Loading...
02-930-076GENERAL ELECTRICAL NOTES: 1.0 GENERAL 9.0 MATERIALS AND EQUIPMENT 1.1 WORK INCLUDED UNDER THIS DIVISION CONSISTS OF PROVIDING LABOR 9.1 CONDUCTORS: CONDUCTORS SHALL BE THWN COPPER AS NOTED ON MATERIALS, APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, DRAWINGS. SUPERINTENDENCE AND SERVICES REQUIRED TO CONSTRUCT AND INSTALL 9.2 RECEPTACLES, SWITCHES k TELEPHONE OUTLETS: SHALL BE AS COMPLETE AND PROPER OPERATING ELECTRICAL SYSTEMS AS SPECIFIED, MANUFACURED BY LEVITON, HUBBEL OR APPROVED EQUAL. COLOR AND STYLE INDICATED ALL ND WORK ELSEWHERE ALLRBE PERFORMED IN ACCORDANCE WITH THE NATIONAL AS SPECIFIED BY ARCHITECT AND/OR OWNER. B ELECTRICAL CODE (NEC), SOUTH FLORIDA BUILDING CODE (SF C) AND ALL OTHER 9.3 COMPUTER OUTLETS: (IF APPLICABLE) SHALL BE AS SPECIFIED BY OWNER. APPLICABLE CODES IN THEIR LATEST EDITION. 9.4 PANELBOARDS: 2.0 EXAMINATION OF SITE A. GENERAL: INTERRUPTING CAPACITY RATINGS SHALL BE VERIFIED AND BASED 2.1 BIDDER IS ADVISED TO VISIT THE SITE AND ACQUAINT HIMSELF ON THE AVAILABLE SYMMETRICAL FAULT CURRENT GIVEN BY THE POWER WITH WORKING CONDITIONS. CONTRACTOR SHALL ACCEPT CONDITIONS AS THEY COMPANY UPON LOCATION & INSTALLATION OF TRANSFORMER. EXIST ON BID DATE. B. DIRECTORY: COMPLETE AT END OF JOB, TYPEWRITTEN. 3.0 MATERIALS C. FINISH: ANSI #61 ENAMEL OVER A RUST INHIBITING TREATMENT AFTER 3.1 MATERIALS, EQUIPMENT AND APPLIANCES SHALL BE NEW AND OF BEST FABRICATION AND BEFORE ASSEMBLY. AFTER INSTALLATION, AND BEFORE QUALITY UNLESS OTHERWISE INDICATED. ACCEPTANCE BY OWNER, ASSEMBLY SHALL BE PAINTED WITH A RUST 3.2 DETERMINE THAT PROPOSED EQUIPMENT CAN BE INSTALLED IN SPACE INHIBITING PAINT (COLOR SELECTED BY ARCHITECT). AVAILABLE. INSTALL EQUIPMENT SO PARTS ARE READILY ACCESSIBLE FOR D. NAMEPLATES: PROVIDE A LAMACOID NAMEPLATE WITH 5/16" LETTERS INSPECTION AND MAINTENANCE. EXTRA COMPENSATION WILL NOT BE ALLOWED ENGRAVED ON FRONT FACE SHOWING PANEL NAME, VOLTAGE AND PANEL FOR DISMANTLING EQUIPMENT TO OBTAIN ENTRANCE INTO BUILDING. RATING. COORDINATE TO GIVE SAME NAME AS SHOWN ON PANELBOARD 3.3 MATERIALS SHALL BEAR UNDERWRITER'S LABEL WHERE SUCH STANDARDS SCHEDULE. HAVE BEEN ESTABLISHED AND LISTED BY UNDERWRITER'S LABORATORIES, INC. E. MANUFACTURERS: GENERAL ELECTRIC, WESTINGHOUSE, I--T-E, SQUARE D. 3.4 MATERIALS, EQUIPMENT AND APPLIANCES SHALL CONFORM TO LATEST 9.5 FIXTURES: STANDARDS OF: AMCA, ANSI, ASTM, NEMA, ARI & NFPA. A. