Loading...
BRB21_0742PROPERTY INFORMATION REMODELING OF EXISTING HOUSE INTERIOR AREA REMODELING AREA 566 GROSS SQT 'DEMOLITION WORK INCLUDES: THE DEMOLITION OF EXISTING INTERIOR PARTITIONS AS SHOWN ON THE PLANS, DEMOLITION ALSO INCLUDES ALL ELECTRICAL, PLUMBING AND MECHANICAL INSTALLATIONS IN THE AFFECTED AREAS. ALTERATION AND ADDITION WORK INCLUDES: THE ALTERATION OF THE EXISTING GARAGE AREA ADDING TWO BEDROOMS AND ONE BATHROOM, MASTER BATH AREA, AN OTHERS ELEMENTS SHOWN ON THE PLANS. STRUCTURAL WORK INCLUDES: NEW INTERIORS WALLS AND FOUNDATIONS FOR THE NEW EXTERIOR WALL WHERE THE EXISTING GARAGE DOOR WAS. SOME OF THE EXISTING OPENINGS WILL BE MODIFIED TO ALLOW FOR NEW DOOR AND WINDOWS. L SEE STRUCTURAL DRAWINGS FOR MORE DETAILS. MECHANICAL, ELECTRICAL AND PLUMBING WORK INCLUDES: SEE M.E.P. DRAWINGS FOR MORE DETAILS. APPLICABLE CODES -FLORIDA BUILDING CODE 2021 SEVENTH EDITION INCLUDING CODES AND STANDARDS NOTED ON THIS CODE TYPE OF CONSTRUCTION TYPE III -A (CHAPTER 6 - SECTION 602.3) AS.PER FBC 2021-BUILDING USE AND OCCUPANCY CLASSIFICATION R-3 (CHAPTER 3 - SECTION 310.5) AS PER FBC 2021-BUILDING CLASSIFICATION OF WORK ALTERATION - LEVEL 2 (CHAPTER 5 - SECTION 504) /ADDITION AS PER FBC 2021-EXISTING BUILDING NOTICE IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, SECTION 553.79(10), FLORIDA STATUTES, EFFECTIVE 7 / 10 / 87 NOTES j IF APPLICABLE, A SEPARATE PERMIT WILL BE REQUIRED FOR: - L DOOR AND WINDOWS, GARAGE DOORS, ELECTRICAL, MECHANICAL, PLUMBING, SWIMMING POOL, DRIVEWAY APPROACH, SIDEWALK,, FENCING, LANDSCAPING AND IRRIGATION, TREES REMOVAL, SECURITY SYSTEM, LOW VOLTAGE, WATERPROOFING, ROOFING SYSTEMS, HANDRAILS, SAFEGUARDS, STAIRS AND GATES. i F+ - - m LIST OF PLANS Ri { i I m z A-0 SURVEY - GENERAL NOTES S-lI STRUCTURAL GRAL. NOTES i , A-1 EXISTING &DEMOLITION FLOOR PLAN S-2 FOUNDATION & GROUND FLOOR PLAN 4 LINK FENCE A-2 EXISTING &DEMOLITION ROOF PLAN S-3 ' ROOF FRAMING PLAN I HIGH CHAIN I A-3 EXISTING & DEMOLITION ELEVATION S-4 DETAILS - � � ._..- - �, A-4 NOTES S-5; ELEVATIONS. I 7 A-5 PROPOSED SITE PLAN M-1 MECHANICAL GRAL. NOTES A-6 PROPOSED FLOOR PLAN M-2 MECHANICAL FLOOR PLAN --z—n S00021o49eE 111■ 4 ADJACENT ASPHALT -„ A-7 PROPOSED ROOF PLAN E-1 ELECTRICAL GRAL,NOTES O O 0 zXO DRIVEWAY A-8 PROPOSED ELEVATIONS E-2 1ST FLOOR ELECTRICAL PLANDR V00C - Z A-9 PROPOSED CROSS SECTIONS P-1 PLUMBING GRAL. NOTES o�p i I LOT 4 BLOCK 3 CN31 p-oo — � � � A-10 PROPOSED REFLECTED CEILING PLAN P-2 PLUMBING FLOOR PLAN m ,� I ( � , �.,� , _ m ,. 1 = FF A-11 DOORS &WINDOWS SCHEDULE P-3 SANITARY FLOOR PLAN I I n TRANQUILITY ESTATES n o N s A-12 EXTERIOR DOORS , _ A-13 WINDOWS I , I i P.B. 78, PG`. 64 � A-14 INTERIOR DOORS I , A-15 TYPICAL DETAILS I 4 A-16 TYPICAL DETAILS I I I , - A-17 TYPICAL DETAILS - FENCE' I I � I Mi i D D JI FLY, P; TYRJ F TbON nSCOP�QFWORKpAPPLICABLE CODE NOTES AND LIST OF PLANS 4 092 017 U j b - • SCALE 1/8":1'-Off A- 0 . pdf E , x DEBASA, JOSE 8/2/2021 10:27:56 AM DERM Approved ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Heman Santarcangelo, Architect NCARB AR# 96867 CV r M M O Q J 'Q U W- U) C W cM Z to U U3 o w z I*-- _ QD 0 J W ALL DRAWINGS AND WRITTEN ` -. MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 H 8 9 10 Date 8-JAN-21 Drawn: H.S. Designed by: H.S. Checked by: H.S. SCALE: NOTED A-0 SHEET PROPERTY ADDRESS: 6790 SW 63rd STREET, SOUTH MIAMI, FL 33143 0:6 P's 03,2P U FLOOD ZONE INFORMATION: COMMUNITY NO. 120658 PANEL NO. 0458 SUFFIX: L FIRM DATE: 09-11-2009 FLOOD ZONE: X LEGAL DESCRIPTION: EDGE OF PAVEMENT LOT 3, BLOCK 3, OF "TRANQUILITY ESTATES ACCORDING TO THE PLAT THEREOF r U) Z W AS RECORDED IN PLAT BOOK 78, AT PAGE 64, OF THE PUBLIC RECORDS OF 0 MIAMI-DADE COUNTY, FLORIDA. LLI MFPUBLIC��RIGH W& .............. 0 FOU SURVEYOR'S NOTES: I E INIT 5 NO LEGAL DESCRIPTION WAS FURNISHED BY THE CLIENT. co Z 0 co co 0 LEGAL DESCRIPTION SUBJECT TO ANY DEDICATIONS, LIMITATIONS, ED RESTRICTIONS, RESERVATIONS OR RECORDED EASEMENTS. EDGE OF PAVEMENT Ln SOUTH RIGHT OF WAY LIN L6 L6 cm Cq FOUND 1/2"0 THERE MAY BE LEGAL RESTRICTIONS ON THE SUBJECT PROPERTY THAT ARE NOT too M­ 15'PARKWAY r-­IRON PIPE FOUND 1/2 (NO I.D.) BLOCK SHOWN ON THE MAP OF SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS IRON PIP' S 0 OF MIAMI-DADE COUNTY, OR THE RECORDS OF ANY OTHER PUBLIC AND PRIVATE A A CORNER (NO I.D.) EAST 112.50, 225.00'(R&M) ENTITIES AS THEIR JURISDICTIONS MAY APPEAR. Fh U-1 LU too w LU -.1 FOUND 1/2 'Z n N_ THIS SURVEY WAS CONDUCTED FOR THE PURPOSE OF A BOUNDARY SURVEY Z RON PIPE 5� LOT 5, BLOCK 3 FE Z CK, (NO I.D.) ONLY 7; "TRANQUILITY ESTATES" :3= Z 0 i�� LU 0 1-2 'af, !�E a. THE ELEVATIONS OF WELL -IDENTIFIED FEATURES AS DEPICTED ON THIS SURVEY P.B. 78, PG. 64 CL co 05 Mw CD AND MAP WERE MEASURED TO AN ESTIMATED VERTICAL POSITIONAL ACCURACY. OF 1/10 FOOT FOR NATURAL GROUND SURFACES AND 5/100 FOOT FOR Cn k., DRIVEWA Wm� < HARDSCAPE SURFACES, INCLUDING PAVEMENTS, CURBS AND OTHER MAN-MADE 'ILE A-E > 601 FEATURES AS MAY EXIST. UU a .�WALK 0 Uj CLO W 1- :1 Z WELL -IDENTIFIED FEATURES AS DEPICTED ON THIS SURVEY AND MAP WERE M :::z gjE S>2 Z LU —14.0 Cn UMJ LU MEASURED TO AN ESTIMATED HORIZONTAL POSITIONAL ACCURACY OF 1/10 FOOT �:::P0R6H:::::: X_ 'm cO 0 M �.- d i 0 17 /2 5' .5' -J 0 Uj ca Z TE 46. __j LU UNLESS OTHERWISE SHOWN. M�-L'�-ww it M _wLU —14.4 4( X LU LU < LU tul __j W C14 0 _,0 �2 P: <' P V 5 5 LU w THE MAP OF SURVEY IS INTENDED TO BE DISPLAYED AT THE STATED GRAPHIC 1 -1 11 11 . N _11� Lq LH SCALE IN ENGLISH UNITS OF MEASUREMENT. ATTENTION IS BROUGHT TO THE 3: 0 Uj M 0: FACT THAT SAID DRAWING MAY BE ALTERED IN SCALE BY I THE REPRODUCTION X DEN on I- i�:=i =i::i :zi?:: §E X—X—X— PROCESS Cn CD Ul) cm w I - _j Z ALL MEASUREMENTS SHOWN ARE IN THE UNITED STATES STANDARD FEET 3,BL 3� Lr) F_ >c 02 LrUL LZL, ow X qql- Ad N w to ZLLMZZ�Iq qr— �e C/) 0 R!� C Cf) QUI EV ) < LCU, 0�- Uw, - M Cn 0= I-__ - >W- w d 0 0 M E 65 0 F_ �_ 0 SHOWN ELEVATIONS ARE REFERRED TO N.G.V.D. OF 1929. 0 W LU LU 0 Uj Uj 11.1 1­ 0 7�k, P 64/ IL Of or- ER w U') C0 CIO U) j >- CL C L If 11 11 If M cr) M F- 00 qqT - 00 bt;ALE: 1 2 0 fo? Z A ­4 _j i� r-� % I + 40* ,ZF __j r-� --J gof 9 LU;� Cn LU ­t — THE SURVEYOR MAKES NO REPRESENTATION AS TO OWNERSHIP, POSSESSION I � 01 FF/E' w on on on on �_ =) 06 C4 Ej V� 4.2 M LU OR OCCUPATION OF THE SUBJECT PROPERTY BY ANY ENTITY OR INDIVIDUAL. 0 4. whe ;k i%rt 0 C3 3.6WV CNI 0 _j Z 0 CD 1= ­j SUBSURFACE IMPROVEMENTS AND/OR ENCROACHMENTS WITHIN, UPON, Z C6 X Z LU ACROSS, ABUTTING OR ADJACENT TO THE SUBJECT PROPERTY WERE NOT UU Z 07 U) z- 0 "S LUUA tL) ANU AK NU 6NUVV Lu Lu x 0 NOT VALID WITHOUT THE ELECTRONIC SIGNATURE AND DIGITAL SEAL AND /OR THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR x LL Z AND MAPPER. ADDITIONS AND DELETIONS TO THIS MAP OF SURVEY BY OTHER 29.65' THAN THE SIGNING PARTY ARE PROHIBITED WITHOUT THE WRITTEN CONSENT OF Z Zoo THE SIGNING PARTY. POOL THIS MAP OF SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE JACUZZ ENTITIES NAMED HEREIN AND THE CERTIFICATION DOES NOT EXTEND TO ANY UNNAMED PARTY. x X CERTIFY TO: -1 CLAUDIO HERNAN KAPUSTA & GERALDINE SCHNAIDER ON P ­03 6'UTILITY EASEMENT '4'HIGH CHAIN LINK FENCE SURVEYOR'S CERTIFICATION: IN MY PROFESSIONAL OPINION, THIS "BOUNDARY SURVEY", MEETS THE L 61 uTrrfV EASEMENT STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF WEST 112.50 PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-1 7.05 FLORIDA FOUND 1/2110 ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. IRON PIPE LOT 8, BLOCK 3 LOT 7, BLOCK 3 RON PIPE FOUND 1/2"0 AND, IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELI ffl. I I I ///// (NO I.D.) "TRANQUILITY ESTATES" "TRANQUILITY ESTATES" (NO I.D.) BA EZ C/ &// P.B. 78, PG. 64 P.B. 78, PG. 64 3600 SURVEYING AND MAPPING, LLC '\ 1�� \ \G E N s,6 0;/ FLORIDA CERTIFICATE OF AUTHORIZATION NO. LB 6356 x tE Zw w >w 0Z U) ro= �2 Uj Uj U_ 0 u0j OZ Z LLJ 0 Z:� Z _jUjLU Cni�oz OW Z =: =:) M = LLJ Z 0 2 W M Uj �!5 LU Uj Mo Z Z 9 I'L 2 f'L Uj w w C4 IL do C< Lu LOU ��7 LL, Lu 0 _j ;> 'Lu zm!) L U Lu Iz- EZL ox 0 1. w �u !<j Uwj U, - � 2022 ow tL _j L.0 0 — w Z �- 0 w g >_ LLI M F-0=0 min U �- L) OZ LU Z Z M Z Z LU LLJ =3 w 5 5 =5 cy) 0 0 Lu _j -0 LL _j 0 8 C-) U, LLI I, a: 2 59 0 6 ID it it it 11 H 11 11 11 If 11 11 d If. M Z a: _j 00 LL: LL LL LL LL: 0 C-) Q CL C-9 w �!e W LLI 9 C-) I CO) Z0 0 Z Z LU Z LLU wZ Z LL. Lu U'- L M CD CJ < 23 -J K Z Z 2 M 1.11 W _j LLI 0 Z �e W 0 W_ LU mot) w Z L) 0 L) M Uj Z 0 i�, =: < < M M C-) 0 0 0 0 0 LL OD LL =_j _j 11 Digitally signed by Oscar E Baez REVISIONS AND/OR UP -DATES Oscar E Baezn;;e: 2021.05.05 09:49:26 -04'00 NO. L 3600 SURVEYING AND MAPPING, LLC ORIGINAL S5034 FIELD DATE 04-30-2021 OSCAR E. BAEZ-CUSIDO, P.L.S. STATE OF Land Surveyors - Land Planners REGISTERED SURVEYOR AND MAPPER NO. 5034 2935 S.W. 82nd Avenue MIAMI, FLORIDA 33155 M &TA1ECff&dkRIDCounty Department of Re44i �'f,\-4*�t��conomiC ReSources Job Cop JOB No 2104-0050 0 21017036 - 9/3/2021 1:20:03 PM 1111D LAND y PHONE: (305) 265-1002 SURVEY.pdf � Y�g. .y. my� ,<+,�s.,Y.:1�'�, - 'c e .�� �"'rm+.�*✓s�'r��;� • • • • • • • • • • � • gI• � taIly sfgned. . UNDER SEPARATE PERMIT DI �, . ° _ >: c,r`, ��. � to ���" �����`�� .� � �. • u • • s • • • • • • of Fc b H ERNAd�I . :00. pllM17faks�;A}r�X s �; • ••:� SANTARGrANGE ... .... - N 2 x r' sue' N SANTARC,q ... r • - = :"'�'t-:�-.ru�zr',rz� �Q' ,_q ••r• • •s••• s•• • •s•• • n + w 25'-011 10 FEET TRIANGLE OF VISIBILITY � 'K . * ' "� "t /� ,O 1 1 11 s,¢.�G, � E�2, ,,,r>a` '� �y�. z-".. �'"'c�wa.:e '_.`,�.. r.: '�"� • L saf., 5 0 , o_ 20 -7 %n CD SHALL BE KEPT CLEAR OF VISUAL � � •� AR96867 I� NEW SEPTIC TANK - _I OBSTRUCTIONS BETWEEN A HEIGHT m' �, F�`'Ircl I. .`� y . n OF 2.5 FEET TO 8 FEET ABOVE r n -�.,lc •3r,r„`",r 3;. '1 s V'�('� •• . •`�� „ate 110' D10. E SET K GRADE.. U»*,,% a �• ! t w'`�^'.x)a�� }Pf,n' z"" `! r*�c" r"'g'"a£'Lt; �%- •,. ;���`.`..,+zzz... "",��' a+M.:,"raw,.rr.: 10' SI SETBACK t 10' SIDE SETBACK SI C ; 4 z c REo A�� 2021 07 2s • • 11:41:29 04 00 49- 6 - 301 -0 s �, qy"`r' f :�.y., a 5• ,s a Y>,a�„y' 4*'r�a'`��.z ? e t` i I NEW DRAIN qj LD g a � a •� w+ r< >�ir ,xa. rrxx�' 4 ,,`''"' sm yn'w 5 z�ar � - V - - - - - i}'F¢ •nr ,a'..,.�� r• ��:x;; �tw4`���`'ea�t mf"a.'z� u�� w .'., s"�,x..,c^ i � I w - - - - - - a �"..�'"�``�" ��r``�"vw"'`y �' •�' �t wa �"�� r'�'"�r�. "'s--�,.rra , '1 ^1 v:,r<7•\ a�<y �lv I.,r > J�`��Tu .l .>�.: �TY>,r ;4r� ,.- cx...:.� ,. r. *.z, Y" .,, u.�. s c�, . ;; '�#s a^`�aU. f,a ,r ,. I N .. s^ \. , . ... ,, .,, ":,,c .Tt Z� "�: : <: t.� 2• �, rt'� . F - ; . `�.. _ � -' z, ...�' .- Wit. '.wT' ,,: - -tt' 15311 1 m - �..,;.Y >^>;>_-I />.v� r.,� ,�>,CS�-,� �v>-r.;, � Y r yS, ,S� -�t1, ���TT"'! L�'2" sa a k �r-� s e�, J>£'s^ ✓ I -1 1 n _ -v _` ,iv' � rr!'v: `- ^<,�_....\ ,''i? : .v _ ./r, ,,\ :,2'`�.�.�'„ -y. ��., y ; `<` -,<.' f "a } , *� >t',;,", i 6,w.c'z '.'`*:x�•'-'Mk:+',','x . - 10 - zn - - - ?.,`.>.0 - .;l`� "1�4' ."C '' '::,T :\ t ;.� i r< \ -,� ;v ?,..�'~�;� s,..<"'e�;�` . � rt,�`' a .� -: a YI ri.t �S'�i<i�c rn-'�,/�(�/�y �y `+y�. ,�ty^s',t.�'"'�z,;;.:`'",.r,""a t't "t-c4..k rY:a,, .,f,Y' h �/ '�' S, L & r - .y w a.,t, o' '�- r,* 'S ,�'��"..�,.i K�-,a. �Cv� ,� „<-�... t � ' C�, t �� - 'i) r .S' .� t� „�k .�y i*�"�!,'" - I c'� % � { v �. 1 � a ���k#t � ,� •is z 'a v?�3„�' G � :.� _ - _-`'v,� :.� 'Y YtY'/.�i'<'t1/Y\''<\ \. 'S}'„"•�.'� : v.-1.{,Yr - �'�s'.- _ ,a+ -,^,rr Est a ria•; .�, > t .a� "� `;� �'`Y ,� } •, /'� � �r'i.. r ' �' j S �ti S :� ^s 4 t3� r r `w 1 ;..h <. _�y�;l,;.� yyt �S �i`� \ rt y/�`;i"<�"' . t" 'Y � � ��. �,/�,�•,� - i �t^ ; sv„',.v,•as^ :3 'aft z�� k .r`r ;' r qt� s �.� i T���%yy#.xr �i r'�"�x, `.....tk*•s� � an �,::au�+ `..:5' ,fS`- �}'^v '% icy 'v✓ ,t \/?. /`ahY r pool ✓�<✓r'\r>r YS :^'• � ' >,i�ti ',: >' Y ��Y"\J'�,rY' t, '„i,�. r�" ✓, , ^� ,�'>•. 3'r r'� sr -�v- z x � � .,�,?'�'r' r �6 �'a a'�s'vrs �;, r a to ' F t' ��>> ^• � ✓� � ca' �"Cv ��(``'y� �/� � "' � �' Jd � yt'c� z � «•3 � "'�,S ra, ae �'� �fi � �, " ,ay d s >rY 1 �: ^.Z`"'a. �/ ' �✓i �✓!''i \,., u•,.A*s J.. "4tilF:x.ry P:�.� F°;s'tsrE`r"i 's/.`•"`'�y".` ^l .ys*, 1,+'ra,P S /,.: '.sz"c1.'�;-'*es}w c.t s y ts^°`.tas z ".a#a°1•w"'.y ^r`tyr "•yM1>�Y�%S'S'S„> N t; IZ`�';( .Y�,C`.;I.� J .',,�.`., 'S. Y`• i` ,. S 7 •0. ~S' . C�,u <�r3"' �- �.�'. ...s..'. l„s -s ..�.. `�' ,,; .:��'� 't `tea N ,�,,,� 'x kr ',. �\vh.. S' ,, ✓, ',T>?Z/,� .7'i'S'`rZr Y 'j� , ?.�,�5,> '� e..r �?� r w:c � u:�`�"w,� � , � '� ,; F'`Z"'\ Y,•,.<:r�,`<+<,r,<;; ,, �"�- ;� r:r�§� t' �S�'1"�`'� � a°d�e Ss 4+,�azi a�'w� :74w,.�a 20 - I - ✓ '.;.0 r - - ,?'''_ Y � �r aC°�„�, t,+q � t. n �. �, t^+v �', , '✓}�. .a">r ¢.i � : � `� • "a. _ �, �`� `C .J. Y >-:r'';•J 2.�'rY\ :� --Y"t,:` 7' �. k�k �'"'� 3 �„ a � $,�,� �: k r '�> Cfi.'.%t.t'��'`� {<r1 vtii ,c ,>�,.; }3 4 :S",a C' m n:t�.'.`}S•,r' 'z�" r�.r' sz's5. "va's,:Y`a'u l'. \Y> Vic` r.,r1 db .r"c - a,n?`'X'#•',P ,„` r:iti, �\ . j �>•= r' .g,�a�ti �, 'xt,iw ���°`3'�4R,y r� ha rt�•'$.:• 'T '; �,_,�T+ r�' 6I-011 EXISTI JG ROOF i I TO F EMAIN I fi>�, > 4 ya4v 'ue zQ`tily"x�la` ✓4�}%' fy ,.. Z-^\; _,, a.4vt- ?'WX`ta.t r a3 "]STING FLAT RO �- v TO REMAIN s ✓ . p I L v,.i � >` Z,� '-,'.(,�^.. r k t,+ "'�' `�,,ti�''��°`�.s-.� ^47, t W I' m 0 'rn <> Z - .. 0 .. - j�'�,Z'ty<�a'�;rn �'�l/� - '4,t-§ �v ,x• � �� �x -'' �.»��F _... ,F.F,�b�'�, ra �' u; h 1,iD,�7r-'.�, .c „"`"i C. rx xs:'. g •� lnai a !2 "5;,ac➢ zgi'' �' Io Y � . ' co I " - - ✓ . 'y i ><_ �>:. - \vr t'"4 F'�I!Es r^�.$,�,, z• v+..;�*-k JrY R� +§xe'jk a i:: - - - - - �y.`< r - ✓�- v Il >' - Z- h Jy� 5"�,�xl. v,£r.#�":�"'� .a�.,.� _i �.; a , -bra. �.r��n,r�x x z ti S` y i I 2< 10 FEET TRIANGLE OF VISIBILITY I} rvN SHALL BE KEPT CLEAR OF VISUAL` 1 OBSTRUCTIONS BETWEEN A HEIGHT, , 7 x J�t,,ai rk i I rk OF 2.5 FEET TO 8 FEET ABOVE GRADE. ' - _ _ _ _ _ - :, L _ 1 :vim , '�>.`i / •C , �-'•. �¢�.� "? ,zr •�`` j•A r� t: gad �'�u r:. r�,�Tr tom,£ z�,� X MSX` ^�, ro a s _ N N - - - - - - _ ��r: (/>.'C: </�`4.C.>F 4`=�� /T O'CKI I L 2s#y v1� t ik i 1 tihf �4 ai - < : y Y _ ;< v� r':t ht�-cnPt,tx.,•zS.Aa xt ri$�T'.:"a' w,z+` 2 -r:"+` `;'.;","a"' ,.r?'-; - ¢ ¢ 1101_ 151-3" ♦x I T ?V ii'V'� ,< .'..' f'v '`ci• ry .Fy µ i. f a s t,,;.. 7 mc,. EXISTING DRAIN IELD S _ TO REMAIN _ 4 r �� '� �i.Y �} x > � � xo 9,,� Woox � �\ •`C,f'7 - `€ a xcz "'h rwxr �, "'t 251 OII N.. t � x�� a`.rk § � S � 'k � a +`?. t ,r 5 ^9"v �a• 4 rl � 4�'''r� a �" a —I . I - ',�, � r��` •i , a.� �. �.s � t q� ^"e si•� "'s�`� -twax' t� a � � '7s air �'>va'T-iz � '� € � �� �. S ATTACHED CERTI CATIONt BY SOUTHERN SEFITIC. 29'-10"�� I 101-011 .� •s ••� •� ••� •>_ •� ••>• ••— •� •� •� •>• •� •� •a ••>• •>• •a •� •r• �. •>• •r• •>. •� •� •� ••- 10TB•� •� ••- •� - bf?"k•€.`,� �t3-�Y-h.''"'' ,t>., 3 1'da.+.r%' t T 'SDE A K 110IJK 10'SIDESETBACK EXISTING SEPTIC TANK F� 1,050 GAL En � I I N TO REMAIN 1µ4f `r 1— I z' ag r IN � W I 0 IAt ar zT`)aa�wa"4rhk"w, � I Ii •� •� •� •>, •a •� •>, •� ••�P. •� ••— ••— •� •� •� •••• •� •� •� •� •>_. ••� •� •� •PR •iYi' iJW •� •� •� •� ••� •••• •>_ •� ••— ••s ••� •s zsy k > s "�, a:'sa x%x r . . a s �+ �t��^v°�saw� x.'i•s 'r�s�.� F� ,r �y' �F,��. r eu`,, a'":', `� EXISTING TO REMAINI�YA �P� 53�w*k�w-s�'�,, h�`aN`"�3.haa#r� ari�a�'� ��M..�, 9fp�y �'s.'uar�¢5 �+s ,<•:.s�i;st✓i. I: NO EXTERIOR WORK TO BE PERFOME PROPOSED SITE PLAN SCALE N.T.S. • SINGLE FAMILY RESIDENTIAL DISTRICT RS 3 SOUTH MIAMI LOT COVERAGE REQUIRED EXISTING PROPOSED MDC PROCESS 1 LOT SIZE 12, 548 SQF N/A 2 RESIDENTIAL DENSITY 2-5 Du /Acre 2-5 Du /Acre N/A 3 MAXIMUM BUILDING HEIGHT 25FT 12' -6" N/A 4 MAXIMUM HEIGHT -STORIES 2 1 N/A 5 AC BUILT AREA 2192 SQF 2616 SQF 6 NO AC BUILT AREA 423 SQF N/A 7 MINIMUM OPEN SPACE N/A A 8 MAXIMUM RESIDENTIAL UNITS ALLOWED 1 1 N/A MINIMUM SETBACKS (PRINCIPAL) REQUIRED EXISTING PROPOSED 1 PRIMARY FRONTAGE SETBACK 25 FT 25'--O" N/A . 3 SIDE SETBACK 10 FT 7'-7"/ 7'-8" N/A 4 REAR SETBACK 25 FT 30 -7" N/A mi i Dade County Department or Regulatory and Economic xesources Job copy 092 A- 01. pdf AREA ANALYSIS A/C NONA/C TOTAL Existing house 2.192 S.F. 423 S.F. 2.616 S. F Proposed addition 423 S.F. N/A 2.616 S.F. r F6:0WA rd StINFORMATION FOR DERMx �` 66£10 ...1tICttI, F L SS I 67t tiw ,ter; ,j m n, ...N ..rys u..' �•. �. � �£ 1� �,�" E JA�4�3f 5�;� P<i [[ .y ix. - , . . - v d„ .. k • � � � P _..