Loading...
06-1147-006LOW VELOCITY ELBOWS LOW VELOCITY TRANSITIONS LOW VELOCITY OFFSETS STRAP HANGERS TRAPEZE HANGERS w - - -- - - - - = - , STRAP OR 20' _ SUPPORT FROM HANGER ANGLE 1 1/2' X 26 GA GALV ROD R STEEL HANGER STRAP UNDERSIDE OF STRAPS AIR STRUCTURE. AIR_ (5 O.C.) FLOW W 60" MAX UNLESS F OT UNISTRUT CHANNEL R=1 1/2 W SURFACE MOUNTED F4R AIR DUCT (SEE PLAN VIEW) IS PLACED CHANNEL ANCHORED ON EACH FLOOR. DIVERGING FLOW UNDER A THROUGH THE BACK LOW FRICTION LOSS BOTTOML RADIUS ELBOW FULL RADIUS BRANCH TAKE -OFF FITTING 1« REINFORCEMENT OF THE CHANNEL SERE POSSIBLE METAL ROUND FITTING SCREWS SIZE BOLTS) SCREWS MAY BE FOR LOAD 30' MAX. OMITTED IF HANGER LOOPS TABLE 4-1 AIR FLOW DUCT SEIALER NT AND 6' MAX. RECTANGULAR DUCT HANGERS n FLOW TAPE MINIMUM SIZE AIR FLOW INSULATE TOP INSULATED FLEX. DUCT OF DIFFUSER. AND OF SAME SIZE AS HANGER STRAP SEAL JOINT WITH DUCT SEALER AND TAPE DIFFUSER W/ OPPOSED BLADE DAMPER ADAPTOR ROUND TO SQUARE IF REQUIRED FLEXIBLE DUCT CONNECTION DETAIL N.T.S. * FULL CIRCLE INTO DIFFUSER ADAPTER. n CONTRACTION FLOW 30' ELBOWS ® PIPE CLAMP LOW VELOCITY TRANSITIONS, OFFSETS AND ELBOWS. N.T.S. 16 GA. SHEET METAL SADDLE FOR INSULATED PIPES; 1/4" THICK NEOPRENE SLEEVE FOR UNINSULATED PIPES. 1 90' RECTANGULAR STANDARD RECTANGULAR TO ROUND BOOT BOOT W/RECTANGULAR AIR CONNECTION TO ROUND TRANSITION FLOW `- REFRIGERANT PIPE RISER SUPPORT DETAIL BELT- MOUTH CONN. 45' RECTANGULAR L N. T.S. WHERE HEIGHT OF TO ROUND BOOT MAIN DUCT PERMITS CONNECTION w L=1/4W AS PER SMACNA TABLE 4-1 & FIG. 4-4 OR V.D. 4" MIN. V.D. F V.D I V.0 STANDARD 45' G�v'aipfa� RECTANGULAR U` V.D. BOOT CONNECTION F-rating = 2 Hr t-rating = 1 Hr 5 ( 25% FLOW IN BRANCH) 4rataso, CAJ 5111 - \ GALVANIZED ALTERNATE ROUND TO RECTANGULAR DUCT BRANCH CONNECTIONS 1-1 /2" PVC SCH. 40 S ( 25% FLOW IN BRANCH) 4 ,_C1� FIBROUS GLASS DUCT. SLEEVE (TYP.)—FILL WITH INSULATIONF(TYP.) jf REFRIGERANT = GLASS FABRIC AND PIPES LOW VELOCITY BRANCH TAKEOFFS • _ ' AND MASTIC (GFM) TYPICAL SUPPORT 1. ►- . ' •► BETWEEN FLOORS N.T.S. --- / CLOSURE OVER POCKECT LOCK AT 8'-0" 0/C AND DUCT BOARD. VERTICALLY HANGER STRAP 3/$" BOLT (MIN) THREADED SCREEN GALV. STEEL 16 A. HANGER RODS SUPER STRUT �� 1111 111 II III II REINFORCEMENT ANGLE 10 Pre-Roted Concrete Floor of Wall Assembly = Min. 4 1/2" thickness. 8" MIN. PIPE FAN COIL UNIT SUPPORT 12" ® Metallic Pipe - A) Steel Pipe-2" diam. (or smaller) Sch. 10 (or heavier) steel pipe. SURFACE. B) Iron Pipe-2" diam. (or smaller) cast or ductile iron pipe. ROOF CURB 50" C) Copper Tubing-2" diom. (or smaller) Type K (or heavier) MAX copper tubing. ROOFING #10 X 1-1/4 SHEET METAL SCREWS D) Copper Pipe-2" diam. (or smaller) Regular (or heavier) 12" •• copper pipe. MAX. O.C. MIN. 2 PER SIDE. 22 Go. SHEET METAL . ::; :•:::• :::::::::v :• (3) Pipe Covering-Nom. 3/4" thick AB/PVC flexible foam insulation. The annular POCKET LOCK 1» X1» X1» BAND OF SAME SIZE space shall be min. 1/8" to max. 1/4" within the firestop system. REFRIGERANT PIPE AS HANGER STRAP CHASE IN PARTITION 40 TREMstop IA -Min. 1" thickness of sealant applied within opening, flush with the top surface of floor or both surfaces of wall assembly. Additional fill material to be installed such that o min. 1/4" crown is formed around the