02-930-150mff.lffw�
3/4"
N.T.S.
TOP OF PAVING
�T
CONCRETE VALVE BOX
CAST IRON FERRULE W/CAST
BRONZE COUNTERSUNK PLUG
CHICAGO SILL COCK
MODEL NO. 387
3/4" HOSE BiBB WITH
EMOVABLE TEE HANDLE
)N-REMOVABLE
`,CK-FLOW PREVENTOR
ATTS" MODEL No. 8-A
HEAVY DUTY 9" X 9"
ACCESS COVER
AND FRAME
CLEAN OUT EXTENSION PIPE SAME
SIZE AS BUILDING SEWER OR DRAIN
AND 6" MAXIMUM
BUILDING DRAW OR SEWER
EXTERIOR CLEAN OUT DETAIL
N.T.S.
11/2' A/C CONDENSATE DRAIN
SLOPE * 1/4' PIER F-OOT MINIMUM
PiPE C-LA P ATTACHED TO
4'x4' PT 48' O/G MAX.
ROOF MEM51;_l4NEi 1�m'w
r _ -�. uEE
12 x!2 I-�4E'AV D:1l l AS! -HALT 9, ET 4`x4'x26 GA. 5HEET METAL
"5CREIUD TO 4'x4' PT AND 5AGKiNG PLATE UNDER
HOT MOPPED TO ROOF- MEM:3r"2ANE ASPHALT 5I-IEi T,
A/C CONDENSATED SUPPORT DETAIL,
N.T.S.
OWNER/DEVELOPER:
FgMq THE
DRAIN SCHEDULE
UNIT DESIGNATION
ROOF DRAIN
AD
FD
FD
DD
MANUFACTURER
ZURN *
ZURN
ZURN
ZURN
ZURN
MODEL TYPE
Z-121-E
Z-533
Z5-415-65-P
Z-541
Z-158
ACCESORIES
-
-
POLISHED BRONZE
CAST IRON
POLISHED BRONZE
TYPE
LOW SILHOUETTE
DECK DRAiN
FLOOR DRAIN
H.D. FLOOR DRAiN
DECK DRAIN
DESCRIPTION
COATED CAST -
COATED CAST -
6x6 5Q. ADJ.
12' # TOP WITH
8' 0 TOP WITH
IRON, WITH CAST
IRON BOTTOM
STRAINER TOP
REMOV4I5LE
REMOVABLE
IRON DOME
OUTLET
HEELFROOF
SEDIMENT C.I. BUCKET
SHALLOW SEDIMENT
TRAP PRIMER
HEAVY DUTY CRATE
CAST-iiRON 5UCKET
LOCATION
ROOF
PARKING
TOILET ROOMS
MECHANICAL AREAS
PORCH AREA
J.R. SMITH No. 4253 ADJUSTABLE
C.I. FLOOR LEVEL CLEAN OUT
PLUMBING FIXTURE SCHEDULE
w/NICKEL BRONZE TOP WATERTIGHT
SYMBOL
FIXTURE TYPE
S Z,E
G.W.
N.W.