� `+�.n +�� vu AA gym, z m r)i5 3�65 NX " w k „ r ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atellerint.com Hernan Santarcangelo, Architect NCARB AR# 96867 I` N � M (D U � U 0 _ of W U) W M z c� cn fUn v � ^ W`/ z c0 J �N Of CW V ZC7-2G� ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (c) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn: H.S. Designed by H.S. Checked by H.S. SCALE NOTED A-1 M Em *a' A- 0 2 . pdf -- v • 000 • •. • • • • .... • by H ERNAN NpA SANTARCq�yG�!'.�• SANTARCANGEL AR96867 V 0� Date:2021.07.23 FREE AEG �.F 11:43:05 -04 00 EXISTINGROOF PLAN L--------------------------------------------------------------------------------------------------------------- j ti Dade County Department of. Regulatory and'Economic.Resources - Job Copy SCALE 3/16":1'-0" 2 ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 p� C J :D N 0 b- r M O J ® V- Q J Q U � Cz r w cn o � W M z cD z � U C!� � o w o z r— c� Q w (D 2L-7-2C�J ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date: 8-JAN-21 Drawn H.S. Designed by H.S. Checked by H.S. SCALE: NOTED A-3 A-03.pdf y L' � �' �s„� GENERAL NOTES: - GENERAL CONTRACTOR SHALL HAVE A SUPERVISOR ON SITE WHILE ANY WORK IS BEING DONE. - THE DRAWINGS AND NOTES COMPLY, TO THE BEST OF OUR KNOWLEDGE WITH THE APPLICABLE MINIMUM BUILDING CODE. - PROVIDE AND MAINTAIN AT A CONVENIENT LOCATION WITHIN THE JOB SITE, A COMPLETE SET OF THE SIGNED AND SEALED PERMIT DOCUMENTS INCLUDING ALL THE LATEST SHOP DRAWINGS, ADDENDUMS, REVISIONS AND SUPPLEMENT SHEETS FOR REFERENCE AND COORDINATION FOR CONSTRUCTION. - THE ARCHITECT AND ENGINEER DO NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE HELD RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR OR ANY OTHER PERSONS PERFORMING WORK OR FAILURE OF ANY OF THEM TO CARRY OUT WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. EACH CONTRACTOR & SUBCONTRACTOR SHALL CARRY PUBLIC LIABILITY, PROPERTY DAMAGE AND WORKMAN's COMPENSATION INSURANCE AND SHALL PROVIDE OWNER WITH A VALID CERTIFICATE. - ALL WORK SHALL BE LIMITED TO THAT SHOWN ON THE PERMIT DOCUMENTS. NO ADDITIONAL WORK SHALL BE DONE WITHOUT PRIOR WRITTEN APPROVAL OF THE OWNER AND ARCHITECT. ANY ADDITIONAL WORK PERFORMED WITHOUT THIS CONSENT SHALL BE DONE AT THE CONTRACTOR'S; SOLE EXPENSE. 1N THE EVENT THAT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE DRAWINGS, THEN THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR NOTED. - THE CONTRACTOR SHALL SUBMIT A COMPLETE CONSTRUCTION SCHEDULE TO THE OWNER, WHICH COORDINATES ALL WORK WITH SUPPLIERS; SUB -CONTRACTORS AND SPECIALTY CONTRACTORS WITH THE FINAL BID. - ALL WORK SHALL COMPLY WITH THE PROVISIONS OF THE LOCAL BUILDING CODE AND ALL APPLICABLE ORDINANCES AND PROVISIONS. - ALL CONTRACTORS SHALL PROTECT'THE WORK OF OTHER TRADES. ANY & ALL CONFLICTS BETWEEN TRADES ARE TO BE COORDINATED BY THOSE TRADES AND NOTIFICATION OF SUCH CONFLICTS MADE TO THE ARCHITECT AND THE OWNER. ANY DAMAGED WORK SHALL BE REPLACED BY THE CONTRACTOR CAUSING SAID DAMAGE(S) AT HIS EXPENSE. - THE CONTRACTOR SHALL EXAMINE ALL AREAS IN WHICH WORK IS TO BE CONSTRUCTED AND SHALL REPORT ANY SUCH WORK WHICH IS NOT IN SUITABLE CONDITION TO RECEIVE WORK UNDER THIS CONTRACT. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE CONDITION OF THE FINISHED WORK AFTER THE WORK UNDER THIS CONTRACT IS STARTED. - THE CONTRACTOR SHALL VISIT THE JOB SITE AND SHALL VERIFY ARCHITECT'S DIMENSIONS AND DETAILS PRIOR TO INITIAL BID SUBMITTAL. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY ERRORS, OMISSIONS, DISCREPANCIES AND/OR CONFLICTS IN CONSTRUCTION DOCUMENTS, BEFORE BID SUBMITTAL; WHICH WOULD INTERFERE COMPLETION OF THIS WORK OR WHICH WOULD AFFECT THE BID PRICE. ALL DISCREPANCIES NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT/OWNER PRIOR TO FINAL BID SUBMITTAL SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO OWNER. ALL PLAN DIMENSIONS TAKE PRECEDENCE OVER THE SCALING OF THE PLANS. THE DIMENSIONS ARE CALCULATED AND ANNOTATED BY COMPUTER AND ROUNDED TO THE NEAREST INCH. LOCATING PARTITIONS TO CENTERLINE OF MULLIONS (WHERE APPLICABLE) SHALL TAKE PRECEDENCE OVER GIVEN DIMENSIONS. DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT WOULD REDUCE THEIR LOAD -CARRYING CAPACITY OR LOAD -DEFLECTION RATIO. - OBTAIN APPROVAL FROM OWNER BEFORE CUTTING AND PATCHING THE FOLLOWING OPERATING BUILDING ELEMENTS OR SAFETY RELATED SYSTEMS: PRIMARY OPERATIONAL SYSTEMS AND EQUIPMENT, AIR OR SMOKE BARRIERS, FIRE PROTECTION SYSTEMS, CONTROL SYSTEMS, COMMUNICATION SYSTEMS, AND ELECTRICAL WIRING SYSTEMS. - THE GENERAL CONTRACTOR SUB -CONTRACTORS AND ALL VENDORS ARE TO VERIFY ALL CLEARANCESR A R ELEVATORS, T REQUIRED (CORRIDORS, STAIRS, S, ELE O S, .) E CQ FOR DELIVERIES, PASSAGE OF ALL JOB MATERIALS OR EQUIPMENT. THE OWNER'S PROJECT MANAGER SHALL BE INFORMED OF ANY POTENTIAL OR ACTUAL PROBLEMS WHICH IN ANY WAY MIGHT AFFECT WORK SCHEDULING, ANY VENDORS SUBCONTRACTORS ETC. INCLUDINGAFTER HOURS DELIVERIES S IMPOSED BY LANDLORD. - ALL WORK IS TO CONFORM TO PERMIT AND DRAWINGS SPECIFICATIONS. ANY CONDITIONS IN THE FIELD AFFECTING THE DESIGN CONCEPT ARE T BE I G S C O BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BID SUBMITTAL. - - THE CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS THE CONTRACTOR SHALL IN ADDITION PAY ALL LAWFUL AND PERMIT FEES FOR THE PLUMBING AND ELECTRICAL WORK. - THE CONTRACTOR SHALL SECURE ALL CERTIFICATES OF INSPECTION AND OF OCCUPANCY THAT MAY BE REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER THE WORK. CONTRACTOR SHALL SCHEDULE AND COORDINATE ALL WORK WITH SUPPLIERS, SUBCONTRACTORS AND SPECIALTY CONTRACTORS TO EXPEDITE THE PURCHASE OF "LONG LEAD" MANUFACTURED ITEMS TO ASSURE PROMPT DELIVERY AND INSTALLATION. - THE CONTRACTOR SHALL PURCHASE; COORDINATE & INSTALL ALL APPLIANCES AND EQUIPMENT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PERMIT DRAWINGS. SPECIFICATIONS AND INSTALLATIONS METHODS PROVIDED BY MANUFACTURE SHALL BE STRICTLY FOLLOWED AND ARE HEREWITH MADE A PART OF THESE DOCUMENTS, - CONTRACTOR SHALL COORDINATE, ALL OWNER FURNISHED AND INSTALLED ITEMS. VERIFY ITEMS PRIOR TO BID SUBMITTAL. - PROVIDE ALL NECESSARY ELECTRICAL OR MECHANICAL EQUIPMENT MAINTENANCE AND INSTRUCTION MANUALS TO THE OWNER FOR REVIEW. - CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR ARRANGING ELEVATORS OR OTHER HOISTING FACILITIES FOR HANDLING MATERIALS. - ALL BUILDING RESTROOMS ARE NOT TO BE USED BY CONSTRUCTION PERSONNEL. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE FOR SUCH SERVICES IN THE GENERAL CONDITIONS OF THEIR BID. - ALL WORKMAN WILL USE DESIGNATED ENTRANCE DOORS FOR ENTERING OR LEAVING THE BUILDING. ALL MATERIALS AND/OR DELIVERIES SHALL BE THROUGH THESE ENTRANCES. SPECIAL PERMISSION, BY THE OWNER, SHALL BE REQUIRED TO USE ANY OTHER ENTRANCES. - ALL WOOD IN CONTACT W/ MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. - ALL SPECIFIED MATERIALS SHALL BE NEW OF QUALITY SPECIFIED AND DELIVERED IN AMPLE QUANTITY TO THE JOB SITE TO PREVENT DELAY OF WORK. - CONTRACTOR SHALL PATCH & REPAIR ALL WALLS & COLUMN WHERE DEMOLITION HAS DAMAGED. - GYPSUM WALLBOARD (GWB) JOINTS SHALL BE TAPED/SPACKLED LEVEL AND PROPERLY PREPARED TO RECEIVE SPECIFIED FINISH MATERIALS. EXTERIOR CORNERS SHALL RECEIVE METAL CORNER REINFORCING BEADS AND BE SPACKLED IN CONVENTIONAL METHOD. NO HORIZONTAL GWB JOINTS SHALL BE ACCEPTED UNLESS APPROVED BY THE LANDLORD\ OWNER. BUTTED, UNTAPERED GWB JOINTS OR BULGING AND UNEVEN FINISHED GWB WILL NOT BE ACCEPTED. FULL HEIGHT GWB SHEETS SHALL BE USED THROUGHOUT FOR FULL HEIGHT CONSTRUCTION. - WATERPROOF BOARD SHALL BE PROVIDED IN RESTROOM AREAS AND SINK AREAS. ALL EXISTING GWB SHALL BE CAREFULLY EXAMINED TO ASSURE THEIR INSTALLATION SATISFIES THE ABOVE REQUIREMENTS. REMEDIAL -WORK, NECESSARY TO UPGRADE SAID SURFACES SHALL BE INCLUDED IN BID PRICE. ALL CHANGE ORDERS SHALL BE IN WRITING AND SHALL BE SIGNED BY OWNER AND ARCHITECT. - NOISE SHALL BE KEPT TO A MINIMUM. ALL SHOOTING OF HILTY GUNS OR SIMILAR NOISE PRODUCING MACHINERY THAT MAY DISTURB GUESTS SHALL BE DURING TIMES AS SPECIFIED BY THE OWNER. - NO STRUCTURAL MEMBER SHALL BE NOTCHED, CUT, ALTERED OR MOVED IN ANY WAY WITHOUT > PREVIOUS WRITTEN AUTHORIZATION FROM ARCHITECT OR STRUCTURAL ENGINEER. THERE SHALL BE NO PENETRATIONS IN PRE -STRESSED - BEAMS OR JOISTS AND NO DRILLING OR SHOOTING HANGERS OR PINS IN PRE -STRESSED BEAMS OR PRE -CAST JOISTS. - THE CONTRACTOR SHALL AT ALL TIMES PROVIDE PROTECTION AGAINST THE WEATHER AS TO MAINTAIN THE WORK, MATERIALS, APPARATUS AND FIXTURES FREE FROM INJURY OR DAMAGE. ANY WORK DAMAGED BY FAILURE OF THE CONTRACTOR TO PROVIDE PROTECTION SHALL BE REMOVED AND REPLACED . WITH NEW WORK AT CONTRACTORS EXPENSE. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION THE GENERAL CONTRACTOR IS TO PROVIDE THE OWNER WITH A CONSTRUCTION SCHEDULE AND A COPY OF THE PERMIT. - THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL ELEMENTS WHICH HAVE NOT BEEN DESIGNED OR ENGINEERED IN THESE DRAWINGS. - 'PRIOR TO SUBMITTING A SHOP DRAWING TO THE PROPERTY OR PROJECT OWNER, CONTRACTOR SHALL: REVIEW EACH SUCH SUBMISSION FOR CONFORMANCE WITH THE MEANS, METHODS,`. TECHNIQUES, SEQUENCES, AND OPERATIONS OF CONSTRUCTION, AND SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO, ALL OF WHICH ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR; APPROVE EACH SUCH SUBMISSION BEFOR SUBMITTING IT; AND SO STAMP EACH SUCH SUBMISSION BEFORE SUBMITTING IT. DESIGN PROFESSIONAL SHALL ASSUME THAT NO SHOP DRAWING OR RELATED SUBMITTAL COMPRISES A VARIATION UNLESS CONTRACTOR ADVISES DESIGN PROFESSIONAL OTHERWISE VIA A WRITTEN INSTRUMENT WHICH. IS ACKNOWLEDGED BY DESIGN PROFESSIONAL IN WRITING. THE SHOP DRAWINGS AND RELATED MATERIAL (IF ANY) CALLED FOR ARE INDICATED BELOW. IN THE EVENT THAT DESIGN PROFESSIONAL WILL REQUIRE MORE THAN TEN (10) WORKING DAYS TO PERFORM REVIEW, DESIGN PROFESSIONAL SHALL SO NOTIFY CONTRACTOR. - THE CONTRACTOR SHALL INCLUDE ALL TEMPORARY UTILITIES (IF APPLICABLE) INCLUDING ELECTRICITY, WATER AND TELEPHONE IN HIS BIDS. THE GENERAL CONTRACTOR AND ANY INDEPENDENT SUBCONTRACTORS HIRED BY THEM SHALL EXERCISE DUE CARE AND SKILL IN PERFORMING ALL WORK WITH REGARDS TO THIS PROJECT. - THE CONTRACTOR SHALL AND DOES HEREBY WARRANT AND/OR GUARANTY THAT ALL MOVEABLE OR ADJUSTABLE WORK SHALL REMAIN IN PERFECT WORKING ORDER, INCLUDING HARDWARE, WEATHER STRIPPING, DOORS, WINDOWS, DRAWERS, APPARATUS, MACHINERY, ELECTRICAL EQUIPMENT, AND ALL OTHER EQUIPMENT TO WHICH THIS HEADING IS APPLICABLE, FOR A PERIOD OF ONE YEAR FROM DATE OF COMPLETION AS EVIDENCED BY THE DATE OF FINAL ACCEPTANCE OF THIS WORK. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RE -DOING ANY WORK THAT FAILS TO CONFORM TO THE DRAWINGS AND DETAILS AS SHOWN IN THESE CONSTRUCTION DOCUMENTS;AND CORRECT ANY DEFECTS DUE TO FAULTY MATERIALS AND WORKMANSHIP WHICH APPEAR WITHIN ONE YEAR FROM DATE OF MOVE -IN. THESE PROVISIONS APPLY, ALSO, TO WORK DONE BY DIRECT EMPLOYEES OF THE CONTRACTOR, SUB -CONTRACTORS OR VENDERS. NOTHING IN THE ABOVE INTENDS OR IMPLIES` THAT THIS GUARANTY SHALL APPLY TO WORK WHICH HAS BEEN ABUSED OR NEG.L.ECTED BY THE OWNER OR HIS SUCCESSOR IN INTEREST: ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER AND 1N ACCORDANCE WITH ALL GOVERNING BODIES, RULES, AND REGULATIONS. REMOVE RUBBISH AND DEBRIS DAILY, LEAVE JOB CLEAN UPON COMPLETION OF WORK, INCLUDING CLEANING OF HARDWARE, FIXTURES, AND G.L.ASS, AND REMOVING OF STAINS, DUST, DIRT, AND PAINT, AND POLISHING OF ALL FINISHED FLOORS AND CABINETRY. FINISH NOTES: - FINISH WORK SHALL BE SMOOTH, FREE FROM ABRASION, TOOL MARKS, RAISED GRAIN, ETC. ON EXPOSED SURFACE. - ALL FASTENINGS AND ATTACHMENTS SHALL BE FULLY CONCEALED FROM VIEW. - USE MATERIALS THAT ARE IDENTICAL TO EXISTING MATERIALS. IF IDENTICAL MATERIALS ARE ' NOT AVAILABLE OR CANNOT BE USED WHERE EXPOSED SURFACES ARE INVOLVED, USE MATERIALS THAT MATCH EXISTING ADJACENT SURFACES TO THE FULLEST EXTENT POSSIBLE WITH REGARD TO VISUAL EFFECT. USE MATERIAL WHOSE INSTALLED PERFORMANCE WILL EQUAL OR SURPASS THAT OF EXISTING MATERIALS. - PRIOR TO ORDERING FINISH MATERIALS CONTRACTOR SHALL SUBMIT CURRENT PRODUCTION 6" X 6" MINIMUM SAMPLE OF EACH FINISH MATERIAL, AND A SAMPLE FOR EACH COLOR OR FINISH, SPECIFIED, INCLUDING BUT NOT LIMITED TO PAINT (12" X 12"), WALL COVERING, CARPET, MARBLE, TILE, VCT, ETC., TO DESIGNER/ OWNER FOR APPROVAL. - ALL FABRICS SPECIFIED FOR WALL COVERINGS APPLICATION SHALL RECEIVE DOUBLE LAYER FACTORY APPLIED ACRYLIC BACKING. GWB DESIGNATED TO RECEIVE WALL COVERINGS SHOULD BE PREPPED WITH ONE COAT OF ULTRA -HIDE PVA PRIMER SEALER; COLOR TO BLEND WALL COVERING COLOR. - PREPARE NEW AND EXISTING WALLS TO RECEIVE PAINT OR WALL L COVERING INCLUDING AREAS BEHIND ELECTRICAL AND THERMOSTAT RECEPTACLE. - ALL SURFACES DESIGNATED TO BE PAINTED SHALL BE PERFECTLY DRY AND SMOOTH BEFORE APPLICATIONS OF COVERINGS. WALL MARKINGS MUST BE SUFFICIENTLY SEALED BEFORE APPLICATION OF FINISH MATERIAL SO AS TO PREVENT BLEED -THROUGH. PAINTED SURFACES SHALL RECEIVE ONE PRIMER COAT, TINTED TO BE ONE SHADE OFF THE COLOR OF THE FINISH COAT AND SUFFICIENT FINISH COATS TO PROPERLY COVER SURFACE. PRIME ALL SURFACES ACCO RDING TO MANUFACTURER'S SPECIFICATIONS PRIOR TO APPLICATION OF PAINT. WHERE PATCHING OCCURS IN A SMOOTH PAINTED SURFACE, EXTEND FINAL PAINT COAT OVER ENTIRE UNBROKEN SURFACE- CONTAINING THE PATCH, AFTER THE PATCHED AREA HAS RECEIVED PRIMER AND SECOND COAT. WHERE REMOVAL OF WALLS OR PARTITIONS EXTENDS ONE FINISHED AREA INTO ANOTHER PATC H AND REPAIR FLOOR AND WALL SURFACES 1N THE NEW SPACE TO PROVIDE AN EVEN SURFACE OF UNIFORM COLOR AND APPEARANCE. REMOVE EXISTING FLOOR AND WALL COVERINGS AND REPLACE WITH NEW MATERIALS, IF NECESSARY TO ACHIEVE UNIFORM COLOR AND APPEARANCE. = PROPERLY PREPARE SURFACES ACCORDING TO MANUFACTURER'S RECOMMENDED APPLICATION OF SPECIFIED FINISHES AND IN ACCORDANCE WITH BEST TRADE PRACTICE. FLOORS SHALL BE INSPECTED FOR DAMAGE, WARPAGE OR OTHER NOTICEABLE DEVIATIONS, PATCHED AND LEVELED. FLOORS SHALL BE SMOOTH AND CLEAN PRIOR TO INSTALLATION OF NEW FLOOR FINISHES. - IF IN GC SCOPE, ALL CONTIGUOUS CARPET, WALL COVERING AND FABRICS OF THE SAME SPECIFICATION MUST BE FROM ONE DYE LOT AND MUST MEET INDUSTRY STANDARD TOLERANCE FOR SIDE TO SIDE MATCH. - ALL HARDWARE SHALL BE OF THE SAME MANUFACTURER TO MAINTAIN CONTINUITY OF FINISH AND STYLE AND TO SIMPLIFY MAINTENANCE AND REPLACEMENT. DEMOLITION NOTES: - THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AFFECTING THE PRELIMINARY DEMOLITION; WHETHER SHOWN OR NOT SHOWN, ITEMS MAY HAVE TO BE RELOCATED AND/OR TEMPORARILY SUSPENDED, SUPPORTED, OR REMOVED AS REQUIRED FOR PURPOSES OF DESIGN DISCOVERY. - GENERAL CONTRACTOR SHALL COORDINATE PRELIMINARY DEMOLITION OPERATIONS WITH ALL OTHER REQUIRED SUB -CONTRACTORS AND RESPECTIVE TRADES WHERE APPLICABLE. ALL DEMOLITION WORK SHALL BE CONDUCTED UNDER CONTROLLED CONDITIONS. COORDINATE ANY SHUTDOWN OF EXISTING SERVICES AND EQUIPMENT REMAINING IN USE WITH OWNERS' REPRESENTATIVE. PROVIDE ADEQUATE NOTICE AND MAKE PROVISIONS TO MINIMIZE IMPACT TO ANY NEIGHBORING UNITS OR TENANTS. - DISPOSE OF ALL MATERIALS OFF SITE, ALL MATERIALS SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL FEDERAL STATE AND LOCAL REGULATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE REMOVAL AND DISCARDING OF ALL DEMOLITION WASTEINCLUDING ANY UNFORESEEN ITEMS WITHIN THE SCOPE OF THE PROJECT. ALL CONSTRUCTION, DEMOLITION & RENOVATION ACTIVITIES TO COMPLY WITH NFPA 241. - EXIST ACCESS AND EXITS ARE TO REMAIN CLEAR AND UNOBSTRUCTED. . - TRASH AND DEBRIS TO BE REMOVED DAILY. 