Loading...
06-1948-008NUT _VIS HANI PIPE O.0 ULATION PIPE NSULATIO ADDLE .� v. SHIELD PIPE W/ INSULATION Pl.UM15ING LEGEND SYMBOL DESCRIPTION SANITARY WASTE PIPING - COLD WAt1=R PIPING C W) - - - - - SANITARY VENT PIPING _CD_ CONDENSATE DRAIN PIPING SD - STORM DRAIN PIPING OSD-- OVERFLOW STORM DRAIN PIPING RWL RAIN WATER LEADER ORWL OVERFLOW RAIN WATER LEADER fl4-- GATE VALVE fZ4__ CHECK VALVE �-- "PIT TRAP -�• HB HOSE BIBS (HIB) WATER HAMMER ARRESTOR VTR VENT THRU ROOF CO CLEAN OUT FCO FLUSH FLOOR CLEAN OUT W P� FLOOR DRAIN WITH TRAP PRIMER COOL CLEAN OUT ON GRADE FD FLOOR DRAIN V VENT j' TRAP PRIMER (RESEAL) TO CLOSEST FIXTURE 0 RD ROOF DRAIN 0 ORD OVERFLOW ROOF DRAIN FOS- FUEL OIL SUPPLY PIPING FOR- FUEL OIL RETURN PIPING NOTE: SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS (NOT TO SCALE) PIPE W/OUT INSULATION el re'1 rr11'1ATI�1'1 \/rA1T r%Arl TEST TEE THREADEC CLEANOUT PIPE HAINQERS-CLEVIS TYPE DETAIL N.T.S. A/C U N IT 1 C--- ALL CLEANCUT (NOT TO SCALE) PLUMBING GENERAL NOTES A. UNLESS OTHERWISE SPECIFIED ON THIS DRAWING CONTRACTOR SHALL REFER TO ORIGINAL LANDLORD SPECIFICATIONS FOR ALL APPLICABLE REQUIREMENTS, NOTES, DETAILS, CONSTRUCTION'S STANDARDS, ETC., COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO ORDERING AND/OR INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. 1. SITE INVESTIGATION: EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK; THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF/HERSELF WITH THE NATURE AND EXTEND OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEM AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, EXISTING FACILITIES AND ALL BUILDING STRUCTURES TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. VARIATIONS IN ROUTING AND/OR CONSTRUCTION SHOULD BE ANTICIPATED BY THIS CONTRACTOR AND ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATION AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. 2. THE NATURE OF THE REMODEL TYPE CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEERS AS WELL AS THE PLUMBING CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEERS TO SHOW AND IDENTIFY THE LOCATIONS AND TYPES OF EXISTING PLUMBING SYSTEMS. THE MAJOR PORTION OF THE PLUMBING SYSTEMS ARE AS SHOWN ON THE DRAWINGS HOWEVER DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. PLUMBING CONTRACTOR SHALL PERFORM A FIELD VERIFICATION BEFORE BIDDING THIS PROJECT. 3. CONTRACTOR WILL BE RESPONSIBLE FOR COODINATING HIS DEMOLITION WORK WITH OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING SYSTEMS TO REMAIN. 4. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING PIPES BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. 5. ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WALLS, CHASES OR PARTITIONS. 6. EXISTING PIPES SERVING AREAS NOT COVERED BY THIS CONTRACT BUT IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED EXCEPT AS A TEMPORARY INTERRUPTION COORDINATED WITH THE OWNER AND LANDLORD. 7. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 8. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 9. COORDINATE ALL WORK WITH OTHER TRADES. 