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING 3.5 USE EXTREME CARE IN SELECTION AND INSTALLATION OF EQUIPMENT TO FIXTURES AS SPECIFIED ON DRAWINGS WITH DEVELOPER AND/OR ARCHITECT INSURE THAT NOISE AND VIBRATION ARE HELD TO ABSOLUTE MINIMUM. APPROVAL. VERIFY BEFORE PURCHASE AND INSTALLATION. CORRECT OBJECTIONABLE NOISE AND VIBRATION. PROVIDE ELIMINATORS 9.6 LAMPS: ALL LAMPS USED ON THIS PROJECT SHALL BE NEW, REQUIRED FOR PROPER RESULTS. DELIVERED TO THE JOB SITE IN THE ORIGINAL PACKING CASES AND SLEEVES 4.0 PERMITS. FEES AND CODES AND SHALL BE OF THE SAME MANUFACTURER UNLESS OTHERWISE SPECIFIED. 4.1 COST FOR FEES, PERMITS, TESTS AND INSPECTIONS SHALL BE PAID FOR 9.7 BALLAST: ALL BALLASTS SHALL BE RATED TO OPERATE AT THE SERVICE BY THIS CONTRACTOR. VOLTAGE AS SHOWN AND AS SPECIFIED, PLUS OR MINUS THE DEVIATIONS WITH 4.2 INSTALLATION SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND THE ELECTRIC SERVICE COMPANY IS ALLOWED BY FRANCHISE. REGULATIONS INCLUDING: S.F.B.C., N.E.C., N.F.P.A., O.S.H.A. AND STATE, COUNTY AND CITY DEPARTMENTS OF HEALTH. 10.0 FUSES L 10.1 PART 1: GENERAENERAALL 5.0 _ COOPERATE WITH OTHER TRADES A. SUPPLY AND INSTALL FUSES IN EACH FUSED DEVICE, 5.1 MAKE KNOWN ARRANGEMENT OF WORK AND CHECK ARRANGEMENT AND B. ALL AIR CONDITIONING AND KITCHEN EQUIPMENT SHALL BE FUSED AS PER LOCATION OF OTHER TRADES TO AVOID CONFLICTS. EXAMINE DRAWINGS OF MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. OTHER TRADES TO DETERMINE EXACT EQUIPMENT LOCATIONS FOR ROUGH IN. C. INSTALL LABELS IN ALL FUSED DEVICES INDICATING PROPER SIZE FUSE 6.0 OPERATING INSTRUCTIONS TO USE. 6.1 CONTRACTOR SHALL PROVIDE TO OWNER OPERATION AND MAINTENANCE MANUALS. CONTRACTOR SHALL INSTRUCT OWNER OR OWNER'S REPRESENTATIVE 11,QJSII�NEOUS IN OPERATION OF ALL EQUIPMENT. TYPE WRITTEN LABELS SHALL BE PLACED 11.1 ALL EMPTY CONDUIT TO BE SUPPLIED WITH NYLON PULL WIRE. IN PANEL BOXES DESIGNATING CIRCUIT LAYOUTS. 11.2 ALL FLEX CONDUIT SHALL HAVE "TITE-BITE" CONNECTORS. 