1 MILLWORK NOTES: . - MILLWORKER TO PROVIDE COORDINATED SHOP DRAWINGS WITH ALL EQUIPMENT FOR ALL MILLWORK ITEMS TO ARCHITECT AND INTERIOR DESIGNER FOR REVIEW AND APPROVAL, PRIOR TO. FINAL PRODUCTION. GC TO PROVIDE COORDINATED .SHOP DRAWINGS AS REQUIRED. - MILLWORKER TO PROVIDE FINISH SAMPLES OF ALL MATERIALS TO ARCHITECT AND INTERIOR DESIGNER FOR FINAL APPROVAL PRIOR TO RRODUCTION.. PROVIDE FULL FINISHED MOCK UP OF ALL WOOD PANELING AS ILLUSTRATED IN DRAWINGS FOR REVIEW AND APPROVAL BY OWNER AND INTERIOR .DESIGNER PRIOR TO FINAL PRODUCTION. - MILLWORKER TO PROVIDE PROGRESS AND FINAL PRODUCTION PHOTOS TO INTERIOR DESIGNER FOR FINAL APPROVAL. - EQUIPMENT AND PLUMBING FIXTURES SHOWN FOR REFERENCE ONLY. GC AND MILLWORKER TO CONFIRM WITH PLUMBING FIXTURES AND EQUIPMENT CUT SHEETS. IN ORDER TO COORDINATE FINAL OPENING SIZES WHERE APPLICABLE. - ALL WOOD OR STONE EDGES TO BE EASED OFF BY 1/8" RADIUS. - ALL HARDWARE PENDING OWNER APPROVAL. - ALL WOOD TO BE KILN DRIED TO 5-9% MOISTURE CONTENT. - ALL PLYWOOD SUBSTRATES TO BE MARINE GRADE. - PROVIDE MARINE GRADE CONSTRUCTION FOR USE IN HIGH HUMIDITY LOCATION. ALL ITEMS TO BE SUITABLE FOR USE IN HIGH -HUMIDITY, OCEAN SIDE USE. - ALL EXPOSED WELDS TO BE GROUND SMOOTH. NO VISIBLE WELDS. - ALL STONE SURFACES TO HAVE MITERED CORNERS WITH EASED EDGES. . - ALL EXPOSED SURFACES SHALL BE FREE FROM DENTS, TOOL MARKS, WARPING, BUCKLING AND OPEN JOINTS. SURFACES EXPOSED TO VIEW SHOULD NOT BE STAMPED ON, PRINTED ON, OR MARKED WITH IDENTIFICATION LABELS. - HARDWOOD SHALL BE MARINE GRADE AND 1 ST QUALITY. - ALL MATERIALS USED IN THE FINISHING OF FURNITURE SHALL BE OF THE HIGHEST QUALITY STANDARD. EACH STEP OF THE WORK SHALL BE THOROUGHLY SANDED, SMOOTHED AND CLEANED BEFORE ANY FINISH IS APPLIED. ALL EXPOSED MEMBERS WILL BE MADE TO CONFORM AS SPECIFIED IN COLOR AND FINISH. - FINISHES MUST BE CONSISTENT AND SMOOTH WITH NO ROUGH EDGES. INTERIOR EXTERIOR SIDES, EDGES AND CAVITIES ARE TO BE FULLY FINISHED UNLESS SPECIFIED OTHERWISE. - FINISHING SHALL BE PERFORMED BASED. ON. THE AMERICAN WOODWORKING INSTITUTE'S (AWI) FINISH SYSTEM STANDARDS FOR A "PREMIUM GRADE FINISH. ALL WOOD FURNITURE SHOULD BE FINISHED WITH A MOISTURE PROOF FINISH TO WITHSTAND ALCOHOL AND FRUIT ACIDS WITH A COMMERCIAL GRADE POLYURETHANE OR PRE -CATALYZED LACQUER OR BETTER FINISH (MIN. THICKNESS 3.0 ML.) MILLWORKER SHALL SUPPLY ALL INTERIOR AND DECORATIVE HARDWARE AND OTHER PARTS REQUIRED FOR PROPER AND SECURE INSTALLATION OF FURNITURE AND HARDWARE. DECORATIVE HARDWARE SHALL BE SUPPLIED AS SPECIFIED. JOINTS WILL BE MORTISE AND TENON, TONGUE AND GROOVED, SPLINED OR DOUBLE DOWELED. - JOINTS SHALL BE FULL LENGTH BLOCKED, G.L.UED, AND SCREWED IN TWO DIRECTIONS, FOLLOWING THE BEST PRACTICE OF CONSTRUCTION. ALL PULLS MUST HAVE TWO SCREW -POINTS TO PREVENT'TURNING." - ALL EXPOSED METAL TO BE -OF A GAUGE APPROPRIATE TO PIECE AND FOR HOSPITALITY USE, ALONG WITH NO VISIBLE WELDED JOINTS. - MILLWORKER WILL PROVIDE WOOD SLAT FINISH FOR DOORS AS INDICATED IN PLAN. GC TO PROVIDE SPECIFIED HARDWARE ACCORDING.L.Y. - MILLWORKER TO PROVIDE HEAVY-DUTY, ADJUSTABLE NYLON CARPET G.L.IDES ON FEET AS REQUIRED. - STONE TOPS SHALL HAVE PLYWOOD SUB -TOP, PAINTED OR STAINED AS APPROPRIATE. TOP SHALL BE G.L.UED AND SCREWED TO BASE OF CASEGOOD. CP°FDigital lsi ned �o'•.- CO.***.• . I by HERNAN :���NPN-SANTARCgN,9, •. • SANTARCANGEL • * O. 11AR96867 � 01 • ••V 's ••• . ••••�'�� ate: Q21.07.23 • •G` - U RED A'� 11.46.22 _ 04, 00 k-or I I I I I I I I I I I . I I 1 I I I I I. I I I I I I I I I I I I I I I . I I I I I I I 1. I I I. I .I I I I I I I I SWIMMING POOL NOTES (FBC 2017-Residential, 6th Edition) R4501.17.1 OUTDOOR SWIMMING POOLS. OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER COMPLYING WITH R4501.17.1.1 THROUGH R4501.17..1.14. R4501.17.1.1 THE TOP OF THE BARRIER SHALL BE AT LEAST 48 INCHES (1219 MM) ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL: THE MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM OF THE BARRIER SHALL BE 2 INCHES (51 MM) MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. WHERE THE TOP OF THE POOL STRUCTURE IS ABOVE GRADE THE BARRIER MAY BE AT GROUND LEVEL OR MOUNTED ON TOP OF THE POOL STRUCTURE. WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE, THE MAXIMUM VERTICAL CLEARANCE BETWEEN THE TOP OF THE POOL STRUCTURE AND THE BOTTOM OF THE BARRIER SHALL BE 4 INCHES (102 MM). R4501.17.1.2 THE BARRIER MAY NOT HAVE ANY GAPS, OPENINGS, INDENTATIONS, PROTRUSIONS, OR STRUCTURAL COMPONENTS THAT COULD ALLOW A YOUNG CHILD TO CRAWL UNDER, SQUEEZE THROUGH, OR CLIMB OVER THE BARRIER AS HEREIN DESCRIBED BELOW. ONE END OF A REMOVABLE CHILD BARRIER SHALL NOT BE REMOVABLE WITHOUT THE AID OF TOOLS. OPENINGS IN ANY BARRIER SHALL NOT ALLOW PASSAGE OF A 4-INCHDIAMETER (102 MM) SPHERE. R4501.17.1.3 SOLID BARRIERS WHICH DO NOT HAVE OPENINGS SHALL NOT CONTAIN INDENTATIONS OR PROTRUSIONS EXCEPT FOR NORMAL CONSTRUCTION TOLERANCES AND TOOLED MASONRY JOINTS. R4501.17.1.4 WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES (1143 MM), THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 11NCHES (44 MM) IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1 % INCHES (44 MM) IN WIDTH. R4501.17.1.5 WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS 45 INCHES (1143MM) OR MORE, SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 4 INCHES (102 MM). WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1 %INCHES (44 MM) IN WIDTH. R4501.17.1.6 MAXIMUM MESH SIZE FOR WOOD FENCES SHALL BE A 2'/< INCH SQUARE (57 MM) UNLESS THE FENCE IS PROVIDED WITH SLATS FASTENED AT THE TOP OR BOTTOM WHICH REDUCE THE OPENINGS TO NO MORE THAN 1 s/.INCHES (44 MM). R4501.17.1.7 WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS, THE MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS SHALL BE NO MORE THAN 1 % INCHES (44 MM). R4501.17.1.8 ACCESS GATES, WHEN PROVIDED, SHALL BE SELF -CLOSING AND SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED WITH A SELF -LATCHING LOCKING DEVICE LOCATED ON THE POOL SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING GREATER THAN 1/2 'INCH (12.7 MM) WITHIN 18 INCHES (457 MM) OF THE RELEASE MECHANISM. R4 .17.1.9 WHERE A WALL OF A DWELLING SERVES AS PART OF THE BARRIER ONE OF 501 , THE FOLLOWING SHALL APPLY: 1. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL SHALL BEEQUIPPED WITH AN EXIT.ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85 DBA AT 10 FEET 3048 MM). ANY ACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. SEPARATE ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF EN R WIRED T A CENTRAL ALARM SOUND WHEN CONTACT IS BROKEN AT ANY S SOS O OPENING. EXCEPTIONS: A. SCREENED R PROTECTED WINDOWS HAVING A BOTTOM SILL HEIGHT OF 48 SCRE O O S G H R MEASURED FROM THE INTERIOR FINISHED FLOG AT THE INCHES (1219 MM) OR MORE SU ED RO R POOL ACCESS LEVEL. B. WINDOWS FACING THE POOL ON FLOOR ABOVE THE FIRST STORY. C. SCREENED ORPROTECTED PASS -THROUGH KITCHEN WINDOWS 42 INCHES 1067 MM OR HIGHER WITH A COUNTER BENEATH. 2. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH A SELF -CLOSING, SELF -LATCHING DEVICE WITH POSITIVE MECHANICAL LATCHING/LOCKING INSTALLED A MINIMUM OF 54 INCHES (1372 MM) ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 3. A SWIMMING POOL ALARM THAT, WHEN PLACED IN A POOL, SOUNDS AN ALARM UPON DETECTION OF AN ACCIDENTAL OR UNAUTHORIZED ENTRANCE INTO THE WATER. SUCH POOL ALARM MUST MEET AND BE INDEPENDENTLY CERTIFIED TO ASTM STANDARD F2208, TITLED "STANDARD SAFETY SPECIFICATION FOR RESIDENTIAL POOL ALARMS," WHICH INCLUDES SURFACE MOTION, PRESSURE, SONAR, LASER, AND INFRARED ALARMS. FOR PURPOSES OF THIS PARAGRAPH, THE TERM "SWIMMING POOL ALARM" DOES NOT INCLUDE ANY SWIMMING PROTECTION ALARM DEVICE DESIGNED FOR INDIVIDUAL USE, SUCH AS AN ALARM ATTACHED TO A CHILD THAT SOUNDS WHEN THE CHILD EXCEEDS A CERTAIN DISTANCE OR BECOMES SUBMERGED IN WATER. R4501.17.1.10 WHERE AN ABOVEGROUND POOL STRUCTURE IS USED AS A BARRIER OR WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE, AND THE MEANS OF ACCESS IS A LADDER OR STEPS, THE LADDER OR STEPS EITHER SHALL BE CAPABLE OF BEING SECURED, LOCKED OR REMOVED TO PREVENT ACCESS, OR THE LADDER OR STEPS SHALL BE SURROUNDED BY A BARRIER WHICH MEETS THE REQUIREMENTS OF SECTIONS R4501.17.1.1 THROUGH R4501.17,1.9 AND SECTIONS R4501.17.1.12 THROUGH R4501.17.1.14. WHEN THE LADDER OR STEPS ARE SECURED, LOCKED OR REMOVED; ANY OPENING CREATED SHALL NOT ALLOW THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE. R4501.17.1.11 STANDARD SCREEN ENCLOSURES WHICH MEET THE REQUIREMENTS OF SECTION R4501.17 MAY BE UTILIZED AS PART OF OR ALL OF THE "BARRIER" AND SHALL BE CONSIDERED A "NONDWELLING" WALL. REMOVABLE CHILD BARRIERS SHALL HAVE ONE END OF THE BARRIER NONREMOVABLE WITHOUT THE AID OF TOOLS. R4501.17.1.12 THE BARRIER MUST BE PLACED AROUND THE PERIMETER OF THE POOL AND MUST BE SEPARATE FROM ANY FENCE, WALL, OR OTHER ENCLOSURE SURROUNDING THE YARD UNLESS THE FENCE, WALL, OR OTHER ENCLOSURE OR PORTION THEREOF IS SITUATED ON THE PERIMETER OF THE POOL, IS BEING USED AS PART OF THE BARRIER, AND MEETS THE BARRIER REQUIREMENTS OF THIS SECTION. R4501.17.1.13 REMOVABLE CHILD BARRIERS MUST BE PLACED SUFFICIENTLY AWAY FROM THE WATER'S EDGE TO PREVENT A YOUNG CHILD OR MEDICALLY FRAIL ELDERLY PERSON WHO MAY MANAGE TO PENETRATE THE BARRIER FROM IMMEDIATELY FALLING INTO THE WATER. SUFFICIENTLY AWAY FROM THE WATER'S EDGE SHALL MEAN NO LESS THAN 20 INCHES (508 MM) FROM THE BARRIER TO THE WATER'S EDGE DWELLING OR NONDWELLING WALLS INCLUDING SCREEN ENCLOSURES WHEN USED AS PART OR ALL OF THE "BARRIER" AND MEETING THE OTHER BARRIER REQUIREMENTS, MAY BE AS CLOSE TO THE WATER'S EDGE AS PERMITTED BY THIS CODE. I I R4501.17.1.14 A WALL OF A DWELLING MAY SERVE AS PART OF THE BARRIER IF IT DOES I NOT CONTAIN ANY DOOR OR WINDOW THAT OPENS TO PROVIDE DIRECT ACCESS FROM I THE HOME TO THE SWIMMING POOL. I . I I R308 GLAZING (FBC 2017-Residential, 6th Edition) I GLAZING SHALL COMPLY WITH TABLE R308.1(1) I FBC-R308.3.1 GLAZING IN BOORS OR ENCLOSURES FOR HUT TUBS, WHIRLPOOLS, 1 SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS SHALL BE TESTED IN ACCORDANCE I WITH CPSC 16 CFR 1201 AND SHALL BE CLASSIFIED AS CATEGORY 11 AS INDICATED IN �[ORIIJA BUILDING CODE NOTES (� nn1'c�I 'j'� CC�c+ Mi i D�d�IC�ti�d.�II�De��in&,u�t7 of Regulatory.. and Economic Resources - Job_ .Copy 092 A-05.pdf • • • • • • • FIRE-RESISTANT NOTES (FBC 2017-RESIDENTIAL, 6TH EDITION) • R302.5 DWELLING -GARAGE OPENING AND PENETRATION PROTECTION. . • • • • • • • • • OPENINGS AND PENETRATIONS THROUGH THE WALLS OR CEILINGS SEPAAAfINd:.HE DWELLING FROM THE GARAGE SHALL BE IN ACCORDANCE WITH SECTION R•3.02.5.1 THROUGH R302.5.3. R302.5.1 OPENING PROTECTION. :000: " • • OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES (35 MM) IN THICKNESS, SOLID OR HONEY COMB CORE STEEL DOORS NOT LESS THAN 1 3/8 INCHES (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. R302.5.2 DUCT PENETRATION. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH (25.4 MM) MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE OPENINGS INTO THE GARAGE. R302.5.3 OTHER PENETRATIONS. PENETRATIONS THROUGH THE SEPARATION REQUIRED IN SECTION R302.6 SHALL BE PROTECTED AS REQUIRED BY SECTION R302.11, ITEM 4. FLAME SPREAD AND SMOKE -DEVELOPED INDEX (FBC 2017-RESIDENTIAL, 6TH EDITION) R302.9 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR WALL AND CEILING FINISHES. FLAME SPREAD AND SMOKE DEVELOPED INDEXES FOR WALL AND CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTIONS R302.9.1 THROUGH R302.9.4. R302.9.1 FLAME SPREAD INDEX. WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX OF NOT GREATER THAN 200. R302.9.2 SMOKE -DEVELOPED INDEX. WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. R302.10 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR INSULATION. FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN ACCORDANCE WITH SECTIONS R302.10.1 THROUGH R302.10.5. R302.10.1 INSULATION. INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS AND VAPOR -PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHERE TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723. R302.10.2 LOOSE -FILL INSULATION. LOOSE -FILL INSULATION MATERIALS THAT CANNOT BE MOUNTED IN THE ASTM E84 OR UL 72 APPARATUS A SCREEN R ARTIFICIAL SUPPORTS SHALL COMPLY WITH THE 3 US WITHOUT SC E O FLAME SPREAD AND SMOKE -DEVELOPED LIMITS OF SECTION R302,10,1 WHERE TESTED IN ACCORDANCE WITH CAN/ULC S102.2. R302.10.3 CELLULOSIC FIBER LOOSE -FILL INSULATION. CELLULOSIC FIBER LOOSE -FILL INSULATION SHALL COMPLY WITH CPSC 16 CFR, PARTS 12 9 AND 1404. H PACKAGE OF SUCH INSULATING MATERIAL SHALL BE 0 EACH CLEARLY LABELED IN ACCORDANCE WITH CPSC 16 CFR, PARTS 1209 AND 1404. R302.10.4 EXPOSED ATTIC INSULATION. L FLOORS EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC T /C F S SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER. FIRE BLOCKING DRAFTSTOPPING FBC 2017-RESIDENTIAL 6TH EDITION B G AND DRAFTS O ( ) R302.11 FIREBLOCKING. IN COMBUSTIBLE CONSTRUCTION, SHALL BE PROVIDED TO CUTOFF BOTH C LE CONSTRUC ON FIREBLOCKING VERTICAL AND HORIZONTAL CONCEALED DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAMED CONSTRUCTION IN ACCORDANCE WITH SECTIONS R302.11.1 THROUGH R302.11.2 R302.12 DRAFTSTOPPING. IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR -CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 M2). DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR -CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES: 1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. 2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS -TYPE OPEN -WEB OR PERFORATED MEMBERS. R302.12.1 MATERIALS. DRAFTSTOPPING MATERIALS SHALL BE NOT LESS THAN 1/2-INCH (12.7 MM) GYPSUM BOARD, 3/8-INCH (9.5 MM) WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE MAINTAINED. R302.14 COMBUSTIBLE INSULATION CLEARANCE. COMBUSTIBLE INSULATION SHALL BE SEPARATED NOT LESS THAN 3 INCHES (76 MM) FROM RECESSED LUMINAIRES, FAN MOTORS AND OTHER HEAT -PRODUCING DEVICES. R309.1 FLOOR SURFACE. GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. PROTECTION OF WOOD AGAINST DECAY (FBC 2017-RESIDENTIAL, 6TH EDITION) 317.1 LOCATION REQUIRED. PROTECTION OF WOOD AND WOOD -BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS INDICATED THROUGH SECTION R317 BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE -TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U1. TERMITES NOTE (FBC 2017-RESIDENTIAL, 6TH EDITION) R318.1 TERMITE PROTECTION. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. SEE SECTION 202, "REGISTERED TERMITICIDE." UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 V�^^J ♦♦ =^) N 1..1.E d' ::�; coIT- co a _I C� G 1 < U wwxx Cz W v , w M Z (0 Z U U) C v J O LU M Z I* -- co M � I .< / Or- LU V =7=1co-=�4c i5� ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (o) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn: H.S. Designed by H.S. Checked by: H.S. SCALE: NOTED A-5 Mi 09 A-06.pdf ■ ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 v J � N � d- Q r � M Q J Q U � 06 ry F- w U) o -a w z U U) c) o w CD z QD aC ry w (D 2Gi-2E'�J ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC , AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 L Date 8-JAN-21 Drawn: H.S. Designed by: H.S. Checked by: H.S. SCALE NOTED A-6 I n : / 1 r:' �. r > T ter`\ i , , Y /. �, \, t, ,f \ Ya . y > , < y i / < / f, \ \ y <-' \ > r Tom- J 7 T 1. r 1 T T \ 7 / i % %' < \f - - \ r /\ i. n\ f. \ S \'Y • • • • < is < �:<. :�-. • Y \ r, \ rr` IX i \r , 1 , ! < \ ti ;, >- �. >—A do 600 06 ' \ \" f. .. / r T r ,\ `i v \ / J /.. \: / n : , v < l •Y >' v \` f y '} \, 1, z r \ - , C , \ \r ✓ rE 1 x NA-1 -------------------------�i�-EVO-"-'--'-�..-a- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �'�-.'---------------------------------------•1�--------- --- %DRIUEUi�AY<�7N<EXACT;S ^ E ,SHAPE ' W iz \ � I I ��/ I LU LL. a- !CL = CL i i I - I I t i _ I E4 1 E3 EXISTING ROOF, 1 TO REMAIN i I 1 � I I I i I 1 I i I I I ; I I 1 1 xx (STING FLAT RO i TO REMAIN EXI ING TO REIVIA IN i i i ! i i E2 A-3 NO EXTERIOR WORK TO BE P'ERFUMEUI III' i ,OF. Flo by H ERNAN • I ••.SANTARCANGE BAN SANTARc,%, •'.� 0 AR96867 • i FRED'� 2021.07.23 r 11:49:04 -04' 00' PROPOSED ROOF P AN _ � SCALE I 1i4 . 