06-1948-002WINDOW SCHEDULE ROOM SCHEDULE DOOR SCHEDULE TYPEWIDTH NAME GLAZING SIZE REMARKS ROOM FLOOR BASE WALLS CEILING REMARKS No. SIZE MATERIAL TYPE FRAME THRESHOLD STRIPP c HARDWARE s�olR REMARKS MATEIRIAL HGT. HEIGHT A FIXED WINDOW CLEAR 3'-6" 3'-0" SAFETY GLASS CAT.11 RETAIL AREA SEWING WORKSHOP LAMINATE WOOD LAMINATE WOOD WOOD WOOD GYP. BD. GYP. BD. GYP. BD. GYP. BD. 8'-6" 8'-6" 1 2 2'-6" x 6'-8" x 1 3/8" 3'-0" x 6'-8" x 1 3/4" HOLLOW CORE WOOD WOOD HOLLOW CORE WOOD PRE -HUNG WOOD PRE -HUNG NONE SEE MANUFTR. NO NO BY DOOR MANUFACTURER BY DOOR MANUFACTURER YES YES OFFICE LAMINATE WOOD WOOD GYP. BD. GYP. BD. 8'-0" 3 2'-4" x 6'-8' x 1 3/4" WOOD WOOD PRE -HUNG NONE NO BY DOOR MANUFACTURER YES LOUVERED H.C. RESTROOM CER. TILE 4" CER. TILE MOIST. RST. G.B. MOIST. RST. G.B. 7'-8" FITTING ROOM LAMINATE WOOD WOOD GYP. BD. GYP. BD. 1 8'-0" 8' I MI OR I G o I H. I_----- - I ' 2• O" I --[----------DIAM.=5'-O' MI 2 • 1 3 4 TOILET - PAPER HOLDER 4" WIDE (FULL HT). H.C. TOILET FLOOR PLAN PARTITION REINFORCED BACK OF GRAB BARS & LAVATORY CEILING LINE W/ 5/8" EXT. GRADE PLYWOOD (TYP.) 1/2" GYP. BD. (M.R.)—) PAINTED HANDIC W.C. U12*[0 i --- - -- -- - -- -5' HT C R. TI ETFU CEILING ELEVATION Al NOTE: M.R. = MOISTURE RESISTANCE CEILING LINE 1 /2" GYP PAINTED 5' HT. CER. T CEILING LINE 1/2" GYP. BD. (M.R.) PAINTED MIRROR (SAF GLASS, CAT 11) `P I HANDICAP LAVATORY - FAUCET LEVER TYPE 5' HT. CER. TILE TOILET PAPER— —> >/z x 4z HOLDER GRAB BAR ELEVATION 4 ELEVATIONA3 H.C. BATHROOM FLOOR PLAN & INTERIOR EL VATION SCALE: N.T.S. 0 WINDOW ELEVATIONS N.T.S. FLUSH FLUSH LOUVERED 0 0 0 DOOR ELEVATIONS N.T.S. TOILET PAPER ELEVATION HOLDER WARM AIR DRYER SOAP DISPENSER REINFORCED BACK OF LAVATORY W/ 5/8" EXT. GRADE PLYWOOD (TYP.) 1 1 /2" 0 X 3"-0" GRAB BAR ADA ACCESIBILTY GUIDELINES ALL PUBLIC ACCOMODATIONS AND RESTROOMS SHALL COMPLY WRH THE AMERICANS WM DISABILITIES ACT. PUBLIC LAW 101-336. AND CODE OF FEDERAL REGULATIONS TITLE 20, CHAPTERI. PART 36 WITH APPENDIX A "STANDARDS FOR ACCESSIBLE DESIGN" ILLUSTRAITED BY THE A.DA ACCESSIBILITY GUIDELINES WITHIN THE FEDERAL REGISTER VOL56. NO.14.4 OF JULY 26, 1991. HANDICAP SIGNAGE NOTE: - WHERE PERMANENT SIGNAGE IS PROVIDED IT SHALL BE LOCATED ON THE WALL ON THE LATCHED SIDE OF THE DOOR 60' AFF TO THE CENTER AND SHALL COMPLY W/REQUIRZEMENTS OF 11.4.30 FBC. SIGNAGE TO PERMANENT ROOMS SHALL COMPLY W/ 11.4.30.1,4,5, AND 6 FBC. SIGNAGE TO PROVIDE DIRECTION IN SHALL COMPLY W/ 11.4.30.1,2„3, AND 5 FBC. NOTE 1204.2 FBC. 1204.2 SURROUNDING MATERIALS. THE WALLS AND FLOORS OF ALL PUBLIC REST ROOMS SHALL BE LINED WITH NONABSORBENT MATERIAL TO A HEIGHT OF 4 FT. ABOVE THE FLOOR. LOCATIONS OF