02-930-1585 TON 5 TON ....................................................... .... ................................ .................... ...................... ........... 4 TON 5 TON 525 TON VIBRATION ISOLATOR SCHEDULE TYPE DESCRIPTION USE MANUFACTURER ISOLATING PAD, BONDED PERMANENTLY i TO 3/4" STEEL PLATE FOR EQUIPMENT ROOF C.U.'S KORFUND TYPE EU MOUNTING SPRING ISOLATOR, FREE STANDING, LATERALLY STABLE, UNHOU�SED,rWITH KORFUND SERIES II LEVELING BOLTS AND 1/4" THICK NOT USED WSC MIN. 1/2" (' ISOLATING PAD DEFLECTION) SPRING ISOLATED INERTIA BASE: REINFORCED CONCRETE POURED INTO III WELDED STEEL FRAME AND ISOLATED NOT USED BY TYPE 11 ISOLATOR SPRING ISOLATED HANGERS: IV COMBINATION OF SPRING AND RUBBER AHU-11(LOBBY) KORFUND TYPE VX (MIN.1" DEFLECTION) IN SHEAR IN SERIES, ALL ENCASED iN WELDED STEEL BRACKETS N OTES : 1. ALL SPRING ISOLATORS SHALL HAVE AN ADDITIONAL TRAVEL OF 50 % BETWEEN DESIGN HEIGHT AND SOLID HEIGHT, SHALL HAVE THE SAME DEFLECTION FOR EACH EQUIPMENT, AND THEIR OUTSIDE DIAMETER SHALL NOT BE LESS THAN 80 % OF THEIR OPERATING HEIGHT. 2. DEFLECTION SHALL BE AS SHOWN ON CONTRACT DOCUMENTS. AIR CONDITIONING LEGEND A. FD FIRE DAMPER MOUNTED VERTICALLY FIRE DAMPER MOUNTED HORIZONTALLY FD -I FIRE AND SMOKE DAMPER MOUNTED VERTICALLY -....�:..�`:. FS D FSD FIRE AND SMOKE DAMPER MOUNTED HORIZONTALLY CEILING RADIATION DAMPER SMOKE DAMPER WALL FIRE RATING LEGEND NOT RATED ONE HOUR FIRE RATED TWO HOUR FIRE RATED OWNER/DEVELOPER: Fmv THE PLAZ) il RiCFARDE B A11DOn EiCOMPANY 73W S.W. 57 COU SUITE 400 4960 S.W. 72 AVENUE MIAMI, FLORIDA 33155 CITY OF SOUTH N 305.E62.1421 SOUTH MIAMI, FL( A/C SPLIT SYSTEM SCHEDULE DESIGNATION Ali d (SOIITN ft LMIES) ANf1-2 NORTH ft LO;.etES) AHU-3 AHU-4 AHU-5 AHU-6 AREA SERVED COORRA0LOB3ES COORZho1.03;31ES OFFICES OF:NcC S Of-ricEs OFFICES MANUFACTURER TRANS TRANE TRANS TRANS TRANS TRANE FAN COIL MODEL No. TWE060 TWE060 TWE048 TWE060 TWE063 TWE062 CONDENSING UNIT MODEL No. 2TTR2060 2TTR2060 2TTFU048 2TTFU060 2TTR2060 (2) 2TTF22036 COMBINED RATINGS TOTAL SENSIBLE CAPACITY BTU/HR 6m,500 60r500 49,500 60,500 61000 (03,000 GRAND TOTAL CAPACITY BTU HR 43,800 43000 35,900 43AOO 45100 48,400 TOTAL HEATING CAPACITY BTU H R 25,500 25,500 25,500 25,500 25,500 25,500 ENERGY EFFICIENCY RATIO SEER (EER) 12.50 12.50 1228 12.50 12.0 10.4 COEFFICIENT OF PERFORMANCE COP - - - - - - FAN COIL UNIT TYPE VERTICAL. VERTICAL. VERTICAL. VERTICAL VERTICAL VERTICAL TOTAL AIR SUPPLY CFM 1,500 1,800 1,600 1)300 