1-0 11 Mi i Dade County Department of egulatory and Economic Resources Job Copy 092 A-07.pdf ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 Cl� � CV Q � M M o o u- Q V � 06 C]_ w -0 W M z U cn Q43 o W W 24c::>— ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLCAND MAY NOT BE DUPLICATED,, USED, OR " DISCLOSED WITHOUT THE EXPRESS - WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn: H.S. Designed by H.S. Checked by: H.S. SCALE: NOTED A-7 1, 0 0 *066 0 0 • 0 0 6 0 • 9 00 0 0 a 006 Go* 000 0000 :060 :*990 0 4, .0 :0040 :000 • 00049 • 60*0 • • A. STING ROOF ±12-6"J4 TTRUSSES -UNDERT ILIJ iu n L '16'-3" n17 COUNG FINISHES SHALL BE IN IN ACCORD= WITH (MM017-WA NFW RFnr!nnm EN-nX RW5.1) lN ) I I ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 .T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 06 r"Yoo UJ C) UJ U3 Uj CY) Uj (D ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date: 8-JAN-21 Drawn: H.S. Designed by: H.S. Checked by: H.S. SCALE NOTED A-9 A-09.pdf ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 V J N may- M O J (� LL Q � _J Q U � C z5 W W M Co -T- 3: U cn Cn c� W Cfl 0 re W CD ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC AND MAY NOT BE DUPLICATED,, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn H.S. Designed by: H.S. Checked by: H.S. SCALE: NOTED A-10 A-10.pdf EXTERIOR DOORS MARK QTY R.O. SYSTEM CONE. PAINT G.L.ASS (NEW MIAMI - DADE REGULATIONS) OBS. SCREEN MUNTINS WIDTH" HEIGHT" D-01 1 53 82 FRENCH DOOR + FIXED XO WHITE TO VERIFY ACCORDING TO MECHANICAL CALCULATIONS EGRESS NO FULL VIEW D-02 1 52 82 FRENCH DOOR X WHITE TO VERIFY ACCORDING TO MECHANICAL CALCULATIONS EGRESS NO FULL VIEW WINDOWS MARK -QTY - SYSTEM -CONE. PAINT G.L.ASS NEW MIAMI - DADE REGULATIONS � ) OBS. -SCREEN MUNTINS „ WIDTH HEIGHT. W-01 1 52 37 SLIDING WINDOW XX T.B.D. TO VERIFY ACCORDING TO MECHANICAL CALCULATIONS EGRESS YES FULL VIEW. W-02 1 52 37 SLIDING WINDOW XX T.B.D. TO VERIFY ACCORDING TO MECHANICAL CALCULATIONS EGRESS YES FULL VIEW W-03 1 34 37 FIXED 0 T.B.D. TO VERIFY ACCORDING TO MECHANICAL CALCULATIONS - NO FULL VIEW INTERIOR DOORS MARK QTY DOOR DIMENSION SYSTEM CONE. PAINT DOOR MATERIAL JAMB MATERIAL REMARKS HARDWARE WIDTH„ . HEIGHT" I- 1 0 1 32 82 SWING S I G X T.B.D. WOOD- WOOD T.B.D. 1-02 1 72 82 B1-FOLD XX T.B.D. WOOD WOOD T.B.D. 1-03 1 32 82 SWING X T.B.D. WOOD WOOD T.B.D. 1-04 1 72 82 BI-FOLD XX T.B.D. WOOD WOOD T.B.D. 1-05 1 32 82 SWING X T.B.D. WOOD WOOD T.B.D. 1-06 1 30 82 SWING X T.B.D. WOOD WOOD T.B.D. 1-07 1 72 82 BI-FOLD XX T.B.D. WOOD WOOD T.B.D. I-_08 1 30 82 POCKET X T.B.D. WOOD WOOD T.B.D. =DOOR AND WINDOWS SCHEDULE i Dade County Department of Regulatory and Economic Resources Job Copy 2 - FM • • • • • • • • • • • • • • • • • • • • . • • • . • • • f . •••• as •• . ••• :some •00• • • • • . • •.i• ! •• •• • •.• • ••.• • AREA OF BLEAR OPENING 5.7 SQ�FT---f IIN.) "WINDOWS TO HAVE LO W E IMPACT G.L.ASS �. 'ALL ALUMINUM FINISHES TO BE DETERMINED LL BY OWNER *PROVIDE CATEGORY ll SAFETY G.L.ASS AT G.L.ASS PANELS ADJACENT TO DOORS 20" (MIN.) "ALL GLASS SHALL HAVE A MAX U-FACTOR = � 1 & A SHGC= 0.50 (ELEVATION -INSIDE LOOKING OUT) 'CONTRACTOR TO FIELD VERIFY. ALL OPENING &DIMENSIONS AND SUBMIT SHOP DRAWING FOR ARCHITECTS APPROVAL PRIOR TO WINDOW OL F.F.L. FABRICATION. EGRESS WINDOW DETAIL SECTION R310 - EMERGENCY ESCAPE AND RESCUE OPENINGS R310.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES. EMERGENCY ESCAPE AND RESCUE OPENINGS HALL BE OPERATIONAL FROM THE INSIDE c s oP to 0 OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM F2090 SHALL BE PERMITTED FOR USE ON WINDOWS SERVING AS A REQUIRED EMERGENCY ESCAPE AND RESCUE OPENING. R310.2.1 MINIMUM OPENING AREA. EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET (0.530 M2). THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES (610 MM) AND THE NET CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES (508 MM). R310.2.2 WINDOW SILL HEIGHT. WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPE AND RESCUE OPENING, IT SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES (1118 MM) ABOVE THE FLOOR; WHERE THE SILL HEIGHT IS BELOW GRADE, IT SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2.3. SECTION R311 - MEANS OF EGRESS R311.2 EGRESS DOOR. NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE SIDE -HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32 INCHES (813 MM) WHERE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES (1.57 RAD). THE CLEAR HEIGHT OF THE DOOR OPENING SHALL BE NOT LESS THAN 78 INCHES (1981 MM) IN HEIGHT MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM DIMENSIONS. EGRESS DOORS SHALL BE READILY OPENABLE FROM INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SECTIONR312 - GUARDS AND WINDOW FALL PROTECTION R312.2 WINDOW FALL PROTECTION. WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R312.2.1 AND R3122.2. R312.2.1 WINDOW SILLS. IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WINDOW OPENING IS LOCATED LESS THAN 24 INCHES (610 MM).ABOVE THE FINISHED FLOOR AND GREATER THAN 72 INCHES (1829 MM) ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE WINDOW SHALL COMPLY WITH ONE OF THE FOLLOWING: 1. OPERABLE WINDOWS WITH OPENINGS THAT WILL NOT ALLOWA 4-INCH-DIAMETER (102 MM) SPHERE TO PASS THROUGH THE OPENING WHERE THE OPENING IS IN ITS LARGEST OPENED POSITION. 2. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT COMPLY WITH ASTM F2090. 3. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH SECTION R312.2.2. 4. R312.2.2 WINDOW OPENING CONTROL DEVICES. WINDOW OPENING CONTROL DEVICES SHALL COMPLY WITH ASTM F2090. THE WINDOW OPENING CONTROL DEVICE, AFTER OPERATION TO RELEASE THE CONTROL DEVICE ALLOWING THE WINDOW TO FULLY OPEN, SHALL NOT REDUCE THE NET CLEAR OPENING AREA OF THE WINDOW UNIT TO LESS THAN THE AREA REQUIRED BY SECTION R310.2.1. FLORIDA BUILDING CODE - NOTES Digitally signed by HERNAN y: SANTARCANGE • o "L_O 'A AR96867 �4V c��'FR 2021.07.258 ED A 11:51:53-04'00' ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 Q U) =) tV CM M O J 0 L.L J Q U � 06 _ ry W C J M W M C� U U) v) o W csi ry rrW V 24=0-2<Ei'- ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn: H.S. Designed by: H.S. Checked by: H.S. SCALE: NOTED A-11 A-11.pdf ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 V J Cv M C� U— Q � J � U � 06 W U W M U U) to o W z ti c� 0 aC rVoo W C� ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (c) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date: 8-JAN-21 Drawn: H.S. Designed by H.S. Checked by: H.S. SCALE: NOTED A-12 A-12.pdf ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com HernanSantarcangelo, Architect NCARB AR# 96867 V J � N � d- Q: � % M (D M 0 aC � � Q U � ry w M W M Z CU U U) U3 O Uj 0 Q W 2C>-2A=—�� ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (c) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn H.S. Designed by: H.S. Checked by: H.S. SCALE: NOTED A-13 /. .\. 7.211 8211IV ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 V J � N � d- M M O Q � Q U- ry W M zQD V c� to o w c� Z Q W ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9- L Date 8-JAN-21 Drawn H.S. Designed by: H.S. Checked by: H.S. SCALE: NOTED A-14 ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 V ) = C.V 0 d- M M O p u_ Q � Q- U o Cl ID W M z c. -T- 3;: U U3 U3 o w CD z r-- ._ C-0 0 Q o w ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn H.S. Designed by: H.S. Checked by: H.S. SCALE: NOTED A-15 A-15.pdf WALL/FLOOR FINISH BACKER BOARD WALL — OPT. WATERPROOF MEMBRANE HOT MOP LA PROLINE DRAIN ASSEMBLY REINFORCEDCONCRETE BASE 02%-4% SLOPE THINSET SUB -FLOOR LEVELING BRACKET SADDLE CROSS SECTION S1 PROLINE DRAIN WITH HOT MOP PAN LINER TILE FINISH 11/2TEMPERED G.L ASS (POLISHED EDGES) TILE ON " DUROCK (6' HIGH MIN) ANNEL WALL/FLOOR FINISH BACKER BOARD STEP OPT. WATERPROOF MEMBRANE SHOWER PAN: HKzr MOP LAYER ASPHALTUM COATED SHOWER REINFORCED CONCRETE BASE WZ-4% SLOPE PAN OVER 1" LAYER OF SAND OVER 30" ASPHALT SATURATED FELT (OR EQUAL) THINSET SUB -FLOOR CROS&SECTION S2 PROLINE DRAIN WITH HOT MOP PAN LINER SHOWER NOTE SHOWER/BATHTUB COMPARTMENT MUST HAVE FLOOR AND WALLS CONSTRUCTED OF SMOOTH, CORROSION RESISTANT AND NONABSORBENT WATER RESISTANT MATERIALS TO A HEIGHT OF NOT LESS THAN 72• (INCHES) AVOVE THE COMPARTMENT FLOOR AT THE DRAIN. (TYP.) PER FBC.2014 INSTALLATION FBC. RES 2709 Lining materials shall be sloped one—fourth unit vertical in 12 units horizontal (2% slope) to weep holes in the subdrain by means of a smooth, solidly formed subbase, shall be property recessed and fastened to approved backing so as not to occupy the space r used for the wall covering, and shall not be nailed or perforated at any point less ,than 1! above the finished fhred�. SHOWER DRAIN DETAIL (TYP) SHOWER PAN DETAIL (TYP 9 SCALE N.T.S. 10 SCALE N.T.S. V .7 6+'J. V L / V .J V 7 / J / G V- A-16 pdf 00*0 • • • o • • • • • • • • • • • • • • • ! .... • • . • . . • 000 ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atelierint.com Hernan Santarcangelo, Architect NCARB AR# 96867 Q Z CV r %%e cM O Cy') � L.L Q � Q U � 06ry _ W U3 r-,) _C3 W M U C3 U� O Lu M Q Uj 2C�-2s� J ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC, AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF ATELIER INTERNATIONAL LLC (c) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date: 8-JAN-21 Drawn: H.S. Designed by: H.S. Checked by: H.S. SCALE: NOTED A-16 Mi i Dade County Department of Regulatory and Economic Resources - Job Copy I A-17.pdf ATELIER INTERNATIONAL LLC 1800 SW 1st Avenue Suite 307 Miami, FL 33129 T 305-374-9084 C 786-302-5236 www.atellerint.com Hernan Santarcangelo, Architect NCARB AR# 96867 V J � CV M O M J Q 00 W U) W M Z -T- 3: U U) to o ud rn Z ti. 0 Q ry w ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF ATELIER INTERNATIONAL LLC , AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS - WRITTEN CONSENT OF ATELIER - INTERNATIONAL LLC (C) 2018 # DATE DESCRIPTION 1 ORIGINAL ISSUE 2 3 4 7 8 9 10 Date 8-JAN-21 Drawn: H.S. Designed by: H.S. Checked by H.S. SCALE: NOTED A-17 I STRUCTURAL NOTES CODES: SHOP DRAWINGS AND OTHER SUBMITTALS: MASONRY: WELDED WIRE MESH: ••• •••• • • • _ WELDED WIRE MESH 'SHALL BE -ASTM -A-185 GRADE 65 FREE FROM OIL THE STRUCTURAL FRAMING WAS DESIGNED USING THE FOLLOWING CODES 1. REVIEW OF SUBMITTALS BY THE STRUCTURAL ENGINEER IS FOR 1. FOR NON BEARING WALLS ONLY, LAY UP ALL MASONRY UNITS AFTER - CONCRETE PLACEMENT OF NEXT STORY. SECURE MASONRY TO COLUMNS SCALE, AND RUST, AND SHALL BE PLACED IN `ACCORDANCE WITH THF� ACI-. GENERAL NOTES: GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AS PRESENTED BY TYPICAL DETAILS. MINIMUM LAP SHALL -BE ONE SPACE PLUSW ' 1 BUILDING CODE : FLORIDA BUILDING CODE 2020, 7TH ED. THE CONTRACT DOCUMENTS: NO DETAILED CHECK OF QUANTITIES OR WITH GALVANIZED DOVETAIL ANCHORS IN EVERY OTHER COURSE (OR Q • • • •• � i 1. NO DIMENSIONS SHALL BE SCALED FROM DRAWINGS. CONCRETE ACI 318-14 DIMENSIONS WILL BE MADE. ONLY THOSE SUBMITTALS REQUIRED BY THE APPROVED EQUAL): INCHES. .. - STEEL RISC360-16 CONTRACT DOCUMENTS TO BE SUBMITTED WILL BE REVIEWED. ALL OTHERS - - A A W A , 2. GENERAL CONTRACTOR SHALL. CHECK, REVIEW AND VERIFY ALL PLANS, MASONRY ACI 530 13 WILL BE RETURNED WITHOUT COMMENT. 2 CONSTRUCT REINFORCED MASONRY IN ACCORDANCE WITH CI 530, �� :0•0• DIMENSIONS AND SITE CONDITIONS PRIOR TO CONSTRUCTION. THE WOOD NDS 2015 "BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY STRUCTURES WIND ASCE 7-16 2. BEFORE SUBMITTING THE .FIRST SHOP DRAWING, SUBMIT THE SHOP AND/OR "SPECIFICATIONS FOR THE DESIGN AND CONSTRUCTION. OF REINFORCING STEEL. CONSULTING ENGINEERS ENGINEER OF RECORD SHALL BE NOTIFIED IN WRITING OF ANY / » ;••,• �;•,� •,,.' ;...' . DISCREPANCIES OR OMISSIONS NOTED ON THE DRAWINGS OR IN THE DRAWING SUBMITTAL SCHEDULE, PREPARED BY THE CONTRACTOR TO THE LOAD -BEARING CONCRETE MASONRY N:C.M.A: LAY UP MASONRY UNITS IN STRUCTURAL. ENGINEER CONSISTENT WITH THE FOLLOWING CRITERIA: 1. ALL REINFORCING STEEL SHALL BE DEFORMED BARS, FREE FROM : CA # 30228 SPECIFICATIONS, OR ANY VARIATIONS NEEDED IN ORDER TO CONFORM TO RUNNING BOND. LOOSE RUST AND SCALE CONFORMING TO ASTM A615 (S1), Fy=60 KSI, 2420 NE Miami Gardens Dr THE CODES, RULES AND REGULATIONS. STE 203 A. ALLOW ADEQUATE TIME FOR TRANSIT AND PROCESSING BEFORE U.O.N.. 3. USE CONCRETE- MASONRY UNITS, TO ASTM C90 GRADE Miami, FI.33180 .CONCRETE. 3. ALL REFERENCED STANDARDS REFER TO THE EDITION ENFORCED AT FABRICATION. THE STRUCTURAL ENGINEER WILL REVIEW AN AVERAGE N-1. MINIMUM COMPRESSIVE STRENGTH OF ANY UNIT SHALL BE OF : 305 508 0161 2 ALL REINFORCING SHALL BE DETAILED AND FABRICATED FOLLOWING. P SUBMITTAL WITHIN 14 CALENDAR DAYS OF RECEIPT BY THEM.: = e: en ineerin en 4build.com THE TIME THESE PLANS AND SPECIFICATIONS ARE ISSUED FOR BID: 1;900PSI FOR AN f m 1;500 PSI: USE .ONLY MASONRY UNITS THAT AREA THE RE UIREMENTS OF, ACI 315. PLACING OF `REBARS SHALL CONFORM g g@ g 1. ALL REINFORCED CONCRETE DESIGN _SHALL BE IN ACCORDANCE WITH Q „ >, MINIMUM OF 50% SOLID w: eng4bulld.com BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE ACI-318 . B. SCHEDULE AND SUBMIT SHOP DRAWINGS FOR SPECIFIC COMPONENTS,TO CRSI RECOMMENDED PRACTICES FOR PLACING' REINFORCING BARS". 4. THESE NOTES SHALL. BE USED IN CONJUNCTION WITH THE ( ) SPECIFICATIONSI SUCH A COLUMNS, FOOTINGS, ETC., IN THEIR ENTIRETY. SHOP DRAWINGS SUBMIT SHOP DRAWINGS. ISSUED BY THE ARCHITECT: 4. TEST ONE SET OF MASONRY UNITS IN ADVANCE OF :BEGINNING SEAL: 2. ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH FOR SIMILAR FLOORS SHALL BE SUBMITTED IN THE SAME PACKAGE. „ „ OPERATIONS AND ONE SET DURING CONSTRUCTION FOR EACH 5,000 SQFT SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS ACI-301 . SUBMIT SHOP DRAWINGS IN A TIMELY MANNER CONSISTENT WITH THE 3. MINIMUM CONCRETE COVER ON REINFORCING STEEL FOR VALID ONLY WITH 5. STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH ( ) OF WALL AREA. SAMPLE FROM ACTUAL FIELD UNITS. ABOVE: NON -PRESTRESSED CONCRETE SHALL BE AS `FOLLOWS, U.O.N. ARCHITECTURAL, AIR CONDITIONING, MECHANICAL AND ELECTRICAL PE SEAL & SIGN. 3. CONCRETE STRENGTH AT 28 DAYS SHALL BE 3 000 PSI. MODULUS OF „ •� DRAWINGS TO LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS � 5. USE TYPE M 2 800 PSI MORTAR IN ACCORDANCE WITH ASTM C270 - VALID FOR 1 PERMIT ONLY. RECESSES OPENINGS REGLETS BOLT SETTINGS SLEEVES ETC. ELASTICITY OF CONCRETE MIX SHALL BE NOT LESS THAN 57,000 of C. 3. REVIEW OF SHOP DRAWINGS IS LIMITED TO TWO (2) REVIEWS PER » ( ) MINIMUM 'COVER , > USE 3/8 FULL -BEDDED JOINTS. FOR ALL MASONRY `.UNITS.. REMOVE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE SUBMITTAL WITHIN THE SCOPE OF BASIC SERVICES (I.E., INITIAL A CAVITIES THAT ARE TO E REINFORCED " M• F °° MORTAR PROTRUDING INTO CELL C ITIE T E B RE E CAST AGAINST AND PERMANENTLY 3 ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. 4. MIX DESIGNS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL SUBMITTAL REVIEW AND ONE RESUBMITTAL, IF NECESSARY). REVIEW OF A A AR 0 U F '•�C PRIOR TO .COMMENCEMENT OF ANY CONCRETE WORK. ND GROUTED. ALLOW MIN: OF 24 HRS FOR MOAT T C RE BE ORE EXPOSED TO EARTH. ,.;:��cENsF •� ADDITIONAL RESUBMITTALS WILL BE CONSIDERED ADDITIONAL SERVICES, PLACING GROUT.•e Digitally signed by Andres M Felicia yf. 6. GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE FOR WHICH THE GENERAL CONTRACTOR MAY BE HELD RESPONSIBLE. - EXPOSED TO EARTH OR WEATHER. DN. c=US o=en ineerin for build - No. 75404 ENGINEER FOR APPROVAL BEFORE FABRICATION OR ERECTION OF ANY 5. NO ADMIXTURE SHALL BE PERMITTED WITHOUT THE WRITTEN APPROVAL ADDITIONAL SERVICES COMPENSATION TO THE ENGINEER WILL BE IN _ 9 g - 6. USE ALL GROUT CONFORMING TO ASTM C 476 WITH A MIN. No. ` 5 AND SMALLER BARS 1 1 2 dnQualifier=AO1410C000001791 ;. 3B = ; STRUCTURAL SYSTEM. OF THE ENGINEER. ACCORDANCE WITH THE TERMS OF .THE ARCHITECT -ENGINEER AGREEMENT COMPRESSIVE STRENGTH OF 3,000 PSI IN 28 DAYS, TESTED IN / _ FOR THIS PROJECT. ACCORDANCE A T C MAX. AGGREGATE SIZE OF 3 8" AND No. 6 AND LARGER BARS 2 69000005CBC, cn-Andres M Feliano 4® WITH ASTM 39, /.�: k/® 7. GENERAL CONTRACTOR SHALL RESTRICT AND PROPERLY ISOLATE ALL 6. FORM WORK SHALL COMPLY WITH "RECOMMENDED PRACTICE FOR „ Date:2021.06.11 09:30:4 0 0 00 °. ATE OF SLUMP OF 8 TO 10 . TEST SAMPLE FOR COMPRESSIVE STRENGTH TEST .• CONSTRUCTION EQUIPMENT AND LOADS FROM INCLUDING OR CONCRETE FORM WORK" (ACI-347R). 4. ALL .SUBMITTALS SHALL BE. ACCOMPANIED BY A LETTER OF NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: � . T ORION- TRANSMITTING. VIBRATIONS TO THE STRUCTURE DURING CONSTRUCTION. TRANSMITTAL. DO NO COMBINE DIFFERENT SUBMITTAL ON THE SAME EVERY 30 YARDS OR EACH DAYS GROUTING. 2,500 PSI PUMP MIX READY ROOF SLAB 1" �ii '" 7. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR SAFE TRANSMITTAL. MIX CONCRETE MADE WITH MAX. 3/8" AGGREGATE AND MAX. 9" SLUMP STRUCTURAL SLABS AND WALLS 1S AN ACCEPTED ALTERNATE. TESTS SHALL BE TAKING EVERY 30 CUBIC . 8. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSAL OF ALL ADEQUATE SHORING, RE -SHORING, _BRACING AND FORM WORK. GENERAL BEAMS AND COLUMNS (PRIMARY REINFORCEMENT; GROUTING. n .YARD AT A MINIMUM OF EACH :DAYSAndres M. Feliciano ACCUMULATED WATER FROM EXCAVATIONS AND DEWATERING OPERATIONS CONTRACTOR SHALL CONTRACT A STATE OF FLORIDA REGISTERED 5. ALL SHOP DRAWINGS MUST BEAR EVIDENCE OF THE CONTRACTORSTIES, STIRRUPS AND SPIRALS 1 1 2 TO TIES / ( ) FI Re P.E. # 75404 IN SUCH A WAY AS TO NOT CAUSE INCONVENIENCE TO THE WORK AND ENGINEER TO :PREPARE SHORING AND RE SHORING PLANS TO BE APPROVAL- PRIOR TO SUBMITTING TO THE A/E. SLABS ON GRADE 1 1 2 g DAMAGE TO THE STRUCTURAL ELEMENTS: SUBMITTED TO THE ENFORCEMENT AGENCY FOR RECORD. KEEPING. 