10. PLUMBING CONTRACTOR SHALL GUARANTEE ALL. WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 11. PROVIDE SHOCK ABSORBERS SIZE, QUANTITY AND LOCATION AS PER P.D.I. STANDARDS. 12. PROVIDE SHUT-OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH FIXTURE SUPPLY. 13. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL. BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 14. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH -INS WITH THE MANUFACTURER BEFORE MAKING ANY INSTALLATION. 15. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE "LEAD FREE" WITH LEAD CONTENT NOT EXCEEDING 0.2 PERCENT FOR SOLDER AND FLUXES AND 8 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. CONTRACTOR SHALL VERIFY MANUFACTURER'S COMPLIANCE. 16. ALL. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE FLUSHED CLEAR, STERILIZED WITH AN APPROVED SOLUTION AND THROUGHLY FLUShED OF ALL RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND CONNECTIONS INSTALLED. 17. PROVIDE SHUT-OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE -END CONNECTIONS. 18. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 19. PVC PIPING IS NOT ALLOWED IN RETURN AIR PLENUMS. IF RETURN AIR PLENUMS ARE USED, CONTRACTOR SHALL REPLACE ALL EXISTING PVC PIPING WITH CAST IRON OR COPPER PIPING. 20. DRAINAGE SYSTEM DESIGN IS BASED ON 1/8" PER FOOT MINIMUM FALL FOR PIPES 3' OR LARGER AND 1/4" PER FOOT MINIMUM FALL FOR PIPES 2' OR SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT/ENGINEER. 21. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFFSETED TO A MINIMUM DISTANCE OF 3'-0' FROM PARRAPET WALL OR ROOF EDGE. SEE ARCHITECTURAL DRAWINGS FOR ROOF FLASHING. LEAD FLASHING WILL NOT BE ACCEPTED. 22. DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED WITH PRE -MANUFACTURED SLEEVE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 404.6.4. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. ACCESS COVER AND FRAME FINISHED WALL SURFACE UL FIRE RESISTANCE DIRECTORY: A FILLS, VOIDS OR CAVITY MATERIALS (XHH%V) B. FIRESTOP DEVICES (XHJI) UL1479 UL2079 PLUMBING SPECIFICATION 1. GENERAL: MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBLICATIONS IN FORCE AT TIME OF BIDDING. 2. PIPE AND FITTINGS: A. DRAINAGE WASTE ANC) VENT PIPING INCLUDING: PVC DRAINAGE WASTE AND PIPING (DWV) CONFORMING TO ASTM D-2665, UNDERGROUND NO HHUB CAST IRON CISPI STANDARD 301 ABOVE GROUND AND CASiT IRON HUB, PLAIN END ASTM A-74 WITH NEO- PRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN ITS APPROVED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR RETURN PLENUM. B. DOMESTIC WATER SUPPLY PIPING: COPPER PIPE TYPE 'L' WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM.B88-78. C. CONDENSATE PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. D. STORM DRAIN PIPING:: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. 3. JOINTS AND METHODS OF CONNECTION: A. OW COPPER PIPE: JOINT WITH 95-5 TIN -ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. B. TYPE 'L' COPPE:R TUBE: JOIN WITH 95-5 TIN -ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. C. STEEL PIPE: a. THREADED JOINITS: AFTER CUTTING AND BEFORE THREADING, REAM ALL PIPE AND REMOVE BIURRS. MAKE JOINTS WITH JOINT COMPOUND APPLIED TO MALE THREADS ONLY. b. FLANGED JOINTS: STANDARD WEIGHT, 150 P.S.I. STEEL, WITH APPROVED RED RUBBER GASKET OR NEOPRENE RUBBER GASKET, INSTALL AS PER MANUFACTURER'S RECOMWENDATIONS. 