07-105-006i UNIT NUMBER AHU1-1 .AREA SERVED SEE FL. PLAN Z TOTAL SUPPLY AIR CFM 1200 t OUTSIDE AIR CFM 2220 U- EXTERNAL STATIC PRESS. H 20 0.5 I FAN MOTOR HP/FLA 1/2 ELEC. CHAR. V/ , 208/10/60 COOL. COIL CAP. BTU HR 36,200 TOTAL SENS. HEAT BTU/HR I 26,400 o ENT. AIR TEMP. •F DB/'F WBI $0 67 " MODEL NUMBER UNIT MANUFACTURER RFIEEM MODEL NUMBER RBHK-21 i WEIGHT LBS. 126 REMARKS: REF. PIPING RS/RL AS PER MANUF. UNIT NUMBER CU-1 =' LOCATION SEE FL. PLAN CZ AMBIENT TEMP. 'F 95 w REFRIGERANT R 22 260MP./COND. FAN FLA 16,0 RLA 1.4 FLA o ELEC. CHAR. V p _, 240/10/60 i W MANUFACTURER MODEL NUMBER RHEE.4 RAMC-036jA WEIGHT LBS. REMARKS SEER/NOTES 245 13.6 z UNIT MTD. ELEC. HEAT CAP. 10.0 KW P' STEPS OF ELEC. HEAT N0. 1 I i ELEC. CHAR. V �►/, 208/10/60 _NOTES: 1. PROVIDE ALL AHU'S WITH 7 DAYS PROGRAMMABLE THERMOSTAT. 4 NQTES 0 AIR COOLED CONDW4SING UNIT • ANGLE VALVE FLEXIBLE CONNECTION +• AIR HANDLING UNIT SUCTION LINE ++ DX COIL * CF:;RGING VALVE "- THERMAL EXPANSION VALVE W/ s SLEEVES EXTERNAL E:UAUZER • LIOUID LINE Q DOUBT E PORT SIGHT GLASS Q DRIER a GLOBE VALVE 1 I+ ! PICA1 l REFLil. riRAN L" PIPING DIAG-14RANT1 NITS. PIPING DIAGRAM TYPICAL PER REFRIGERANT CIRCUIT FOR UNITS WITH MULTIPLE CIRCUITS, m NARROW WALL TYPE FIRE BARRIER 1/8" PER LINEAR FOOT CLEARENCE FOR EXPANSION AT TOP AND AT EACH VERTICAL SIDE RETAINING ANGLES SIZED ACCORDING TO "SMACNA" RECOMMENDATIONS FASTENED W/2-1/4" BOLTS,6" O.C. TO FD SLEEVE ONLY BLADES OUT OF AIR STREAM ELECTRIC -THERMAL MANUAL LINK FIRE DAMPER FRAME, FASTENED TO SLEEVE AS PER F.D. MANUFACTURER'S INSTRUCTION SHEET METAL DUCTWORK "S" SLIP TYPE CONNECTION 01141 TOP do BOTTOM AND DRIVE SLIP AT EA. SIDE STEEL PLATE SHALL OVERLAP MASONRY ! A MIN. OF 1" ALL AROUND OPENING I� DUCT ACCESS PANEL SHALL BE 16"x16",OR MAX. SIZE DUCT WILL ALLOW,LOCATED WITHIN 12" OF FIRE DAMPER'S LINK AND LABELED"FIRE DAMPER ACCESS" CONSTRUCTED IN ACCORDANCE W/SMACNA RECOMMENDATIONS, WIDE WALL TYPE FIRE BARRIER NOTES: APPLY NON -HARDENING SEALANT AT ALL JOINTS FOR AIR TIGHTNESS. IvFIG,AL F IFIE DAMPER nrl MEJAII N.T.S. FIRE DAMPERS SHALL BE U.L. CLASSIFIED DYNAMIC TYPE FIRE DAMPER i I DUCT IF AM 0%pw � i�i, UNIT NUMBER EF--1 AREAS SERVED BATH ROOM LOCATION CEILING DUTY SUPPLY/EXH. EXH. FAN TYPE CEILING FAN DRIVE BELT/DIRECT DIRECT FAN SPEED RPM AIR QUANTITY CFM 70 TOTAL STATIC PRESS. H 20 .123 OPENING REQUIRED IN. - FAN MOTOR ELECTRICAL CHAP,. V/-/- 115/1/60 MANUFACTURER BROAN MODEL NUMBER 671 WEIGHT LBS, Ric -MARKS SONES 3.0 N_ 1. FAN EF-1 SHALL BE INTERLOCKED TO LIGHT FIXTURES. 