7. USE STANDARD No. 9 GAGE LADDER :TYPE MASONRY REINFORCING IN / EVERY OTHER COURSE (U.O.N.). USE PREFABRICATED CORNERS AND 'TEES 6. SUBMIT ONE REPRODUCIBLE AND TWO BLUELINE PRINTS TO THE 4. NO DEVIATION.. FROM THE -STRUCTURAL':PLANS :SHALL BE PERMITTED AT WALL INTERSECTIONS. OVERLAP DISCONTINUOUS ENDS A MIN. OF 12". 9. WHEN PERFORMING WORK BELOW GRADE, CARE SHALL BE TAKEN TO 8. THE OWNER SHALL CONTRACT AN INDEPENDENT TESTING LABORATORY ARCHITECT ENGINEER WILL RETURN THE REPRODUCIBLE AND RETAINWITHOUT THE EXPRESS WRITTEN CONSENT OF THE STRUCTURAL ENGINEER: AVOID DAMAGING ANY EXISTING UTILITIES. ALL UNKNOWN UTILITIES APPROVED BY THE ENGINEER TO PERFORM CONCRETE CYLINDER TEST AS HORIZONTAL REINFORCING SHALL CONFORM TO ASTM A-82 BLUELINES AFTER. REVIEW. ALL REINFORCING DETAILS SHALL BE SUBMITTED TO THE .ENGINEER FOR DISCOVERED DURING CONSTRUCTION SHALL BE BROUGHT TO THE FOLLOW: FOUR CYLINDER TEST FOR ANY 50 CUBIC YARDS OF CONCRETE HIS APPROVAL 5 FTSFF ATTENTION OF THE ARCHITECT ENGINEER. ANY DAMAGE TO EXISTING / POURED OR THREE CYLINDER TEST PER ANY DAYS POUR LESS THAN 50 � 7. ALL CHANGES AND ADDITIONS MADE ON RE -SUBMITTALS MUST BE 8. USE GROUTED CELLS WITH: REINFORCING AS INDICATED. INTERSECTIONS, ' UTILITIES SHALL BE REPORTED TO ALL AFFECTED PARTIES, INCLUDING THE CUBIC YARDS. CLEARLY FLAGGED AND NOTED. THE PURPOSE OF THE RE -SUBMITTALS EACH SIDE OF OPENINGS IN THE WALL AND AT THEENDS OF WALLS USE 5. ALL REINFORCING BARS SHALL BE SECURELY HELD IN PLACE DURING ARCHITECT/ENGINEER. MUST BE CLEARLY NOTED ON THE LETTER OF TRANSMITTAL. 1 #6 IN FILLED CELL (U.O.N.). CONCRETE POURING. IF REQUIRED, ADDITIONAL BARS SHALL BE PROVIDED 9. TRANSPORTING, PLACING, CURING AND DEPOSITING OF CONCRETE ARCHITECT/ENGINEER REVIEW WILL BE LIMITED TO THOSE ITEMS CAUSING BY THE CONTRACTOR TO FURNISH SUPPORT FOR THE BARS. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR UPDATING HIS SHALL COMPLY WITH ACI 301. THE RE -SUBMITTAL. 9, USE BAR SPACERS IN EVERY_6TH COURSE WHERE CELLS ARE TO BE CONSTRUCTION DOCUMENTS WITH ANY REVISED DRAWINGS AND GROUTED. SPECIFICATIONS, FIELD ORDERS, CHANGE ORDERS AND CLARIFICATION THE SLAB DING 1 3 10. NO PIPES OR CONDUITS EXCEEDING / K ESS IN THICKNESS 8. DO NOT REPRODUCE STRUCTURAL CONTRACT DOCUMENTS FOR ' 6. BARS SUPPORTS SHALL BE PLASTIC TIPPED FOR EXPOSED CONCRETE: K SKETCHES ISSUED DURING THE COURSE OF CONSTRUCTION. OUTSIDE DIAMETER SHALL BE EMBEDDED IN THE STRUCTURAL CONCRETE .THE USE AS SHOP DRAWINGS. 10. PROVIDE CLEANOUT OPENINGS FOR EACH GROUTED CELL. "DONUT" LEGS OF FOUNDATIONS ,CHAIRS SHALL BE GALVANIZED. PLASTIC DONUT FLOOR OR ROOF WITHOUT WRITTEN APPROVAL FROM THE ENGINEER. SPACERS WILL BE REQUIRED FOR STEEL AGAINST FORM IN CONCRETE 11. "BY OTHERS" DENOTES LABOR. AND MATERIALS BY OTHERS. HOWEVER WHERE PIPES OR CONDUITS ARE PERMITTED, THEY SHALL BE PLACED NO 9. -SHOP DRAWINGS NOT MEETING THE .ABOVE CRITERIA OR SUBMITTED 11. USE ATM A-615 GRADE 60 REINFORCING STEEL. BEAMS &WALLS IF FIELD CONDITIONS WARRANT. THE GENERAL CONTRACTOR SHALL PROVIDE `COORDINATION AND FREE.. CLOSER THAN THREE DIAMETER 0 C AND SHALL BE LOCATED SO A / SNOT AFTER. FABRICATION WILL NOT BE REVIEWED: � ,. NOT ACCESS FOR THE WORK. REFER TO SPECIALTY ENGINEERING NOTES. TO IMPAIR T STRENGTH OF THE STRUCTURE. JUNCTION BOXES HE MAY Y BE 12IN HIGH -LIFT GROUTING USE A MAX. LIFT OF 4 -0 WITH LESS 7. WELDED WIRE FABRIC SHALL CONFORM WITH ASTM A185 AND IT SHALL PLACED IN STRUCTURAL CONCRETE SLABS BUT SHALL NOT EXCEED 10. FOR ADDITIONAL CRITERIA APPLICABLE TO SHOP DRAWINGS REQUIRING THAN. 30 MINUTES NOR MORE THAT ONE HR ,BETWEEN LIFTS: VIBRATE BE SUPPORTED ON SLAB BOLSTERS. USE FLAT SHEETS ONLY. ;, - 12. N.I.C. DENOTES NOT IN CONTRACT: THE. OWNER SHALL. BE „ P B SEPARATED 4Y2 x4Y2 x3Y2 IN DEPTH, AND SHALL E FROM -OTHER ENGINEERING INPUT BY A SPECIALTY ENGINEER, SEE. SPECIALTY. ENGINEER ENGI ER IN ER EACH LIFT AND RECONSOLIDATE PREVIOUS LIFT AFTER PLACING NEXT. RESPONSIBLE FOR COORDINATING A TIME SCHEDULE OF THE BASE JUNCTION BOXES BY NOT LESS THAN 8". NOTES. 13. REINFORCED MASONRY WALL CONSTRUCTION SHALL BE INSPECTED BY 8. REINFORCING IS DENOTED ON PLANS THUS: CONTRACT WITH THE "N.I.C.". A STATE OF FLORIDA CERTIFIED ENGINEER OR ARCHITECT IN ACCORDANCE BOTTOM BARS ---------- TOP BARS B 11. NO WATER SHALL E ADDED TO THE CONCRETE AT THE JOB SITE. SPECIALTY DELEGATED ENGINEERING NOTES: WITH ACI. - ------------ 13. TYPICAL DETAILS AND NOTES ON THESE DRAWINGS SHALL APPLY FOR SIZE AND SPACING OF REINFORCING SEE PLANS, SCHEDULES AND UNLESS SPECIFICALLY NOTED OTHERWISE. CONSTRUCTION DETAILS AND 12. ALL PLUMBING & ELECTRICAL SLOTS SHALL BE FILLED WITH 14. WHERE ANCHORS BOLTS ARE SET IN MASONRY WALL, FILL BLOCKS DETAILS: SECTIONS: NOT COMPLETELY SHOWN OR NOTED SHALL BE SIMILAR TO CONCRETE' TO THE TOP OF THE FLOOR SLAB AFTER PIPING OR CONDUIT 1. SPECIALTY DELEGATED_ ENGINEER. CELLS WITH GROUT FOR BOLTED COURSE, ONE COURSE ABOVE AND TWO ; "CONTINUOUS" DETAILS AND SECTIONS .SHOWN OR NOTED FOR SIMILAR- CONDITIONS. IS INSTALLED. COURSES BELLOW ANCHOR ELEVATION. 9: ALL REINFORCING BARS MARKED :.SHALL BE LAPPED AT A. DEFINITION: A FLORIDA REGISTERED PROFESSIONAL ENGINEER, NOT THE SPLICES AND CORNERS UNLESS OTHERWISE NOTED. LAP CONTINUOUS TOP 14. THE GENERAL. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR: ALL 13. ALL. BEAMS, SPANDREL -BEAMS &FLOOR SLABS, SHALL BE PLACED STRUCTURAL ENGINEER OF RECORD, WHO SPECIALIZES INAND WHO W ' - 15. USE PRESSURE-TRATED WOOD FOR ALL WOOD IN CONTACT WITH BARS AT CENTER BETWEEN 'SUPPORTS AS REQUIRED: TERMINATE EXCAVATION PROCEDURES INCLUDING .LAGGING, SHORING, AND PROTECTION MONOLITHICALLY AND THE FLOOR SLAB- FINISHED AS REQUIRED ON THE UNDERTAKES THE DESIGN OF STRUCTURAL COMPONENTS OR STRUCTURAL MASONRY. CONTINUOUS BARS AT NOT -CONTINUOUS .ENDS WITH STANDARD.. HOOKS. OF ADJACENT PROPERLY, STRUCTURES, STREETS AND UTILITIES IN SPECIFICATIONS. SYSTEM INCLUDED IN A SPECIFIC SUBMITTAL PREPARED FOR THIS U.O.N. ACCORDANCE WITH THE LOCAL BUILDING DEPARTMENT. PROJECT. - 16. PROVIDE LINTELS OR HEADERS OVER ALL MASONRY OPENINGS NOT 14. VERTICAL CONSTRUCTION JOINTS USING APPROVED BULKHEADS MAY „ FLUSH WITH STRUCTURAL FRAME. LINTELS OR HEADERS TO BEAR MIN. 8 10. ALL WALLS AND COLUMNS SHALL BE DOWELED INTO <FOOTINGS, 15. BACK FILL AROUND THE EXTERIOR PERIMETER OF WALL SHALL NOT BE MADE AT CENTER OF BEAM OR SLAB SPANS WHERE STOP IN B. SHALL BE: WALLS, BEAMS, OR SLABS WITH BARS OF THE SAME , SIZE < AND SPACING BE PLACED. UNTIL AFTER THE WALLS ARE SUPPORTED BY THE - CONCRETE WORK IS NECESSARY: FOR ADDITIONAL REINFORCING- AT - AN EMPLOYEE OR OFFICER OF A FABRICATOR. SIDE OF OPENING. EACH - - - AS THE. BARS ABOVE: USE A (36) BAR DIAMETER LAP EXCEPT" WHERE COMPLETION OF INTERIOR FLOOR SYSTEMS. DO NOT PROCEED WITH BACK CONSTRUCTION JOINTS SEE DETAILS. ANY OTHER CONSTRUCTION JOINT - AN EMPLOYEE OR OFFICER OF AN ENTITY SUPPLYING COMPONENTS TO. SPECIFICALLY INDICATED OTHERWISE. E FILL UNTIL (7) DAYS AS A MINIMUM AFTER THE COMPLETION OF INTERIOR REQUESTED BY THE GENERAL CONTRACTOR SHALL BE SHOWN ON THE A FABRICATOR. 17. ALL BEAMS NOT SCHEDULED ARE TIE BEAMS AND SHALL BE 8x12 . FLOOR SYSTEMS UNLESS WALLS ARE ADEQUATELY BRACED. BACK FILL SHOP DRAWINGS FOR THE ENGINEER REVIEW. - AN INDEPENDENT CONSULTANT RETAINED BY THE FABRICATOR OR HIS MIN. WITH 2 5 LONGITUDINAL BARS TOP AND BOTTOM AND 3 TIES_ � 12" # # 11. VERTICAL WALLS BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES, SHALL NOT BE PLACED UNTIL AFTER ` COMPLETION AND INSPECTION OF SUPPLIER. O.C. MAX. AND AT CORNERS USE 2#5 TOP AND BOTTOM CORNERS BARS SPLICE BARS IN SPANDRELS, WALLS, BEAMS, GRADE BEAMS, ETC., WATERPROOFING WHERE WATERPROOFING OCCURS. 15. REMOVE ALL DEBRIS FROM FORMS BEFORE POURING. WITH 30 LEGS. (U.O.N.) AS FOLLOW;. TOP BARS AT CENTER LINE SPAN, BOTTOM BARS 2. SUBMISSIONS AND RE -SUBMISSIONS FOR CUSTOM DESIGNED, AT THE SUPPORT. 16. TEMPORARY BRACING SHALL BE PROVIDED AS REQUIRED TO HOLD 16. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL MANUFACTURES OR FABRICATED LOAD -CARRYING ITEMS AND CUSTOM 18. ALL COLUMNS NOT SCHEDULE ARE TIE COLUMNS AND SHALL BE ALL OF THE STRUCTURE 1N PLACE -UNTIL FINAL SUPPORT IS AS IN WALLS COLUMNS SO AS TO CAUSE SEGREGATION OF ( � ) FABRICATED. ITEMS WHICH ARE REQUIRED BY CODES OR STANDARDS TO 8 x12 MIN. WITH 4#5 VERTICAL BARS AND #3 TIES @ 8 O.C. .COMPONENTS SECURELY ANCHORED. AGGREGATES. USE HOPPERS, CHUTES OR TRUNKS OF VARYING LENGTHS RESIST FORCES AND STRESSES, INCLUDING THEIR CONNECTIONS, ._ . SO THAT THE FREE UNCONFINED FALL OF CONCRETE SHALL NOT EXCEED ANCHORAGES AND ATTACHMENTS REQUIRE A SPECIALTY ENGINEER. 19. PROVIDE 48 TIMES BAR DIAMETER TO VERTICAL REINFORCING SPLICE E q IN CMU WALLS 17. THE CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES OF EVERY KIND, INCLUDING WATER AND POWER, .TIED , AND -A UICNT MBER- SHLL BE USED TO ENSI NUURE THE - CONCRETE IS BEING KEPT LEVEL AT ALL TIMES. 3: THE FOLLOWING SYSTEM AND COMPONENTS, AS A MINIMUM, REQUIRE NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHOWN OR FABRICATION AND ERECTION DRAWINGS WITH INPUT BY SPECIALTY 20. EXISTING 8" MASONRY WALLS TO BE RAISED MUST BE REINFORCED INDICATED ON THESE DRAWINGS: ALL MATERIALS SHALL BE NEW ENGINEER: W/1#5 @ 32" O/C MAX. (UNLESS OTHER .NOTICE).. MATERIALS AND WORKMANSHIP SHALL BE OF GOOD QUALITY. ALL - RAILINGS, EXTERIOR DOORS AND WINDOWS, SHORING AND - RESHORING. WORKMEN AND SUBCONTRACTORS SHALL BE SKILLED IN THEIR TRADE. - STEEL STAIRS, STAIRS PRECAST CONC. . 21. NEW 8" AND 10" MASONRY WALLS MUST BE REINFORCED W/1 #5 SOIL STATEMENT ® 32" O/C MAX. (UNLESS NOTICE). 18. THE CONTRACTOR SHALL ADEQUATELY PROTECT HIS WORK, BASED ON VISUAL INSPECTION AT THE JOB SITE, THE FOUNDATIONS HAVE 4. FOR EACH CATEGORY OF SHOP DRAWINGS REQUIRING INPUT FROM A SPECIALTY ENGINEER, THE CONTRACTOR SHALL ATTACH TO THE FIRST .OTHER ADJACENT PROPERTY AND THE PUBLIC, AND BE RESPONSIBLE FOR BEEN DESIGNED FOR AN ALLOWABLE (WELL COMPACTED SAND/GRAVEL) SHOP DRAWING SUBMITTAL A SIGNED AND SEALED LETTER. FROM THE 22• PROVIDE 20 GAGE HOT DIPPED GALVANIZED DOVETAIL ANCHORS DAMAGE OR INJURY DUE TO HIS ACT OR NEGLECT: BEARING CAPACITY OF 2,000 P.S:F RESPONSIBLE SPECIALTY ENGINEER STATING, I CERTIFY THAT THE DESIGN SLOTS VERTICALLY IN STRUCTURAL COLUMNS AND TIE COLUMNS NOT 19. THE PREMISES SHALL BE KEPT FREE R ACCUMULATION OF WASTE E EE FROM L N AT THE TIME OF CONSTRUCTION, THE ENGINEER SHALL SUBMIT TO THE AND DRAFTING OF THE SHOP DRAWINGS WHICH ARE SIGNED AND SEALED PLACED INTEGRALLY WITH CMU WALLS THAT ARE ABUTTED BY NON -LOAD BEARING MASONRY WALLS CMU UNITS SHALL BE INTO COLUMNS MATERIALS,AND DEBRIS AND AT THE N 0 THE JOB THE H END F E BUILDING OFFICIAL A LETTER ATTESTING THAT THE SITE HAS BEEN BY ME .WERE PREPARED UNDER MY DIRECT SUPERVISION AND CONTROL „ ,, " WITH 1 x8 x16 GAGE CORRUGATED HOT DIPPED GALVANIZED DOVETAIL CONTRACTOR SHALL REMOVE ALL RUBBISH- SURPLUS MATERIALS AND- ' OBSERVED & CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE AND TO THE BEST F P DRAWING COMPLY WITH 0 MY KNOWLEDGE THE SHOP S ANCHORS. .TOOLS AND LEAVE THE BUILDING BROOM. CLEAN. DESIGNED IS BASED. THE APPLICABLE MINIMUM BUILDING CODES AND THE CONTRACT DOCUMENTS.,, 20. JOB SITE VISITS BY THE ENGINEER- DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. "THRESHOLD" 5. SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND STEEL NOTES: STRUCTURAL S E INSPECTIONS AS REQUIRED BY THE LOCAL BUILDING DEPARTMENT SHALL APPLICABLE CODES, LIST THE DESIGN CRITERIA, AND SHOW ALL DETAILS BE UNDER A SEPARATE CONTRACT. AND PLANS NECESSARY FOR PROPER FABRICATION AND INSTALLATION. 1. THE MATERIAL FABRICATION AND ERECTION OF STRUCTURAL STEEL CONCRETE SLAB ON FILL: CALCULATIONS AND SHOP DRAWINGS SHALL IDENTIFY SPECIFIC PRODUCTS SHALL COMPLY WITH THE SPECIFICATIONS FOR THE DESIGN FABRICATION: ' 21. SHOP DRAWINGS ARE AN AID FOR FIELD PLACEMENT AND ARE UTILIZED. GENERIC PRODUCTS WILL NOT BE ACCEPTED. AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, 13TH EDITION,. BY SUPERSEDED BY THE STRUCTURAL DRAWINGS. IT SHALL BE THE A A 1. SELECTED FILL MATERIALS SHALL BE CLEAN CRUSHED LIMESTONE (3 6. SHOP DRAWINGS AND CALCULATIONS REQUIRE THE IMPRESSED SEAL, THE AMERICAN 'CONSTRUCTION. RESPONSIBILITY OF THE GENERAL CONTRACTOR TO MAKE CERTAIN THAT MAXIMUM PARTICLE) OR CLEAN .FINE SAND. THE FILL PLACEMENT SHOULD DATE AND SIGNATURE OF THE SPECIALTY ENGINEER. COMPUTER INSTITUTE OF STEEL ALL CONSTRUCTION IS IN FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWINGS. OCCUR IN THE DRY AND COMPACTED TO A MINIMUM OF 95% OF THE PRINTOUTS ARE AN ACCEPTABLE SUBSTITUTE FOR MANUAL' COMPUTATION 2. STRUCTURAL STEEL SHAPES SHALL CONFORM TO THE 'FOLLOWING. . MODIFIED PROCTOR MAXIMUM DRY DENSITY ASTM D-1557 . FOLLOW SOIL ( ) PROVIDED THEY ARE ACCOMPANIED BY SUFFICIENT DESCRIPTIVE ROLLED SHAPES=----------ASTM A992 22. THE CONTRACTOR SHALL SUPPLY R LL P LY THE: ENGINEER WITH SEPIA LAB RECOMMENDATION FOR THE METHODS AND PROCEDURES. ALL FILL R L LL INFORMATION TO PERMIT THEIR .PROPER EVALUATION. SUCH DESCRIPTIVE. PLATES AND BARS___-_____ ASTM 'A36 COPY AND FOUR BLUE LINE COPIES F SHOP DRAWINGS A MINIM OF WORK SHALL BE SUPERVISED BY A SOIL LAB REPRESENTATIVE. ALL TOP INFORMATION SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE EEL TUBING ASTM A500 GR.B tvt,. TWO WEEKS PRIOR TO PLACEMENT. THE REVIEW OF SHOP DRAWINGS BY SOIL SHALL BE REMOVED BEFORE STARTING FILLING OPERATIONS. SPECIALTY ENGINEER AS AN INDICATION THAT HE HAS ACCEPTED STEEL PIPE - ASTM A53 GR.B D IG DEPT. THE ENGINEER IS ONLY FOR GENERAL COMPLIANCE WITH THE STRUCTURAL RESPONSIBILITY FOR THE RESULTS. SEPIAS DO NOT REQUIRE SIGNATURE ANCHOR BOLTS ASTM A307 RA DRAWINGS AND SPECIFICATIONS. THIS REVIEW DOES NOT GUARANTEE IN 2. SLABS ON GRADE SHALL BE PLACED OVER 6 MIL VISQUEEN OR AND SEAL. THE STRUCTURAL ENGINEER WILL RETAIN ONE SIGNED AND BOLTS- ----- T HIGH STRENGTH BOLTS_______AS M A325 . FC'r+.+RAL CTIOM ANY WAY THAT THE SHOP DRAWINGS ARE CORRECT NOR DOES IT INFER ENGINEER -APPROVED EQUIVALENT. SEALED BLUELINE PRINT FOR RECORDS: THAT THEY SUPERSEDE THE STRUCTURAL DRAWINGS. 3. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE "SHOP. 3. WELDED WIRE FABRIC SHALL CONFORM WITH .ASTM A 185-79 7. DRAWINGS PREPARED SOLELY TO SERVE AS A GUIDE FOR FABRICATION STANDARD SPECIFICATIONS FOR WELDED WIRE FABRIC FOR CONCRETE AND INSTALLATION (SUCH AS REINFORCING STEEL SHOP DRAWINGS OR 4. ANCHOR BOLTS AT COLUMN BASES SHALL BE ASTM A307 BOLTS WITH -1y DESIGN LOADS: REINFORCEMENT. STRUCTURAL STEEL ERECTION DRAWINGS) AND .REQUIRING NO DOUBLE -NUT LEVELING. ALL OTHER BOLTS SHALL BE ASTM A325-N ENGINEERING INPUT DO NOT REQUIRE THE SEAL OF A SPECIALTY BOLTS THE STRUCTURAL FRAMING WAS DESIGNED USING THE FOLLOWING 4. WELDED WIRE FABRIC SHALL BE SUPPORTED ON SLAB BOLSTERS OR ENGINEER. WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL BE Y ;d SUPERIMPOSED LOADS. DESIGN WIND LOADS WERE DETERMINED IN „ CONCRETE BLOCKS SPACED NO FURTHER THAN 3 -O O.C. TIGHTENED ACCORDANCE WITH F.B.0 2,020, 7TH ED. AND -ASCE 7-16. 8. CATALOG INFORMATION ON STANDARD- PRODUCTS -DOES NOT REQUIRE IN ACCORDANCE .WITH THE TURN -OF -THE -NUT METHOD.. z J W III W I� W a r, U M M i W � 0 0 C" co v w 0 CL REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MD AF ROOF: 5. SAW -CUT CONTROL JOINTS SHALL BE SAWED AS SOON AS THE THE SEAL OF A SPECIALTY ENGINEER. CONCRETE IS HARD ENOUGH NOT TO BE WORN OR DAMAGED BY THE 5. WELDING SHALL BE DONE BY AWS CERTIFIED WELDERS USING THE DEAD LOAD 25 PSF BLADE. 9. REVIEW BY THE STRUCTURAL ENGINEER OF RECORD OF SUBMITTALS IS MOST LIVE LOAD 30 PSF LIMITED TO VERIFYING THE FOLLOWING: RECENT AWS APPROVED TECHNIQUES. SHIELDED METAL ARC WELDING , 6. COLUMNS,BEAMS AND WALLS OR ANY OTHER STRUCTURAL MEMBER ( SMAW WIND: PENETRATING SLABS ON FILL SHALL BE ISOLATED BY PREMOLDED JOINT A. THAT THE SPECIFIED STRUCTURAL SUBMITTALS HAVE BEEN FURNISHED. SHALL USE E70XX LOW -HYDROGEN ELECTRODES WIND VELOCITY 175 MPH Kd 0.85 FILLER (1 /2" THICK) COMPLYING WITH ASTM 01752, TYPE 1. DRAWINGS IMPORTANCE FACTOR 1.0 GCPI f 0:18 AND FILLER AND SEALANT MATERIALS SHALL FOLLOW SPECIFICATIONS. B. THAT THE STRUCTURAL SUBMITTALS HAVE BEEN SIGNED .AND SEALED 6. ALL STEEL SHALL RECEIVE SHOP. AND FIELD, TOUCH-UP. COATS OF EXPOSURE CATEGORY D BY THE SPECIALTY ENGINEER. PAINT IN 7. JOINTS SHALL BE SEALED WHERE INDICATED BY THE ARCHITECTURAL. ACCORDANCE WITH SSPC SPECIFICATIONS: C. THAT THE SPECIALTY ENGINEER HAS UNDERSTOOD THE DESIGN INTENT AND HAS USED THE SPECIFIED STRUCTURAL CRITERIA. (NO DETAILED 7. CONTRACTOR OR FABRICATOR SHALL PROVIDE ALL TEMPORARY CHECK OF CALCULATIONS WILL BE MADE.) BRACING NECESSARY TO INSURE A STABLE STRUCTURE JURING CONSTRUCTION. D. THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL SUBMITTALS IS CONSISTENT WITH THE CONTRACT DOCUMENTS. (NO DETAILED CHECK OF DIMENSIONS OR QUANTITIES WILL BE MADE:) 10. SUBMITTALS NOT MEETING THE ABOVE CRITERIA WILL NOT BE Mia ' Dade County Department of Regulatory . and Economic Resources - Job CopY REVIEWED. 