2,000 2,100 OUTSIDE AIR SUPPLY CFM 300 300 360 200 230 460 ENTERING AIR CONDITIONS FDB FWB 80/61 80/61 80/61 80/61 80/61 80/61 EVAPORATOR COIL MIN. ROWS MAX. F.P.I. - - - - - - EXTERNAL STATIC PRESSURE "H 20 05 0.5 05 OB 05 05 FAN SPEED RPM HiGH SPEED HiGH SPEED HIGH SPEED HIGH SPEED HIGH SPEED HiGH SPEED FAN MOTOR HP 1% 11/1 11/2 'i2 3/4 3/4 ELECTRICAL SERVICE AVAILABLE 1 208/1/60 208/i/60 208/1/60 208/1/60 206/1/60 208/1/60 RUNNING LOAD AMPS 3.1 3.1 4.2 3. 1 3.9 1. 0 (EACH) ELECTRIC RESISTANCE HEATER SIZE KW 1.5 IB 1.5 1 1.5 1.5 1 1.5 UNIT WEIGHT - 225 225 C O N D E N S I N G U N I T TYPE AiR COOLED AIR COOLED AiR COOLED AiR COOLED AiR COOLED AIR COOLED LOCATION ROOF ROOF ROOF ROOF ROOF ROOF, REFRIGERANT TYPE R-22 R-22 R-22 R-22 R-22 R-22 AMBIENT AIR TEMPERATURE FDB g5 fi Q5'F S50F g5'F g5"F 9519 NUMBER OF COMPRESSORS 1 1 1 1 1 2 NUMBER OF REFRIGERANT CIRCUITS 1 1 1 i 1 2 CAPACITY REDUCTION STEPS % 0-100 0-100 0-100 0-100 0-100 0-50-100 ELECTRICAL SERVICE AVAILABLE 20B/l/60 208/i/60 208/i160 208/1/60 208/1/60 208/i/60 RUNNING LOAD AMPS 24.0 24.0 24.0 24.0 24.0 25.0 MINIMUM CIRCUIT AMPS 38.0 38.0 35.0 38.0 35.0 40.0 MAXIMUM FUSE SiZE AMPS 60.0 60.0 60.0 60.0 60.0 60.0 UNIT WEIGHT 212 212 212 212 212 212 A C C E S S O R I E S REFRIGERANT PIPING LENGHT FT. -': b0 -': 60 -': 60 -:: 60 -' 60 -': 60 LIQUID LINE TYPE O.D. - - - - - - SUCTION LINE SIZE O.D. THERMOSTAT HEAT/COOL HEAT/COOL HEAT/COOL HEAT/COOL HEAT/COOL HEAT/COOL FILTER SECTION AND FILTER TYPE i'iz' THROWAWAY i'i,' THROWAWAY iliz' THROWAWAY 11/2' THROWAWAY 1112' THROWAWAY 11i2' THROWAWAY SMOKE DETECTOR IN SUPPLY IN SUPPLY IN SUPPLY IN SUPPLY IN SUPPLY iN SUPPLY V I B RATION ISOLATORS FOR FAN COIL UNIT FOR CONDENSING UNIT AUTO MATIC CONTROLS TYPE- DESCRiPTION 01 PROVIDE SINGLE POINT ELECTRICAL CONNECTION WITH BUILT IN CIRCUIT BREAKER 57 RT IIAMI )RiDA 33143 OUTSIDE AIR CALCULATIONS ._.._. AC-L.Or3�iE5 L055Y AND i✓EOPLE - - ... - _... - ----- - - - - w 20 G=M/P= R5CN ------ 300 ----, CFM / O/A CORRIDOR (5TH FL.): - CIA PROVIDED 300 CFM / CIA; AC-L055IE,5 L---- LO55Y AND 5,045 cer-------i. P,ECPE--- V 20 Cr^i/P`R5'.3'N- - _300 CFm / O/A, .... CORRIDOR (5TH FL.) - - --- CIA PROVIDED 300 CFM / O/A -------.---_- _- _--.----- ._ OFICES (E7TN FLOOR) ------ - --- .. _ ......... __ _.. _ - OFFICES 28,441 *'x 1 PER$ / 1000 0 - ..... _- _. _ __-_ --- ----._ 200 PER$ x 20 CFM / PERS = 4000 CFM / CIA CIA PROVIDED 2721 CPM / O/A' OFFIcEs (4TH FLOOR) ....................... - - .