4. UNIONS AND FLANGES: A. COPPER PIPE: BRONZE UNIONS FOR 2 INCHES AND SMALLER. FOR 2-1/2 INCHES AND LARGEfR USE BRONZE FLANGED CONNECTIONS 150 POUND CLASS. B. DIELECTRIC UMiONS OR FLANGES: UNIONS SHALL MEET DIMENSIONAL REQUIREMENTS AND TENSILE STRENGTH OF PIPE UNIONS IN ACCORDANCE WITH FED. SPEC. WW-U- 531E. UNIONS OR FLANGES SHALL BE SUITABLE FOR REQUIRED OPERATING PRESSURES AND TEMPERATURE CONDITIONS. UNIONS SHALL HAVE METAL CONNECTIONS ON BOTH ENDS. ENDS SHALL BE THREADED OR SOLDERED TO MATCH ADJACENT PIPING. METAL PARTS OF UNION OR FLANGED SHALL BE SEPAREATED TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. EPCO DIELECTRIC PIPE FITTINGS OR EQUIVALENT. 5. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE:. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CEILINGS OF FINISHED AREAS. 6. PIPE INSULATION: A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELYf. B. ALL HOT WATER ANDI TEMPERED WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECIIVELV. 7. INSTANT -FLOW WATER HEATERS SHALL BE OF THE CAPACITY AND ELECTRICAL CHARACTERISTICS INDICATED ON PLANS AS MANUFACTURED BY CHRONOMITE LABORATORIIES,INC. 8. TRAP PRIMER SHALL BE SELF PRIMING TYPE ON COLD WATER SUPPLY LINE AS MANUFACTURED IBY PRECISION PLUMBING PRODUCTS, INC. "PRIME -RITE" #PR-500. WHEN TWIG OR MORE TRAPS REQUIRE PRIMING, PROVIDE WITH DISTRIBUTION UNIT /#DU-2, 3 OR 4 AND SUPPLY TUBE #SS-8 ASSEMBLY. PROVIDE ACCESS PANEL AND INSTALL AS PER MANUFACTURER'S RECOMMENDATION. 9. FLOOR DRAINS: AS IuAANUFACTURED BY JOSAM. A. FD-1: JOSAM 350000-A SERIES WITH 6"x6" SQUARE NIKALOY TOP AND 1/2" TRAP PRIMER CONNECTION. `�2 1. PRE -RATED GYPSUM WALLBOARDlYSTUD WALL ASSEMBLY 3 2. PLASTIC PIPE • NOM. 4.0 (OR SMALLER) SCH. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. SEE TABLE BELOW FOR REQUIRED ANNULAR SPACE. 3. TREMSTOP WS - INTUMESCENT WRAP STRIP, CONTINUOUSLY WRAPPED AROUND OUTER CIRCUMFERENCE OF THE PIPE. SEIE TABLE BELOW FOR MIN. WRAPS REQUIRED. 1. PRE -RATED GYPSUM WALLBOARD/STUO WALL ASSEMBLY 2, METALLIC PIPE: PIPE DAM. MG. SPACE 0 OF WRAPS A) STEEL PIPE -12' 0 (OR SMALLER) SCH.10 (OR HEAVIER) STEEL PIPE. 2 3/16 3 B) IRON PIPE -12"0 (OR SMALLER) CAST OR DUCTILE IRON PIPE. 3 1/8 4 C) COPPER TUBING - 4" 0 (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. 4 V8 8 D) COPPER PIPE - 40 (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. E) CONDUIT - 4"0 (OR SMALLER) EMT OR 6' 0 (OR SMALLER) STEEL CONDUIT. 4, TREMSTOP MCR • PREFABRICATED STEEL COLLAR WRAPPED OVER THE WRAP STRIPS (ITEM 3) AND THE ANNULAR SPACE SHALL BE MIN. W TO MAX 1' WITHIN THE FIRESTOP SYSTEM. MECHANICALLY FASTENED TO BOTH SIDES OF WALL ASSEMBLY. 3. TREMSTOPIA - MiN V2' THICKNESS OF SEALANT APPLIED WITHIN OPENING. MIN 3/r CANT BEAD OF TREMSTOP to OR TREMSTOP ACRYLIC (OPTIONAL) - MiN A BEAD OF SEALANT APPLIED AT THE SEALANT TO BE APPLIED AT AREAS OF POINT CONTACT. 