DESCRIPTION
MODEL
FAUCET -TRIM
EWC
ELEC. WATER COOLER
114'
i 2
_
WALL HUNG ELECTRIC WATER COOLER
STAINLESS STEEL FiNiSH
MFG. HAWS
HOTEL HC5Fid
WALL HANGER P-TRAP
AND SUPPLY
WC
WATER CLOSET
WALL HUNG
41
it
-
ELONGATED WATER SAVER, VITREOUS
CHINA, 51PHON JET FLUSHING ACTION
AFWALL 2258.125
WALL HUNG
OLSONiTE OPEN FRONT SEAT LESS COVER
*55, SLOAN ROYAL FLUSH VALVE 4 CARRIER
WC-H
WATER CLOSET
WALL HUNG
4'
I,
_
ELONGATED WATER SAVER, VITREOUS CHINA
SIPHON JET ACTION, HIGH FOR WHEELCHAIR
AFWALL ADA 2258.125
WALL HUNG
OL50NITE OPEN FRONT SEAT LESS COVER
No. S5, SLOAN ROYAL FLUSH VALVE 4 CARRIER
-CONCRETE SLAB
UR
URINAL
2'
34,
-
ViTREOU5 CHINA WA5H-OUT
WASPBROOK 6501.010
SLOAN ROYAL FLUSH VALVE
No, 186, WALL CARRIER
LAV-i
LAVATORY
11/4"
iiz'
VITREOUS CHINA WITH FRONT
OVERFLOW � , .- LOW FAUCET LEDGE
LUCERNE 0356.015
HERITAGE LAY. FAUCET 6801000 W/GROWN
HANDLES P-TRAP E SUPPLY WALL CARRIER
LAV-2
LAVATORY
i /4
I, ,
_
VITREOUS CHINA WITH FRONT
SELF-R?MINS, FRONT OvF-F; =LOW
AQUALYN 04752Z5
HERITAGE LAV. FAUCET &SO1000 W/CROWNI
HANDLES P-TRAP4 SUPPLIES
VITREOUS CHINA WHE-LCHAiR
ATI'TlT LAVATORY
HERITAG= LAY FAUCET 2238129 DRAiN
LAV-H
LAVATORY (
I14`
ins"
-
LAVATORY
9140.013
ASSEMBLY #11123.018 P-TRAP 4 SUPPLIES
INTERIOR CLEAN OUT DETAIL
J5
JANITOR SINK
ltiz'
�Z
_
ENAMELED CAST IRON DRILLED
BACK RIM GUARD
AKRON SiNK
i6e5018
HERITAGE FAUCET 8340234
A\IP-TRAP
NO SCALE
:R ROD FASTEN TO
:TURF PER SPECIFICATION
CLEViS TYPE HANGER
SEE NOTE BELOW.
PLUMBING PIPE.
NOTE:
PROVIDE COPPER HANGERS FOR
COPPER PIPE. (NOT COPPER CLAD)
OVERHEAD PIPE SUPPORT
NO SCALE
*ACO DRAINAGE CHANNEL PER PLAN
(SLOPE BOTTOM PER PLAN)
PROVIDE HEAVY DUTY 4.77 ADA DUCTIL
IRON SLOTTED GRATING. SEAL ALL
SPLICES AND END CAPS
PER MANUFACTURER.
7N_N�
CONCRETE FLOOR SLA
�oN,PANY 7300 S.W. 57 COURT
SUITE 400
4,950 S.W. 72 AVENUE
MIAMi, FLORIDA 33155 CITY OF SOUTH MIAMI
305.562.1421 SOUTH MIAMI, FLORIDA 33143
STEEL REINFORCING
PER MANUFACTURERS
MANUAL.
UT SUB
------------------ 2.j Lw I 1 1. c
ip
6" MIN.
POURED IN -PLACE TRENCH.
SEE ARCHITECTURAL DETAILS.
TRENCH DRAIN DETAIL
NTS
NOTE: i- ALL FIXTURES AND TRIM ARE MANUFACTURED BY AMERICAN STANDARD UNLESS NOTED OTHERWISE
2-ALL FIXTURES MAY 3E 5U5MiTTED AS SCHEDULED OR A6 AFFROVED EQUAL.
VENT.
3/4 `C.W.
WET GOLU�I
tT1'PJ
0
TYPICAL OFFICE JET COLUMN PLAN
N.T.S.
TYf = i CAL PIPE P ~'OTE CT i Off! iN PAR<I G
N.T.S.
PLUMBING NOTES
1.0 GENE
1.1 PROVIDE ( FURNISH AND INSTALL) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
SOUTH FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
1.2 SCOPE OF WORK :
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY COLLECTION.
B. GREASE WASTE COLLECTION AND GREASE TRAP.
C. DOMESTIC COLD WATER
D. RAIN WATER COLLECTION
E. AIR CONDITIONING CONDENSATE.
F. C.W. PIPE FOR ELECTRICAL GROUND
1.3 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED.
1.4 VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PiPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATION OR INSTALLATION. COORDINATE REQUIREMENTS
TO AVOID INTERFERENCE WiTH OTHER TRADES.
1.5 NATURE OF DESIGN DRAWINGS:
DESIGN DRAWINGS ARE DIAGRAMATIC AND DO NOT INTEND
TO SHOW EVERY FITTING, ELBOW, TRANSITION, ETC. THAT
WILL BE NECESSARY FOR A COMPLETE OPERATIONAL SYSTEM
AS REQUIRED BY THESE SPECIFICATIONS.