__ - OFFICES lgC;&3 V x -I PERS / 1000 t .............. ....... _ _ ....... - ........ -- ';14 PERS x 20 GFIM / PERS - -- 227 i _ CFM / O/A' ..... _ .. 0/A PROVIDED 2 400 - CFM / O/A AIR DISTRIBUTION SCHEDULE DESIGNATION 19 L O USE SUPPLY RETURN SUPPLY OUTSIDE AIR EXH. LOUVER CONSTRUCTION ALL ALUMINUM ALL ALUMINUM ALL ALUMINUM ALL ALUMINUM ALL ALUMINUM CAPACITY (C.F.M.) SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS SIZE SEE PLANS SEE PLANS SEE PLANS SEE PLANS S3rE PLANS TYPE 24' x 24' MODEL R PERI--ORATED LINEAR COMMENTS 4- 3/4' SLOTS 4' LONG W/ LINED PLENUM WiTH MIAMI-DADS COUNTY PRODUCT APPROVAL FINISH BRUSHED ALUM. BRUSHED ALUM. BRUSHED ALUM. ANODIZED ALUMiNUM(PER ARCH.) MOUNTING TYPE T - BAR T - BAR PLASTER MASONRY FLANGEMASONRY FLAN NOISE CRITERIA 30 MAX 30 MAX 30 MAX - - MANUFACTURER METALAiRIE 1 METALAIRE METALAIRE METALAIRE PENN MODEL 1000-6 RHF 6015 A C C E S S O R I E S OPPOSED BLADE DAMPER 05D - - - - FIRE DAMPER - - - - BIRD SCREEN N/A N/A N/A YES YES CONNECTION SIZE I SEE PLANS SEE PLANS SEE PLANS SEE PLANS BEE PLANS NOTES 1. FINISHES AND TYPES OF MOUNTS SHALL BE COORDINATED WiTH ARCHITECTURAL DRAWiNrsS. 2- PROVIDE CB. DAMPER AT ALL SUPPLY OUTLETS. 3. AIR PATTERN AND DIFFUSER FACE SHOWN ON PLANS. 4. DIFFUSER NECK SIZE SHOWN ON PLANS. VENTILATION EQUIPMENT SCHEDULE DESIGNATION EF-i EF-2 Et"- EF-4 OA-1 GR-1 QUANTITY SEE PLAN SEE PLAN SEE PLAN SEE PLAN SFE PLAN 2 USE EXHAUST EXHAUST EXHAUST EXHAUST 01A SUPPLY ELEV. RELIEF: LOCATION 2ND, 3RD ROOF ROOF WALL MOUNTED ROOF ROC -- AREA SERVED PARING 4TN t 5T1.1(TOiLET5) GRD. FL. TOILETS ELECTJTI= Rt G OUND F MANUFACTURER PENN PENN PEW PENN PENN PENN MODEL N 0 . BCF136 DX16 DXlb P10VA AF-24 AIRETTE F A N 3b `x3b' TYPE BELT PROPELLER BELT MTRIFZA-I BELT CEITRiF4AL BELT PROPELLER FILTERED SIPPLY RELIEF AIR FLOW C. F. M . 15100 GFM 1,550 GPM 1000 GFM 450 CFM 2,000 N/A EXTERNAL STATIC PRESSURE " H z 0 0.125 OBO 050 025 050 N/A FAN SPEED R.P.M. b90 6,50 150 N/A FAN SOUND RATINGS, SONES 13.2 85 1.8 12 N/A N/A M 0 T 0 R TYPE - - - - ODP N/A HORSEPOWER H.P. I/s 1/4 1/4 1/30 3/4 N/A FULL LOAD AMPS. 913 5.8 5.8 13.8 N/A ELECTRICAL SERVICE AVAILABLE 120/1/60 ( 120-1-60 120-1-60 120-1-60 120/I/60 N/A STARTER TYPE A.L. AL. AL. A1. A1. N/A STARTER FURNISHED BY MECH. CONT. MECH. CONT. MECH. CONT. MECH. GCNT. MECH. CONT. N/A G E N E R A L D A T A LOCATION 51DEWALL ROOF ROOF 5IDEWALL ROOF ROOF MASONRY OPENING REQUIRED - 2051 2051 15 3/4' 51 261# 36'x36' OPERATING WEIGHT - 150 150 112 (ONLY FAN) 2w 280 A C C E S S O R I E S FACTORY C U R B N/A YES YES NIA YES YES SERVICE SWITCH YES YES VIES YES YE9 N/A BAC K D RAFT DAMPER - YES YES - MO T ORIZED N/A BiRD SCREEN YFS YES YES YES YES YE5 DISCHARGE LOUVER - - - - N/A K/A OTHER 1 N/A N/A I N/A h/A V I B R A T I O N I S O L A T 0 R S TYP E N/A N/A N/A N/A N/A N/A MINIMUM STATIC DEFLECTION INCH. N/A N/A N/A WA N/A N/A A U T O M A T I C C 0 N T R 0 L S TYPE - - - - I N/A DESCRIPTION - - - - SEE NOTES NIA ACCEMMIES 0 PROVIDE W/ BACK GUARD, WALL SLEEVE, PANEL FAN 4 FRONT GUARD CONTROL 2ES9331ETi4N I INTERLOCK WiTH GROUND FLOOR AHU'S TO OPERATE DURING OCCUPIED SCHEDULE. PROVIDE MOTORIZED DAMPERS AT EACH C/A SUPPLY TO GROUND FLOOR UNITS TO CL05E WHEN UNIT 15 OF DUTY. PROVIDE AUTOMATIC DUCT PRESSURE RELIEF A5 SHOUR HVAC NOTES 1.0 GENE 1 1.1 PROVIDE ( FURNISH AND INSTALL } ALL NECESSARY MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SYSTEM AS DEPICTED ON THESE CONTRACT DOCUMENTS. 1.2 INSTALL IN ACCORDANCE WITH THE SOUTH FLORIDA CODE, ASHRAE SMACNA, NFPA AND LOCAL ORDINANCES. 1.3 SCOPE OF WORK PROVIDE THE FOLLOWING COMPLETE SYSTEMS A. AIR CONDITIONING SUPPLY AND RETURN DUCT SYSTEM. B. EXHAUST SYSTEM FOR TOILET ROOMS. C. EXHAUST SYSTEMS FOR WAREHOUSE. D. AIR CONDITIONING UNITS AND CONTROLS. E. INDEPENDENT TEST AND BALANCE. 1 A NOT USED 1.5 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED 1.6 VERIFY AT JOB SITE ALL SPACE CONDITIONS AVAILABLE FOR THE INSTALLATION OF MATERIALS AND EQUIPMENT PRIOR THE INSTALLATION OF EQUIPMENT A QAND FABRICATION OF DUCTS AND PIPING SYSTEMS. COORDINATE SPACE REQUIREMENTS FOR SERVICE AND MAINTENANCE AND COORDINATE INTERFERENCE WITH OTHER TRADES. 1.7 NATURE OF DESIGN DRAWINGS; DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT INTEND TO SHOW EVERY FITTING, ELBOW, TRANSITION, ETC. THAT WILL BE NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEMS REQUIRED BY THESE SPECIFICATIONS. 1.8 COORDINATION DRAWINGS; PREPARE 1/4" SCALE (MIN.) COORDINATION DRAWINGS SHOWING DUCTWORK, PIPING AND ALL MAJOR SYSTEM COMPONENTS FOR A/E APPROVAL BEFORE PROCEEDING WITH THE INSTALLATION. IMPLEMENT ALL INFORMATION FROM 1.6 ABOVE, 1.9 SUBMIT SHOP DRAWINGS FOR A/E APPROVAL BEFORE PROCEEDING WiTH THE THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. ALL SHOP DRAWINGS MUST BE SUBMITTED IN A SINGLE BOUND AND INDEXED PACKAGE NO LATER THAN 30 DAYS FROM THE ADJUDICATION OF THE PROJECT. 