07-105-006i UNIT NUMBER
AHU1-1
.AREA SERVED
SEE FL. PLAN
Z
TOTAL SUPPLY AIR CFM
1200
t
OUTSIDE AIR CFM
2220
U-
EXTERNAL STATIC PRESS. H 20
0.5
I FAN MOTOR HP/FLA
1/2
ELEC. CHAR. V/ ,
208/10/60
COOL. COIL CAP. BTU HR
36,200
TOTAL SENS. HEAT BTU/HR
I 26,400
o
ENT. AIR TEMP. •F DB/'F WBI
$0 67
"
MODEL NUMBER
UNIT MANUFACTURER
RFIEEM
MODEL NUMBER
RBHK-21
i
WEIGHT LBS.
126
REMARKS: REF. PIPING RS/RL
AS PER MANUF.
UNIT NUMBER
CU-1
='
LOCATION
SEE FL. PLAN
CZ
AMBIENT TEMP. 'F
95
w
REFRIGERANT R
22
260MP./COND.
FAN FLA
16,0 RLA 1.4 FLA
o
ELEC. CHAR. V p _,
240/10/60 i
W
MANUFACTURER
MODEL NUMBER
RHEE.4
RAMC-036jA
WEIGHT LBS.
REMARKS SEER/NOTES
245
13.6
z
UNIT MTD. ELEC. HEAT CAP.
10.0 KW
P'
STEPS OF ELEC. HEAT N0.
1 I
i
ELEC. CHAR. V �►/,
208/10/60
_NOTES:
1. PROVIDE ALL AHU'S WITH 7 DAYS PROGRAMMABLE THERMOSTAT.
4
NQTES
0 AIR COOLED CONDW4SING UNIT • ANGLE VALVE
FLEXIBLE CONNECTION +• AIR HANDLING UNIT
SUCTION LINE ++ DX COIL
* CF:;RGING VALVE
"- THERMAL EXPANSION VALVE W/
s SLEEVES EXTERNAL E:UAUZER
• LIOUID LINE Q DOUBT E PORT SIGHT GLASS
Q DRIER
a GLOBE VALVE 1
I+ ! PICA1 l REFLil. riRAN L" PIPING DIAG-14RANT1
NITS.
PIPING DIAGRAM TYPICAL PER REFRIGERANT CIRCUIT FOR UNITS WITH
MULTIPLE CIRCUITS,
m
NARROW WALL TYPE
FIRE BARRIER
1/8" PER LINEAR FOOT CLEARENCE FOR
EXPANSION AT TOP AND AT EACH VERTICAL
SIDE
RETAINING ANGLES SIZED ACCORDING TO
"SMACNA" RECOMMENDATIONS FASTENED
W/2-1/4" BOLTS,6" O.C. TO FD SLEEVE
ONLY
BLADES OUT OF AIR STREAM
ELECTRIC -THERMAL MANUAL LINK
FIRE DAMPER FRAME, FASTENED TO SLEEVE AS
PER F.D. MANUFACTURER'S INSTRUCTION
SHEET METAL DUCTWORK
"S" SLIP TYPE CONNECTION 01141 TOP do
BOTTOM AND DRIVE SLIP AT EA. SIDE
STEEL PLATE SHALL OVERLAP MASONRY
! A MIN. OF 1" ALL AROUND OPENING
I�
DUCT ACCESS PANEL SHALL BE 16"x16",OR MAX. SIZE
DUCT WILL ALLOW,LOCATED WITHIN 12" OF FIRE DAMPER'S
LINK AND LABELED"FIRE DAMPER ACCESS" CONSTRUCTED
IN ACCORDANCE W/SMACNA RECOMMENDATIONS,
WIDE WALL TYPE FIRE BARRIER
NOTES:
APPLY NON -HARDENING SEALANT AT ALL
JOINTS FOR AIR TIGHTNESS.
IvFIG,AL F IFIE DAMPER
nrl
MEJAII
N.T.S.
FIRE DAMPERS SHALL BE U.L. CLASSIFIED
DYNAMIC TYPE FIRE DAMPER
i
I
DUCT
IF AM 0%pw � i�i,
UNIT NUMBER
EF--1
AREAS SERVED
BATH
ROOM
LOCATION
CEILING
DUTY SUPPLY/EXH.
EXH.
