06-1948-007
A/C EQUIPMENT SCHEDULE UNIT NUMBER AHU-1 AREA SERVED SEE FL. PLAN z TOTAL SUPPLY AIR CFM 1200 a OUTSIDE AIR CFM 245 �- EXTERNAL STATIC PRESS. H 20 0.5 FAN MOTOR HP/FLA 1 2 ELEC. CHAR. V 0 ti 208 10 60 COOL. COIL CAP. BTU HR 36,200 TOTAL SENS. HEAT BTU/HR ENT. AIR TEMP. 'F DB 'F WB 26,400 80 67 MODEL NUMBER -- UNIT MANUFACTURER RHEEM =d MODEL NUMBER RBHK-21 WEIGHT LBS. 180 REMARKS: REF. PIPING RS RL AS PER MANAF. z UNIT NUMBER CU-1 LOCATION SEE FL. PLAN z AMBIENT TEMP. °F 95 REFRIGERANT R 22 z COMP./COND. FAN FLA 16.0 RW 1.4 FTA cg ELEC. CHAR. V 0 ti 240 10 60 MANUFACTURER RHEEM MODEL NUMBER RAMC-036JA WEIGHT LBS. 245 a REMARKS SEER NOTES 13.6 c� UNIT MTD. ELEC. HEAT CAP. 10.0 KW STEPS OF ELEC. HEAT NO. 1 ELEC. CHAR. V 0 ti 208 1 60 NOTES: 1. PROVIDE ALL AHU'S WITH 7 DAYS PROGRAMMABLE THERMOSTAT. NOTES: AIR COOLED CONDENSING UNIT o ANGLE VALVE a FLEXIBLE CONNECTION +a AIR HANDLING UNIT s SUCTION LINE ++ DX COIL • la+ CHARGING VALVE +a THERMAL EXPANSION VALVE W/ 5 SLEEVES EXTERNAL. EQUALIZER 6 LIQUID LINE +� DOUBLE PORT SIGHT (;LASS 7 DRIER GLOBE VALVE TYPICAL REFRIGERANT PIPING DIAGRAM N.T.S. PIPING DIAGRAM TYPICAL PER REFRIGERANT CIRCUIT FOR UNITS WITH MULTIPLE CIRCUITS. S.A. DUCT PAN SCHEDULE UNIT NUMBER EF-1 AREAS SERVED BATH ROOM LOCATION CEILING DUTY SUPPLY/EXH. EXH. FAN TYPE CEILING FAN DRIVE BELT/DIRECT DIRECT FAN SPEED RPM AIR QUANTITY CFM 70 TOTAL STATIC PRESS. H 20 .125 OPENING REQUIRED IN. - FAN MOTOR ELECTRICAL CHAR. V/N/ti 115/1/60 MANUFACTURER BROAN MODEL NUMBER 671 WEIGHT LBS. REMARKS SONES 3,0 NOTES: 1. FAN EF-1 SHALL BE INTERLOCKED TO LIGHT FIXTURES. 2. ALL FANS SHALL BE PROVIDED WITH BACKDRAFT DAMPER INSULATED ROUND COLLAR W/ MANUAL VOLUME DAMPER DRAWBAAN7D -� BENENAETH ISULATION DIFFUSER OR GRILLE INSULATED FLEXIBLE DUCT INSULATED ROUND COLLAR CEILING INSULATED SQUARE BOX FOR I�UU SQUARE NECK gg INFNU IRED WIT REDUCER TYPICAL CONNECTION TO AIR DIFFUSER N.T.S. FLEXIBLE - CONNECTION SOUND INSULATED HOUSING ADJUSTABLE MOUNTING FLANGE AIR FLOW EXHAUST DUCT CENTRIFUGAL FAN INSIDE HOUSING AIR DISTRIBUTION SCHEDULE SYMBOL NECK SIZE MFGR. MODEL NUMBER REMARKS SEE FL PLAN TITUS TDC S/A DIF. ©SEE FL PLAN BUSKIN EME 66250 LOUVER ® SEE FIX PLAN TITUS SERIES1FFUSER 25RS R/A OR. NOTES: 1. REFER TO PLAN FOR QUANTITY, LOCATION AIR THROW PATTERN AND SIZES. 2. ALL AIR DISTRIBUTION DEVICES SHALL BE OF EXTRUDED ALUMINUM CONSTRUCTION, FURNISH WITH OPPOSED BLADE DAMPERS AND CONCEALED MOUNTING FRAME FOR ACOUSTICAL OR PLASTER CEILING INSTALLATION. HVAC SYMBOL LEGENDi ® THERMOSTAT 0 ROOF MTD. EXH. FAN ® DUCT SMOKE DETECTOR L^J DUCT TURN DOWN TRANSITION DUCT TURN UP TURNING VANE FLEXIBLE DUCT r 1 45• BRANCH DUCT TAIKE-OFF Lie J EXISTING SUPPLY HORIZONTAL FIRE DAMPER r T, LL A EXISTING RETURN • D. MANUAL VOLUME DAMPER ® NEW SUPPLY RETURN REGISTER ® NEW RETURN