7.0 INSPECTION 11.3 ELECTRICAL CONTRACTOR TO INSTALL AND WIRE OUTLETS IN FIXTURES 7.1 NOTIFY OWNER TWENTY-FOUR HOURS IN ADVANCE WHEN PIPING OR WHERE SHOWN ON DRAWINGS - OUTLETS TO BE INSTALLED IN FIXTURES AFTER EQUIPMENT IS TO BE TESTED, BEFORE PIPING IS INSULATED OR CONCEALED, FIXTURE INSTALLATION. AND BEFORE TRENCHES ARE BACKFILLED. 11.4 ALL DEDICATED CIRCUITS SHALL BE LABELED AS SUCH AT OUTLET. 7.2 FAILING TO COMPLY WITH THE ABOVE, CONTRACTOR SHALL UNCOVER AND 11.5 THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND RETEST LINES, REPAIRING DAMAGE TO OTHER CONTRACTOR'S WORK, AS WELL VERIFYING THE TELEPHONE COMPANY REQUIREMENTS FOR INSTALLATION OF AS HIS OWN. SERVICE AND ADVISE THE OWNER AND/OR THE ENGINEER OF ANY ADDITIONAL 7.3 BEFORE REQUESTING FINAL PAYMENT, INSPECT INSTALLATION TO ASSURE REQUIREMENTS THAT MAY BE NECESSARY. THAT WORK IS COMPLETE AND REQUIREMENTS OF CONTRACT HAVE BEEN 11.6 THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND FULFILLED. VERIFYING THE ELECTRICAL COMPANY'S REQUIREMENTS AND SERVICE ENTRANCE 5.0 CUTTING -AND PATCHING FOR THE BUILDING TO MAIN ELECTRICAL ROOM. 8.1 UNLESS OTHERWISE INDICATED, DO NO MORE CUTTING AND PATCHING THAN REQUIRED FOR INSTALLATION OF WORK. 8.2 CUTTING OF STRUCTURAL MEMBERS OR EXPOSED SURFACE OF CONCRETE BLOCK WILL NOT BE PERMITTED. ELECTRICAL SYMBOL LIST 3 W. GROUNDED DUPLEX RECEPTACLE 20 A. 150 V. M.M. + 15" A.F.F. '4■w"' EMERGENCY LIGHT WITH BATTERY BACK UP Q- 3 W. GROUNDED DEDICATED RECEPTACLE 20 A. 150 V. M.H. + 15" A.F.F. 19 t EXIT LIGHT CEILING MOUNTED ARROW INDICATES DIRECTION OF EGRESS �Q 3 W. GROUNDED SINGLE: RECEPTACLE 30 A. 208 V. M.H. + 15" A.F.F. EQ EXIT LIGHT WALL MOUNTED ARROW INDICATES DIRECTION OF EGRESS OJ JUNCTION BOX CEILING OR FLOOR MOUNTED s SINGLE POLE TOGGLE SWITCH M.H. + 50" A.F.F. JUNCTION BOX WALL MOUNTED M.H. AS DIRECTED s a THREE-WAY SWITCH M.H. + 50" A.F.F. TELEPHONE OUTLET M.H. + 15" A.F.F. OR AS INDICATED. S 4 FOUR-WAY SWITCH M.H. + 50" A.F.F. (FUTURE CONDUIT ONLY - NO WIRING SD DIMMER SWITCH M.H. + 50" A.F.F., FOR DIMMER SIZE SEE DIMMER SCHEDULE Hp TELEVISION OUTLET M.H. +15" A.F.F. © �99Z FLEXIBLE CONNECTION. THERMOSTAT M.H. + 50" A.F.F.(REFER. TO A/C DWGS FOR LOCATION) y MOTOR OUTLET HOME. RUN TO PANEL. HASH MARKS INDICATE NUMBER OF WIRES. NO MARKS INDICATE TWO WIRES. GROUND WIRE NOT INDICATED.PROVIDE: AS REQ'D BY N.E.C. Q ELECTRICAL PANEL so SMOKE DETECTOR DEVICE. ELECTRICAL SWITCHBOARD A.F.F. ABOVE FINISHED FLOOR. FUSED DISCONNECT SWITCH W/DUAL ELEMENT FUSES G.F.I. GROUND FAULT INTERRUPTER CB CIRCUIT BREAKER (HACK TYPE IF FOR A/C UNIT) W.P. WEATHER PROOF. PULL OUT BOX W/ FUSES, FUSED PER EQ. NAME PLATE A.G. ABOVE GRADE. 