02-930-060AIR CHAMBER
CHICAGO SILL COCK
MODEL NO. 387
3/4" HOSE BIBB WITH
REMOVABLE TEE HANDLE
NON --REMOVABLE
BACK —FLOW PREVENTOR
"WATTS" MODEL No. 8--A
3/4" GATE VALVE ` ---
3/4"
FROM DOMESTIC
COLD WATER LINE
TYPICAL HOSE BIBB CONNECTION
N.T.S.
TOP OF PAVING
CONCRETE VALVE BOX ---
CAST IRON FERRULE W/CAST
BRONZE COUNTERSUNK PLUG
HEAVY DUTY 9" X 9"
ACCESS COVER
AND FRAME
�- CLEAN OUT EXTENSION PIPE SAME
SIZE AS BUILDING SEWER OR DRAIN
AND 6" MAXIMUM
BUILDING DRAIN OR SEWER
EXTERIOR CLEAN OUT DETAIL
N.T.S.
11i2' A/C CONDENSATE DRAIN
SLOPE a 1/4' PER FOOT MINIMUM
PIPE CLAMP ATTACHED TO
I J 4'x4' PT a 48' O/G MAX.
ROOF MEMBRANE-
12'xl2' HEAVY DUTY ASPHALT SHEET 4'x4'x2b GA. SHEET METAL
SCREWD TO 4'x4' PT AND 13ACKING PLATE CINDER
HOT MOPPED TO ROOF MEMBRANE ASPHALT SHEET.
A/C CONDENSATED SUPPORT DETAIL,
N.T.S.
INTERIOR CLEAN OUT DETAIL
NO SCALE
CLEVIS TYPE HANGER
SEE NOTE BELOW.
PLUMBING PIPE.
DRAIN SCHEDULE
UNIT DESIGNATION
ROOF DRAIN
AD
FD
FID
DID
MANUFACTURER
ZURN * *
ZURN
ZURN
ZURN
ZuRN
MODEL TYPE
Z-121-E
Z-533
ZB-415-65-P
Z-541
Z-158
ACCESORIES
-
-
POLISHED BRONZE
CAST IRON
POLISHED BRONZE
TYPE
LOW SILHOUETTE
DECK DRAIN
FLOOR DRAIN
H.D. FLOOR DRAIN
DECK DRAIN
DESCRIPTION
COATED CAST -
COATED CAST -
bx6 6Q. ADJ.
12' # TOP WITH
8" 0 TOP WITH
IRON, WITH CAST
IRON 50TTOM
STRAINER TOP
REMOVABLE
REMOVABLE
IRON DOME
OUTLET
HEELPROOF
SEDIMENT C.I. 5UCKET
SHALLOW SEDIMENT
TRAP PRIMER
HEAVY DUTY GRATE
CAST-IRON BUCKET
LOCATION
ROOF
PARKING
TOILET ROOMS
MECHANICAL AREA51
PORCH AREA
No. 4253 ADJUSTABLE
LEVEL CLEAN OUT
I
PLUMBING FIXTURE SCHEDULE
BRONZE TOP WATERTIGHT
SYMBOL
FIXTURE TYPE
TRAP
SIZE
C.W.
H.W.
