BCE20-0773
On_ ..1111111111k SCOPE OF WORK INSTALLATION OF A NEW MONITOR MODULE FOR KITCHEN HOOD FIRE SUPPRESSION SYSTEM AS SHOWN ON PLANS BUILDING IS EXISTING. FIRE ALARM SYSTEM IS EXISTING GENERAL NOTES 1. THIS FIRE ALARM SYSTEM IS PROVIDED UNDER NFPA 101 2015ed 2. SYSTEM IS A POWER LIMITED FIRE ALARM SYSTEM. 3. SIGNALING LINE CIRCUITS (SLC) SHALL BE CLASS B. 4. NOTIFICATION APPLIANCE CIRCUIT SHALL BE CLASS B. 5. BUILDING FIRE ALARM SYSTEM IS CLASSIFIED AS A LISTED AS A CENTRAL STATION FIRE ALARM SYSTEM AND IS PROVIDED WITH 24 HOURS OF SECONDARY NON -ALARM POWER AND 5 MIN. OF SECONDARY ALARM POWER AS PER NFPA 72. 6. BUILDING IS NOT SPRINKLERED. 7. ALL EQUIPMENT SHALL BE UL LISTED, COMPATIBLE AND LISTED FOR USE IN FIRE ALARM. 8. INSTALLATION SHALL COMPLY WITH: FLORIDA FIRE PREVENTION CODE (FFPC) 6TH EDITION FLORIDA BUILDING CODE (FBC) 6TH EDITION NFPA 1, 2015 EDITION, FIRE CODE NFPA 101, 2015 EDITION, LIFE SAFETY CODE NFPA 72, 2013 EDITION, NATIONAL FIRE ALARM CODE NFPA 70, 2014 EDITION, NATIONAL ELECTRICAL CODE 9. CONDUITS SHALL BE 1/2" MINIMUM WITH A MAXIMUM FILL OF 40 AND COMPLY WITH NEC. 10. SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATIONS. 11. MINIMUM WIRE SIZE SHALL BE .#18 AWG COPPER UNLESS NOTED OTHERWISE. 12. CONDUCTORS SHALL HAVE MINIMUM RATING OF 300V AND SHALL BE OF SOLID COPPER OR BUNCH -TINNED STRANDED COPPER CONDUCTORS. TYPE AS SPECIFIED ON PLANS. 13. ALL DEVICES OR UNITS SHALL BE INSTALLED USING APPROVED MATERIALS AND WIRING PRACTICES IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE NFPA 70 ARTICLE #760 POWER LIMITED SECTION AND ALL APPLICABLE LOCAL WIRING ORDINANCES 14. CEILING HEIGHT LESS THAN 10' (EXCEPT WHERE SPECIFIED) 15. ALL OUTDOOR FIRE ALARM DEVICES TO BE WEATHERPROOF TYPE. 16. OFF -SITE MONITORING IS PROVIDED (CENTRAL STATION SERVICE) _, 17. ALL SMOKE DETECTORS MOUNTED MORE THAN 3' AWAY FROM A/C DIFFUSERS. 18. INTERCONNECTED FIRE ALARM CONTROL PANEL, NAC POWER SUPPLY, AND DEVICES SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND MONITORED FOR INTEGRITY PER NFPA 72 19. ALL HORN/STROBES SHALL BE UL LISTED UNDER STANDARD 1971 (SIGNALING DEVICES FOR THE HEARING -IMPAIRED) 20. VISUAL NOTIFICATION DEVICES SHALL COMPLY WITH THE LATEST EDITION OF ADA GUIDELINES, BE SYNCHRONIZED WHEN REQUIERED, CLEAR XENON TYPE, AND WITH MIN. INTENSITY OF 75 CANDELAS UNLESS NOTED OTHERWISE ON PLANS. 0920015447 F-A-1 FAQ-1.p James Ham L-- A SECTION A -A 1. Floor or Wall Assembly - Mn 4-112 In. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks•. Max dllam of opening is 32 in. 2. Metallic Sleeve - (Optional) Nom 32In. diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor orwail surfaces or extending a max of 3 in. above floor or beyond both surfaces of wall. 2A. Sheet Metal Sleeve - (Optional) Max 6 In. diem, min 26 ga galy steel provided with a 26 ga galy steel square flange spot welded to the sleeve at approx md-height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. below the bottom of the deck and a max of 1 In. above the top surface of the concrete floor. 