0921017036 9/3/2021 1:20:03 PM S-l.pdf ••• • • • • • • • • 1 2 3 4 5 6 7 8 9 EXISTING ASPHALT 1 " PLAN NOTES: WA 8 6 8 8 8 9 6'-11" 25' 2" - • , 1. COORDINATE W/ ARCHITECTURE ALL DLMENSIONS.' ..' :...:. �►� EXIST. OPENING TO BE ADJUSTED 1 � EXIT. CONC. TO NEW WINDOW EXIST. CONC. I 2. GC TO ' VERIFY ALL DOORS AND WINDOWS OPENING COLUMN SEE DETAIL 1 S-4 COLUMN DIMENSIONS PRIOR TO START EREG Z)% OF`*MACRRTt ( / ) (V.F F } (tH F.) — . — —11� — — — — — — — — — — F BLOCK AND THE POURING OF THE ��bT�1�CRET�• SLAB: W/. » EXIST. CONC. EXIST. CONC. EXIST. CONC. ARCHITECTURAL PLANS'`AND MANUFf1CTUIREI?•PRO'DUCi' •�•• CONSULTING ENGINEERS 4'-9 4 -4 7 —3 4 —4 5 —6 i COLUMN COLUMN COLUMN _ I CONTROL REQUIREMENTS. CA # 30228 �' .. ..�" (V.I.F:) (VI.F.) ) — — N 2420 NE Miami Gardens Dr., E — — l— — — — — — E J FROM PORCH I ®ff ° ° ° ° ° ° • ° ° ° • ° ° ®• STE 203 o, �, Miami, FI. �33180 ' 305 5 0 08 161 LEGEND INDICATES EXISTING CONCRETE FOUNDATION TO =REMAIN.' _ INDICATES NEW CONCRETE FOUNDATION. INDICATES EXISTING 8" Digitally. MASONRY WALLS DN: c=U INDICATES NEW 8" CMU REINFORCED • W/1 #5 @32" 'OC MAX. TYPE B dnQualifi 791 cn 0 INDICATES NEW WINDOWS AND - Date: DOORS OPENING. INDICATES EXISTING WINDOWS AND DOORS OPENING. MUST, BE VERIFIED IN FIELD AND (V.I.F.) SHALL BE NOTIFIED TO THE AOR/EOR IN CASE OF ANY DISCREPANCIES WITH THE PLANS PRIOR TO BEGIN ANY WORK EXISTING CONCRETE SLAB TO S@ REMAIN p. e: engineering@eng4build.com w: eng4build.com SEAL: VALID ONLY WITH PE SEAL & SIGN. VALID FOR (1) PERMIT ONLY. igned by Andre Felicia ' E sFo o=engineering Oe p: .build No. 754% r=A01410000 1 ° 83136900000 BC Andres M Fe ciari ,_ •'� AreoF 021.06. = 32:21 '-04'0'/�Q,1�,m Andres M. Feliciano FI Reg P.E. # 75404, SLAB SCHEDULE NEW CONC. I SLAB REINFORCED,, WITH 6"` IX 6"W2.9' X W29 W.W.M. TO BE POURED S1 OVER EXISTING CONCRETE SLAB SEE DETAIL 3/S-4 I � LI 25'-2» 8'-6" 8'-8" 8' -9" 6'-11" 25'-2" 1 9 3 4 5` 7 9 z w O W I� CO 04 W p M U M M Z co LL. W co 0 rn Q C/ C W Q C/:> d_ 4i i= F- U w O d REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL' ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by. MD AF 0921017036 9/3/2021 1:20:03 PM S-2.pdf 25'-2" 8'-6" 6'-11 " 25'-2" - EXISTING ASPHALT DRIVEWAY F — F N c� rn a; N I I N D _ 3 o W . N U z��0� O r L� 'n cam z_ � II XQ�W— I WW�m ST: NC. m EAM 0 B REI ORC AS DE IL 4 -4 I; 25'-2'' 8'-6" 8'-8 8'-9" 6'-11 " 25'-2" IN 0921017036-'9/3/2021 1:20:03 PM r S-3.pdf LEGEND ........... ,. .. _ — INDICATES EXISTING CONCRETE FOUNDATION«Tt7,REM�I�V'; ,'•', ." INDICATES N �(�G�0J1CI ',..' +.. — .T.E • FOUNDATION. INDICATES EXISTING 8" MASONRY WALLS ° INDICATES NEW 8", CMU REINFORCED W/1#5' @32" OC MAX. TYPE B QINDICATES NEW WINDOWS AND DOORS OPENING. INDICATES EXISTING WINDo itally signe AND DOORS OPENING. •c= ,o= MUST BE VERIFIED IN FIELD AND (V.I.F.) SHALL BE NOTIFIED TO TH AOR/EOR IN CASE OF ANqnQualifier=A DISCREPANCIES WITH THE PLAN79158313 PRIOR TO BEGIN ANY WORK cn=Andr A EXISTING CONCRETE SLAB TODate:2021. Se REMAIN .o CONSULTING ENGINEERS CA # 30228' 2420 NE Miami Gardens Dr., STE 203 Miami, FI. 33180 p: 305 508 0161 e: engineering@eng4build.com w: eng4build.com SEAL: VALID ONLY WITH PE SEAL & SIGN. VALID FOR (1) PERMIT ONLY. JI by Andre ®®®,,�a Felicia gineering O, build No. 75404 14100000 9000005 B ATE OF s M Fe is ®® •:,R�uP. �•'��� 6. Y , :34:0 Andres M. Feliciano cD z w 0 co mow�// N W " M V M C! z t9 rn � Q W Cry LZ di _I H H C.� W O REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ; ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL' ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MID AF COLUMN SCHEDULE 00 FC MASONRY CONCRETE 1#5@32" O.C. MAX. (U.O.N.) FILL CELL FOR STEM WALLS SEE SECTIONS 1 #5@24" O.C. MAX. I FILLED HOLE: EXIST. CONC. • ! • 1! : I FOOTING SCHEDULE SIZE REINFORCING MARK TIES NOTES WIDTHxLENGTH HEIGHT BOTTOM TOP WF-16 16" 12" 2#5 CONT. TRANSVERSAL --_ EXIST. CONT. FOOTING EXIST. 5@12" 0 C MAX # I (V.I.F.) _ WF 16 ° 16 12 " 2#5 CONT. ; TRANSVERSAL ___ NEW #5@12" O/C MAX TIE .BEAM • • (V.I.F) �CONSULTING 6 • MESH CA # 30228 EXIST. 2420 NE Miami Gardens Dr., CONC. SLAB NEW CONE. SLAB STE 203_ PER PLAN Miami, FL 33180 p' 305 508 0461 e: engineering@eng4build.com • ter•::,'- >:: EXIw: eng4build.com •�' . `+�;.'_�. - -:,. ST. :::: ;. •.»_. `.4.'.r .r. �?' CONC. SLAB r SEAL \ \ \ \ VALID ONLY WITH FILL WITH 1 #5 VERT. FILL WITH 3000 PSI GROUT 3000 PSI GROUT PE SEAL & SIGN. \\\ \\\\\\\\ j\\\\� VALID FOR (1) PERMIT ONLY. ❑❑ ❑ ❑= Digitally signed by Andre 1 #5 VERT. TOP VIEW Felicia DN: c=US, o=engineering far �0 . .. TOP T.B. W . S B TO EXIST. SLAB CONNECTION DETAIL TYP. _ " `' bU I I d : , No. 75404 EXISTING TIE BEAM N.T.S. dnQualifier=A0141000000. 9 = $ 10 REMAIN 1583B69000005CBC cn=A res DRILL #5 REBAR 6" INTO M Fe lap• °° ATE OF t•��� + U ..BEAM EPDXY ADHESIVE Date:2021.06. 1 :35:25 .. . NEW a '-04'00 w2 / � #5 Andres M. Feliciano b : 12 NEW (TYP.FI Reg P.E. # 75404 .• 1 # 5 FILL CELL 3�2' 3Y2,> 6" ) EXIST. CONC. BEAM 8x12 (V.I.F:) ;. EXISTING WALL, NEW CONC. TO REMAIN COLUMN 8x12 Y - nD III I (`�71 1 C.D z J W O w L Lim/ f N W U co Cq `� u _Z co W C!D ' J U UJ O a- REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project rn,o. 2137 drawn by checked by MD AF WALL OPENING TYPICAL REINFORCED MASONRY DETAIL N.T.S. , N.T.S. DOWELS EXTEND 30" NOTES FROM FOUNDATION 1) PROVIDE #9 GA. LADDER TYPE HORIZON. REINF. AT 16 O.C. MAX. LAP AT WALL INTERSECTION WITH „T" AND „L" CORNER SECTIONS. 2) 8„ CONC. MASONRY BLOCK WALLS W/ REINFORCING AS PER STRUCT. DWG's 3) FOR ADDITIONAL APPLICABLE REINFORCED MANSORY NOTES SEE SHEET- 4) LEGEND: LOAD BEARING REINFOECED MASONRY BLOCK WALL CLEANOUTS TO BE SEALED AFTER INSPECTION REQUIRED AT ALL CELLS IF POURED IN LIFTS EXCEEDING 2' — 0" REINFORCED MASONRY DETAIL (TYP.) CMU WALL REINFORCING DETAIL (TYP.) N.T.S.; N.T.S. Miam' Dade County Department of Regulatory and Economic Resources Job Copy 0921017036 - 9/3/2021 1:20:03 PM S-4.P df _ UNDER SEPARATE PERMIT (BY OTHERS) PE SEAL & SIGN. VALID FOR (1) PERMIT ONLY. "ttttt�� Digitally signed by Andre M M. F a l t) Felicia b. .s"�ceNs4/�'G.���. I7nNF 4 7nNF 4 7MIF 4 z Lu O w H N co Ir W -_ M U m M CO J u � 1 � � Q ��Cn v J � L 1 J Q v ) W t-- f= H U W O D_ REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MD AF 0921017036 - 9/3/2021 1:20:03 PM S-S.pdf ELECTRICAL GENERAL NOTES: (Not all notes are applicable) 1. PROVIDE ALL FINAL CONNECTIONS TO ALL EQUIPMENT AND APPLIANCES. 2. PROVIDE ALL A/C CONTROL AS REQUIRED BY A/C DRAWINGS OR MANUFACTURER DIAGRAMS. 3. ALL LAVATORIES AND KITCHEN RECEPTACLES SHALL BE GFCI TYPE.' 4. TERRACE RECEPTACLES TO BE GFCI AND WEATHER PROOF. 5. COORDINATE LOCATION OF ALL DISCONNECT SWITCHES WITH OTHER TRADES TO ALLOW N.E.C. REQUIREMENT CLEARANCE. 6. CIRCUITS WIRING REQUIRED TO BE AS FOLLOWS: 120V-2 WIRE (L-N); 120/240V - 3 WIRE )LL-N); 240V-2 WIRE (LL). WHEN EQUIPMENT GROUND IS REQUIRED INCREASE CONDUIT SIZE AS REQUIRED. 7. ALL WIRING TO BE COPPER. THHN/THWN TYPE RUN IN CONDUIT. (METALLIC TYPE EMT). ROMEX IS ACCEPTABLE WHERE PERMITTED BY LOCAL CODE AND ACCEPTABLE TO OWNER. 8. COORDINATE LOCATION OF AIR CONDITIONER (INDOOR UNIT) DISCONNECT SWITCH WITH A/C CONTRACTOR TO KEEP N.E.C. REQUIRED CLEARANCE. 9. MINIMUM WIRE SIZE SHALL BE #12 WITH THE EXCEPTION OF 15A GENERAL LTG. AND RECEPTACLE BRANCH CIRCUITS WHICH ARE #14. 10. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. 11. CONDUIT IN UNFINISHED AREAS SHALL ,BE EXPOSED. 12. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TIME. 13. INSTALL NYLON PULL STRING IN ALL EMPTY CONDUITSFOR FUTURE USE. 14. ALL MATERIALS SHALL BE U.L. APPROVED. 15. WORKMANSHIP SHALL BE TO BEST COMMERCIAL PRACTICE. 16. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LATEST EDITION (NEC 2017) AND THE LATEST EDITIONS OF ALL LOCAL CODES, (FLORIDA BUILDING CODE 2020,' 7TH ED.) RULES, AND ORDINANCES HAVING JURISDICTION. 17. RECESSED LIGHT FIXTURES OVER BATHTUB OR SHOWER SHALL BE COMPLETELY ENCLOSED AND VAPOR PROOF SUITABLE FOR WET LOCATIONS. 18. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. 19. RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 20. THIS DRAWINGS IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 21. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING; BREAKER`, AND _FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 22. CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. ELECTRICAL SYMBOLS LEGEND: SYMBOL DESCRIPTION $ SINGLE POLE TOGGLE SWITCH 2OA, 120V MOUNTED 48" A.F.F. s 3-WAY TOGGLE SWITCH 2OA, 120V MOUNTED 48" A.F.F. DUPLEX RECEPTACLE WALL MOUNTED (Tamper Resistant) DUPLEX RECEPTACLE FLOOR/CEILING MOUNTED DUPLEX RECEPTACLE WITH GROUND Ge' FAULT INTERRUPTING DEVICE DUPLEX SPECIAL PURPOSE OUTLET TELEVISION/COAXIAL CABLE OUTLET E L[:] [�-.M ELECTRICAL METER/DISCONNECTIVE/PANEL O RECESSED LIGHT FIXTURES V.P. VAPOR PROOF. ® SMOKE DETECTORS OUTSIDE THE SLEEPING QUARTERS SHALL BE A CARBON MONOXIDE / SMOKE DETECTOR COMBO AND ALL SMOKE DETECTORS SHALL BE 110 V, INTERCONNECTED WITH BATTERY BACK-UP. ALL SMOKE DETECTORS SHALL BE MOUNTED 3'-0" AWAY FROM A/C DIFFUSER & 4" TO 12" BELOW CEILING ON WALL. TAMPER -RESISTANT RECEPTACLES AS PER NEC 406.12 TAMPER -RESISTANT RECEPTACLES IN DWELLING UNITS. ALL NONLOCKING TYPE 15A AND 20A, 125V RECEPTACLES IN THE FOLLOWING AREAS OF A DWELLING UNIT [210.52] MUST BE LISTED AS TAMPER -RESISTANT. • WALL SPACE - 210.52(A) • SMALL -APPLIANCE CIRCUIT - 210.52(8) • COUNTERTOP SPACE 210.52(C) • BATHROOM AREA - 210.52(D) • OUTDOORS - 210.52(E) • LAUNDRY AREA - 210.52(F) • GARAGE AND OUTBUILDINGS 210.52(G) • HALLWAYS - 210.52(H) EX: RECEPTACLES IN THE FOLLOWING LOCATIONS AREN'T REQUIRED TO BE TAMPER -RESISTANT: (1) RECEPTACLES LOCATED MORE THAN 5% FT ABOVE THE FLOOR. (2) RECEPTACLES THAT ARE PART OF A LUMINAIRE OR APPLIANCE. (3) A RECEPTACLE LOCATED WITHIN DEDICATED SPACE FOR AN APPLIANCE THAT IN NORMAL USE ISN'T EASILY MOVED FROM ONE PLACE TO ANOTHER: (4) NONGROUNDING RECEPTACLES USED FOR REPLACEMENTS AS AND RACEWAYS, ALL POWER CONTROL CIRCUITS WIRING AND PERMITTED IN 406.4(D)(2)(A). RACEWAYS AS SHOWN ON THE AIR CONDITIONING DRAWINGS REFER TO MANUFACTURER'S WIRING DIAGRAMS, THE CONTRACTOR SHALL VERIFY WITH SAID MANUFACTURER ALL REQUIREMENTS AND INCLUDE ALL ARC FAULT CIRCUIT -INTERRUPTER PROTECTION RELATED WORK IN HIS CONTRACT. AS PER 210.12 NEC 2017 b EX. EX. EX. R EX EX EX AFCl/GFCI R EX EX EX EX. AFCl/GFCI N EX. R AFCl/GFCI N TYPE: SQUARE 'D' (OR APPVD EQUAL) "EXIST. TO BE RELOCATED PANEL A" MAIN BUS: 200A SERVICE: RESIDENCE NEUTRAL: 200A VOLTAGE: 240/120v 1PH. 3W. MAIN: LUGS ONLY AIC: 22K (ALL 20 AMPS, 1 POLE CKTS. EXCEPT AS NOTED) LOCATION: AS SHOWN °- a u� J o a a Q ~o I- > z w o N U N W w Of N REMARKS 6 z Y U 6 z Y c� REMARKS ww �N N Z W o N 0 <n Q a ~o �> to J o a a g a 60 2 12,000 3/4 6 A/C AHU #1(**) 1 2 OVEN EX. EX. 6,000 2 40 60 3 4 40 20 1 1,200 EX. EX. WINE COOLER 5 6 COOKTOP EX. EX. 6,000 2 40 20 1 1,500 1/2 12 BATH REC. GFI 7 8 40 30 2 5,000 EX. EX. W.H 9 10 SPRINKLER IRRIGATION EX. EX. 1,600 1 20 30 11 12 SPRINKLER IRRIGATION EX. EX. 1,600 1 20 30 2 5,000 3/4 8 DRYER 13 14 ENTRANCE/ BED3 LIGHTS EX. EX. * 1 15 30 15 16 GENERAL LIGHTS EX. EX. * 1 15 20 1 * EX. EX. KITCHEN /LAUNDRY LIGHT 17 18 GENERAL LIGHTS EX. EX. * 1 15 20 1 1,500 EX. EX. SMALL APP. 19 20 DINNING REC. EX. EX. * 1 20 20 1 1,500 EX. EX. SMALL APP. 21 22 HOOD EX. EX. 800 1 20 20 1 1,500 1/2 12 WASHER 2 24 BBQ GFCI 12 1/2 1,500 1 20 - - - - - SPARE T5 26 MASTER BATH LIGHTS & REC 12 1/2 1,500 1 1 20 20 1 1,500 EX. EX. DISHWASHER T/ 28 REFRIGERATOR EX. EX. 1,500 1 20 20 1 600 EX. EX. DISPOSAL 29 30 BATH2 LIGHTS & REC. GFI EX. EX. 1,500 1 15 20 1 * EX. EX. MASTER BED LIGHTS 31 32 FAMILY LIGHTS EX. EX. * 1 15 20 1 1,500 1/2 12 LAUNDRY REC. GFCI 3 34 DINNING LIGHTS EX. EX. * 1 15 20 1 * EX. EX. LIVING LIGHTS 3 36 HALLWAY 12 1/2 * 1 20 60 2 12,000 3/4 6 C.U. #1 3 38 BEDROOM LIGHTS & REC. 12 1/2 * 1 20 60 1 1 39 40 BEDROOM LIGHTS & REC. 12 1/2 * 1 20 20 1 1 1,500 1/2 112 1 BATH LIGHTS & REC. GFI 41 42 FRIDGE 12 1/2 1,500 1 20 CONNECTED LOAD: SEE CALCULATIONS FED FROM: SERVICE * PART OF THE 3 W/SQ , FT (**) PROVIDE HACR TYPE OF BREAKER FIELD IDENTIFICATION REQUIRED NOTE: CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE POSITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES OR SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A PANELBOARD, AND LOCATED AT EACH SWITCH OR CIRCUIT BREAKER IN A SWITCHBOARD. NO CIRCUIT SHALL BE DESCRIBED IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF OCCUPANCY. NOTE: CONTRACTOR MUST VERIFY ALL EXISTING INFORMATION AND HE MUST NOTIFY THE A.O.R./E.O.R. OF ANY DISCREPANCIES BETWEEN THE FIELD AND PLANS. NOTE: ALL NEW CIRCUITS SHALL BE ARC FAULT PROTECTED AND ALL RECEPTACLES SHALL BE TAMPER RESISTANT. 23. ALL DEVICES, PANELS, OUTLETS, SWITCHES, ETC. TO BE MOUNTED 210.12 ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION. ARC FAULT ABOVE FLOOD CRITERIA. CIRCUIT -INTERRUPTER PROTECTION SHALL BE PROVIDED AS 24. ALL 15 AND 20 AMP, 120 VOLT RECEPTACLES OUTLETS MUST BE REQUIRED IN 210.12(A) (B), AND (E). THE ARC -FAULT CIRCUIT NOTE LIGHTING: LISTED TAMPER RESISTANT PER N.E.C. 2017 (406.12). INTERRUPTER SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. LIGHTING IN THERMAL ENVELOPE SHALL BE 25. REFRIGERATOR RECEPTACLE TO BE MOUNTED +48" A.F.F. (A) DWELLING UNITS. ALL 120-VOLT, SINGLE-PHASE, 15 AND 20 IC RATED AND MEETING ASTM E 283 FOR AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES LEAKAGE LABELED "AIR TIGHT" AND INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING HOUSING SHALL BE A GASKET OR CAULK ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, TO CEILING OR WALL. R402.4 SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN 210.12(A)(1) THROUGH (6) NEC2017. (B) BRANCH CIRCUIT EXTENSIONS OR MODIFICATIONS DWELLING UNITS. IN ANY OF THE AREAS SPECIFIED IN 210.12(A), WHERE BRANCH -CIRCUIT WIRING IS MODIFIED, REPLACED, OR EXTENDED, THE BRANCH CIRCUIT SHALL BE PROTECTED BY ONE OF THE FOLLOWING: HOME HERO SMOKE DETECTOR -. -KITCHEN OR BATHROOM LIGHT 120 V NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SMOKE DETECTOR SHALL NOT BE PLACED SUBSCRIPT LEYEND WITHIN 3FT. OF ANY A/C GRILL E -EXISTING TO REMAIN SWITCH LEG LINE SIDE OF SWITCH R - EXISTING TO RELOCATE SWITCH PHASE CONDUCTOR RPL - EXISTING TO REPLACE N - NEW NOTES: (V.I.F.) - EXISTING INFORMATION MUST BE VERIFY IN FIELD BY ELECTRICAL CONTRACTOR. IN CASE OF ANY DISCREPANCIES 1.- ALL SMOKE DETECTORS MUST HAVE BATTERY BETWEEN FIELD AND THIS PLANS MUST BE NOTIFIED TO THE BACK-UP AND BE INTERCONNECTED, - FOR PRIOR TO START .ANY WORKS. 2.- ALL SMOKE DETECTORS TO BE FED FROM BATH OR KITCHEN LIGHTING CIRCUITS, AHEAD OF ALL SWITCHES, 3.- ALL BEDROOM RECEPTACLES OUTLETS SHALL BE CONNECTED TO AN ARC FAULT INTERRUPTER C.B. SMOKE DETECTOR CONNECTION DETAIL (TYP.) N.T.S. ELECTRICAL LOAD CALCULATIONS ITEM WATTS SQ. FT 2,6161 GENERAL LIGHTING (3W/S.F.) 71848 SMALL APPLIANCES 3,0.00 COOKTOP 6,000 REFRIGERATOR 1,500 WATER HEATER 5,000 DISPOSAL 600 DISHWASHER 1,500 DRYER 5,000 WASHER 1,500 FRIDGE 1,500 EXTERIOR LIGHTS & RECEPT 1,500 HOOD 800 OVEN 6,000 WINE COOLER 1,200 SPRI NKLER I RRI GATI ON 3,200 LAUNDRY GFCI 1,500 BATH GFCI 31000 CONNECTED LOAD: (LESS A/C) 507648 FIRST 10KW @ 100% 10,000 BAL. a}40%o 167259 A/C OR HTG. @ 100% 121000 DEMAND LOAD: 38,259 AMPS @ 240/120V. 1 PH 159 BREAKER SIZE 200 3-3/0 THWN 2" - • #4 GRND (CU) EXIST. C 0010,000 AIC CONSULTING ENGINEERS EX. FPL METER COMBO • • MAIN 250 AMP .... ..... ... ..•. 120 24OV, 1PH, 3W EXIST. Miami Gardens Dr.; EX. (V.I.F.) 2 EXIST. 