2. ALL FAIIIS SHALL BE PROVIDED WITH BACKDRAFT DAMPER INSULATED ROUND COLLAR W/ MANUAL VOLUME DAMPER I \� L DRAWBAND CONNECTOR BENEATH INSULATION DIFFUSER OR GRILLE INSULATED FLEXIBLE DUCT INSULATED ROUND COLLAR CEILING INSULATED SQUARE BOX DIFFUSER FOR SQUARE NECK���qq ROUE8U K DITH EDUCER IF TYPICAL CONNECTION TO AIR DIFFUSER N.T.S. j FLEXIBLE CONNECTION I SOUND INSULATED HOUSING AIR FLOW ADJUSTABLE EXHAUST DUCT MOUNTING I! CENTRIFUGAL FLANGE FAN INSIDE i HOUSING REMOVABLE ALUM. CEILING GRILLE AIR FLOW TYPICAL CEILING T 1TPE EXHAUST FAN DETAIL N.T.S. 1 /4" 0 STAINLESS STEE CABLE W/ PLASTIC CC BOLTED TO STEEL SUF FRAME W/ 3/8" BOLT TO WITHSTAND 150 MF HURRICANE FORCE WIC (TYPICAL) ROOFIP Ain niRTr-IM- i OIN wCHIE1ULE i1iiT i■7i� ■ ■ar SYMBOL jNECK SIZE MFGR, MODEL NUMBER REMARKS AD EE FL, PLA TITUS TDC t2024 MODULES? S/A DIF, O EE FL. PLAIN RUSKIN EME 6625D LOUVER k SEE FLR. PLAN TITUS SERIES DIFF S ER R/A GR, N❑TEST 1. REFER TO PLAN FOR QUANTITY, LOCATION AIR THROW PATTERN AND SIZES. 2, ALL AIR DISTRIBUTION DEVICES SHALL BE OF EXTRUDED ALUMINUM CONSTRUCTION, FURNISH WITH OPPOSED BLADE DAMPERS AND CONCEALED MOUNTING FRAME FOR ACOUSTICAL OR PLASTER CEILING INSTALLATION. .. 1iI LEGEND i m J!� jw! ■ wB 1lil.r Flw w 111 THERMOSTAT 7 ROOF MTD. E(H. FAN 0 DUCT SMOKE DETECTOR DUCT TURN DOWN = TRANSITION ! DUCT TURN UP ' TURNING VANE FLEXIBLE DUCT 45' BRANCH DUCT TAKE -OFF IZ N EXISTING SUPPLY i tfilr FIRE DAMPER 7-1H4R!ZONTAL L J EXISTIivG RETURN v.G. MANUAL VOLUME DAMPER - NEW SUPPLY �=- RETURN REGISTER L✓.JI NEW RETURN SUPPLY DIFFUSER S-.JI FIRE DAMPER RETURN AIR GRILLE VALVE - AIR FLOW DIRECTION NOTES: SUPPLY DUCT REFRIGERANT LINES AIR HANDING UNIT 24"MIN. NEOFHRENE PAD (FOUR CORNERS) RETURN DUCT FLEXIBLE CONNECTION FILTER FRAME WITH FILTER CONDENSATE DRAIN TRAP IT! FOR CONTINUATION SEE PLUMBING DRAWINGS. DISCONNECT SWITCH (SEE ELECT DWG.) ANGLE IRON FREE STANDING SUPPORT SECURE TO AHU THRU VIBRATION ISOLATORS AND TO FLOOR W/ BOLT. a . A 4'a: THRU BOLT UNIT TO STEEL FLOAT SWITCH ANGLE FRAME STAND WIRED IN SERIES THROUGH VIBRATION ISOLATION WITH T'STAT CIRCUIT AUXILIARY DRAIN PAN (GALVANIZED SHEET TO SHUT OFF UNIT 18 GA.) PROVIDE FLOAT SWITCH WIRED TO IN CASE OF AN OVERFILL STOP UNIT UPON OVERFLOW DETECTION. TO DRAIN PAN. AIR HANDLING UNTI IT 1140UNTING DETAIL N.T.S. CONDENSING UNIT BOLTED TO STEEL SUPPORT FRAME W/ 3/8" BOLTS TO WITHSTAND 150 MPH HURRICANE FORCE WINDS. (TYPICAL AT UNIT MOUNTING POINTS) VIBRATION ISOLATORS (TYP.) MIAMI-DADE COUNTY APPROVEL SUPPORT WELD FLASHING