1.6 COORDINATION DRAWINGS:
PREPARE 1 /4" SCALE COORDINATION DRAWINGS SHOWING
MAJOR SYSTEM COMPONENTS FOR A/E APPROVAL.
1.7 SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
1.8 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
2.0 MAMMALS
2.1 PROVIDE SHUT-OFF VALVES FOR EACH FIXTURE AND AiR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMANCE OF THE SYSTEM.
2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OR OTHER PIPING OF DISSIMILAR METALS.
USE CLAMPS AND FASTENERS OF SIMILAR METALS OR
ISOLATE FROM PIPING. ISOLATE PIPING FROM CONCRETE
SLABS AND WALLS TO PREVENT CORROSION.
2.3 PIPING
2.3.1 DOMESTIC COLD AND HOT WATER:
UNDER GROUND BELOW BUILDING:
SOFT COPPER TYPE "K" OR "L" WITHOUT JOINTS.
ABOVE GRADE:
HARD DRAWN COPPER TYPE "M" WITH SOLDERED JOINTS.
VALVES:
125 PSiG MIN. WOG BRONZE VALVES
HOT WATER INSULATION:
1" PRE -FORMED GLASS FIBER W/FIRE RATED A.S.JACKET.
2.3.2 SANITARY WASTE AND VENT:
UNDER GROUND BELOW BUILDING:
CENTRIFUGALLY SPUN CAST IRON PPE NO -HUB FITTINGS
SCH. 40 P.V.C. D.W.V. PIPE do FITTINGS MAY BE USED
WHERE ALLOWED BY THE LOCAL JURISDICTION.
ABOVE GRADE:
CENTRIFUGALLY SPUN CAST IRON PIPE NO -HUB FITTINGS
SCH. 40 P.V.C. DWV PIPE AND FITTINGS MAY BE USED
WHERE ALLOWED BY THE LOCAL JURISDICTION.
2.3.3 RAIN WATER COLLECTION:
SAME AS SANITARY WASTE AND VENT PER 2.3.2 ABOVE.
2.3.4 A/C CONDENSATE: PVC SCEDULE 40 PIPE AND FITTINGS.
2.4 NO PVC PIPING MAY BE USED INSIDE RETURN AIR
AiR CONDITIONING PLENUMS.
3.0 EXECUTION
3.1 SEPARATE ALL PIPING FROM CONCRETE BY USING
SLEEVES THRU WALLS AND FLOORS. CAULK ANNULAR
SPACE WITH APPROVED FIRE RATED CAULKING.
3.2 PROVIDE FiRE SAFING AT ALL PIPING PENETRATIONS AS
PER DETAILS PROVIDED.
3.3 DO NOT INSTALL PVC PIPING IN CEILING SPACES INTENDED
FOR RETURN AIR PLENUMS.
3.4 DO NOT INSTALL ANY PIPING ( WATER, SANITARY, VENT,
STORM, ETC.) INSIDE ELEVATOR EQUIPMENT ROOMS.
TOILET
FACILITY
OCCUPANT
LOAD
CAS PER TA5L1=
- -1 )
20,000
5.F. cR055
OFFICE AREA
51rd PL.
= 200
FEZ5
I00
S.F. GR055
30,000 5.1=. GR055
OFFIGE AREA
4yh FL.
100
5.F. 6R055
TOTAL
- 500
PERS READ
(250 MEN, 250 V40MEN)
ANTONIO FKANYIE
FE #11640 MECH CHANDLER AND ASSOCIATES NO. BATE REVISION NO, DATE
/.� UPDAT M PE%U EL7
JOSE I MOKAGAS ARCHITECTUREA , P . a 7 c u�rrs
PE #15115 ELECT.
AA 0003050
VINIANA FIUINYIE CIUKA
PE #49585 MECH
5940 S.W. 73RD STREET
"tOG10 iV1/ 27 Street MIAMI FL 33172 SOUTH MIti� FLORIDk 33143
{3t351592-1360 • F11X 005I594-9D9
f "" . n in rs rn
?EESIGN DKA)�D DATE 7-10-03 TEL (305) 664-7992
R
PERMIT SET
DRAWING TITLE=
REVISION
NOTES AND
SCHEDULES
SCALE: NT$
DATE: JJIE A 2(=
PROJECT NO: 9902.2
DRAWING NO;
FAX (305) 669-7593
JOE NUM111 SS-145 (2003) cornuaa I(✓II '" .; 10