28. Sheet Metal Sleeve - (Optional) - Max 12 in. diam, min 24 ga gale steel provided with a 24 ga gale steel square flange spot welded to the ' sleeve at approx mid -height, or flush with bottom of sleeve in floors, and sized to be a min of 2 In. larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. below the bottom of the deck and a max of 1 in. above the top surface of the concrete floor. 3. Through -Penetrant - One metallic pipe, tube or conduit to be installed either concentrically or eccentrically within the ffrestop system. The annular space between penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. Penetrant may be Installed with continuous point contact Penetrant to be rigidly supported on both sides of fir or wall assembly. The following types and sizes of metallic penetrants may be used: A. Steel Pipe - Nam 30 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron PlIte - Nom 30 in. diam (or smaller) cast or ductile iron pipe. C. CoppO Pipe Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe. D. Coppei Tubing - Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Conduit - Nom 6 in. diam (or smaller) steel conduit F. Condul - Nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT). 4. Firestop System - The firestop system shelf consist of the following: A. Packing Material - Mn 4 in. thickness of min 4 pof mineral wool bait insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or sleeve or from both surfaces of wall or sleeve as required to accommodate the required thickness of fill material B. Fill, Vold or Cavity Material"- Sealant - Min 1/4 In. thickness of fill material applied within the annulus, flush with top surface of floor or sleeve or with both surfaces of wall or sleeve. At the point or continuous contact locations between penetrant and concrete or sleeve, a min 1/4 in. dam bead of fig material shall be applied at the concrete or sleeve/ pipe penetrant interface on the top surface of floor and on both surfaces of wag. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - FS-One Sealant 'Bearing the UL Classification Mark r ME, Reproduced by HiLTI, Inc. Courtesy of Underwriters Laboratories, Inc. H11tl Firestop Systems June 27,2007 21. AUDIBILITY SHALL BE AT LEAST 15 dB ABOVE THE AVERAGE AMBIENT r, SOUND OR 5 dB ABOVE THE MAX. SOUND LEVEL, WHICHEVER IS GREATER IN THE OCCUPIABLE AREA. THE ENTIRE E/VI S IS NODT LESSLTHAN DEVICES80" ABOVE THE HIGHEST FLOOR AT FIRE ALARM LEGEND THE ENTIRE LENS I LEVEL WITHIN THE SPACE