SEE DETAIL Yhr ELD INSULATION STL. PLATE THRU-BOLTS WITH NUTS CONC. SLAB MAINTAIN MFR'S RECOMMENDED CLEARANCES FOR AIRFLOW AND MAINTENANCE ACCESS 1 (2) 1/4"0 STAINLESS STEEL V/PLASTIC COVER %E;4 NIT Rr*j0WO- MOUE i Homm� DEE AIL N.T.S. NOTE: CONDENSING UNIT SUPPORT FRAME: SHALL BE AS MANUFACTURED BY PRECISION ALUMINUM PRODUCTS, INC., MIAMI-DADE COUNTY APPROVED NOA No. 02-051 4.02 ALUMINUM ALLOY CONSTRUCTION DENSING UNIT 1/4"0 STAINLESS STEEL CABLE W1 PLASTIC COVER BOLTED TO STEEL SUPPORT V/ FRAME W/ 3/8" BOLTS TO WITHSTAND 150 MPH HURRICANE FORCE WINDS. (TYPICAL) ROOF MOUNTED EQUIPMENT HEIGHT REQUIREMENTS WIDTH OF EQUIPMENT HEIGHT OF LEGS (INCHES) (INCHES) UP TO 24 14 25 TO 36 18 37 TO 48 24 49 TO 60 30 61 AND WIDER a.8 Y•r• ••• • • ♦C`�•• ••r HVrA��G �Nwea�FISHa�■waarAaL N■e.rt ar!m ■ aasLri 1. CONTRACTOR SHALL COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO • • • • • • ` ORDERING AND/OR INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. u Y • I .•. Y.. 2, THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT PERMITS, FEES, INSPECTIONS, TESTS, INSURANCE, ETC., REQUIRED FOR THE : • • • • • : .I COMPLETION OF THE AIR CONDITIONING, 'HEATING AND VENTILATION ;"'r «' I SYSTEMS SHOWN ON "DRAWINGS OR LISTED BELOW. • , • rI 3. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW EVERY MEND, OFF -SET, ELMOWS OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED, OR FOR COORDINATION WITH OTHER TRADES. 4. DRAWINGS ARE NOT TO BE SCALED. !UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS, AND SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF MECHANICAL EQUIPMENT AND APPURTENANCES. I 5. VERIFY ALL SPACE CONDITIONS is DIMENSIONS AT JOW SITE PRIOR TO FABRICATION OF DUCTWORK AND INSTALLATION OF EQUIPMENT AND ACCESSORIES. I 6 A BALANCING CONTRACTOR SHALL ADJUST AND BALANCE AIR DISTRIBU- TION DEVICES IN ACCORDANCE WITH QUANTITIES SHOWN ON PLANS FOR REGULAR HVAC OPERATION AND FOR REQUIRED BUILDING PRESSURIZATION I REQUIREMENTS. 7. CONTRACTORS ALL COORDINATE WITH TENANT SO TkAT ANY EQUIPMENT OR DEVICE TO REMAIN THAT MAY HAVE TO BE DISCONNECTED MECAUSE OF THE REMOVAL OF ANY OTHER DEVICE IS RECONNECTED AND TIED BACK TO THE EXISTING BUILDING SYSTEM(S) AND TESTED FOR CORRECT OPERATION. ;. ANY WORK NOT SHOWN ON DRAWINGS OR SPECIFICALLY MENTIONED IN f THE HVAC NOTES BUT CONSIDERED NECESSARY FOR THE COMPLETION OF THE WORK IN PROPER MANNER SHALL BE PROVIDED BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGE. 11 9. COORDINATE SPACE ACCESSIBILITY AND WORKING HOURS