200� REPANELLOCATED Miami, FI. 33180 EX. I ,A, p: 305 508 0161 nn 2 I e: engineering@eng4build.com EX. I V I 50� w: eng4build.com EX. I E TO T. 200A EX. TO SEAL: EX. UNTOUCHED VALID ONLY WITH EX. EXIST. Ex. POOL PANEL PE SEAL & SIGN. EX. EXIST.. �P, VALID FOR (1) PERMIT ONLY. N GFCI 1 #2 THWN-1" 5ll�i it Ily signed by Andres' a®,® N GND. Felicia AFCl/GFCI $ M..FF< / EX. DN: c=US, o=engineering r °° ucENSF° b% ° EXIST. build �": r No.75404 EX.EXIST. (V.I.F:) 3-250 KCMIL` CU 2 1/2" - CONNECT TO TWO -5 8" x10' GROUNDING ROd9 ffL�=A01410000000 9 * ; EX. / e TO FPL SERVICE POINT 6' BOND TO A 3/4" COPPER WATER PIPE STUB -OUT 1583B6900000 BC,' kl Ex. AT METER LOCATION &' ENCASED GROUND: SEE . DET ATE OF N AFCI... (V.I.F.) ��r-Andres M Fe ia �i 4� iJRID ,. N AFCI :37 i ,�+/ •-..... SEE ` ARCHITECTURA P ANb '00 N AFCI FOR THE EXACT L ION. N AFCl/GFCI Andres M. Feliciano FI Reg P.E. # 75404 ELECTRIC RISER DIAGRAM SCALE: N.T.S. Z J L_U L� G� �W/ IrY� H N LJ_1I 72 M U M M 7 U- w � � I� r= U w 0 CLCD REVISION No. DATE THESE PLANS ARE FORBUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT. APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MID AF L Dade County Department of Regulatory and Economic Resources Job Copy )17036 9/3/2021 1:20:03 PM 4f 70VEN I •. • i • •• •• • • • V096 • • • • • • • • • • • ; ; CONSULTING ENGINEERS CA # 30228 2420 NE Miami Gardens Dr., STE 203 Miami, Fl. 33180 p: 305 508 0161 e: engineering@eng4build.com w: eng4build.com SEAL: VALID ONLY WITH PE SEAL & SIGN. �- VALID FOR (1) PERMIT ONLY. Digitally signed by Andre ®giERIM Felicia GEN3F `•' DN: c=US, o=engineering r buildt No. 75a04 O dnQualifier=A01410C0000 91583136900000 BC, '• cn=Andres M Fe ATE OF '*LORIDP:�'' Date: 2021.06. :19:00 'a/.��1�s '-04'00 Andres Feliciano FI Reg P.E. # 75404 a Z11 C-D z w 0 O w F-! 72 M M - 1L w O Q CA> mow/ W _I F- H U W O d REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by. MD AF 0921017036 - 9/3/2021 1:20:03 PM E-2 Pdf • e . ee .see. • • • • • • eeee• MA CULL MECHANICAL GE NERAL NOTES. (Not all notes are applicable) 1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED. 2. DIMENSIONS SHALL BE FIELD -VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED :DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR V FIRE DAMPER(S) {/ SMOKE DAMPER(S) V FIRE RATED ENCLOSURE FIRE RATED ROOF/ FLOOR CEILING ASSEMBLY V FIRESTOPPING V SMOKE CONTROL V HANGER STRAPS ... ... ..... • 60"MAX .. UNLESS EC:01 OF- STf 4) •IS ~� PLACE( CJNd;R A.9Q•TTOM :...:. r REINFO[�CE�It:NT SUPPLY AIR RETURN DUCT. DUCT DIRECTLY e . . ! • 1 LOW VELOCITY RETURN AIR TO AHU CONSULTING ENGINEERS >< 0000 0 00*00 0 DUCT (SEE PLAN VIEW) CA # 30228 SCREW "'I MIN 2420 NE Miami Gardens Dr., SCREW MAY BE OMITTED STE 203 ADDITIONAL COST FOR PROJECTS INVOLVING RENOVATION, COORDINATE Miami, FI. 33180 SPIN COLLAR FITTING WITH EXTRACTOR IF HANGER LOOPS . NEW WORK WITH _EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE it STRUCTURE p. 305 508 0161 AND ARCHITECTURAL FEATURES SPRINKLER PIPING LIGHTS PLUMBING OTES: & MANUAL VOLUME DAMPER e: en i508 0 en 4build.com DRYWALL FIN. g g@ 9 AND ELECTRICAL CONDUIT. RIGID DUCT HANGERS(TYP) W: eng4bulld.com A/C DESIGN AS PER DADE COUNTY CHAPTER 8. ) AIR FLOW WOOD PARTITION N.T.S. DUCT CONNECTION SHALL BE AT THE W/ 1/2 DRYWALL GRASSED AREA SEAL: . TOP OR SIDE OF PLENUM AS SPACE FLEX. CONNECTION VALID ONLY WITH CONDITIONS PERMIT. INSULATED FLEX. DUCT PE SEAL & SIGN. SEAL JOINT WITH DUCT AIR HANDLING UNIT IIIIII= °° o °o IIIII=�� ���� `O O: o - VALID FOR (1).PERMIT ONLY. SEALER & TAPE = a = w o o Digitally signed b Andre ' r, REFRIGERANT 9 Y 9 Y ®® 0 ° s M• FF j NOTE Felicia a.•ao° .�/ ®� LINES o° ° ,> ,, �.. - 2 CONDENSATE ATE o 0 24 DIA Q'6 C S •. • INSULATED. PLENUM PROVIDE SAFETY FLOAT S � ° . c�US, o=en Ineerm 4• 4be � F °°• 9 9 <�q SWITCH DEVICE DRAIN LINE ° REINFOR II ° bu d No. 75404 CONDENSATE DRAIN �°eeo � ° CONCRETE PIPE _ o do ualifier=A01410C0000 W/TRAP 3/4"-1 1 /2" PVC o Q 10 DIA. CONC. OR O 91583B6900000 BC x •° .CEILING DIFFUSER FINISH NEOPRENE PADS CLAY PIPE WITHOUT - . ATE OF FLOOR VIBRATION ISOLATOR COVER FILLED W/ . cn-Andres M Fed Iar `� .•.� ROCK Date: 2021.06. 1' :28:47 . ;toD. y.. ,. 3/4 MAXIMUM LENGTH OF FLEXIBLE -DUCT � RUNOUT TO DIFFUSER TO BE 10 FEET '-04'0u��d e 1 "X1 "X4" STEEL ANGLE F AM ATTACH Andres M. Feliciano R E ATTACHED TO REOIBLE DUCT CONNECTION DETAIL(TYP.) FLOOR STRUCTURE CONDENSATE DRAIN DRY WELL DETAIL TYP Fl Reg P.E. # 75404 N.T.S. AHU MOUNTINGN .TS: DETAIL (TYP.) N.T.S. PROVIDE A VIBRATION -FREE RIGID INSTALLATION J. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT CONSTRUCTION STANDARD. 4. SEE SPECIFICATIONS FOR GAUGES, THICKNESS, BRACING, REQUIREMENTS, ETC., OF DUCTWORK. 5. PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS. 6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT FURNISHED. 7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND EQUIPMENT OF ALL TRADES. 8 LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS. 9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO 10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS 11. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE PAINTED FLAT BLACK. 12. REFER TO TYPICAL" DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT. INSULATION NOTES FOR GARAGE AREA: - CEILING INSULATION MUST BE R-30 OR HIGHER. ROOF SPRAYED INSULATION SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY AN APPROVED THERMAL BARRIER OF MINIMUM 1/2- GYPSUM WALLBOARD. - WALL INSULATION MUST BE R-5 OR HIGHER. A/C NOTE: -A/C MUST HAVE PROGRAMMABLE THERMOSTAT -DUCTWORK INSULATION R-6 A/C STATIC PRESSURE 1.25" S.P. WATER GAUGE 1 8" STEE WIRE VCIV l LIIVC VV/ C.O. PLUG SUr I IUbINU PERFORATED CAP CONDENSING 13. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT (SCREWED) CONCRETE SLAB SHALL BE PROVIDED FOR PROPER DRAINAGE TO SUIT EQUIPMENT 4" DRYER VENT 4 Dia. POWER & FURNISHED. TO GA. GALV. A.H.U. BEAM ELEV. o LOCATION EXTERIOR TOP OF THE CONTROL, n a 24 14. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED O a a .a. WHERE` REQUIRED FOR OPERATION, BALANCING OR MAINTENANCE OF ALL SEE ARCH. a MECHANICAL EQUIPMENT. TYP STUD 1 /2" „ PLANS WALL DETAIL TP: BD 5 PITCH DOWN TOWARD DRAIN TSP + 1" 15. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL _ _ 24' CL. TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW DETAIL BOX HOOD DRAIN SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO FULL DRYER VENT DETAIL TERMINATION PAN REFRIGERANT LINES UP SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT. TSP + 1" LIQUID LINE THRU CONCRETE SLAB. DRYER EXHAUST (4" MIN.) W/ o PVC CONDUIT -RUN UNDER SLAB 16. PROVIDE CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR -MOUNTED DRYER EXHAUST SHALL BE CONSTRUCTED OF A MIN. INSULATION SEE FLOOR PLAN FOR LOCATION. EQUIPMENT. REFER TO SPECIFICATIONS FOR DETAILED REQUIREMENTS. - 24-GA. SHEET METAL, HAVING A SMOOTH INTERIOR CONNECTION SURFACE. WITH JOINS RUNNING IN THE DIRECTION OF (SCH. 40' W/SOLVENT WELD JOINTS.) 17. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, AIR FLOW. DUCT JOINTS SHALL NOT BE ASSEMBLED ROUTE PIPING TO EXTERIOR AND 1/2 BOLTS & .NUTS SUCTION LINE USE 4" OR 6" CONDUIT AS REQUIRED. REGISTERS, DIFFUSERS, LOUVERS AND OTHER AIR DISTRIBUTION DEVICES. WITH SHEET METAL _SCREWS OR OTHER FASTENED GOOSENECK MIN. 6" ABOVE ALUMINUM STAND W/ 1/2 ARMAFLEX WHICH WOULD- EXTEND INTO THE DUCT FINISH GRADE. N.O.A. 20-1013.03 INSULATION & VAPOR BARRIER NOTES: 18. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK 1. CONCEALED OR NON _REMOVABLE JOINTS SHALL NOT PROVIDE EXHAUST .DUCT WITH BACK DRAFT DAMPER NOTE: CONNECTING TO EACH FAN, AIR HANDLING UNITS, AND FAN COIL UNITS. BE INSTALLED BELOW THE SLAB. AND WEATHER CAP. MECHANICAL CONTRACTOR WILL COORDINATE WITH PLUMBING 2 P.V.C. SCH. 40 `SLEEVE SHALL BE 2" LARGER THAN CONTRACTOR CONDENSATE SYSTEM INSTALLATION TO BE NOTE: 19. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH ( THE PIPE INSULATION ENCASED, HAVING AN ANGLE SECURE CU W/ ONE 500 LBS ANTI -THEFT BOLTS WITHIN THE UNIT. CASING SIZES OF FLEX DUCTS TO BE CONNECTED. PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR). NO GREATER THAN 45 DEGREES' WITH THE ENCASED THROUGH THE BASE PLATE. (MDC- CH. 8C-5) REFRIGERANT PIPING. REMOVABLE FOR REPLACEMENT. 20. ALL EQUIPMENT, DUCTWORK, ETC., TO BE REMOVED SHALL REMAIN PROPERTY OF THE OWNER OR DISPOSED OF LEGALLY, AS DIRECTED BY DRYER EXHAUST ) CONDENSATE DRAIN TRAP DETAIL (TYP) C.U. MOUNTING DETAIL (TYP.) REFRIGERANT LINE CONDUIT DETAIL (TYP.) OWNER. N.T.S. N.T.S. N.T.S. N.T.S. 21. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS. GALV. EXHAUST NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT 22 LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 10'-0" CLEAR ROOF CAP MAX. 5 FT. SPACING FROM ALL PLUMBING VENTS AND EXHAUST AIR DISCHARGE LOCATIONS. BETWEEN SUPPORTS LOWEST POINT OF EACH OUTSIDE AIR INTAKE 'ON ROOF SHALL BE A PROVIDE MINIMUM OF 24" ABOVE ROOF. BIRD OCREERESISTANT 1-1/2" GALV. x 22 Ga. METAL STRAPS. 23. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE �oZ DIFFUSER NECK. ROOF TILE OR ROOF SHINGLE - - LOW VELOCITY 24. WATER PRESSURE OROPS THROUGH COIL CONTROL VALVES SHALL BACK DRAFT _ _ FLEXIBLE DUCT - NOT EXCEED 5 PSI. DAMPER - - - 2' X 4,. 25. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS BLK'G. 1 2" PER FT. SHALL BE INDEPENDENTLY ,PIPED FULL SIZE TO THE NEAREST PLUMBING / DRAIN. 4» d (30 GA.) SMOOTH MTL. DUCT MAXIMUM SAG. FROM KITCHEN HOOD EXHAUST FAN (2.5" FOR 5 FT. SPACING) 26. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS. PROVIDE MANUAL AIR VENTS AT ALL HIGH POINTS IN CHILLED WATER AND HOT WATER PIPING. EXHAUST ROOF CAP DETAIL (TYP.) FLEXIBLE DUCT HANGING DETAIL (TYP.) BATHROOM EXHAUST FAN N.T.S. N.T.S. _AIR HANDLED UNIT UNIT MARK AREA SERVED LOCATION -MFR. AIR HANDLED MODEL TOTAL AIR CFM/TONS BTUH HEATER ELECTRICAL DATA DIMENSIONS SERV. VALVE TOTAL SENSIBLE MODEL CAPACITY SERVICE FUSES H W D LIQ• SUCT. AHU-1 ALL HOUSE A/C CLOSET GOODMAN AVPTC61D14CA 2000/5.0 56,000 38,200 HKSX10XCAA 10 KW 208-240/1/60 60 AMP .. 49" 23" 22" 3/8 7/8" - REFER TO UNIT NAMEPLATE AND/OR DATA FOR MANUFACTURE SPECIFICATION FOR ELECTRICAL INSTALLATION (UNDER ELECTRICAL CONTRACTOR RESPONSIBILITY). ALL THERMOSTATS SHALL BE PROGRAMMABLE. - ALL FAN COIL UNITS SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. CONDENSING UNIT UNIT MARK MFR. COMPRESSOR MODEL BTUH NOMINAL ELECTRICAL DATA TEMP. ENT. CONDENSER SEER SERVICE FUSES CU-1 GOODMAN GSXC180601AA 56,000 208-230/1/60' 60 AMP 95 18 REFER TO UNIT NAMEPLATE AND/OR DATA FOR MANUFACTURE SPECIFICATION FOR ELECTRICAL INSTALLATION (UNDER ELECTRICAL CONTRACTOR RESPONSIBILITY). FAN SCHEDULE FAN # MANUFACTURER AND MODEL NO. MOTOR CFM ELECT. SERVICE WATTS REMARKS EF#1 80 EXISTING TO REMAIN EF#2 FANTECH FR110 0.72 AMPS 100 62-80 NEW, REFER TO PLAN Z J _W W Lij `! co LL w N 0 CD W va J c.� w 0 CL REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. - 2137 drawn by checked by MD AF 0921017036 9/3/2021 1:20:03 PM M- l . pdf • .` • • •, • • CA # 30228 2420 NE Miami Gardens Dr., STE 203 Miami, FI. 33180 p: 305 508 0161 e: engineering@eng4build.com w: eng4build.com SEAL: VALID ONLY WITH PE SEAL &SIGN. VALID FOR 1 PERMIT ONLY. Digitally signed by Andre M `. `jo aF Felicia. .� ,,��•• ,.EN DN: c=US, o=engineering f ? build :� No. 76404 .O = � dnQualifier=A01410C00000 91 583B69000005CBC, cn= dr srAreoF M ciano �i� �%!�`0R%QP9'*G���® .........., 'Date:2021.06.1109= -04'00 ������� N��af��®® Andres M. Feliciano FI Reg P.E.-# 75404 NOTE: PROVIDE 1 DOOR 'UNDERCUT IN ALL BEDROOMS TO ACHIEVE PROPER BALANCED AIR 'RETURN. NOTE: ALL ELECTRICAL, MECHANICAL AND PLUMBING EQUIPMENT MUST BE; ABOVE BASE FLOOD ELEVATION. COORDINATE WITH ARCHITECTURAL PLANS TO SEE THE BASE FLOOD ELEVATION. NOTE: PROVISIONS' MUST BE TAKEN TO PREVENT DUCT SURFACE CONTACT WITH THE FOAM INSULATION; EITHER DURING APPLICATION OR AFTER THE -FOAM IS DRIED UP TO PREVENT A VOIDED LISTING OF THE DUCTS (BOTH FLEX AND FIBERGLASS DUCT BOARD). NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. SUBSCRIPT LEYEND E EXISTING TO REMAIN R - EXISTING TO RELOCATE RPL - EXISTING TO REPLACE N - NEW PLAN NOTES: ' 1 SET OF REF. PIPING. SEE SPLIT A/C UNIT SCHEDULE E OO FOR SIZES (TYP.) f i TOILET EXHAUST DUCT TO WALL CAP W/ CORROSION O RESISTANT SCREEN. AS. PER FBC 401.5 2020. BATHROOM & KITCHEN EXHAUST DUCT SHALL GO THRU O3 ROOF/WALL AND TERMINATE 6" MIN. ABOVE ROOF SURFACE. PROVIDE A BACKDRAFT DAMPER, WITH A CORROSION RESISTANT SCREEN. AS PER FBC R-1506.3, STI P L R303.5.2 AND R303.6. MATERIAL HAVING A MESH NOT LARGER THAN 1/2", AND BE :FITTED WITH A WEATHER CAP. EXHAUST DUCT SHALL "TERMINATE ON THE OUTSIDE 3 FT AWAY FROM ANY BLDG OPENING. GC MUST VERIFIED THIS REQUIREMENT BEFORE START';ANY INSTALLATION. O TERMINATE 2" A/C COND. DRAIN WITH A MINIMUM HORIZONTAL SLOPE, IN THE DIRECTION OF DISCHARGE OF NOT LESS THAN 1'/87 UNIT VERTICAL IN 12. UNITS HORIZONTAL TO OUTSIDE 6 A.F.G.' DRAIN TO BE 12" - AWAY Fpnm nt lTgInF WAI I 4FF nFTAII ON M-1 N C-D _z J W ID W N W1 -e U Cl) M Z L W � 0 0 rn C/: to W w W O ty- CL REVISION No. DATE THESE PLANS ARE FOR BUILDING. DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION' DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021. project no. 2137 drawn by checked by MD AF )17036 - 9/3/2021 1:20:03 PM -- )df GENLNAL PLUMBING NULLS (Nat all notes are applicable) 1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2020, 7TH ED. STATE AND LOCAL ORDINANCES. 2. BUILDING DRAINAGE SYSTEM TO BE SLOPED AT 1 /8" PER FT MIN. FALL FOR 3" PIPE AND LARGER 1 /4" PER FT SLOPE FOR 2" PIPE SIZE AND SMALLER DEVIATIONS SHALL BE APPROVED BY ARCHITECT/ENGINEER. 3. PROVIDE CLEAN OUTS EVERY 75 FT AND AT BASE OF EVERY WASTE STACK. 4. MATERIALS SHALL BE, ALL NEW AND AS FOLLOWS: A. DRAINAGE WASTE AND PIPING (DWV) CONFORMING TO ASTM D-2665, UNDERGROUND NO HUB CAST IRON CISPI STANDARD 301 PRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN ITS APPROVED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR RETURN PLENUM. B. WATER PIPING: COPPER TYPE "L" ASTM B-88 ABOVE GROUND AND COPPER TYPE "K" ASTM B-88 UNDERGROUND. C. CONDENSATE DRAIN PIPING: COPPER TYPE "M" ASTM B-88 INSIDE THE BUILDING AND PVC SCHEDULE 40 ABOVE ROOF AND UNDERGROUND. PROVIDE 3/4" ARMAFLEX PIPE INSULATION TO ALL CONDENSATE DRAIN PIPING. D. GAS PIPING: BLACK STEEL SCHEDULE 40 ASTM-53. E. FLOOR CLEAN OUTS: JOSAM SERIES 56020 OR EQUAL. F. WALL CLEAN OUTS: JOSAM SERIES 58750 WITH ACCESS COVER OR EQUAL G VALVES: 125 PSI NIBCO SCOTT STOCKHAM OR EQUAL TYPE EEAE0 .-- SHOCK STOPS SSE PLAN SHOWER/BATHTUB NOTE: ABOVE CEILING•..• ;'; F.0I �(3NTIN: ' oo •' 0 go SHOWER/BATHTUB COMPARTMENT MUST HAVE FLOOR •• ••• ••� AND WALLS CONSTRUCTED OF SMOUTH, CORROSION 3" VENT RESISTANT AND NONABSORBENT WATER RESISTANT TURN HEAD PIPE WASHER SUPPLY :•••:004• ••••• " MATERIALS TO A HEIGHT OF NOT LESS THAN 72" DOWN INTO STACK & DRAIN GREY BOX • ABOVE THE COMPARTMENT FLOOR AT THE DRAIN • LEAD COVER CONSULTING ENGINEERS .. PER F.B.C.2020 R307 ... ..... .... CA # 30228 2420 NE Miami Gardens Dr., 15"MIN. 30"MIN.15"MIN. STE 203 - Miami, FI. 33180 p: 305 508 0161 engineering@eng4build.com j w: eng4build.com o- - SEAL: VALID ONLY WITH SOLDERED LAP SEAM cv PE SEAL & SIGN. z MEMBER FLASHING 2" O C.O. ACCESS VALID FOR (1) PERMIT ONLY. 31" MAX.PANEL�r - i Digitally signed by Andre M a � S' A. Fg4/ 12 ; Felicia joENSF•'oga DN: c=US, o=engineering r f I ®Q ; . No. 75404 0 I I build NOTE: "P» TRAP I i dnQualifier=AO1410000000 91 c? 583B69000005CBC, cn= rdr., (1) FIXTURES SHALL BE INSTALLED AS TO LEAD BASE---- 3 P d _---_.J STATE OF �(/ AFFORD EASY ACCESS FOR CLEANING FLOOR Mee iciano®,�` =.!giv..••''G����� (2) FIXTURES SHALL BE SET LEVEL AND IN PROPER 'Date: 2021.06.11 09,1 �0 -04'00 ALIGNMENT WITH REFERENCE TO .ADJACENT WALLS » ' 3) GLAZING IN SLIDING AND SWINGING DOORS IN SHOWER 19/32 PLYWOOD SHEATHING, Andres M. Feliciano ( REER TO TYP. WALL SECTION H. HOSE BIBBS: CHICAGO 837 OR EQUAL WITH VACUUM BREAKER. OR TUB ENCLOSURES, INCLUDING ANY GLAZING WITHIN FOR METHOD OF ATTACHMENT 4,, FI Re P.E. # 75404 MAXIMUM FLOW RATES AND CONSUMPTION FOR g PLUMBING FIXTURES &FIXTURE FITTINGS 60 INCHES OF THE FINISH FLOOR SURFACE- IN WALLS 5. PERFORM THE FOLLOWING TEST: SURROUNDING ANY TUB OR SHOWER ENCLOSUR, SHALL (MIAMI DADS ARTICLE III, SEC. 08-31 ) BE SAFTEY GLAZING AS PER .FBC. 2411.3.1.3 A. WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF 100 PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM , BUT NOT LESS THAN ONE HOUR. B. DRAINAGE SYSTEM: BEFORE INSTALLATION OF ANY DRAINS, THE END OF THE SYSTEM SHALL BE CAPPED & ALL LINES FILLED WITH WATER TO HIGHEST POINT & ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVELS REMAIN CONSTANT. C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TEST. D. COMPLETE SYSTEM FIXTURE & EQUIPMENT SHALL BE GIVEN AN IN SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. E. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) POUNDS OF CHLORINATED LIME TO EACH 1,000 gal. OF WATER (50 PPM OF AVAILABLE CHLORINE.) RETAIN MIXTURE IN PIPES FOR 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 6 PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT Al PLUMBING SYMBOL LEGEND AFF - ABOVE FINISH FLOOR _CD CD - CONDENSATE DRAIN CD - CONDENSATE DRAIN - cw - - COLD.WATER CO - CLEANOUT - HW ---- HW ---- - HOT WATER CONT - CONTINUATION - HOT WATER RECIRCULATING CW - COLD WATER cW - NEW GREASE WASTE LINE DN - DOWN SAN - SANITARY FD - FLOOR DRAIN - - - - - - - SANITARY VENT GPM - GALLONS PER MINUTE -E E E E E E - INDIRECT LINE HB - HOSE BIBB - - - - - - NEW GREASE WASTE LINE HD - HUB DRAIN H - CLEAN OUT PLUG HW - HOT WATER 1I--0 - WALL CLEANOUT HWR - HOT WATER - CLEAN OUT RECIRCULATING ® - FLOOR DRAIN NTS - NOT TO SCALE G - ROOF DRAIN RD - ROOF DRAIN - VALVE IN VALVE BOX SAN - SANITARY VTR - VENT THRU ROOF ^^ - GATE VALVE E.C.O. = EXTERIOR CLEANOUT F.C.O. - FLOOR CLEANOUT 1 - DIRECTION OF FLOW W.C.O. - WALL CLEANOUT - ELBOW, 900 C.O.P. - CLEAN OUT PLUG - ELBOW, 450 FS - FLOOR SINK GW - NEW GREASE WASTE LINE - ELBOW, TURNED UP C - ELBOW, TURNED DOWN - TEE - TEE, TURNED UP e - TEE, TURNED DOWN PLUMBING FIXTURES OR FIXTURES FITTING: MAXIMUM FLOW RATE: LAVATORY, private 1.5 gpm AT 60 psi LAVATORY, public 0.5 gpm AT 60 psi SHOWER HEAD 1.5 gpm AT 80 psi SINK FAUCET 1.5 gpm at 60 psi URINAL 1.0 gallon cycle per flushing WATER CLOSET 1.28 gallons per flushing cycle DISHWASHER 6 gallons or less per cycle CATAGORY II SAFETY GLAZING. FBC. R4410.2.6.2 & 3 NOTE: 3" MIN ANY FIRE VENT WITHIN 10'-0" OF ANY DOOR WINDOW OR EXHAUST REFER TO PLAN FOR CONT. OPENINGS. SHALL EXTEND NOT LESS THAN 3'-0" ABOVE SUCH OF VENT AND DRAIN FIXTURE CLEARENCE DETAIL(TYP.) ROOF VENT. FLASHING DETAIL (TYP) WASHING MACHINE SUPPLY & DRAIN PIPING DIAGRAM (TYP.) N.T.S. N.T.S. N.T.S. FINISHED 1 1 WALL OR 1 1 a COLUMN ° do o° ACCESS 18 x18 x4 " THICK SCORIATED CLEANOUT COVER DOOR CONCRETE COLLANCHOR AR (ZURN Z-1406) d e ..LUGS PLUMBING WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND FOR SI: 1 gallon = 3.785 L, 1 gpm = 3.875 L/m IN AREAS W/NO SLAB CLEANOUT PLUG EMBEDDED TEE C.O. o b WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL 1 pound per square inche = 6,895 kPa _ IN CONC. DRAIN CAN BE ADJUSTED ACCEPTANCE, AND THAT HE WILL, AT HIS EXPENSE, REPAIR AND REPLACE a. A hand-held shower spray is a shower head. ( W/ BRONZE O ° TO THE HEIGHT OF THE _) I / d FINISHED TILE MUD BASE ALL WORK WHICH BECOMES DEFECTIVE DURING GUARANTEE PERIOD. b. Consumption tolerances shall be determined from referenced standards. COUNTER • p I ACCESS I DOOR SUNK PLUG � o ° FOR TILE 7. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF EXISTING UTILITIES MEMBRANE AND POINTS OF CONNECTION BEFORE COMMENCING ANY WORK. COMBINATION WYE 8. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND & wTH .BEND--------- CONNECTIONd _ CHARGES REQUIRED. °o 9. SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR INSTALLATION. 10. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE, DUCTWORK, ETC. AS SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS. 11. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A/C CONDENSATE DRAIN AND TRAP. SEE A/C PLANS FOR LOCATION OF UNITS AND DRAINS. 12. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 13. COORDINATEWORK WITH OTHER TRADES. 14. FURNISH AND INSTALL FIXTURES AS SPECIFIED IN SCHEDULE, THIS DRAWINGS. 15. EACH BATHROOM GROUP SHALL BE PROVIDE WITH SHOCK ABSORBER PER FLORIDA BUILDING CODE. 16. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE, JUST BEFORE CONNECTING TO FIXTURE. 17. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 18. PIPE INSULATION: A. ALL CONDENSATE LINE SHALL BE INSULATED WITH 3/4" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL HOT WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. PLUMBING FIXTURE CONNECTION SCHEDULE MARKS DESCRIPTION WASTE C.W. H.W. REMARKS/SPEC. WC WATER CLOSET 3" 1/2' - FLUSH MOUNTED, FLUSH TANK SH SHOWER 2" 4" 3/4 3 4" / ANTISCALD, PRESSURE BALANCING VALVE JC JACUZZI 2 " 3 4" / -3/4" ANTISCALD, PRESSURE BALANCING VALVE TUB TUB 2" 4' 3/4" 3 4' / ANTISCALD, PRESSURE BALANCING VALVE LAV LAVATORY 1-1/2" 1/2" 1/2" COUNTER TOP SK KITCHEN SINK 1-1/2" 3/4" 1/2" SINGLE COMPARTMENT SK-1 LAUNDRY SINK 1-1/2" 1/2" 1/2" SINGLE COMPARTMENT DW DISH WASHER 1-12- / - 1 2" / INDIRECT CONNECTION TO KITCHEN SINK REF REFRIGERATOR - 1/2' - PROVIDE SHUTOFF VALVE WM WASHER 3" 1/2" 1/2" PROVIDE RECESSED SUPPLY RAIN BOX QK QUOOKER 1-1/2" 3/4" 1 3/4" NOTES: 1. PLUMBING FIXTURES AND TRIM TO BE SELECTED BY OWNER. 2. MAXIMUM WATER CONSUMPTION FLOW RATES AND QUANTITIES FOR ALL PLUMBING FIXTURES AND FIXTURE FITTINGS SHALL BE IN ACCORDANCE WITH ORDINANCE 8.31 OF MIAMI DADE COUNTY. 3. ALL PLUMBING FIXTURES SHALL COMPLY WITH CHAPTER 4 OF FLORIDA PLUMBING CODE 2020, SECTIONS 406 THRU 421. WATER -TEMPERATURES LIMITING DEVICE MAXIMUM RECOMMENDED APPLICABLE FIXTURE TEMPERATURE TEMPERATURE CONTROL RANGE STANDARD LAVATORIES 49'C 38'C-49'C ASSE 1070 (1207) (1007-1207) CSA 8125.3 49•C 43'C-49'C ASSE 1070 SINKS (1207) (110'F-120'F) CSA 8125.3 49'C 38'C-43'C ASSE 1016 SHOWERS (1207) (1007-110'F) ASMEA112.18.1 CSA B125.1 BATHTUB (1207) 38'C-43'C (1007-1107) ASSE 1070 BIDET 43'C 38'C-40.5•C ASSE 1070 1 (1107) (957-105'17) CSA B125.3 NOTE: CONTRACTOR MUST VERIFY ALL EXISTING INFORMATION AND HE MUST NOTIFY THE A.O.R./E.O.R. OF ANY DISCREPANCIES BETWEEN THE FIELD AND PLANS. MiaA Dade County Department of Regulatory and Economic Resources - Job Copy 0921017036 - 9/3/2021 1:20:03 PM P-l.pdf ° FINISHED WALL THINSET DRAIN SECTION 1 ISOMETRIC OR COLUMN IL EXTERIOR CLEANOUT (TYP.) WALL 01ANOUT DETAIL (TYP) DETAIL DRAIN N.T.S. N.T.S. N.T.S. ALL DIMENSION IN ALL HOT WATER PIPE INSULATION NOTE: INSULATION FOR HOT WATER PIPE WITH A MINIMUM THERMAL RESISTANCE (R-VALUE) OF R-3 SHALL 30 MIN. BE APPLIED TO THE FOLLOWING: 1. PIPING %" AND LARGER IN NOMINAL DIAMETER. CEMENT BACKER BOARD TUBULAR PIPE INSULATION HAVING A THERMAL (OR EQUAL) MOST BE CONDUCTIVITY RATING K. PROVIDED` BEHIND WALL - THICKNESS NOT LESS THAN Y2": TILES IN WET AREAS. - K NO GREATER THAN 0.31 BTU PER IN/Hx SQFT O NOTE: DRAINAGE, WASTE AND VENT SYSTEMS SHALL BE LOCATED AND INSTALLED TO PREVENT INFILTRATION OF FLOODWATERS INTO THE SYSTEMS AND DISCHARGES FROM THE SYSTEMS INTO FLOODWATERS. 2 1 /2 IN TO 3 MUD BASE FOR TILE CEMENT BACKER BOARD IS HELD UP 1/2" FROM 0 THE MEMBRANE NAILS ARE LOCATED HIGHER THAN THE THRESHOLD. r-j 00 `-DRAIN ASSEMBLY SHOWERS MUST COMPLY WITH FBC P2708 ALL SHOWERS AND BATHTUBS SHALL BE FINISHED WITH A NONABSORBENT SURFACE AND SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET (1829 MM) ABOVE THE FLOOR. SHOWER PAN (MEMBRANE) LINING MATERIAL SHALL BE SLOPED ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL TO WEEP HOLES IN THE SUBDRAIN BY MEANS OF A SMOOTH, SOLIDLY FORMED SUBBASE. WITH NO PENETRATION LESS THAN 1" ABOVE THE. THRESHOLD. FPC 2709.3 C'J W W Cl= CN 1 1 1 v ch U co "? Z CO W W can � a C!:> o W t C w FJ- 1= U W 0 Qf REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MD AF X NEW 3K CW & 3 » /CO7f/DOR/-11 r-M74/4 /4 HW LINES TO NEW HALLWAY CONNECT TO EXIST. ew Hw HW-HW CW & %„ 'HW LINES NEV4 A ROOM S/4» VERIFY EXACT LOCATION, SIZE & CONDITION IN FIELD. 0 ER RO 3/4 I 3/4„ /ALK-1 CLOS DOUBL FRIDGE 0 'z 0 j H JAC / j WN NEW 3/4" CW & 3/4" HW LINES TO ASTE EDRO CONNECT TO EXIST. THRO c� 3/4' CW & 3X" HW LINES ATEGORY II TEMPERED z VERIFY EXACT LOCATION, G SS SHOWER ENCLOSURE C17P7 Rr rnNnITInN IN[ PIP n PF-R 7n9n cr7rTInNI `0921017036 - 9/3/2021 1:20:03 PM -- P-2.pdf C-D Z w 0 O W (3r= ol W � M U M z CO w - o Q c w ` C/D w J H U W O REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MD AF I 'I I EXISTING ASPHALT I DRIVEWAY t t r t CONSULTING ENGINEERS CA # 30228 2420 NE Miami Gardens Dr., ®_J. PROPOSED WEST SYSTEM D/F 156.4 GPD/ .80=195.5SQFT STE 203 PROPOSED WEST RESERVE AREAV11111 198 SQFT Miaml, ' FI. 33180 I XFN O H TOTAL AREA WEST SYSTEM 1294SQFT p: 305 508 0161 I N?N� I e: engineering@eng4build.com I Ile 2v EXISTING EAST SYSTEM TANK 11050 GALLON EXISTING TO REMAIN (V.I.F.) w: eng4build.com EXISTING EAST DRAIN FIELD I TO BE ..:MODIFIED 303:6 GPD .80 = 1379.5 SQFT SEAL: I / I PROPOSED EAST RESERVE AREA I 190ISQFT VALID ONLY WITH I TOTAL AREA EAST SYSTEM ;I 570 SQFT PE SEAL & SIGN. I 11 VALID FOR (1) PERMIT ONLY. B ROOM EDRO i I I Digitally signed by Andre I NEW BEDROOM NEW BEDROOM Felicia DN: c=US o=engineering f LU _': , No. 75404 O I �, / J I build _ VINE OM dnQualifier=AO1410000000 91 I J N3 I .•� V T 7R, DIN G ROO � _ �_� „ 583B69000005CBC,cn_A dr .,.. ATE OF Co "x •...... . �- M F Iclano I ,) _ N N Date. 2021.07.2216 04 00 )F % RRIDo I Andres M. Feliciano I (2)FU LA NEW HALLWAY I FI Reg P.E. # 75404 SH 2pv I I 21 E t ATHR OM WDE oo »0 wAL -1v-6 I I 2 D C SET I I /UB F E I1,114J 3) J OVEN CO C O TER INATE 2" A/C COND. DRAIN WITH A MINIMUM I 4"0 HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE OF I NEW 4" SAN LINE TO _3 110 NOlI LESS THAN 1/8" UNIT VERTICAL IN 12. UNITS BATH OMC I NEW PROPUSED SEPTIC VTR (2)FU MA S R BED OM HORIZONTAL TO OUTSIDE 6" A.F.G. DRAIN TO BE 12" O SH AWAY TANK � Y FROM OUTSIDE WALL. SEE DETAIL ON M--1. I (V.I.F.) CATEGORY 11 TEMPERED I I 3 (� - NE GLASS SHOWER ENCLOSURE r / PER FBC '2020 SECTION I � �_ 1 l I / g "MOO '? f ATI7(_nPY 11 nt\1 SEPTIC TANK 'CALCULATIONS • • 1• • •'w • • • w • • w • • • TOTAL FLOW 460 • TOTAL F/U 36 (FIXTURES U ITS) WEST SYSTEM 12/36=66% OF FLOW • EAST SYSTEM FLOW 156.4 I • • • • ""' • • EAST SYSTEM 24/36=66% OF I FLOW • EAST SYSTEM FLOW 303.E ' PROPOSED WEST SYSTEM TANK I900 GALLON I EXISTING SHOWER TO BE REPLACED a� �^ PROPOSED :SEPTIC TANK � WITH ANEW TUB AT SAME. LOCATION NOTE. �t I AND USINGEXIST."PL MBING. WATER v I I (UNDER SEPARATED s SA�1 SAN AND DRAINAGE LINES. U EXI�•STIN PERMIT BY OTHERS " , 3 b "SA .LINE 1-4ALL TOILET FLANGES. SHALL BE I / TO REMAIN _ I PROPERLY ADJUSTED TO ANY NEW I Y (V.I.F.) W I FLOOR HEIGHT:.. I ''< I'_ I .I I ry I 16'-24„ a• w v CNI 0 0 I Z - I W 0 O w H N U '2. M U M z W 9=3 a 05 W ci J F- F-- V W O fY REVISION No. DATE THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MD AF 0921017036 9/3/2021 1:20:03 PM P-3.pdf k / - vfcvr �vvrrr % UKV Igl a y slgne y Anare , sM;FF� NEW BEDROOM NEW BEDROOM / Felicia �,ao_ tee••%, � DN. c—US, o—eng nee ng E f Lli build : ° No. 7599 `', 0 w dnQualifier=AO1410000000 9 Z VING OM N3 f .• DIN G R00 / 1583B69000005 , BCC w cn=Andres M Fe pia TATEOP ° , � � � Date: 2021.08. :25:42 �,�� � p �_�_e NEN a �►�'° i f 6/ -04 00 � RRIDo l Andres Feliciano, l (2)Fu a NEW HALLWAY z Al Fl Reg P.E. # 75404 SH f 2„ - (1 TR 1) NE ATHR OM A a CO 1 l » WDE 00 l 2� 221 1 »0 j f U OWAL -N l err D f A C flSET 1 usi_ a 3) OVEN XE (2)F l S CO r C f 1 TER INATE 2 A/C COND. DRAIN WITH A MINIMUM 4»� �_j ( 0 HORIZONTAL SLOPE 1N THE DIRECTION OF DISCHARGE OF { W , » ,r - l NEW 4 SAN LINE TO 3 0 NO LESS THAN 1/8 UNIT VERTICAL IN 12-.UNITS - VTR ,, (2)FU PAAS R BED OM / HO IZONTAL TO OUTSIDE 6 A.F.G. DRAIN TO BE 12 NEW PROPOSED SEPTIC / i f BATH OMCO SH AWAY TANK � / Y FROM OUTSIDE WALL. SEE DETAIL ON M-1. CATEGORY II TEMPERED l 30' i' NEW GLASS SHOWER ENCLOSURE' l r C� r / % PER FBC 2020 SECTION II ?4(1F 7 ( CI `ATFC,RY II C1N t I l EXISTING_ SHOWER TO BE REPLACED f 2 NOTE: PROPOSED SEPTIC TANK � WITH A NEW TUB AT SAME- LOCATION �t 1 4 N I AND USING EXIST. PLUMBING 'WATER (UNDER SEPARATED EXISTIN SM SAN SAP' AND DRAINAGE LINES. l PERMIT, BY OTHERS) f ALL TOILET FLANGES SHALL BE 3" 0 SA .LINE � 1 TO REMAIN x I PROPERLY ADJUSTED TO ANY NEW w FLOOR HEIGHT.'; Y l Z f (V.I.F.) l j l � f l04 4 2� Q v U U U Z / - vfcvr �vvrrr % UKV Igl a y slgne y Anare , sM;FF� NEW BEDROOM NEW BEDROOM / Felicia �,ao_ tee••%, � DN. c—US, o—eng nee ng E f Lli build : ° No. 7599 `', 0 w dnQualifier=AO1410000000 9 Z VING OM N3 f .• DIN G R00 / 1583B69000005 , BCC w cn=Andres M Fe pia TATEOP ° , � � � Date: 2021.08. :25:42 �,�� � p �_�_e NEN a �►�'° i f 6/ -04 00 � RRIDo l Andres Feliciano, l (2)Fu a NEW HALLWAY z Al Fl Reg P.E. # 75404 SH f 2„ - (1 TR 1) NE ATHR OM A a CO 1 l » WDE 00 l 2� 221 1 »0 j f U OWAL -N l err D f A C flSET 1 usi_ a 3) OVEN XE (2)F l S CO r C f 1 TER INATE 2 A/C COND. DRAIN WITH A MINIMUM 4»� �_j ( 0 HORIZONTAL SLOPE 1N THE DIRECTION OF DISCHARGE OF { W , » ,r - l NEW 4 SAN LINE TO 3 0 NO LESS THAN 1/8 UNIT VERTICAL IN 12-.UNITS - VTR ,, (2)FU PAAS R BED OM / HO IZONTAL TO OUTSIDE 6 A.F.G. DRAIN TO BE 12 NEW PROPOSED SEPTIC / i f BATH OMCO SH AWAY TANK � / Y FROM OUTSIDE WALL. SEE DETAIL ON M-1. CATEGORY II TEMPERED l 30' i' NEW GLASS SHOWER ENCLOSURE' l r C� r / % PER FBC 2020 SECTION II ?4(1F 7 ( CI `ATFC,RY II C1N t I l EXISTING_ SHOWER TO BE REPLACED f 2 NOTE: PROPOSED SEPTIC TANK � WITH A NEW TUB AT SAME- LOCATION �t 1 4 N I AND USING EXIST. PLUMBING 'WATER (UNDER SEPARATED EXISTIN SM SAN SAP' AND DRAINAGE LINES. l PERMIT, BY OTHERS) f ALL TOILET FLANGES SHALL BE 3" 0 SA .LINE � 1 TO REMAIN x I PROPERLY ADJUSTED TO ANY NEW w FLOOR HEIGHT.'; Y l Z f (V.I.F.) l j l � f l04 4 2� Q v U U U Z _J W O wcli �/ CA st W -a ch U M. M Z to LL L1 1 O Q W CD t/3 i W J U D O REVISION No. DATE 8/18/21 THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MID AF 0921017036 - 9/3/2021 1:20:03 PM P-3 V2.pdf WEST B/M 13.65' EAST SYSTEM B/M13.92 O . • • • • • " .. • • • • • 4 go* too CONSULTING ENGINIERSFF I I EAST SYSTEM FLOW 156.4 STE 203 CA # 30228 2420 NE Miami Gardens Dr., W i EAST SYSTEM 24/36=66% OF FLOW o I I Miami, FI.33180 II o EAST SYSTEM FLOW 303P.6 p: 305,508 0161 I = I I e: engineering@eng4build.com _ I I PROPOSED WEST SYSTEM TANK 900 GALLON w eng4build.com I o PROPOSED WEST SYSTEM D/F 156.4 GPD/ .80=195.5SQFT N I N I I PROPOSED WEST RESERVE AREA 98 SQFT SEAL: TOTAL AREA WEST SYSTEM - 294SQFT VALID ONLY WITH I ASPHALT. 101-011 ' EXISTING EAST SYSTEM TANK 1050: GALLON EXISTING TO REMAIN (V.I.F.) PE SEAL & SIGN. IQ I EXISTING EAST DRAIN FIELD VALID FOR (1) PERMIT ONLY. DRIVEWAY TO BE MODIFIED 303.6 GPD .80 379.5 SQFT Iw I / Digitally signed by Andre to I Felicia Ip PROPOSED EAST RESERVE AREA 190 SQFT LENS v,�C •� F TOTAL AREA EAST SYSTEM 570 SQFT DN: c=US, o=engineering r I build No. 7 :o saoa 0 o I dnQualifier=A01410C00000 9 = e o cm I 1583B6900000 BC,STATE OF N L — _ — — —) _ 25' FRONT SETBACK 25' FRONT SETBACK 25' FRON SETBACK I cn=Andres M Fe is �.,. -- — —EXISTING ASPHALT— — — — — — — — — — — — — — — — — — — — — —— Date:2021.07.. _ :23:19 DRIVEWAY I I 7 / I '-04'00 i� �Ntd4►�.% I Andres .Feliciano I' I 14�_1�� FI Reg P.E. # 75404 'I 14 -5 ss I!s'1Uiri SEPTIC TANK CALCULATIONS TOTAL FLOW 460 :.. TOTAL F/U 36 (FIXTURES UNITS) WEST SYSTEM 12/36=66% OF FLOW CIE) Z J IL.0 (=Zk O w _ F— N W -a M U M M 0 o a W C/.> 14 J H U w O REVISION No. DATE THESE PLANS ARE FOR BUILDING . DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MID AF I 16'24., w t `' d -O U U U U PROPOSED WEST SYSTEM D/F 195.5 SQFT a a a a I PROPOSED WEST RESERVE AREA 98 SQFT _ TOTAL AREA WEST SYSTEM 354 SQFT — — — — — �- — — — — — — — — — — — — — — — — — — — — — — I . 6' UTILITY EASEMENT N O� 6' UTILITY EASEMENT ocl� 20'-84..--- 10i_On It.0in EXISTING EAST DRAIN FIELD TO BE MODIFIED 379.5 SQFT PROPOSED EAST RESERVE AREA 190 SQFT — PROPERTY LINE — — TOTAL AREA EAST SYSTEM 570 SQFT — — — -�- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — _ I I� OLSCA=�. MBING �QE PLAN /16" = 0 L Dade County Department of Regulatory and Economic Resources - Job Copy )17036 - 9/3/2021 1:20:03 PM ;)df see* • ee• •ee• `E i ICWJ •. • • • eeeee CONSULTING ENGINEERS CA # 302?29 r4ft 2420 NE Miami Gardens Dr., { STE 203 Miami, FI. 33180 p: 305 508 0161 e: engineering @eng4build. corr� w: eng4build.com SEAL: VALID ONLY WITH PE SEAL & SIGN. VALID FOR (1) PERMIT ONLOft- Digitally signed by Andre M®®�y Felicia ' DN: c=US a=engineering . r ki Nil z w 0 O w h- CV C) � W -2 Cl) V M Z U- ��-k W c CA> co cn 6i .J H f= U W O d aa.ac5uc+?��fa,: REVISION No. DATE 0 8/18/21 mw THESE PLANS ARE FOR BUILDI DEPARTMENT REVIEW ONLY. THEY ARE NOT TO BE CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALSARE OBTAINED. date: May 14th, 2021 project no. 2137 drawn by checked by MD AF v I