OR 6" BELOW THE CEILING WHICHEVER IS I LOWER AS PER ADOPTED EDITIONS OF ADA GUIDELINES, FLORIDA BUILDING ® EXISTING ADDRESSABLE FIRE ALARM CONTROL PANEL CODE AND NFPA 72. F.G.I. GWF-7075 23. WALL -MOUNTED AUDIBLE NOTIFICATION APPLIANCES SHALL HAVE THEiR I` TOPS ABOVE THE FINISHED FLOOR AT HEIGHTS OF NOT LESS THAN 90" EXISTING AUDIBLE/VISIBLE NOTIFICATION APPLIANCE (HORN/STROBE) AND BELOW THE FINISHED CEILINGS AT HEIGHTS OF NOT LESS THAN 6" fic SYSTEM SENSOR, L-SERIE, CEILING MOUNTED AS PER ADOPTED EDITIONS OF NFPA 72 TYE MODEL: PC2WL (75cd) 24. THE OPERABLE PART OF EACH MANUAL FIRE ALARM BOX SHALL BE WP EXISTING AUDIBLE/VISIBLE NOTIFICATION APPLIANCE (HORN/STROBE) AT 48 INCHES ABOVE FLOOR LEVEL AND COMPLY WITH NFPA 72 AND ADA SYSTEM SENSOR, SERIE SPECTRALERT, WALL MOUNTED WEATHER PROOF REQUIREMENTS. TY E MODEL: P2WK (75cd) EXISTING VISIBLE NOTIFICATION APPLIANCE (STROBE) SEQUENCE OF OPERATION J - SYSTEM SENSOR, L-SERIE, 'WALL MOUNTED TYPE- MODEL: SWL (75cd) ANY INITIATING DEVICE ACTIVATED SHALL CAUSE THE FiRE ALARM PANEL EXISTING VISIBLE NOTIFICATION APPLIANCE STROBE TO GO INTO ALARM CONDITION, DISPLAY THE DEVICE OR ZONE ON THE } S`(STEM SENSOR, L-SERIE, CEILING MOUNTED ) FRONT OF PANEL AND REMOTE ANNUNCIATOR, ACTIVATE ALL NOTIFICATION TYPE MODEL: SCWL (75cd) DEVICES THROUGHOUT THE BUILDING, TRANSMIT SIGNAL TO LISTED CENTRAL STATION AND ACTIVATE OR OPERATE ANY AUX. RELAYS OR ,llEXISTING ADDRESSABLE SMOKE DUCT DETECTOR FUNCTIONS AS NOTED ON FLOOR PLANS AND RISER DIAGRAM. `v2l MODEL: F.C.I. DNR W/ASD-PL2FR E 75cd CORRIDOR NAC 1 N105 L1SO4 EOL DINNING N1 6 E E N 07 AREA 75cd 75cd af L1S03 MEN'S n nWOMEN'S L1M02 E COOLER AHU1 E 1M05 MAI N ENT CE 75cd KI CHEN E REA N104 L S06 EAHU2 KITCHEN 7gr r_- me "i EEr ®ELIMO61KfTCHEN L1 S02 Sl1RPPRES ON NEW 75cd / L1M07 Eic �.m��.� 75cd Es N 102 fic (DE N101 DINNING LIS01 E AREA L1M03 BACK KITCHEN L1MO1 C1 IQ E , E N103 E 75cd WP Lj PATIO (OUTSIDE DINNING AREA) i.. FIRE ALARM' FLOOR PLAN SCALE: 1 /8" = 1'-0" 0' 2' 4' 8' 16' I THIS IS AN EXISTING CERTIFICATED "CENTRAL STATION SERVICE FIRE ALARM SYSTEM" FIRE ALARM IS MONITORED BY LISTED CENTRAL STATION SCOPE OF WORK MODULE NEW MONITOR FOR KITCHEN HOOD FIRE SUPPRESSION SYSTEM EXISTING -FIRE ALARM CONTROL PANEL ANY TROUBLE SIGNAL SHALL BE INDICATED AT THE FIRE ALARM CONTROL EXISTING MANUAL INITIATING DEVICE (PULL STATION) MODEL: F.C.I. MS-7AF PANEL, REMOTE ANNUNCIATOR AND UL LISTED CENTRAL STATION. BUILDING IS EXISTING '. ANY ALARM SIGNAL SHALL BE INDICATED AT THE FIRE ALARM CONTROL © EXISTING ADDRESSABLE TYPE PHOTO SMOKE DETECTOR BUILDING IS NOT SPRINKLERED PANEL, REMOTE ANNUNCIATOR AND UL LISTED CENTRAL STATION. MODEL:-F.C.I. ASD-PL2F ANY SUPERVISORY SIGNAL SHALL BE INDICATED AT THE FIRE ALARM CONTROL ALL DEVICES LOCATED OUTDOORS ARE LISTED