FAN TYPE
CEILING FAN
DRIVE BELT/DIRECT
DIRECT
FAN SPEED RPM
AIR QUANTITY CFM
70
TOTAL STATIC PRESS. H 20
.123
OPENING REQUIRED IN.
-
FAN MOTOR
ELECTRICAL CHAP,. V/-/-
115/1/60
MANUFACTURER
BROAN
MODEL NUMBER
671
WEIGHT LBS,
Ric -MARKS SONES
3.0
N_
1. FAN EF-1 SHALL BE INTERLOCKED TO LIGHT FIXTURES.
2. ALL FAIIIS SHALL BE PROVIDED WITH BACKDRAFT DAMPER
INSULATED ROUND
COLLAR W/
MANUAL VOLUME DAMPER
I
\� L
DRAWBAND
CONNECTOR
BENEATH INSULATION
DIFFUSER OR
GRILLE
INSULATED FLEXIBLE DUCT
INSULATED ROUND
COLLAR
CEILING
INSULATED SQUARE BOX
DIFFUSER
FOR SQUARE NECK���qq
ROUE8U K DITH EDUCER
IF
TYPICAL CONNECTION TO AIR DIFFUSER
N.T.S.
j FLEXIBLE
CONNECTION
I
SOUND INSULATED HOUSING AIR FLOW
ADJUSTABLE EXHAUST DUCT
MOUNTING I! CENTRIFUGAL
FLANGE FAN INSIDE
i HOUSING
REMOVABLE
ALUM. CEILING GRILLE AIR FLOW
TYPICAL CEILING T 1TPE EXHAUST FAN DETAIL
N.T.S.
1 /4" 0 STAINLESS STEE
CABLE W/ PLASTIC CC
BOLTED TO STEEL SUF
FRAME W/ 3/8" BOLT
TO WITHSTAND 150 MF
HURRICANE FORCE WIC
(TYPICAL)
ROOFIP
Ain niRTr-IM- i OIN wCHIE1ULE
i1iiT i■7i� ■ ■ar
SYMBOL
jNECK SIZE
MFGR,
MODEL NUMBER
REMARKS
AD
EE FL, PLA
TITUS
TDC t2024 MODULES?
S/A DIF,
O
EE FL. PLAIN
RUSKIN
EME 6625D
LOUVER
k
SEE FLR. PLAN
TITUS
SERIES DIFF S ER
R/A GR,
N❑TEST
1. REFER TO PLAN FOR QUANTITY, LOCATION AIR THROW
PATTERN AND SIZES.
2, ALL AIR DISTRIBUTION DEVICES SHALL BE OF EXTRUDED
ALUMINUM CONSTRUCTION, FURNISH WITH OPPOSED
BLADE DAMPERS AND CONCEALED MOUNTING FRAME
FOR ACOUSTICAL OR PLASTER CEILING INSTALLATION.
.. 1iI LEGEND i
m J!� jw! ■ wB 1lil.r Flw w 111
THERMOSTAT
7
ROOF MTD. E(H. FAN
0
DUCT SMOKE DETECTOR
DUCT TURN DOWN =
TRANSITION
!
DUCT TURN UP
'
TURNING VANE
FLEXIBLE DUCT
45' BRANCH DUCT TAKE -OFF
IZ N
EXISTING SUPPLY i
tfilr
FIRE DAMPER
7-1H4R!ZONTAL
L J
EXISTIivG RETURN
v.G.
MANUAL VOLUME DAMPER
-
NEW SUPPLY
�=-
RETURN REGISTER
L✓.JI
NEW RETURN
SUPPLY DIFFUSER
S-.JI
FIRE DAMPER
RETURN AIR GRILLE
VALVE
-
AIR FLOW DIRECTION
NOTES:
SUPPLY DUCT
REFRIGERANT
LINES
AIR HANDING
UNIT
24"MIN.
NEOFHRENE PAD
(FOUR CORNERS)
RETURN DUCT
FLEXIBLE
CONNECTION
FILTER FRAME
WITH FILTER
CONDENSATE DRAIN TRAP
IT! FOR CONTINUATION SEE
PLUMBING DRAWINGS.
DISCONNECT SWITCH
(SEE ELECT DWG.)
ANGLE IRON FREE STANDING
SUPPORT SECURE TO AHU THRU
VIBRATION ISOLATORS AND TO
FLOOR W/ BOLT.
a .