1.10 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A A PERIOD OF ONE YEAR FROM THE DATE OF PROJECT ACCEPTANCE. 2.0 M&TMALS 2.1 DUCTWORK 2.1.1 GENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. 2.1.2 DUCTWORK MATERIALS: A: GENERAL OFFICE AREAS: FIVE POUNDS DENSITY 1.5" THICK GLASS FIBER (R-6) DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA'S FIBROUS GLASS DUCT CONSTRUCTION STANDARDS. DUCT JOINTS SHALL BE SEALED AND TAPED. B: TOILET ROOM EXHAUST AND FRESH AIR INTAKES: GALVANIZED SHEET METAL, CONSTRUCTED, AND INSTALLED ACCORDING TO LATEST EDITION OF SMACNA'S. LOW PRESSURE CONSTRUCTION STD. (0.5" W.G.) C: EXPOSED AIR CONDITIONING DUCTWORK SPIRAL GALVANIZED SHEET METAL, CONSTRUCTED, AND INSTALLED ACCORDING TO LATEST EDITION OF SMACNA'S. LOW PRESSURE CONSTRUCTION STD. (0.5" W.G.) 2.1.3 PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL SQUARE ELBOWS. WHERE THE ELBOWS ARE RECTANGULAR INSTALL SINGLE THICKNESS VANES. .1 ALTERNATE A: PROVIDE 3---PIECE ELBOWS iN LIEU OF TURNING VANES FOR GLASS FIBER DUCTS ONLY. .2 ALTERNATE A: PROVIDE FULL RADIOS ELBOWS IN LIEU OF TURNING VANES. 2.1.4 PROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLY OUTLET AND AT EACH DUCT BRANCH. 2.2 NOT USED. 2.3 NOT USED. 2.4 AIR DISTRIBUTION PRODUCTS : 2.4.1 PROVIDE EXTRUDED ALL ALUMINUM AIR DISTRIBUTION PRODUCTS. 2.4.2 PROVIDE SUPPLY AND RETURN GRILLES AND DIFFUSERS AS INDICATED ON THE DRAWINGS AND SCHEDULES. 2.4.3 PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL DRAWINGS. 2.4.4 PROVIDE OPPOSED BLADE, KEY OPERATED DAMPERS BEHIND ALL AIR SUPPLY OUTLETS. 2.5 PROVIDE A MINIMUM 5 YEAR WARRANTY FOR ALL AIR CONDITIONING COMPRESSORS STARTING FROM THE DATE OF PROJECT ACCEPTANCE. 2.6 CONTROLS: 2.6.1 GENERAL: PROVIDE THE NECESSARY AUTOMATIC CONTROLS FOR PROPER OPERATION OF ALL EQUIPMENT SPECIFIED HEREIN, FURNISH MAGNETIC STARTERS AND INTERLOCK WIRING INDICATED FOR EACH PiECE- OF EQUIPMENT. 2.6.2 OFFICE AREA DX EQUIPMENT: PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW VOLTAGE HEAT/COOL THERMOSTATS WITH ON -OFF AUTO SUB --BASE SWITCH AS FURNISHED BY THE EQUIPMENT MANUFACTURER. 2.7 STARTERS: PROVIDE MAGNETIC STARTER FOR ALL MECHANICAL EQUIPMENT IN THIS SECTION AS DESCRIBED ON THE EQUIPMENT SCHEDULES, ALL STARTERS MUST HAVE HAND -OFF -AUTO POSITION SWITCH ON THE COVER AND RED/GREEN PILOT LIGHTS. PROVIDE THE NECESSARY AUXILIARY OPEN AND CLOSED CONTACTS FOR THE INTENDED OPERATION AND INTERLOCKS. 