FOR THE ENVIROMENT MI L REMOTE ANNUNCIATOR AND UL LISTED CENTRAL STATION ® EXISTING REMOTE TEST SWITCH t BATTERY CALCULATION FOR F.C.I. GWF-7075 see , , . . . . . . ..... , . . . , Is, . . . , . . , TOTAL ALARM LOAD 1.3376 TOTAL AMPERE HOURS CALCULATION REQUIRED STANDBY TIME IN HOURS i, (24 OR 60 HRS) / STANDBY LOAD CURRENT (AMPS) 0.1688 X 24 = 4.0512AH REQUIRED ALARM TIME IN HOURS (5 MINUTES = 0.0833H) ALARM LOAD CURRENT (AMPS) 1,633 X 0.0833 = 1.3376AH TOTAL CURRENT LOAD 4.1622AH ' MULTIPLY BY THE DERATING FACTOR 1.2 = X 1.2 TOTAL AMPERE HOURS REQUIRED 5.00AH BATTERY PROVIDED - 7AH FACP F.C.I. GWF-7075 DC "RMS" LOAD VALUES HAS BEEN USED FOR NAC CALCULATION AS PER THE LATEST MFG. SPEC. SHEET. SEE ATTACHED SPEC. SHEET. t NAC VOLTAGE DROP' CALCULATION CIRCUIT NUMBER AND BATTERY PROVIDED - 7AH FACP F.C.I. GWF-7075 DC "RMS" LOAD VALUES HAS BEEN USED FOR NAC CALCULATION AS PER THE LATEST MFG. SPEC. SHEET. SEE ATTACHED SPEC. SHEET. t NAC VOLTAGE DROP' CALCULATION CIRCUIT NUMBER AND TOTAL IN A E , MODEL SYSTEM SENSOR RTS-151 (*) APPLIANCES OPERATING .VOLTAGE LIMITS AS PER MANUFACTURER 16 - 33 ,VOLTS UPON ACTIVATION OF ANY MANUAL STATION THE FOLLOWING SHALL OCCUR: ADDRESSABLE MONITOR MODULE 1. THE FACP SHALL DISPLAY THE DEVICE OR ZONE IN ALARM. ® MODEL: AMM-2F Z. THE FACP SHALL ACTIVATE ALL NOTIFICATION DEVICES THROUGHT THE BUILDING ® ADDRESSABLE RELAY MODULE UPON ACTIVATION OF ANY SMOKE DETECTOR THE FOLLOWING SHALL OCCUR: MODEL: AOM-2RF II 1. THE FACP SHALL DISPLAY THE DEVICE OR ZONE IN ALARM. E - DENOTES EXISTING DEVICE 2. THE FACP SHALL ACTIVATE ALL NOTIFICATION DEVICES THROUGHT THE N - DENOTES NEW DEVICE BUILDING. UPON ACTIVATION OF ANY SMOKE DUCT DETECTOR THE FOLLOWING SHALL OCCUR: EXISTING DEVICES AC A/ C 1. THE FACP SHALL DISPLAY THE DEVICE OR ZONE IN SUPERVISORY. SHUT SHUT 2. THE FACP SHALL SHUT -DOWN RELATED AHU UPON ACTIVATION OF ANY KITCHEN HOOD F/S THE FOLLOWING SHALL OCCUR: 1. THE FACP SHALL DISPLAY THE DEVICE OR ZONE IN ALARM. 2. THE FACP SHALL ACTIVATE ALL NOTIFICATION DEVICES THROUGHT THE BUILDING. UPON ANY AC POWER LOST -OR BATTERY FAILURE THE FOLLOWING SHALL OCCUR: 1. THE FACP SHALL DISPLAY AC OR BATTERY FAILURE TROUBLE.- UPON ANY OPEN CIRCUIT, GROUND FAULT OR SHORT 'CIRCUIT IN ANY NOTIFICATION APPLIANCE CIRCUIT THE FOLLOWING SHALL OCCUR: 1. THE FACP SHALL DISPLAY THE CIRCUIT OR NAC IN TROUBLE. UPON ANY OPEN CIRCUIT OR GROUND FAULT IN ANY INITIATING DEVICE CIRCUIT THE FOLLOWING SHALL OCCUR:- 1. THE FACP SHALL DISPLAY THE CIRCUIT OR ZONE IN TROUBLE. FIRE ALARM PANEL SHALL TRANSMIT ALL ALARM, TROUBLE AND SUPERVISORY -SIGNALS TO THE MONITORING STATION (UL LISTED CENTRAL STATION) b`ol Q� <c.�G� oQ 0 ® .