL AND REVIEW IS NEEDED
TO ASSURE COMPLIANCE WITH THE APPLICABLE CODES AND
STANDARDS.
DRAINWQ TITLE:
FEVk ION
PLUMBMN
PARTIAL MCE PLAN
SWE 120
DATE SOXC.D 12-WO5
• ; '.; `•: ,< 5 ` • ` ' ' PROJECT Na 2004.23
DRAY IM Na
P-1
�,� fiJ 1• � rl`�� 1