2.8 NOT USED. 2.9 IDENTIFICATION: 2.9.1 LABEL ALL EQUIPMENT WITH ENGRAVED BLACK PLASTIC PLAQUES 12"x4" HIGH WITH WITH 1.5" LETTERS. USE THE SAME NOMENCLATURE AS IN THESE DOCUMENTS. 2.10 RETURN AIR CEILING PLENUMS: 2.10.1 WHEN CEILING SPACES ARE USED AS "RETURN AIR CEILING PLENUMS" ALL MATERIALS INSIDE THE R/A CEILING PLENUM SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF 50 PER NFPA 90A. "NO PVC PIPING iS ALLOWED INSIDE THE R/A PLENUM." 2.10.2 PROVIDE FREE PATH FOR R/A INSIDE CEILING SPACE. SEE ARCHITECTURAL PLAN FOR COORDINATION 3.0 EXECUTION 3.1 INSTALL ALL EQUIPMENT AND MATERIALS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S MANUALS AND RECOMMENDATIONS, PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES FOR INSTALLATION, OPERATION SERVICE. FOR INSTALLATION, OPERATION AND SERVICE. 3.2 PAiNT ALL PIPING WITH 2-COATS OF LATEX PAINT WITH COLORS AS FOLLOWS: CWS - DARK GREEN CHWS --- DARK BLUE CA - YELLOW CWR - LIGHT GREEN CHWR - LiGHT BLUE 3.3 THERMOSTAT LOCATION. THERMOSTAT LOCATION IS CRITICAL TO PROPER EQUIPMENT OPERATION. INSTALL THERMOSTAT AT LOCATIONS SHOWN ON PLANS. RELOCATE ONLY WHEN APPROVED BY THE A/E IN WRITING. 3.4 WHERE R/A IS PROPOSED BY WAY OF DOOR UNDERCUTS, PROVIDE A MINIMUM 1" CLEAR SPACE BETWEEN THE BOTTOM OF THE DOOR AND THE FLOOR FiNISH CARPET OR TILE. TYPICALLY USED FOR ROOMS WITH 50 CFM'S OR LESS. 3.4 WHERE R/A FOR ROOMS IS PROPOSED WITH DOOR LOUVER, CONTRACTOR MUST COORDINATE WITH DOOR MANUFACTURER AND INSTALLER IN ORDER TO PROVIDE CORRECT SIZE LOUVER AND DOOR. 3.6 EQUIPMENT MUST OPERATE FREE OF OBJECTIONABLE NOISE AND VIBRATION REPAIR AND/OR REPLACE ALL SOURCES OF NOISE AND VIBRATION FOUND TO BE OBJECTIONABLE, TO THE SATISFACTION OF THE A/E. 3.7 BALANCE ALL SYSTEMS TO PROVIDE AIR AND WATER QUANTITIES AND CAPACITIES TO MATCH SPECIFIED FLOWS & CAPACITIES. CALIBRATE FLOWS TO NEW EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. SUBMIT FINAL TEST AND BALANCE REPORT TO A/E FOR ACCEPTANCE. r ANTONIO FRANYIE PE #11W MECH CHANDLER AND ASSOCIATES No' DATE R sTON No. DATE U'DATBD PHUT SET )OSE I MOT!ACAS AR P.A. - 71Q-03 CONDO U M PE #15115 ELECT. AA 0003050 MIANA FRANYIE ClUkA PE #4"85 MECH 5940 S.W. 73RI) STREET 10610 NW 27 Street MIAMI FL 33T/2 SOUTH MIAMI, FL.OPMA 33143 0651592-1360 • FAX W5W9F9 "fiarMeenzrineerscorn DESIGN DRAWN DATE TEL 04 669-7592 AF. RR `i-10-03 FAX (34 669-7593 JOTt NUM6ER 9°i-145 (2003) G>WYF =xr 3w PERMIT SET DRAWING `TITLE: R�/TSION SCHEDULES AND NOTES ELAN SCALE: DATE: JLM 1% 2003 PROJECT NO: 9902.2 DRAWING NO: AC-8