� l+�`G MANUAL PULL STATION • • • • • • STROBE OR HORN/STROBE �• O 80" A.F.F. OR O 6" ELOW CEILING O (WHICHEVER IS LOWER) PULL STATION 48' A.F.F. TO HANDLE O ADA) rr MOUNTING DETAI a DOWN DOWN L1MO6 L1M05 N ;- DENOTES NEW DEVICE E E E '- DENOTES EXISTING DEVICE A RECOMMENDED MAX. DISTANCE FEET (018AWG): 3000' ESTIMATED DISTANCE FEET: 1500' E E SCOPE OF WORK E E D' MAX. ADDRESSABLE DETECTORS 75 NEW MONITOR MODULE L1S06 L1S05 ` A ACTUAL. ADDRESSABLE DETECTORS 6 FOR KITCHEN HOOD FIRE SUPPRESSION SYSTEM MAX. ADDRESSABLE MONITORS 75 EXISTING DEVICES ACTUAL. ADDRESSABLE MONITORS 6 E E E E WIRE LEGEND CHART TYPE Ln CONDUCTOR/DESCRIPTION A SLC 2 ; # 18 FPLP (USE �dN DRY -,LOCATION) 2 #16 AWG,TFFN y(USE .IN WET LOCATION) B NAC 2 #14 FPLP (USE "IN DRY LOCATION) 2 #14 AWG, THWN (USE IN WET LOCATION) P I PWR 2 #12 AWG, THWN '& 1#12 (G) IN 1/2"C NEW L1SO4 L1SO3 L1S02 LIS01DEVICE A THE LOCATION OF FIRE ALARM PNL. AND POWER SUPPLY , COMPLY WITH THE REQUIREMENTS OF NFPA72 (2013ed) HOOD SYSTEM EX5'TiNG DEVICES t ARTICLE 10.14.1 PERFORMANCE AND UMITATIONS E E EXISTING NOTIFUTKIN APPLIANCES ACCESS AND WORKING SPACE IS PROVIDED FOR THE FIRE ALARM CONTROL UNIT AND POWER SUPPLY IN N LIM07 F L1MD3 F F L1MO2 L1MO1' EXISTING E WP 0.143A 0.143A 0.176A 0.143A 0.111A 0.107A 0.107A COMPLIANCE WITH THE NEC (2014ed) ARTICLE 110.26 r A 75cd 75cd 75cd # 75cd 15cd 15cd 15cd EM NAC 1 E ~ MAXIMUM MOUNTING HEIGHT FOR FACP AND POWER SUPPLIES N101' N102 N103 N104 N105 N 6 N1 7 4.7k,1/2W IS 6 FEET TO TOP OF ENCLOSURES B f A FIRE ALARM PANEL LOCATION TO BE MECHANICALLY VENTILATED. TELCO - MAX. LOAD 2A TWO DEDICATED - EXISTING CURRENT LOAD 0.930A ALL SMOKE DUCT DETECTORS TO BE POWERED WiTH 24VDC SOURCE TELEPHONE LINES FACP F.C.I. GWF-7075 VOLTAGE AT FROM THE FACP AND SATISFY NFPA 72 4.4.7 REQUIREMENTS TELCO LAST DEVICE 19.55V C1 20A RATED DEDICATED 120V ' Jc BRANCH CIRCUIT PNL. P1-1 P GROUND LEVEL GROUND LEVEL - FIRE ALARM RISER DIAGRAM I KITCHEN FIRE SUPPRESSIO • • • • • • Mftix W • • • CKT/CABUNG GROUND • • • • SEQUENCE OF OPERATION MATRIX ,,,,t,OlOUrp, CARLOS JAVECH, PE N;Y,% ThrsaamMabe.ndlghallyslgnadanda-led by Carlos JdV2Ch 7487 SW 50 TERRACE s f i. arks Leath, PE using a Digital slgnatun and Dab. a• a etsss 'j�= Printed coOes of this document are ra I, MIAMI FL 33155 l armor j) 'o considered signed and sealed and the SXA J authentication code must be verified an arty 2020.07.2811:00:22-04f00' PE LICENSE No 53858 rrrrlUnp„Up elettronkcopl S. a r i O N O pro O O O L0 � � 0 O O O .. X � v I- L'- N N O O O W O J N ct J V- Q W v) Z W cv \ - m - _N WO OWE ti Z Q � W 3?; m Li W Z N. vW 06E O _1 N � � • L,J � F- Q 0070 L,J (-V' Q <Z Q z W Q L� l� .__I l_rD Q Q 3� QP CY- z 3 Q O J DRAWN RV CHECKED CJ DATE 07/23/20 SCALE AS SHOWN JOB NO, 072320 SHEET FA-1 OF 1 SH ••• ••i•f • • ••• •••. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 000 • • • • o • •••• • 000A • ••• • ••it• • ••••