06-1147-008TIE IN TO EXISTING
(TYP.)
2
EXISTING WET COLUMN: --'
—3"VENT. STUB UP
—3/4'CW STUB UP
FLOOR PLAN- PLUMBING
SCALE 1/4" = 1'-0"
N
�— EXISTING WET COLUMN:
3"VENT. STUB UP
TIE IN TO EXISTING
(TYP.)
2"
NEW 2"
VENT PIPE
NEW 3"01/8"/FT-9 FU -
EXISTING 4"SAN MAIN LINE
FIELD VERIFY EXACT LOCATION
1/2"TRAP RESEAL
,-3"(9 FU)
P-1H /-3"
3"
GENERAL PLUMBING NOTA-
1. A. ALL WORK SHALL BE DONE in accordance with the Florida
Building Code and with oil applicable regulations.
B. DRAWINGS: Refer to all drawings for coordination of the
plumbing work.
C. ARRANGE AND PAY for all permits, licenses, inspections
and tests. Obtain the required certificates and present
to owner.
D. GUARANTEE: The completed installation shall be fully
guaranteed against defective materials and/or improper
workmanship for a minimum of one year for material and
labor.
E. ALL HORIZONTAL SANITARY PIPING 3" and larger shall slope
at 1/8 inch per foot minimum, unless noted otherwise.
All piping 2" and smaller shall slope at 1/4" per foot
minimlum.
2. PLUMBING FIXTURES: Fixtures shall be as specified
and shall be furnished and installed by this contractor.
Fixtures shall be complete with drains, traps, supplies and
any other accessory required.
3. MATERIALS:
A. PIPINGG
a. Soil, waste and vent, and storm: PVC, DWV Sch.40
cost iron pipe fittings.
b. Domestic water: Copper pipe, Type L with sweat wrought
copper fittings. Type "M" in concealed spaces is
acceptable. Isolate piping from concrete with insulating
material. cpvc in apartments water distribution is
acceptable as per owners request.
fittings in a/c closets.
d. Domestic water supply assembly. Chrome finish tubing
with angle shut off valves.
5. VALVES: Domestic water valves shall be of bronze body,
sweat ends.
6. CONTRACTOR SHALL COORDINATE exact location of sanitary,
and domestic water piping before starting any work. Notify
Architect/Engineer of any deviations from design drawings.
7. SAW OR CUT CORE DRILL slob as required to install new plumbing work.
Patch slab to match existing and seal all penetrations to maintain fire
rating of floor.
DRAIN SCHEDULE
SYMBOL
SERVICE
MANUFACTURER/MODEL
FD
FLOOR DRAIN
JOSAM, 3000OA-5S-2-50-80
EXISTING WET COLUMN:
3/4"CW STUB UP
EXISTING 3/4"CW STUB UP
CO TIE IN TO EXISTING
(TYP.)
f3/4"
NEW 3/4"CW LINE IN CLG SPACE \�
P-1H
A'rE R PIS SOME'r ,�
PLUMBING SYMBOL LEGEND
l
SANITARY LINE
VENT LINE
COLD WATER LINE
EXISTING SANITARY PIPE
EXISTING COLD WATER LINE
EXISTING VENT LINE
-v"r-
GATE VALVE
FLOOR PENETRATION
FD
FLOOR DRAIN
WATER HAMMER ARRESTOR
WCO
WALL CLEANOUT
VTR
VENT THRU ROOF
COOG
CLEANOUT ON GRADE
®
TIE—IN TO EXISTING PIPE
001
I
PERFORATED
VENT CAP 12' MIN.
SLOPE 1/$'/ FT. AC UNIT
3'
3/4' UNION
CONDENSATE TRAP DETAIL
PLUMBING FIXTURE CONNECTION SCHEDULE
NO.
DESCRIPTION
DRAIN
WATER
REMARKS
COLD
HOT
P-1H
WATER CLOSET HC
FLOOR TANK TYPE.
3"
1/2'
--
BY OWNER/ARCH
P-2H
LAVATORY (WALL HUNG) HC
1 1/2"
1/2'
--
BY OWNER/ARCH
NOTES: 1. ALL FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE WATER CONSERVATION STANDARDS.
LAVATORY WASTE
LAVATORY
CHROME PLATED
SUPPLY (SPEED WAY
OR EQUAL)
CHROME PLATED
ESCUTCHEON
FILL LINE MUST
SLOPE TO TRAP
FLOOR DRAIN
TRAP RESEAL DETAIL N.T.S.
SH FLOOR
PRIMER
3/4"
1/2"
1/2-TRAP RESEAL
n
u_
W
11.1
0
0
w
w
>
>
m
m
Z
2
U)
w
m
O
�
w
w
d
Z
o�
m
0
a
N�
�W
L
W
Z
Z0
r�
V
Z
w
Z
Z
O
CL
ZJ
`
w
CL
Z
M_
®
CL
c1
o
Z
It
O
J
WW
w
J
m
®
�
U
tt1�1
V
O
v
Ww
z
Jw
F_
�
a
0o
T�
Mr
o
J
L.L
rn
co
N�
LIC. AA 260DO897
O M
'ftI M
• Q
0
LL
p/
0
Z
f
J
0
n.
V
I
'w
J
CL
_
WE
N�
z
Q
re
X�
f� ( or. 'fuei�t
I
7'F Consulting Engineers Inc.
MECHANICAL - PLUMBING - ELECTRICAL
9520 S.W. 40 St. Suite # 207 - MIAMI FLORIDA 33165
OFFICE (305) 225-8377 - FAX 305-225-8378
SHEET NO.:
P-1