30 b INCANDESCENT FIXTURE OUTLET CEILING MOUNTED. NUMBER INDICATES M.H. MOUNTING HEIGTH. CIRCUIT, LETTER INDICATES SWITCHING ARRANGEMENT EM. CONNECTED TO EMERGENCY SYSTEM. FQ INCANDESCENT FIXTURE OUTLET WALL MOUNTED M.H. AS INDICATED N.F. NON -FUSED FLUORESCENT FIXTURE OUTLET STRIP 40 60 A. RATING FUSED AT 40 A_ DUAL ELEMENT FUSES. 60 FLUORESCENT FIXTURE OUTLET CEILING MOUNTED STRIP CONNECTED TO EMERGENCY CIRCUIT OR NIGHT LIGHT CIRCUIT LIGHTING FIXTURE SCHEDULE TYPE USE MANUFACTURER CATALOG N0. LAMPS TOTAL WATTS VOLTS MOUNTING ® 0� PARKING 4' STRIP LTS COLUM51A C54-232 - BS-GLR CSWG4-AL-DL 2-F032 10 W 120 SURF / PEND PARKING EMERGENCY C54-232-E58-GLR SURF / PEND 4' STRIP LTS COLUM51A CSWG4-AL-DL-850 2-FIO32 10 W 120 W/ BATTERY BALLAST ~ STAIRS 4' STRIP LTS COLUM51A W4-232-E58-GLR-8250 2_F032 10 W 120 WALL MTD. W/ BATTERY BALLAST DO ® CORRIDOR 2x2 COLUM51A 22-232N(oG-FSA12-E58-GLR 2-1=032 10 W 120 LAY -IN FIXTURE 0 EMERGENCY COLUM51A J22-232N&G-FSA12 E58-GLR-550 2-F032 �0 W 120 LAY -IN FIXTURE CORRIDOR 2x2 W/ BATTERY BACKUP 0 FRONT ENTRY LOUIS POULSEN SKOT 116SKT-MAX-562/591 1-10OMH 100 W 120 WALL MTD. O OUTSIDE COVERED PORCH LOUIS POULSEN SKOT 1.16 5KT-MAX- 562/591 I-100MH 100 W 120 WALL MTD. J 0 LOBBY AREA HI -HATS PRESCOLITE CFT632HEB-STF602-F 1-42 PLT 50 W 120 RECESSED FLUORESCENT 00 LOBBY AREA BY OWNER BY OWNER - - 120 RECESSED CHANDELIER FLUORESCENT L O O EXTERIOR BY OWNER CFT4632HE15-57602 _ 150 W 120 RECESSED HI -HAT SL-F-DL FLUORESCENT LOBBY EMERGENCY PRESCOLITE CFT-632HEBEM-STF602-F 1-42PLT 50 W 120 RECESSED FLUOR. HI -HAT W/ BATTERY BACKUP ® O BATHROOM PRESCOLITE 8-ST312A 2-26PLT 64 W 120 RECESSED AT F 2R26PL FLUORESCENT �0 ELEVATOR LE AT R PIT LIGBATHROOM WIDE / EXCEL RLW-26HFLGC-4 - 32 W 120 WALL MTD. COVE 4 STRIP COLUMBIA CS4-232-EB8-GLR. 2-FO32 70 W 120 CLG. MTD. 0 R + LOBBY WALL SCONCE BY OWNER BY OWNER 120 CLG. MTD. \�/ SITE LAMP POLES WASHINGTON POLE BY ARCHITECT/OWNER 1-115MH 190 W 120 15' POLE 0 FRONT COLUMNS LOU15 POULSEN SATURN 1.10 SAW-MAX-15-WHT 2/18W 36 W 120 WALL MTD. EMERGENCY