FIXTURES ARE SHOWN TO ILLUSTRATE BASIC GUIDELINESOF THE A.DAAG. FIXTURE ARRANGEMENT WITHIN RESTROOMS ARE SHOWN ON EQUIPMENT AND PLUMBING PLANS. x 4" WOOD BACKING TOP OF WALL CABINET iERIOR PARTITION 5/8" METAL STUDS 16 O.C. kLL CABINET x 4" WOOD BACKING BOTTOM OF WALL 1BINET AND AT WALL 1NG PLUMBING FIXT. A MINIMUM 2"X4" HORIZONTAL WOOD MEMBER SECURELY FASTENED TO NOT LESS THAN 2 STUDS SHALL BE INSTALLED FOR THE ATTACHMENT OF EACH WALL HUNG PLUMBING FIXTURE AND WALL CABINET N.T.S. UNDERSIDE OF STRUCTURE UNDERSIDE OF STRUCTURE EXTEND STUDS & GYB. BD.TOEXTEND STUDS & GYB. BD.TO STRUCTURE ABOVE STRUCTURE ABOVE CEILING AS SCHED. CEILING AS SCHED. HEAD HEAD 1/2" GYPSUM BOARD, 1/2" GYPSUM BOARD, TYPE 'Y TYPE "X" STUDS, TAPE AND STUDS, TAPE AND SPACKLE ALL JOINTS SPACKLE ALL JOINTS 3 5/8" METAL STUDS 3 5/8" METAL STUDS AT 16" O.C. AT 16" O.C. WALL FINISH Z z WALL FINISH AS SCHEDULED Q Q AS SCHEDULED z z PLAN PLAN LLJ Ld z z Li. LL O O LLI LLJ 0 C) Cn V) WALL BASE WALL BASE AS SCHEDULED AS SCHEDULED CONT. SEALANT AT FLOOR CONT. SEALANT AT FLOOR AND SIDES OF WALL, AND SIDES OF WALL, BOTH SIDES OF WALL BOTH SIDES OF WALL FINISH FLOOR FINISH FLOOR AS SCHEDULED AS SCHEDULED TOP OF FLOOR SLAB TOP OF FLOOR SLAB BASE FIRE RATING REQUIREMENTS: 1 HR. FIRE RATING REQUIRED WALL SECTION SCALE: N.T.S. z Qom. LLJ � I 3�: I L.LJ z I LL_ I O LIJ C I UNDERSIDE OF STRUCTURE e EXTEND STUDS TO STRUCTURE ABOVE METAL STUD CAP AS FIRESTOPPING CEILING AS SCHED. 1/2" GYPSUM BOARD, BOTH SIDES OF MTL. STUDS, TAPE AND SPACKLE ALL JOINTS 3 5/8" METAL STUDS AT 16" O.C. WALL FINISH AS SCHEDULED PLAN WALL BASE AS SCHEDULED CONT. SEALANT AT FLOOR AND SIDES OF WALL, BOTH SIDES OF WALL FINISH FLOOR AS SCHEDULED TOP OF FLOOR SLAB o L�. d a BASE A A d BASE FIRE RATING REQUIREMENTS: 1 HR. FIRE RATING REQUIRED FIRE RATING REQUIREMENTS: NO FIRE RATING REQUIRED WALL SECTION_____�* WALL SECTION __* SCALE: N.T.S. SCALE: N.T.S. 20 GA. GALV. MTL. 3 5/8" MTL. STUDS 1 /2" GYPSUM WALLBOARD WOOD CASING Is PROVED By MAM4ADE COUNlY FIRE DEPA iMIAT 20 GA. GALV. MTL. 3 5/8" METAL STUD_ BLS. pEITtU1fTRpto1S11E-_ 2 X 4 WD. STUD WATJ_;F2 iV1Ai4-- DOOR STOP INTERIOR WOOD DOOR JAMB 1/2" GYPSUM WALLBOARD I NT. WOOD DOOR JAMB DETAIL SCALE: N.T.S. BASIL'S TAILOR SHOP SEAL � III ti ANTONIO ACOSTA P.E. III # 40845 103OS NW. 41 ST. M IAM I, FL 33178 Ph: (305) 856 4606 i CONSULTANTS WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS. Revisions Na Dwaoon fete Project Name: BASIL'S TAILOR SHOP INTERIOR REMODELING 6001 SW. 70 ST. UNIT C-103 MIAMI, FLORIDA File: Scale: Date: OCT/ 2006 Drawn: A.P. Checked: Submittal: Drawing Title: SECTIONS, DETAILS & ELEVATIONS Sheet No. A-1