A 4'a:
THRU BOLT UNIT TO STEEL FLOAT SWITCH
ANGLE FRAME STAND WIRED IN SERIES
THROUGH VIBRATION ISOLATION WITH T'STAT CIRCUIT
AUXILIARY DRAIN PAN (GALVANIZED SHEET TO SHUT OFF UNIT
18 GA.) PROVIDE FLOAT SWITCH WIRED TO IN CASE OF AN OVERFILL
STOP UNIT UPON OVERFLOW DETECTION. TO DRAIN PAN.
AIR HANDLING UNTI
IT 1140UNTING DETAIL
N.T.S.
CONDENSING UNIT
BOLTED TO STEEL SUPPORT
FRAME W/ 3/8" BOLTS
TO WITHSTAND 150 MPH
HURRICANE FORCE WINDS.
(TYPICAL AT UNIT MOUNTING POINTS)
VIBRATION ISOLATORS (TYP.)
MIAMI-DADE COUNTY APPROVEL
SUPPORT
WELD
FLASHING SEE DETAIL
Yhr ELD
INSULATION
STL. PLATE
THRU-BOLTS WITH NUTS
CONC. SLAB
MAINTAIN MFR'S RECOMMENDED
CLEARANCES FOR AIRFLOW AND
MAINTENANCE ACCESS
1 (2) 1/4"0 STAINLESS STEEL
V/PLASTIC COVER
%E;4 NIT Rr*j0WO-
MOUE i Homm� DEE AIL
N.T.S.
NOTE:
CONDENSING UNIT SUPPORT FRAME: SHALL BE AS MANUFACTURED BY
PRECISION ALUMINUM PRODUCTS, INC., MIAMI-DADE COUNTY APPROVED
NOA No. 02-051 4.02 ALUMINUM ALLOY CONSTRUCTION
DENSING UNIT
1/4"0 STAINLESS STEEL
CABLE W1 PLASTIC COVER
BOLTED TO STEEL SUPPORT V/
FRAME W/ 3/8" BOLTS
TO WITHSTAND 150 MPH
HURRICANE FORCE WINDS.
(TYPICAL)
ROOF MOUNTED EQUIPMENT HEIGHT REQUIREMENTS
WIDTH OF EQUIPMENT HEIGHT OF LEGS
(INCHES) (INCHES)
UP TO 24 14
25 TO 36 18
37 TO 48 24
49 TO 60 30
61 AND WIDER a.8
Y•r• ••• • • ♦C`�•• ••r
HVrA��G �Nwea�FISHa�■waarAaL N■e.rt ar!m ■ aasLri
1. CONTRACTOR SHALL COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO • • • • • • `
ORDERING AND/OR INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. u Y •
I .•. Y..
2, THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE
FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT PERMITS,
FEES, INSPECTIONS, TESTS, INSURANCE, ETC., REQUIRED FOR THE : • • • • • : .I
COMPLETION OF THE AIR CONDITIONING, 'HEATING AND VENTILATION ;"'r «' I
SYSTEMS SHOWN ON "DRAWINGS OR LISTED BELOW. • , • rI
3. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW
EVERY MEND, OFF -SET, ELMOWS OR OTHER FITTINGS WHICH MAY BE
REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED, OR
FOR COORDINATION WITH OTHER TRADES.
4. DRAWINGS ARE NOT TO BE SCALED. !UNLESS SPECIFIC
DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND/OR STRUCTURAL
DRAWINGS, AND SITE CONDITIONS SHALL GOVERN EXACT
LOCATION OF MECHANICAL EQUIPMENT AND APPURTENANCES.
I
5. VERIFY ALL SPACE CONDITIONS is DIMENSIONS AT JOW SITE PRIOR TO
FABRICATION OF DUCTWORK AND INSTALLATION OF EQUIPMENT AND
ACCESSORIES. I
6 A BALANCING CONTRACTOR SHALL ADJUST AND BALANCE AIR DISTRIBU-
TION DEVICES IN ACCORDANCE WITH QUANTITIES SHOWN ON PLANS FOR
REGULAR HVAC OPERATION AND FOR REQUIRED BUILDING PRESSURIZATION I
REQUIREMENTS.
