07-366-001NEW MECH.TEE NEW MECH,TEE 2'X1' 2'Xl%' FITTER TO FITTER TO LEAVE LEAVE COUPON ON COUPON ON MECH MECH TEE TEE i i O BATH ROOM i LUNCH: , ROOM .\.� • RELO �o ---------- --_T------ -11 1,3 A/H STORAG UNIT 1 1 I I RELO I 1 I I 1 I 1 • RELO S.W 60TH AVENUE NEW MECH.TEE 2'X1' FITTER TO LEAVE COUPON ON MECH TEE Flo )RELO CU I I 1 • RELO 0 FIRE SPRINKLER PLAN. SPACE 105-106 SCALE 1 /4" = 1'-0 I i I I J I � w 1 o w ¢ A � W L-3W J � Y F— Z U CL I `1 ~I W Z I 1 1 b Fire Protection Criteria ALL MATERIALS & INSTALLATION SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13 (2002) REQUIREMENTS. SPRINKLERS SHALL BE 5.6K, 155' FAHRENHEIT, SEMI -RECESS PENDENT. DESIGN CRITERIA IS IN ACCORDANCE WITH NFPA 113 FOR ORDINARY HAZARD OCCUPANCY GROUP 2 FOR STORAGE AREAS. ALL OTHER AREAS ARE LIGHT HAZARD. INTERIOR SPRINKLER PIPE TO BE XL OR BLACK STEEL SCHEDULE 40 ALL HANGER MATERIALS AND SPACING SHALL COMPLY WITH NFPA #13. Scope of Work THIS IS AN EXISTING 5 STORY OFFICE BUILDING WITH AN EXISTING FIRE SPRINKLER SYSTEM. WORK TO BE DONE ON AREAS SHOWN. HATCHED AREAS OR OTHER NON SPECIFIED AREAS ARE NOT PART OF THIS PERMIT. SCOPE OF WORK IS TO RELOCATE (9) FIRE SPRINKLER HEADS AND INSTALL (7) NEW FIRE SPRINKLER HEADS. FOR NEW BOUTIQUE F'UWUtK A:IUAItU PIN CLOBEA uTom-4Trc SPREvALERs �� �P�2f�+1W�C;� GL SERIFS` RiAg �0N fir+ NDENT VERTIC, a SMEWM.L DESC'"TION,0M OPE"T701Y CO ENTIiQ AL (OLD} STD) The Globe Quick Response GL Series Sprinklers are a low pro ile yet durable des-M wtdch ubl frangible a 3mm frange glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers_ While the Quick F-yam: Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spmy sprinklers arse specified when allowed by ttm applicable standards. It offers the additional feature of greatly increased safety to life and is available in various sues, Orifrces,:....h. temperature ratite and finishes tct meet many varying design require- ments. (wick Response Sprinklers should be used advisedly and under the diction of approving authorities having jurisdiction - The heart of Glee`s GL Series sprinkler proven acbmting QUICK RESPONSE assembly is a hernneticalty sealed frangible glass: ampule that contains UPRIGHT CONVENTIONAL a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds fm s'tmngth of the glass causing the glass to shatter. This re3uits in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory aw&rnbleri. ,As- sembly is done in the field. TEmm L DATA QUICK RESPONSE a See (evmeWefiDrAppi0'% al sandSpeci ic2bDns- PENDENT VERTICAL *Temperature Ratings- 13FF(5TC),1 WF (68°C),Al75*F(79°C), sIDEWALL 200*F (93*% 286"F(141 "Q. • Water Working Pressure Rating'-175 psi (12 Bats). • Fatorytested hydrostatilt allyto 5130 psi(34 Bala). • maximmnlortemperaatureglassbulb rating is-67QF (-550% • Frame - bronze o Deflertvr - brass s Screw - buss * Bulb seat- copper 9 Spring -nickel alloy • Steal-teflon • SIDE Bulb-glassy atcoholbased ion,3mmsim. QUICK HORIZONTAL SIQEl�rrslr QtiWALL :,SPRINWLER TE_X1 Ek47VRF, k4TLVG1C'E..4SS1FICATTI0JV and COLOR C'ODEVG 4077A1RPARrCORRIE.STANDISH.IGDHIGAN 4I DECEMBER 20M A-213 NOTE: FIRE SPRINKLER CUT SHEETS SHALL BE AVAILABLE ON SITE FOR FIELD FIRE INSPECTOR. SYMBOL QTY SIZE K TEMP MODEL SIN O 16 1/2' 5.6 155 GLOBE GL SERIES OR PENDENT GL5601 NO. DATE 1 2/5/07 v FAxl-e4t BULLETIN GL5816. REV_ #8 REVISIONS SUBMIT FOR APPROVAL 3/8' ALL THREAD ROD (ATR) ATTACHED TO CONCRETE WITH 3/8' POWDER ACTUATED PIN & 3/8 ROD CPLG. (FOR 'TTH 4- PIPE & SMALLER). #05 Hamer Detail NO SCALE GALVANIZED HANGER RING. FIRST PAGE WN a> — I ARMOVERS GREATER THAN 24' IN LENGTH SHALL BE SUPPORTED BY A HANGER. SCHEDULE 1. EXIST BRANCHLINE OR MAIN 2. NEW TEE '(SIZE VARIES, SEE PLAN) 3.'ARMOVER.i (SIZE VARIES; SEE PLAN) _4.1, 90' ELL OR TEE=l-� •-5,. DROP (SIZE -VARIES,"-SEE PLAN MAY FEED, TEE- SUPPLYING MORE THAN ONE SPRINKLER) 6. NEW SEMI -RECESSED PENDENT FIRE SPRINKLER 7. CEILING. 8. NIPPLE 9. REDUCING CDPULING (SIZE VARIES, SEE PLAN) Hanger Location Detail PIPE SIZE A B* C 1' 3'-0" MAX. 12'-0' MAX. 3' MIN. 1-1/4' 4'-0' MAX. 12'-0" MAX. 3' MIN. 1-1/2'rH 8' 5'-O' MAX. 15-0' MAX. 3' MIN. A B* C SPRINKLER HEAD STEEL PIPE LHANGER * MAXIMUM HANGER SPACING FOR THREADED LIGHTWALL STEEL PIPE IS 12'-0' FOR ALL PIPE SIZES SUPPRESSION SYSTEM APPROVED BY MIAMI-DDE COUNTY FIRE DEPARIPAENT SPRINKLcF' L.D. NO.0 -7 - M.NO.- 1011W3 D BY BY Ce n tU Fir P t ti ry e ro ec o n In , c PAOJECT : NATASHA LERATI't•.BOUTIOUECFP VALENCIA BUILDING 6001 SW 70 STREET BAYS 105 & 106 SOUTH MIAMI, FLORIDA 33143 ' ; �V i S' PETERSBURG OFFICE KAIM OFFICE W5 South Pasadena Ave 82M KW. I4TH STREET St Peterdyju Florida 33707 I !Wok Florida 33126 1-868-322--TM 305-718-4486 305-7,� Fax 8r IM ND. 1 DAB 2/2/07 DRAM o CBS WAB AS SHOWN CBS MDF/SOUTH MIAMI 'U"LAt* 16 FP-1 OF 1 [-Cw--Nm _