DESCRIPTION
MODEL
FAUCET -TRIM
EX
ELEC. WATER COOLER
11�4'
1'2
WALL HUNG ELECTRIC WATER COOLER
STAINLESS STEEL FINISH
MFG. HAWS
HOTEL HC3F1d
WALL HANGER P-TRAP
AND SUPPLY
WC
WATER CLOSET
WALL HUNG
4'
IN
-
ELONGATED WATER SAVER, VITREOUS
CHINA, SIPHON JET FLUSHING ACTION
AFWALL 2258.125
WALL HUNG
OLSONITE OPEN FRONT SEAT LESS COVER
n5, SLOAN ROYAL FLUSH VALVE 4 CARRIER
WC-H
WATER CLOSET1
WALL HUNG L
41
_
ELONGATED WATER SAVER, VITREOUS CHINA
SIPHON JET ACTION, HIGH FOR WHEELCHAIR
AFWALL ADA 2258.125
WALL HUNG
OLSONITE OPEN FRONT SEAT LESS COVER
No. 95, SLOAN ROYAL FLUSH VALVE 4 CARRIER
SLAB
UR
URINAL
2'
34,
-
VITREOUS CHINA WASH -OUT
WASHBROOK 6501.010
SLOAN ROYAL FLUSH VALVE
No. 186, WALL CARRIER
LAV-1
LAVATORY
11�4'
'�s'
VITREOUS CHINA WITH FRONT
OVERFLOW FAUCET LEDGE
LUCERNE O3$6.OI5
HERITAGE LAV. FAUCET 6801000 W/GROWN
HANDLES P-TRAP 4 SUPPLY WALL CARRIER
LAv-2
LAVATORY
11/4'
1/ ,
-
VITREOUS CHINA WITH FRONT
5ELF-R71 11NG, FRONT OVERFLOW
,AQUALYN 04152113
HERITAGE LAV. FAUCET 6801000 W/GROWN
HANDLES P-TRAP 4 SUPPLIES
LAV-H
LAVATORY L
114'
1/z '
-
VITREOUS CHINA WHEELCHAIR
LAVATORY
PATIENT LAVATORY
9140.013
HERITAGE LAV. FAUCET 22381213 DRAIN
ASSEMBLY #1123.018 P-TRAP 4 SUPPLIES
JS
JANITOR SINK
11i2'
I/z'
-
ENAMELED CAST IRON DRILLED
BACK RIM GUARD
AKRON SINK
1b95018
HERITAGE FAUCET 8340234
AND 1198116 P-TRAP
:R ROD FASTEN TO
.TUBE PER SPECIFICATION
NOTE:
PROVIDE COPPER HANGERS FOR
COPPER PIPE. (NOT COPPER CLAD)
OVERHEAD PIPE SUPPORT
NO SCALE
*ACO DRAINAGE CHANNEL PER PLAN
(SLOPE BOTTOM PER PLAN)
PROVIDE HEAVY DUTY 477 ADA DUCTIL
IRON SLOTTED GRATING. SEAL ALL
SPLICES AND END CAPS
PER MANUFACTURER.
CONCRETE FLOOR SLAB
OWNER/DEVELOPER
THE PLAZA 57
:KFARD- MAW01111
COMPANY 7300 S.W. 57 COURT
SUITE 400
4560 S.W. 72 AVENUE
MIAMI, FLORIDA 33155 CITY OF SOUTH MIAMI
305.662.1421 SOUTH MIAMI, FLORIDA 33143
STEEL REINFORCING
PER MANUFACTURERS
MANUAL.
SAWCUT SLAB
'I POURED IN —PLACE TRENCH.
SEE ARCHITECTURAL DETAILS.
TRENCH DRAIN DETAIL
NTS
NOTE: 1- ALL FIXTURES ,AND TRIM ARE MANUFACTURED 5Y AMERICAN STANDARD UNLESS NOTED OTHERWISE
2-ALL FIXTURES MAY BE SU5MITTED AS SCHEDULED OR AS APPROVED EQUAL
4'SS_\
6 "RWL
— 3' VENT.
3/4'C-W-
WET COLUMN
O(Tye.)
TYPICAL OFFICE WET COLUMN PLAN
N.T.S.
T
TYPICAL PIPE PROTECTION IN PAfftLN-
m" ING
N.T.S.
PLUMBING NOTES
1.0 GENE
1.1 PROVIDE ( FURNISH AND INSTALL) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
SOUTH FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
1.2 SCOPE OF WORK
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY COLLECTION.
B. GREASE WASTE COLLECTION AND GREASE TRAP.
C. DOMESTIC COLD WATER
D. RAIN WATER COLLECTION
E. AIR CONDITIONING CONDENSATE.
F. C.W. PIPE FOR ELECTRICAL GROUND
1.3 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED.
1.4 VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATION OR INSTALLATION. COORDINATE REQUIREMENTS
TO AVOID INTERFERENCE WITH OTHER TRADES.
1.5 NATURE OF DESIGN DRAWINGS:
DESIGN DRAWINGS ARE DIAGRAMATIC AND DO NOT INTEND
TO SHOW EVERY FITTING, ELBOW, TRANSITION, ETC. THAT
WILL BE NECESSARY FOR A COMPLETE OPERATIONAL SYSTEM
AS REQUIRED BY THESE SPECIFICATIONS.