SUPPLY DIFFUSER V-- FIRE DAMPER RETURN AIR GRILLE -- VALVE -► AIR FLOW DIRECTION POINT OF CONNECTION BETWEEN NEW & EXIST. WORK NOTES: AIR HANDLING UNIT SECURED TO STRUCTURE W/ HANGER RODS. PROVIDE VIBRATION ISOLATORS MASON MODEL PC30N OR EQUAL OUTSIDE AIR DUCT W/ MANUAL VOLUME DAMPER SEE FLOOR PLAN FOR SIZE. RET. AIR D:SEEn. W/ O.B.D. FLOOR PLAN FOR SIZE REMOVABLE ALUM. CEILING GRILLE AIR FLOW TYPICAL CEILING TYPE EXHAUST FAN DETAIL N.T.S. 1/4"0 STAINLESS STEE CABLE W/ PLASTIC CC BOLTED TO STEEL SUF FRAME W/ 3/8' BOLT' TO WITHSTAND 150 MF HURRICANE FORCE W$ (TYPICAL) ROOW RETURN AIR PLENUM WITH FILTER RACK,ACCESS DOOR(S),FILTER(S). LOCATE FOR EASE OF ACCESSIBILITY. CONC FLOOR/ROOF DECK .. :f# . 4 SUPPLY AIR DUCT. SEE FLOOR PLAN RIEF. PIPING HANGER RODS FOR SIZES O L-DUCT MOUNTED SMOKE DETECTOR WHERE SPECIFIED CONDENSATE DRAIN LINE AND '.V'-FIN. CEILING TRAP.REFER TO PLUMBING DWGS. AUXILIARY DRAIN PAN W/ FLOAT SWITCH SHALL BE 6" BIGGER THAN THE AHU ON ALL SIDES, 2 INCHES DEEP, GAGE 16 GALVANIZED STEEL AIR HANDLING UNIT MOUNTING DETAIL N.T.S. CONDENSING UNIT BOLTED TO STEEL SUPPORT FRAME W/ 3/8' BOLTS TO WITHSTAND 150 MPH HURRICANE FORCE WINDS. (TYPICAL AT UNIT MOUNTING POINTS) VIBRATION ISOLATORS (TYP.) MIAMI-DADE COUNTY APPROVEC SUPPORT FOR FLASHING SEE DETAIL WELD INSULATION STL. PLATE THRU-BOLTS WITH NUTS CONC. SLAB MAINTAIN MFR'S RECOMMENDED CLEARANCES FOR AIRFLOW AND MAINTENANCE ACCESS CONDENSING UNIT OOF MOUNTING DETAIL N.T.S. NOTE: CONDENSING UNIT SUPPORT FRAME SHALL BE AS MANUFACTURED BY PRECISION ALUMINUM PRODUCTS, INC., MIAMI-DADE COUNTY APPROVED NOA No. 02-0514.02 ALUMINUM ALLOY CONSTRUCTION (2) 1/4.0 STAINLESS STEEL )LE W/PLASTIC COVER CONDENSING UNIT 1/4.0 STAINLESS STEEL CABLE W/ PLASTIC COVER -BOLTED TO STEEL SUPPORT FRAME W/ 3/8' BOLTS TO WITHSTAND 150 MPH HURRICANE FORCE WINDS. (TYPICAL) ROOF MOUNTED EQUIPMENT HEIGHT REQUIREMENTS WIDTH OF EQUIPMENT HEIGHT OF LEGS (INCHES) (INCHES) UP TO 24 14 25 TO 36 18 37 TO 48 24 49 TO 60 30 61 AND WIDER 48 HVAC GENERAL NOTESm 1. CONTRACTOR SHALL. COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO ORDERING AND/OR INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. 2. THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT PERMITS, FEES, INSPECTIONS, TESTS, INSURANCE, ETC., REQUIRED FOR THE COMPLETION OF THE AIR CONDITIONING, HEATING AND VENTILATION SYSTEMS SHOWN ON DRAWINGS OR LISTED BELOW. 3. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW EVERY BEND, OFF -SET, ELBOWS OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED, OR FOR COORDINATION WITH OTHER TRADES. 4. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS, AND SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF MECHANICAL EQUIPMENT AND APPURTENANCES. 5. VERIFY ALL SPACE CONDITIONS & DIMENSIONS AT JOB SITE PRIOR TO FABRICATION OF DUCTWORK AND INSTALLATION OF EQUIPMENT AND ACCESSORIES. 