5. WALLBOARDIUEVICE AND DEVICE/(PIPE INTERFACES. NOTE: TREMSTOP D CAN BE USED IN PLACE OF TREMSTOP WS AND TREMSTOP MCR. •TREMCO' MODEL: TREMSTOP IA FOR 1 OR 2 HOUR FIRE RATED PENETRATION FOR SINGLE METALLIC PIPE THRU GYPSUM WALL 'TREMCO' MODEL: TREIMSTOP D FOR 2 HOUR FIRE RATED PENETRATION F:OR SINGLE PLASTIC PIPE THRU GYPSUM WALL FIRE STOPPING DETAIL N.T.S. AN, 1f TION EXIST. 3" CW LINE TO REMAIN 1-1/4" P-TRAP FXI T TG `.STOREFRONT 'N/ DCO-RS TO � PLUMBINra FLOOR PLAN CONNECT NEW 1" r CW LINE TO EXIST. VERIFY EXACT LOCATION EXIST � ON SITE. 2" VENT UP 2" `\ PP=2ri-EXIST. 4" SAN. LINE. VERIFY 1" EXACT LOCATION I EXIST. 3" CW LINE hh I TO REMAIN CO \ ON SITE PP=1 ' 21, 3" WATER HAMMER I P=2 P-1 ARRESTOR (TYP.) 1/2„ DOMESTIC WATER PIPING ISOMETRIC SANITARY PIPING ISOMETRIC N.T.S. N.T.S. PLUMBING FIXTURE CONNECTION SCHEDULE COLD HOT SYMBOL DESCRIPTION DRAIN WATER WATER MANUFACTURER/MODEL TRIM P-1 WATER CLOSET 3' 1/2' -- AMERICAN STANDARD "CADET II' CLOSED COUPLE TANK WITH SPEED CONNECT TANK/BOWL COUPLING (HANDICAP) 12216.170, TWO-PIECE VITREOUS SYSTEM AND POLISHED CHROME TRIP LEVER. CHINA ELONGATED BOWL AND TANK SEAT: OLSONITE # 95 OPEN FRONT SEAT WITHOUT COVER. WITH BOLT HOLE COVERS. SUPPLY: BRASS -CRAFT POLISHED CHROME CAST BRASS ANGLE SUPPLY WITH WHEEL HANDLE STOP AND SHALLOW ESCUTCHEON, P-2 LAVATORY 1 1/4' 1/2' -- AMERICAN STANDARD "WHEELCHAIR FAUCET: DELTA # 3530-LHP CHROME BASE, 12' (HANDICAP) LAVATORY' 19140,013, WHITE WIDESPREAD FAUCET, 5"SPOUT WITH H24-A24 WITH 12" CENTER FAUCET HOLES, CHROME LEVER HANDLES, VANDAL RESISTANT SPRAY FRONT OVERFLOW AND CONCEALED # RP5202 OUTLET 0.5 GPM AND METAL POP-UP DRAIN ARMS SUPPORT. WITH PLATED FLANGED AND STOPPER. P-TRAP: McGUIRE 18872 POLISHED CHROME CARRIER: JOSAM # 17100 FLOOR -MOUNT CAST BRASS WITH WAIL BEND, CLEMOUT PLUG, CONCEALED ARMS SUPPORT, SLIP NUTS AND SHALLOW ESCUTCHEON. SUPPLY: BRASS -CRAFT ANGLE SUPPLY STOP WITH LOOSE KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID CHROME COPPER CONNECTION. INSULATION: McGUIRE "PROWRAP" #PW 2000 WC SEAMLESS INSULATORS FOR OFFSET DRAIN, TRAP, TAILPIECE, WASTE ARM AND HOT do COLD VALVES. P-3 WATER COOLER 1 1/2' 1/210 -- OASIS REF: LZS8 STAINLESS STEEL BOTTOM TOPS BARRIER -FREE ACCESS WATERWAY ARE LEAD-FREE IN MATERIALS 0 CONSTRUCTION RATED CAPACITY 8 GPH, 3.7 AMPS FLEXI-GUARD SAFETY BUBBLER. FULL LOAD , 1/4H.P. COMP. ., W?l •• � • r1� 1 II�,.. e )fk �tex• JMM Consulting Engineers LLC Certificate OF Authorization #9692 Jose M. Martinez, P.E. J66018 12661 South Dixie HWY. Suite 209 TEL. (306) 255-1621 Miami, Florida 33156 FAX (306) 255-1732 TO THE BEST OF MY KNOWLEDGE. THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS I'HE SOLE PROPERTY OF 'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF JMM CONSULTING ENGINNERS, LLC. BASIL'S TAILOR 4 ' SHOP I' CONSULTANTS sd *{ WRITTEN DIMENSIONS ON THIS DRACNG SHALL HAVE PRECEDENCE OVER SCALED DIMENSIQNS, CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON 0 THE JOB AND THIS OFFICE MIDST BE NOTIFIED. OF ANY VARIATION FROM THE DIMENSIONS. ` Revisions No. Desa�d'on De§a Project Name: BASIL'S TAILOR SHOP INTERIOR REMODELING 6001 SW. 70 ST. UNIT C-103 MIAMI, FLORIDA ►ate= ' OCT/ 2006 ►yawn: J.M.M. ,heckecr A bmit4lp .> As hawing Trle: r- y i1yY DfiPLUMBING.- OOR f'L.AN J R NQ P 1.� Iheet , h �rf I