1.6 COORDINATION DRAWINGS:
PREPARE 1 /4" SCALE COORDINATION DRAWINGS SHOWING
MAJOR SYSTEM COMPONENTS FOR A/E APPROVAL.
1.7 SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
1.8 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
2.0 MATERIALS
2.1 PROVIDE SHUT—OFF VALVES FOR EACH FIXTURE AND AIR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMANCE OF THE SYSTEM.
2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OR OTHER PIPING OF DISSIMILAR METALS.
USE CLAMPS AND FASTENERS OF SIMILAR METALS OR
ISOLATE FROM PIPING. ISOLATE PIPING FROM CONCRETE
SLABS AND WALLS TO PREVENT CORROSION.
2.3 PIPING
2.3.1 DOMESTIC COLD AND HOT WATER:
UNDER GROUND BELOW BUILDING:
SOFT COPPER TYPE "K" OR "L" WITHOUT JOINTS.
ABOVE GRADE:
HARD DRAWN COPPER TYPE "M" WITH SOLDERED JOINTS.
VALVES:
125 PSIG MIN. WOG BRONZE VALVES
HOT WATER INSULATION:
1 " PRE —FORMED GLASS FIBER W/FIRE RATED A.S.JACKET.
2.3.2 SANITARY WASTE AND VENT:
UNDER GROUND BELOW BUILDING:
CENTRIFUGALLY SPUN CAST IRON PIPE NO —HUB FITTINGS
SCH. 40 P.V.C. D.W.V. PIPE do FITTINGS MAY BE USED
WHERE ALLOWED BY THE LOCAL JURISDICTION.
ABOVE GRADE:
CENTRIFUGALLY SPUN CAST IRON PIPE NO —HUB FITTINGS
SCH. 40 P.V.C. DWV PIPE AND FITTINGS MAY BE USED
WHERE ALLOWED BY THE LOCAL JURISDICTION.
2.3.3 RAIN WATER COLLECTION:
SAME AS SANITARY WASTE AND VENT PER 2.3.2 ABOVE.
2.3.4 A/C CONDENSATE: PVC SCEDULE 40 PIPE AND FITTINGS.
2.4 NO PVC PIPING MAY BE USED INSIDE RETURN AIR
AIR CONDITIONING PLENUMS.
3.0 EXECUTION
3.1 SEPARATE ALL PIPING FROM CONCRETE BY USING
SLEEVES THRU WALLS AND FLOORS. CAULK ANNULAR
SPACE WITH APPROVED FIRE RATED CAULKING.
3.2 PROVIDE FIRE SAFING AT ALL PIPING PENETRATIONS AS
PER DETAILS PROVIDED.
3.3 DO NOT INSTALL PVC PIPING IN CEILING SPACES INTENDED
FOR RETURN AIR PLENUMS.
3.4 DO NOT INSTALL ANY PIPING ( WATER, SANITARY, VENT,
STORM, ETC.) INSIDE ELEVATOR EQUIPMENT ROOMS.
TOILET
FACILITY OCCUPANT
LOAD
CAS PER TABLE 46-5-1 )
20,000 5.1^. 6RO55
OFFICE AREA
5rd FL.
- 200
PER5
100 5.F.GRO55
30,000 5.F. 5RO55
OFFICE AREA
4th FL.
300
PER5
100 5.F. 6?R055
TOTAL
= 500
PER5 READ
(250 MEN, 250 WOMEN)
.......
ANTONIO FRANYIE
PE #11640 MECH CHANDLER AND ASSOCIATES NO. BATE REVISION NO. DATE
UPDAT® PERU >E
loSE I MORACAs ARCHITECTURE, P.A. 10-0s3 C) DO IJN=
PE #15115 ELECT.
' M 0003050
VIVIANA FRANYIE CIUKA
�!► FE #499#5 MECH
59
� 106101 NW 27 Street MIAMI FL 33172 � SW. � STREET
SOUTH MIAML FLOlUDA 33143
C00559243G0 •FAX Ci05) 'JZ79
i rs m
LpySE IGN DRAWN DA 0-03 TEL (305) 669-7592
RP FAX (305) 669-7593
J01 NUMM 99-145 (2003) corVMHT tiw
PERMIT SET
DRAWNG TITLE:
NOTES AND