6 A BALANCING CONTRACTOR SHALL ADJUST AND BALANCE AIR DISTRIBU- TION DEVICES IN ACCORDANCE WITH QUANTITIES SHOWN ON PLANS FOR REGULAR H11AC OPERATION AND FOR REQUIRED BUILDING PRESSURIZATION REQUIREMENTS. 7. CONTRACTOR SHALL COORDINATE WITH TENANT SO THAT ANY EQUIPMENT OR DEVICE TO REMAIN THAT MAY HAVE TO BE DISCONNECTED BECAUSE OF THE REMOVAL OF ANY OTHER DEVICE IS RECONNECTED AND TIED BACK TO THE EXISTING BUILDING SYSTEM(S) AND TESTED FOR CORRECT OPERATION. 8. ANY WORK NOT SHOWN ON DRAWINGS OR SPECIFICALLY MENTIONED IN THE HVAC NOTES BUT CONSIDERED NECESSARY FOR THE COMPLETION OF THE WORK IN PROPER MANNER SHALL BE PROVIDED BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGE. 9. COORDINATE SPACE ACCESSIBILITY AND WORKING HOURS REQUIREMENTS WITH OWNER'S REPRESENTATIVE PRIOR TO BIDDING THIS PROJECT. OTHER AREAS IN THIS OR ADJACENT SPACES MAY HAVE SPECIAL REQUIREMENTS FOR ACCESSIBILITY TO EXISTING BUILDING SYSTEMS PRESENTLY IN THEIR SPACES BUT WHICH MAY NEED TO BE ACCESSED FOR THIS PROJECT. 10. CONTRACTOR SHALL DO HIS OWN CUTTING AND REMOVAL OF ALL HIS RELATED WORK IN ALL LOCATIONS WHERE REQUIRED EXCEPT WHERE OTHERWISE SHOWN ON THE DRAWINGS AND/OR AS SPECIFIED AND/OR AS COORDINATED WITH TENANTS. 11. ALL BUILDING CONSTRUCTION AFFECTED BY THE REMOVAL, RELOCATION, INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL BE REPAIRED AND REFINISHED AS REQUIRED TO MATCH EXISTING CONDITIONS OR AS DIRECTED BY THE ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS. 12. DUCTWORK: A. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH GAUGES, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE AS.H.RAE. GUIDE AND S.MAC.NA STANDARDS. DUCT SIZES SHOWN ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION. B. AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE 1-1/2" (R-6 MIN.) FIBERGLASS U.L. 181 USTED, CLASS I AIR DUCT. DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH S.M.AC.NA STANDARDS. C. FLEXIBLE DUCT SHALL BE STEEL HELIX WIRE ON 7/8' CENTERS, ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR WELDING TO FORM AN AIR TIGHT INNER CORE, THE CORE IS TO BE INSULATED WITH FIBERGLASS INSUTATION (R-6), AND SHEATHED IN A REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE DUCT IS CONNECTED TO RECTANGULAR DUCTWORK. DAMPER ACTUATOR SHALL BE EXTENDED OUTSIDE INSULATION. 13. AIR DISTRIBUTION: A SUPPLY AND RETURN AIR DIFFUSERS SHALL BE OF EXTRUDED EXTRUDED ALUMINUM CONSTRUCTION OR AS SPECIFIED. 14. PROVIDE ACCESS PANELS IN WALLS OR CEILING FOR DAMPERS, CONTROL DEVICES, ETC. ACCESS PANELS SHALL BE MILCOR FLUSH TYPE. COORDINATE LOCATION WITH ARCHITECT. 15. SUBMIT SHOP DRAWINGS OF ALL MATERIALS, DUCTWORK AND EQUIPMENT FOR REVIEW PRIOR INSTALLATION AND/OR FABRICATION. 16. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR THE PERIOD OF ONE YEAR. PERIOD OF GUARANTEE SHALL COMMENCE UPON RECEIPT OF CERTIFICATE OF OCCUPANCY. 17. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 FLORIDA BUILDING CODE 18. SUBMIT A COMPLETE 'AS -BUILT" RECORD SET IN REPRODUCIBLE PAPER SEPIA FORM TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FINAL PAYMENT REQUISITION. 19. TESTING: A. BALANCE AIR SYSTEM TO DELIVER SPECIFIED AIR QUANTITIES AT EACH OUTLET WITHIN 10% USING AAB.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST RESULTS FOR REVIEW PRIOR TO FINAL INSPECTION AND ACCEPTANCE. 20. ALL WAG EQUIPMENT, AIR DISTRIBUTION, CONTROLS, APPURTENANCES, ETC. SHALL BE AS SHOWN ON THE DRAWINGS WITH RESPECT TO CAPACITY,QUALITY PERFORMANCE,ACCESSORIES,ETC.MANUFACTURERS USED FOR THE BASIS OF DESIGN ARE LISTED ON THE DRAWINGS SCHEDULES OR SPECIFIED HEREIN. SUBSTITUTIONS MUST MEET OR EXCEED ALL SPECIFIED REQUIREMENTS. NAMING ACCEPTABLE MANUFACTURERS DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH ALL DESIGN REQUIREMENTS SHOWN ON THE DRAWINGS OR LISTED HEREIN, 21. ALL INSULATION PRODUCTS AND ACCESSORIES SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR LESS IN ACCORDANCE WITH ASTM E84. 22. SUBMIT SHOP DRAWING OF ALL MATERIALS AND EQUIPMENT FOR APPROVAL PRIOR TO FABRICATION. 23. TEMPERATURE CONTROL SHALL BE A PROGRAMMABLE ROOM THERMOSTAT FOR HEATING/COOLING WITH STAGES AS REQUIRED. 24. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD. 25. GUARANTEES: A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL HAVE A MIN. 5 YEARS PRODUCT GUARANTEE FROM DATE OF START-UP. B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN A 1,YEAR FROM DATE OF ACCEPTANCE. 26. TESTING: A ALL REFRIGERANT HIGH SIDE PIPING TO 300 PSIG. LOW SIDE TO 150 PSIG. AFTER TESTING, EVACUATE SYSTEM TO 28% MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 25 HOURS WITH PUMP OFF. BREAK VACUUM WITH REFRIGERANT. yy 27. ALL CONDENSATE PIPING SHALL BE COPPER DWV. INSULATE COND. PIPS ABOVE GROUND WITH 3/4 INCH ARMAFLEX INSULATION. A, ... JMM Consulting Engineers LLC Certificate OF Authorization #9692 Jose M. Martinez, P.E. #56018 12651 South Dixie HWY. Suite 209 TEL (306) 255-1621 Miami, Florida 33156 FAX (306) 256-1732 TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF JMM CONSULTING ENGINEERS LLC AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION l OF JMM CONSULTING ENGINNERS, LLC. BASIL'S TAILOR SHOP SEAL WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS, CONTRACTOR SHALL VERIFYAND BE RESPONSIBLE FCRALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS. Revisions Dale Project Name: BASIL'S TAILOR SHOP INTERIOR REMODELING 6001 SW. 70 ST. UNIT C-103 MIAMI, FLORIDA I� N,: Sca!e: Date: OCT/ 2006 Drawn: J.M.M. Checked: Submittak Drawing Tide: MECHANICAL DETALS Sheet No. M-2