REQUIREMENTS WITH OWNER'S REPRESENTATIVE PRIOR TO BIDDING THIS PROJECT. OTHER AREAS IN THIS OR ADJACENT SPACES MAY HAVE SPECIAL REQUIREMENTS FOR ACCESSIBILITY TO EXISTING BUILDING SYSTEMS PRESENTLY IN THEIR SPACES BUT WHICH, MAY NEED TO BE ACCESSED FOR THIS PROJECT. N 10, CONTRACTOR SHALL DO HIS OWN CUTTING AND REMOVAL OF ALL HIS RELATED WORK IN ALL LOCATIONS WHERE REQUIRED EXCEPT WHERE OTHERWISE SHOWN ON THE DRAWINGS AND/OR AS SPECIFIED AND/OR AS COORDINATED WITH TENANTS, 11, ALL BUILDING CONSTRUCTION AFFECTEDL THE REMOVAL, RELOCATION, INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL B€ REPAIRED AND REFINISHED AS REQUIRED TO MATCH EXISTING CONDITIONS OR AS DIRECTED BY THE ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS. 12. DUCTWORK: I A. VENTILATION DUCTWORK SHALL DE GALVANIZED STEEL WITH GAUGES, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE A.S.H.R.A.E. GUIDE AND S.M.A.C.N.A. STANDARDS. DUCT SIZES SHOWN ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH RESPECT To STRUCTURE BEFORE FABRICATION. ! I'?. AIR CONDI IONING SUPPLY AND RETURN DUCTWORK SHALL BE 1-1/2" (R=G Ml"L) FIBERGLASS U.L. 181 LISTED, CLASS I AIR. DUCT. DUCTIAIORK SHALL BE FABRICATED IN�ACCORDANCE :".ITN S.M.A,C.N,A, STANDARDS. C. FLEXIBLE DUCT SHALL BE STEEL HELIX WIRE ON 7/8" CENTERS, ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED MY MOLECULAR WELDING TO FORM AN AIR TIGHT INNER CORE, THE CORE IS TO BE INSULATED WITH FIBERGLASS INSULATION (R-6), AND SHEATHED IN A REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET, PROVIDE SPIN COLLAR WITH DAMPER'iAND EXTRACTOR WHERE FLEXIBLE DUCT IS CONNECTED TO RECTANGULAR DUCTWORK. DAMPER ACTUATOR SHALL WE EXTENDED OUTSIDE INSULATION. 13. AIR DISTRIBUTION: A. SUPPLY AND RETURN AIR DIFFUSERS 'SHALL :E OF EXTRUDED EXTRUDED ALUMINUM CONSTRUCTION 11OR AS SPECIFIED. 14. PROVIDE ACCESS PANELS IN WALLS OR CEILING FOR DAMPERS, CONTROL DEVICES, ETC. ACCESS PANELS SHALL WE MILCOR FLUSH TYPE. COORDINATE LOCATION WITH ARCHITECT.' 15. SUBMIT SHOP DRAWINGS OF ALL MATERIALS, DUCTWORK AND EQUIPMENT FOR REVIEW PRIOR INSTALLATION AND/OR FABRICATION. 16. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR THE PERIOD OF ONE YEAR. PERIOD OF GUARANTEE SHALL COMMENCE i UPON RECEIPT OF CERTIFICATE OF OCCUPANCY. 17. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 FLORIDA BUILDING CODE 18. SUMMIT A COMPLETE 'AS --BUILT" RECORD SET IN REPRODUCIBLE PAPER SEPIA FORM TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FINAL PAYMENT REQUISITION. 