penetrating item. DUCT HANGER DETAIL(HIGH PRESSURE) TWO HOUR RATED WALL AND CONNECTION DETAIL REFRIGERANT PIPING COWL DETAIL N.T.S. N.Y.S. NOTE: PLENUM CONNECTION PER FBC SECTION (603.1.3) N.T.S. SLAB PIPING PENETRATION. N.T.S. NOTE: NOTE: ROOF MOUNTED UNITS, IS BASED ON CONDENSING UNIT TIE DOWNS TO THE ROOF DECK THE REQUIREMENT'S OF THE FLORIDA OR ATTACHMENT TO SUPPORTING STRUCTURE. BUILDING CODE, TO COMPLY WITH THE THE TIE DOWN POINTS HELP PROTECT AGAINST WIND RESISTANCE AND ANCHORING AS FAN COIL UNIT SECURED 1'-6" HIGH WINDLOADS. MINIMUN OF 2 WIRES. SPECIFIED IN SECTIONS 301.13 AND 301.13.1 TO STRUCTURE W/ 3/8" DIA GALV. THREADED TURNING VANES MIN. RODS PROVIDE VIBRATION ISOLATORS FOR SMACNA - MASON MODEL PC30N OR EQUAL CONCRETE JOIST. SCREWS SHALL BE RATED FOR 50Q LBS. STANDARDS. 1THICK CORK/ MINIMUN PULL-OUT CAPACITY. F " NEOPRENE PAD NEW HURRICANE C.0 EXISTING C.U. EXISTING C.U. EXISTING C.U. " REFRIGERANT DUCT MINIMUM 1$ GA_ X 3-5/$ WIDE CUP. OUTSIDE AIR INTAKE DUCT PIPES TYPICAL s70--DEGREE TIE -GOWN STAINLESS STEEL GRADE 50 STEEL, (G90) OR EQUIVALENT WIRE (TYP.) SEE TIE -DOWN HOT DIPPED GALV. COATING.(TYPICAL 1 EACH CORNER). HANGER RODS —� METHOD DETAIL. FASTEN VERTICAL LEG ATTACH TO UNIT WITH (3) 2210 OR 2ING 8-18 X 1/2"0 S.STETRUCTL TWIN -FAST SELF �--- VANED ELBOW DETAIL. PITCH PAN DRILLING SCREWS. FASTEN TO STRUCTURE WITH (2) 3/8"0 � N.T.S. (ALL LEGS) \ z STAINLESS STEEL BOLTS. FIN ROOF X C.U. UNIT. LU / VD Q DISCHARGE DUCT 3" IN ALL FOUR SIDES RETURN AIR PLENUM DISCONNECTED SWITCH ROOF STRUCTURE RETURN AIR GRILLE " " \ F P OTHER O O Q u 6"X6 X1/4 STEEL PLATE BOLTED DETAIL ON THIS SHEET. ER O PROVIDE 3/4" DRAIN CONNECTION 3/4" CONDENSATE DRAIN LINE TO CONCRETE DECK WITH 3/8"0 W/ REMOVABLE PLUG. 24 GA. MIN. AND TRAP. GALV. STEEL DRAIN PAN 1-1 2" AUXILIARY DRAIN PAN W FLOAT SWITCH GALV. STEEL BOLTS THRU CONC. DECK. / ° PROVIDE NUTS dt PRESSURE WASHERS. CONTROL APPROVER NUMBER DEEP MIN. ALL WELDED CONSTRUCTION. FLOAT SWITCH TO STOP UNIT WHEN SWITCH OPEN. "ALUMA STAND" EXPOSURE "C" ISOLATOR PAD 4 PER UNIT. ANCHOR BOLTS APPROVE NO. NOA 02-0514.02 MOUNTING STRUCTURE (SEE DETAIL) CONDENSING UNIT MOUNTING DETAIL C.U. UNIT TIE DOWN DETAIL HORIZONTAL FAN COIL UNIT MOUNTING DETAIL REFER TO ROOF PLAN FOR EXACT QUANTITY OF CONDENSING UNITS. N.T.S. N.T.S. N.T.S. MAXIMUM PAIR AT PAIR AT PAIR AT PAIR AT HALF OF 10 FT SPACING 8 FT SPACING 5 FT SPACING 4 FT SPACING DUCT WIRE/ WIRE/ WIRE/ WIRE/ PERIMETER STRAP ROD STRAP ROD STRAP ROD STRAP ROD 2 = 30" 1"x22 GA. 10 GA. (.135") " t x22 GA. 10 GA. (.135") " 1 x22 GA. ( 06') 1"x22 GA. 12 GA. (.106") P = 72" 1"x18 GA. 3/8" 1"x20 GA. 1/4' 1"x22 GA. 1/4" 1"x22 GA. 1/4" 2 P 96" 1 "x16 GA. 3/8" 1 "xt 8 GA. 3/8" 1 "x20 GA. 3/8" 1 "x22 GA. 1/4" 2 P = 120" 1.5"x16 GA. 1/2" 1"x16 GA. 3/8" 1"x18 GA. 3/8' 1"x20 GA. 1/4" 2 P = 168" 1.5"06 GA. 1/2" 1.5"06 GA. 1/2" 1 "x16 GA. 1/2" 1 "x18 GA. 3/8" 2 a= 192" - 1/2" 1.5"x 16 GA. 1/2" 1 "x16 GA. 1/2" 1 "x16 GA. 3/8" 2 = 193" UP SPECIAL ANALYSIS REQUIRED u: r w w 0 0 w W � � m U) 0) m I w Co w o w O� a U o Ir Cj� CP oL0 L0 C� W LL �+ <- W Z00 °' `0 ZLO 0 rn v z w z o z w J CL M L.1. z a: O ILL W �y LL w m a� 1— V O U Ww _J LLI J= o o�/ J L1. N LIC. AA 26=897 ® Q M cf' `M M • Q IU6 2 OO ,h V 2 • a • G �= OOD w J H y z z rY 0