7. CONTRACTORS ALL COORDINATE WITH TENANT SO TkAT
ANY EQUIPMENT OR DEVICE TO REMAIN THAT MAY HAVE TO BE
DISCONNECTED MECAUSE OF THE REMOVAL OF ANY OTHER DEVICE
IS RECONNECTED AND TIED BACK TO THE EXISTING BUILDING
SYSTEM(S) AND TESTED FOR CORRECT OPERATION.
;. ANY WORK NOT SHOWN ON DRAWINGS OR SPECIFICALLY MENTIONED IN
f
THE HVAC NOTES BUT CONSIDERED NECESSARY FOR THE COMPLETION
OF THE WORK IN PROPER MANNER SHALL BE PROVIDED BY THE
CONTRACTOR WITHOUT ADDITIONAL CHARGE.
11
9. COORDINATE SPACE ACCESSIBILITY AND WORKING HOURS REQUIREMENTS
WITH OWNER'S REPRESENTATIVE PRIOR TO BIDDING THIS PROJECT.
OTHER AREAS IN THIS OR ADJACENT SPACES MAY HAVE SPECIAL
REQUIREMENTS FOR ACCESSIBILITY TO EXISTING BUILDING SYSTEMS
PRESENTLY IN THEIR SPACES BUT WHICH, MAY NEED TO BE ACCESSED
FOR THIS PROJECT. N
10, CONTRACTOR SHALL DO HIS OWN CUTTING AND REMOVAL OF ALL HIS
RELATED WORK IN ALL LOCATIONS WHERE REQUIRED EXCEPT WHERE
OTHERWISE SHOWN ON THE DRAWINGS AND/OR AS SPECIFIED AND/OR
AS COORDINATED WITH TENANTS,
11, ALL BUILDING CONSTRUCTION AFFECTEDL THE REMOVAL, RELOCATION,
INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL B€ REPAIRED AND
REFINISHED AS REQUIRED TO MATCH EXISTING CONDITIONS OR AS
DIRECTED BY THE ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS.
12. DUCTWORK: I
A. VENTILATION DUCTWORK SHALL DE GALVANIZED STEEL WITH GAUGES,
DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH
THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE
A.S.H.R.A.E. GUIDE AND S.M.A.C.N.A. STANDARDS. DUCT SIZES SHOWN
ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH
RESPECT To STRUCTURE BEFORE FABRICATION.
!
I'?. AIR CONDI IONING SUPPLY AND RETURN DUCTWORK SHALL BE 1-1/2"
(R=G Ml"L) FIBERGLASS U.L. 181 LISTED, CLASS I AIR. DUCT.
DUCTIAIORK SHALL BE FABRICATED IN�ACCORDANCE :".ITN S.M.A,C.N,A,
STANDARDS.
C. FLEXIBLE DUCT SHALL BE STEEL HELIX WIRE ON 7/8" CENTERS,
ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED MY MOLECULAR
WELDING TO FORM AN AIR TIGHT INNER CORE, THE CORE IS TO BE
INSULATED WITH FIBERGLASS INSULATION (R-6), AND SHEATHED IN A
REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET,
PROVIDE SPIN COLLAR WITH DAMPER'iAND EXTRACTOR WHERE FLEXIBLE
DUCT IS CONNECTED TO RECTANGULAR DUCTWORK. DAMPER ACTUATOR
SHALL WE EXTENDED OUTSIDE INSULATION.
13. AIR DISTRIBUTION:
A. SUPPLY AND RETURN AIR DIFFUSERS 'SHALL :E OF EXTRUDED
EXTRUDED ALUMINUM CONSTRUCTION 11OR AS SPECIFIED.
14. PROVIDE ACCESS PANELS IN WALLS OR CEILING FOR DAMPERS, CONTROL
DEVICES, ETC. ACCESS PANELS SHALL WE MILCOR FLUSH TYPE.
COORDINATE LOCATION WITH ARCHITECT.'
15. SUBMIT SHOP DRAWINGS OF ALL MATERIALS, DUCTWORK AND EQUIPMENT
FOR REVIEW PRIOR INSTALLATION AND/OR FABRICATION.
16. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR THE
PERIOD OF ONE YEAR. PERIOD OF GUARANTEE SHALL COMMENCE i
UPON RECEIPT OF CERTIFICATE OF OCCUPANCY.
17. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 FLORIDA
BUILDING CODE
18. SUMMIT A COMPLETE 'AS --BUILT" RECORD SET IN REPRODUCIBLE PAPER
SEPIA FORM TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FINAL
PAYMENT REQUISITION.
19. TESTING:
A. BALANCE AIR SYSTEM TO DELIVER S FCIFIED AIR QUANTITIES AT
EACH OUTLET WITHIN 10% USING A.A.M.C. PROCEDURES AND
TESTS. SUBMIT AIR BALANCE TEST, RESULTS FOR REVIEW PRIOR
TO FINAL INSPECTION AND ACCEPTANCE.
20. ALL HVAC EQUIPMENT, AIR DISTRiGUTiON, CONTROLS, APPURTENANCES, ETC.
SHALL BE AS SHOWN ON THE DRAWINGS` WITH RESPECT TO CAPACITY,QUALITY
PERFORMANCE,ACCESSORIES,ETC.MANUFACTURERS USED FOR THE BASIS OF
DESIGN ARE LISTED ON THE DRAWINGS SCHEDULES OR SPECIFIED HEREIN.
SUBSTITUTIONS MUST MEET OR EXCEED ALL SPECIFIED REQUIREMENTS.
NAMING ACCEPTABLE MANUFACTURERS DOES NOT RELIEVE THE CONTRACTOR
FROM COMPLIANCE WITH ALL DESIGN REQUIREMENTS SHOWN ON THE
DRAWINGS OR LISTED HEREIN,
21. ALL INSULATION PRODUCTS AND ACCESSORIES SHALL HAVE A FLAME SPREAD
RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR
LESS IN ACCORDANCE WITH ASTM E84.
22. SUBMIT SHOP DRALIIING OF ALL MATERIA 8 AND EQUIPMENT FOR
APPROVAL PRIOR TO FABRICATION.
23. TEMPERATURE CONTROL SHALL ME A PROGRAMMABLE ROOM THERMOSTAT FOR
HEATING/COOLING WITH STAGES AS REQUIRED.
24. VIGRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER
RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING
HEARD. 'I
25. GUARANTEES:
A. ALL COMPRESSOR MOTORS ON NEW, EQUIPMENT FURNISHED UNDER
THIS CONTRACT SHALL HAVE A MIN. 5 YEARS PRODUCT GUARANTEE FROM
DATE OF START-UP.
B. CONTRACTOR SHALL GUARANTEE AL11 MATERIALS AND WORMIANSHIP
FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN A 1 YEAR
FROM DATE OF ACCEPTANCE.
26. TESTING: !
A. ALL REFRIGERANT HIGH SIDE PIPING TO 300 PS!G. LOW SIDE
TO 150 PSIG. AFTER TESTING, EVACUATE SYSTEM TO 28% iI
MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 25
HOURS WITH PUMP OFF. MREAK VACUUM WITH REFRIGERANT.
27. ALL CONDENSATE PIPING SHALL BE COPPI[R DWV, INSULATE COND. PIPES
ABOVE GROUND WITH 3/4 INCH ARMAFLEX INSULATION.
Certificate OFF Authorization #9692
Jose M. Martinez, P.E. #56018
12651 South Dixie PR Sluit2 269 'T UL, (305) 255-1621
Miami, Florida 33156 FAX (305) 255-1732
TO THE TEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED
HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE
APPLICABLE BUILDING, CODES. THIS DRAWNG IS THE SOLE PROPERTY OF
'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO DE
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION
OF JMM CONSULTING LNGINNERS, LLC.
cm
i
cm
0
�i
K
+i
",
w
1111.
aS
II rw�
�
�+■ II
G�
No"
ca
�,,,■,.,
� � �
tom]
Sia-III
G
■
iI
100
li
Cb
..,�w
fie !n
IV)
0
_
N
t
.�
"•
i.
IM
tii
rum- 1
C p i w
tii�
�- til
LM
wo
Z P
v
Vim
t;s
I
Z
F3
r_
'�
w
raar•r
,..,
!
C �
1
I
1
see•
rmftn
sm
owP,
04
E
.�.
I�
IN
0
L
NQJ
-
i 1
V l-22--•Li7 ! 11AI? = f
II
LPA116 A�.: J � FOR am
DW* No .
luj-/ Or'