DUALITE LZ2D-H 2-10W MR-16 10 W 120 WALL MTD. BATT. LT. EXIT W/ DUALITE LGXRWE LED 10 W 120 UNIVERSAL BATTERY EM DESIGNATION ADDED TO ANNY FIXTURE AND OR SHADE REG2UIRED EMERGENCY BALLAST FOR FIXTURE. OWNER/DEVELOPER: THE VCFAW- RAMOn COMPANY SUITE 400 4960 S.W. 72 AVENUE MIAMI, FLORIDA 33155 305.662.1421 PLAZA 57 730o S.W. 57 COURT CITY OF SOUTH MIAMI SOUTH MIAMI, FLORIDA 33143 NORTH ELECTRICAL ROOM - FIFTH FLOOR SOUTH ELECTRICAL ROOM - FIFTH FLOOR Elm-f`►d F. 3 1204HN-1,3,5 (") O. 1z 4HN-14 PNL 4HN F-1 I@@m- MAIN NORTH ELECTRICAL ROOM - FOURTH FLOOR SCALE :1/2' =1' - 0' 0 0 (L,0CAT;__n 0 Ist I-t nop I=1 1=G Iph'1) (2-SECTION) 400A. M.L.O. PANEL $$H„ 120/ 208V. 3 0 4 W. CKT 1 S E R V E S C.B. P K.V.A. WIRE-COND CKT SERVES C.B. P K.V.A. WIRE-COND 1 NORTH STAIR LTG 20 1 1.1 412-16' 2 EXTERIOR LTS. 20 1 1.3 *12 -1/2' 3 SOUTH STAIR LTS 20 1 I. 1 412-Aix' 4 EXTERIOR LTS. 20 1 1.3 #12-V ' 5 EXTERIOR LTS 20 1 1. 5 012-Ii2' 6 SPACE 7 SERVICE LTS 20 1 1.5 412-1•2' 8 LIGHT POLES 20 1 1.3 SEE PLANS 9 TEMP. LTS. 20 1 1.0 412-1/2' 10 LIGHT POLES 20 1 1.1 SEE PLANS 11 GARA 4 LTS. 20 1 1.5 412-1i2" 12 GARAGE LTS. 20 1 1.5 +12-1i2` 13 GARAGE LTS. 20 1 1.2 12 -1/2' 14 GARAGE LTS. 20 1 1.2 412-1i2, 15 GARAGE LTS. 20 1 I.5 M2-Ii2' 16 GARAGE LTS. 20 1 1.5 #12-1/2' 17 GARAGE LTS. 20 1 I. 5 412-Ii2' 18 19 EXTERIOR LTS. 20 1 1.3 12 -1/2' 20 STOW LIFT STATION 20 3 5. 6 +12-1i2' 21 GARAGE LT5. 20 1 1.5 412-Ii2' 22 23 ELEV PIT LTS. 20 1 1.0 012_I/2 24 GARAGE LT5. 20 1 1.0 412-1/2` 25 26 GARAGE LTS. 20 1 0. 9 412-Ii ' 27 A/C L055Y 40 3 9. 5 48-1/2' 28 GARAGE LTS. 20 1 1.1 -I1/' 29 v30 GARAGE LTS. 20 31 EF-2 20 1 1.2 412-I/' 32 EF-2 20 1 1.2 412-V2' 33 EF-2 20 1 1.2 412-I/2' 34 EF-2 20 1 1.2 412-1,12' 35 EF-2 20 1 1.2 012-1/2' 36 EF-2 20 1 1.2 412-112' 37 GARAGE LTS. 20 1 1.5 412-Ii2' 38 EF-2 20 1 1.2 *12-1/2' 39 GARAGELTS. 20 1 1.4 40 41 GARAGE LTS. 20 1 1.5 #10_1/2' 42 SPACE 43 EF-2 20 1 1.2 44 SPACE 45 SPACE 46 SPACE 47 SPACE 48 SPACE 49 SPACE 50 SPACE 51 SPACE 52 SPACE 53 SPACE 54 SPACE 55 61 SPACE *12 -1/2 56 62 SPACE - CONWs0TED K.V.A. = (s) TOTAL AMPS = (#) FEEDER : 2-2' C. EA. Wi 4 M 3/0, 144 G 0 THRI PHOTOCELL (*)SEE CALCULATIONS CALCULATIONS FOR PANEL H LIGHTING LOAD 31.1 KW 9125 io 38. 9 KW LARGEST MOTOR 9.5 KW e125i© 11. J KW REST OF LOAD 54. (o KW a100% 54. (o KW TOTAL LOAD 105. 