19. TESTING: A. BALANCE AIR SYSTEM TO DELIVER S FCIFIED AIR QUANTITIES AT EACH OUTLET WITHIN 10% USING A.A.M.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST, RESULTS FOR REVIEW PRIOR TO FINAL INSPECTION AND ACCEPTANCE. 20. ALL HVAC EQUIPMENT, AIR DISTRiGUTiON, CONTROLS, APPURTENANCES, ETC. SHALL BE AS SHOWN ON THE DRAWINGS` WITH RESPECT TO CAPACITY,QUALITY PERFORMANCE,ACCESSORIES,ETC.MANUFACTURERS USED FOR THE BASIS OF DESIGN ARE LISTED ON THE DRAWINGS SCHEDULES OR SPECIFIED HEREIN. SUBSTITUTIONS MUST MEET OR EXCEED ALL SPECIFIED REQUIREMENTS. NAMING ACCEPTABLE MANUFACTURERS DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH ALL DESIGN REQUIREMENTS SHOWN ON THE DRAWINGS OR LISTED HEREIN, 21. ALL INSULATION PRODUCTS AND ACCESSORIES SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR LESS IN ACCORDANCE WITH ASTM E84. 22. SUBMIT SHOP DRALIIING OF ALL MATERIA 8 AND EQUIPMENT FOR APPROVAL PRIOR TO FABRICATION. 23. TEMPERATURE CONTROL SHALL ME A PROGRAMMABLE ROOM THERMOSTAT FOR HEATING/COOLING WITH STAGES AS REQUIRED. 24. VIGRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD. 'I 25. GUARANTEES: A. ALL COMPRESSOR MOTORS ON NEW, EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL HAVE A MIN. 5 YEARS PRODUCT GUARANTEE FROM DATE OF START-UP. B. CONTRACTOR SHALL GUARANTEE AL11 MATERIALS AND WORMIANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN A 1 YEAR FROM DATE OF ACCEPTANCE. 26. TESTING: ! A. ALL REFRIGERANT HIGH SIDE PIPING TO 300 PS!G. LOW SIDE TO 150 PSIG. AFTER TESTING, EVACUATE SYSTEM TO 28% iI MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 25 HOURS WITH PUMP OFF. MREAK VACUUM WITH REFRIGERANT. 27. ALL CONDENSATE PIPING SHALL BE COPPI[R DWV, INSULATE COND. PIPES ABOVE GROUND WITH 3/4 INCH ARMAFLEX INSULATION. Certificate OFF Authorization #9692 Jose M. Martinez, P.E. #56018 12651 South Dixie PR Sluit2 269 'T UL, (305) 255-1621 Miami, Florida 33156 FAX (305) 255-1732 TO THE TEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING, CODES. THIS DRAWNG IS THE SOLE PROPERTY OF 'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO DE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF JMM CONSULTING LNGINNERS, LLC. cm i cm 0 �i K +i ", w 1111. aS II rw� � �+■ II G� No" ca �,,,■,., � � � tom] Sia-III G ■ iI 100 li Cb ..,�w fie !n IV) 0 _ N t .� "• i. IM tii rum- 1 C p i w tii� �- til LM wo Z P v Vim t;s I Z F3 r_ '� w raar•r ,.., ! C � 1 I 1 see• rmftn sm owP, 04 E .�. I� IN 0 L NQJ - i 1 V l-22--•Li7 ! 11AI? = f II LPA116 A�.: J � FOR am DW* No . luj-/ Or'