Loading...
06-1147-008TIE IN TO EXISTING (TYP.) 2 EXISTING WET COLUMN: --' —3"VENT. STUB UP —3/4'CW STUB UP FLOOR PLAN- PLUMBING SCALE 1/4" = 1'-0" N �— EXISTING WET COLUMN: 3"VENT. STUB UP TIE IN TO EXISTING (TYP.) 2" NEW 2" VENT PIPE NEW 3"01/8"/FT-9 FU - EXISTING 4"SAN MAIN LINE FIELD VERIFY EXACT LOCATION 1/2"TRAP RESEAL ,-3"(9 FU) P-1H /-3" 3" GENERAL PLUMBING NOTA- 1. A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with oil applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the plumbing work. C. ARRANGE AND PAY for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and/or improper workmanship for a minimum of one year for material and labor. E. ALL HORIZONTAL SANITARY PIPING 3" and larger shall slope at 1/8 inch per foot minimum, unless noted otherwise. All piping 2" and smaller shall slope at 1/4" per foot minimlum. 2. PLUMBING FIXTURES: Fixtures shall be as specified and shall be furnished and installed by this contractor. Fixtures shall be complete with drains, traps, supplies and any other accessory required. 3. MATERIALS: A. PIPINGG a. Soil, waste and vent, and storm: PVC, DWV Sch.40 cost iron pipe fittings. b. Domestic water: Copper pipe, Type L with sweat wrought copper fittings. Type "M" in concealed spaces is acceptable. Isolate piping from concrete with insulating material. cpvc in apartments water distribution is acceptable as per owners request. fittings in a/c closets. d. Domestic water supply assembly. Chrome finish tubing with angle shut off valves. 5. VALVES: Domestic water valves shall be of bronze body, sweat ends. 6. CONTRACTOR SHALL COORDINATE exact location of sanitary, and domestic water piping before starting any work. Notify Architect/Engineer of any deviations from design drawings. 7. SAW OR CUT CORE DRILL slob as required to install new plumbing work. Patch slab to match existing and seal all penetrations to maintain fire rating of floor. DRAIN SCHEDULE SYMBOL SERVICE MANUFACTURER/MODEL FD FLOOR DRAIN JOSAM, 3000OA-5S-2-50-80 EXISTING WET COLUMN: 3/4"CW STUB UP EXISTING 3/4"CW STUB UP CO TIE IN TO EXISTING (TYP.) f3/4" NEW 3/4"CW LINE IN CLG SPACE \� P-1H A'rE R PIS SOME'r ,� PLUMBING SYMBOL LEGEND l SANITARY LINE VENT LINE COLD WATER LINE EXISTING SANITARY PIPE EXISTING COLD WATER LINE EXISTING VENT LINE -v"r- GATE VALVE FLOOR PENETRATION FD FLOOR DRAIN WATER HAMMER ARRESTOR WCO WALL CLEANOUT VTR VENT THRU ROOF COOG CLEANOUT ON GRADE ® TIE—IN TO EXISTING PIPE 001 I PERFORATED VENT CAP 12' MIN. SLOPE 1/$'/ FT. AC UNIT 3' 3/4' UNION CONDENSATE TRAP DETAIL PLUMBING FIXTURE CONNECTION SCHEDULE NO. DESCRIPTION DRAIN WATER REMARKS COLD HOT P-1H WATER CLOSET HC FLOOR TANK TYPE. 3" 1/2' -- BY OWNER/ARCH P-2H LAVATORY (WALL HUNG) HC 1 1/2" 1/2' -- BY OWNER/ARCH NOTES: 1. ALL FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE WATER CONSERVATION STANDARDS. LAVATORY WASTE LAVATORY CHROME PLATED SUPPLY (SPEED WAY OR EQUAL) CHROME PLATED ESCUTCHEON FILL LINE MUST SLOPE TO TRAP FLOOR DRAIN TRAP RESEAL DETAIL N.T.S. SH FLOOR PRIMER 3/4" 1/2" 1/2-TRAP RESEAL n u_ W 11.1 0 0 w w > > m m Z 2 U) w m O � w w d Z o� m 0 a N� �W L W Z Z0 r� V Z w Z Z O CL ZJ ` w CL Z M_ ® CL c1 o Z It O J WW w J m ® � U tt1�1 V O v Ww z Jw F_ � a 0o T� Mr o J L.L rn co N� LIC. AA 260DO897 O M 'ftI M • Q 0 LL p/ 0 Z f J 0 n. V I 'w J CL _ WE N� z Q re X� f� ( or. 'fuei�t I 7'F Consulting Engineers Inc. MECHANICAL - PLUMBING - ELECTRICAL 9520 S.W. 40 St. Suite # 207 - MIAMI FLORIDA 33165 OFFICE (305) 225-8377 - FAX 305-225-8378 SHEET NO.: P-1