4 KW 105. 4 KW 0 20& 3 PHASE = 293. 0 A. :..... R. 4HS-10 `` ".. 4HS-1,35 �• SLEEVES ; .� 0) O4HS-14 -- PNL 4HS 100 - MAIN M Mims - _ •;, ' i ;gin el SOUTH ELECTRICAL ROOM - FOURTH FLOOR SCALE-1/2'-1'-0' (LOCATED • 1st FLOOR FLFG_ RM-) PROPOSED HOUSE 2-2'EMPTY CONDUITSLEE S METER CAN W/ 11/4'C TO BE COORDINATED W/ t L REQUIRI=MENT5 2 a PV DUCT -FOR i FP E L PR IMA Y SERVICE R_- ER - _ 150 A. M.L.Q. PANEL "H2" 120 i 208V. 3 • 4 W. CKT S E R V E S C.B. P K.V.A. WIRE-COND CKT S E R V E S C.B. P K.V.A. WIRE-COND 1 G3=_1 RECEPT. 20 1 0.5 012-I�2` 2 ELECT. RM. RECEPT 20 1 0.4 012-Ii2' 3 BLDG. ACCESS PNL 20 1 1. 0 412-1/2' 4 J.B. FOR F.A. 20 1 1.0 412-1/2' 5 TEL. EQUIP. REC. 20 1 0.18 412-1/2' 6 EF-4 20 1 1.0 "12-Iiz' 7 8 9 NORTH BOOTH 50 3 15.0 *6-3/4' 10 SOUTH BOOTH 50 3 15.0 45-3/4' 11 PANEL 12 PANEL 13 GATE MTR 20 1 1.0 412-1i2' 14 GATE MTR 20 1 1.0 412-Ii2' 15 GATE MTR 20 1 1.0 *12-1/2' 16 GATE MTR 20 1 1.0 12 -1/2' 17 RECEPT 20 1 0.2 412-1/2'C 18 MAN ELEC R"1 LTS 20 1 0.2 412-1i2' 19 ELEV. CA5. 20 1 0.5 *12-I6' 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 +SPACE 40 SPACE 41 SPACE 42 SPACE CONNECTED K.V.A. TOTAL AMPS FEEDER : 4 0 1/0 _2' C. CALCULATIONS FOR PANEL L LIGHTING LOAD 0. 1 KW 40125 �o LARGEST MOTOR 1. 0 KW f 125% REST OF LOAD 31.3 KW Q100io 1 VFRIFY EXACT SIZE OF G.B. FOR GUARD BOOTH W/ MANUI-ATURER (•) SEE CALCULATIONS. 0. c3 KW 1. 25 KW 31.3 KW TOTAL LOAD 39.4 KW 39, 41<11 200 3 PHASE = 109. 5 A. 4 ti �3.1 I _ -00 (E) 12' x 12' x V GUTTER FUTURE METERCAN t DISCONNECT LOCATION FOR RETAIL SPACEs ON lit FLR_ MAIN DISC NNECT 1,000 A. COLT-LOC SWITCH H2-2 H2-6- 1 H2-18 1,000 A. BOLT -LOG SWITCH MAIN T.T.B. H2-2 =E PNL 'MDP' PNL 'H' PNL 'H2' 2-3'E_C. W1 PULLWIRE TO TEL. CO. POINT OF CONNECTION (SEE RISER ON E-1) MAIN ELECTRICAL ROOM - FIRST FLOOR `f- JOSE I MORAGAS `� PE #15115 ELECT '(ZiF VMANA FRANYIE AURA !� FE f49995 MECH 10.610 IW 27 Strut HAMI FL 33172 C asz 1360 • FAX [M59027r1 eDLAL AKU1U1Y:C:1 U1C" F.A. AA OOOM 5940 S.W. 73RD STREET SOUTH MIA( % FLORIDA 33143 Guli7v u+!<Ia T M1 - 'fir 1 Cat ' . F ' ;' ; G . L, ROOMS SCALE DATE:: JUKE A 20M PROJECT NO 9902.2 DRAWING NO: A � y 1P 1-10-03 TEL (305) 669-7592 FAX (305) 669-7593 tt;:? JU r,, 103 E-8 101 NUMBER g9-146 (2003) Ccrmc;xr 2m 9