Loading...
06-1796-010SPRINKLER HEAD SCHEDULE AREA SERVED MFR. & MODEL NO. ORIFICE SIZE CONFIGURATION TEMP. RATIING REMARKS AREAS WITH DROPPED OG DI URN HATJWD VILKNO MICROFAtiT mo M ..1//2' R"S 8 STAT�ARD cM04AOE ORDINARY WHITE POLYESTER DMTIN N III FfRE FizOTEGTfON FLOOR FLAN 1 /4 It = 11- 0 N t i D I 4 H a I 0 EXISTING BRANCHLINE CENTER,I r EXISTING 1' NIPPLE' NEW 1" ELBOW ALL THREADEDi 7--91=HANGER ROD II T W SPRINKLER HEAD TO BE REMOVED. NEW CONCEALED SPRINKLER HEAD. CENTRAL III BV-4 STANDARD SPRAY. *ARMOVER GREATER THAN 24" IN LENGTH SHALL BE SUPPORTED BY A HANGER. II RELOCATION DETAIL N.T.S. BRANCHLINE MECH-TYPE TEE 1" ARMOVER NEW CONCEALED SPRINKLER HEAD. CENTRAL # BV-4 STANDARD SPRAY. *ARMOVER GREATER THAN 24" IN LENGTH SHALL BE SUPPORTED BY A HANGER. ARMOVER DETAIL N.T.S. FIRE PROTECTION NOTES 1. ALL PIPING,HANGERS,SUPPORT METHODS AND SPRINKLER HEADS TO BE INSTALLED IN STRICT ACCORDANCE WITH N.F.PA 13. AND ALL LOCAL CODES AND ORDINANCES. 2. SPARE SPRINKLER HEADS AND WRENCHES SHALL BE PROVIDED IN ACCORDANCE WITH N.F.PA 13. 3. FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND COORDINATION TO AVOID INTERFERENCE WITH THE WORK OF OTHER TRADES. 4. ALL ARMOVERS TO INDIVIDUAL SPRINKLER HEADS SHALL BE ONE INCH PIPE SIZE. 5. HANGER SPACING AND METHOD SHALL BE IN ACCORDANCE WITH N.F.P.A. 13. REQUIREMENTS. 6. ALL RATED WALLS TO BE PROPERLY SLEEVED AND SEALED WITH APPROVED FIRE AND SMOKE STOP MATERIAL 7. PROVIDE AUXILIARY DRAINS FOR ALL TRAPPED PIPING SECTIONS AS REQUIRED. 8. ALL WORK SHALL BE IN ACCORDANCE WITH N.F.P.A. 13 STANDARDS AND IN CONFORMANCE WITH ALL LOCAL CODES AND ORDINANCES AND COMPLY WITH BUILDING STANDARD REQUIREMENTS. 9. DESIGN CRITERIA: DESIGN CRITERIA SHALL BE BASED ON N.F.P.A. 13 LIGHT HAZARD,.10 ,GPM PER SQ. FT. DENSITY, MINIMUM 1500 SQ. FT. REMOTE AREA, 100 GPM HOSE ALLOWANCE. (TYPICAL FOR ALL OTHER AREAS) 10.000RDINATE ALL SYSTEM ZONE SHUT -DOWNS WITH OWNER'S REPRESENTATIVE MINIMUM OF 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 11 ALL PIPING ABOVE GROUND SHALL BE LIGHTWALL THREADABLE STEEL PIPE FOR 2" AND SMALLER, ROLL AND GROOVED SCHEDULE 10 STEEL PIPE FOR PIPING 2 1/2" AND LARGER. AWED XL AND AWED SCH. 10 OR APPROVED EQUAL FITTINGS ' FOR PIPING 2" AND SMALLER SHALL BE MALLEABLE IRON, 150 PSI BANDED,THREADED,BLACKANSI B 16.3. FITTINGS FOR PIPING 2 1/2" AND LARGER SHALL BE MECHANICAL COUPLING SYSTEM AS MANUFACTURED BY VICTAULIC CORROR GRINNELL CORP. "GRUVLOCK". ALL FITTINGS SHALL BE FROM SAME MANUFACTURER. 12.THE WORK THAT IS TO BE DONE UNDER THIS CONTRACT INCLUDES THE FURNISHING OF ALL LABOR,MATERUILS AND EQUIPMENT ,PERMITS FEES, INSPECTIONS, TESTS INSURANCE,ETC. REQUIRED FOR THE COMPLETION OF FIRE PROTECTION SYSfiEM SHOWN ON THE DRAWINGS AND LISTED HEREIN. 13.7THE DRAWINGS ARE GENERALLY DIAGRAMMATIC.THEY DO NOT SHOW EVERY BEND OFFSET OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN TI fE SPACE ALLOCATED, OR FOR COORDINATION WITH OTHER TRADES. VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOBSITE PRIOR TO FABRICATION OF PIPING AND INSTALLATION OF EQUIPMENT AND MATERIALS. 14ALL WORK SHALL BE IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE. N.F.P.A. 13, 24. 25 . 101, 231C AND IN ACCORDANCE WITH ALL LOCAL CODES AND ORDINANCES. 15. ALL WORK SHALL BE PERFORMED BY STATE LICENSED AND CERTIFIED PERSONNEL IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE 4A-46 & 4A-48. SUBMIT TO OWNERS REPRESENTATIVE AS BUILT DRAWINGS, OWNER'S MANUAL, MAINTENANCE MANUALS. I 16. COORDINATE FIRE SYSTEM SHUTDOWNS WITH OWNER'S REPRESENTATIVE MINIMUM OF 48 HOURS PRIOR TO COMMENCEMENT OF WORK. ALL THRE HANGER NUT CLEVIS HA PIPE 0 PIPE STEEL I BEAM OR BAR JOIST ALL THREADED HANGER ROD FASTENERS N.T.S. ALL FASTENERS SHALL BE LISTED FOR THEIR INTENDED SERVICE ALL THREADED _ HANGER ROD NUT — ADJUSTABLE SWIVEL LOOP HUNGER � r PIPE --�_ / PIPE HANGERS N.T.S. ALL HANGERS SHALL BE LISTED FOR THEIR INTENDED SERVICE FIRE PROTECTION LEGEND NEW PENDENT TYPE SPRINKLER HEAD LIE EXISTING UPIGHT SPRINKLER HEAD TOPE REMOVED POINT OF CONNECTION BETWEEN NEW AND EXIST. PIPE — — — EXISTING SPRINKLER • PIPING NEW SPRINKLER PIPING GENERAL NOTES: CONC. SLAB . e /ICI DROP IN ANCHOR - ALL THREADED HANGER ROD POWDER DRIVEN STUDS MAY BE USED IN UEU OF LISTED CONCRETE INSERTS WHERE APPROVED BY STRUCTURAL ENGINEER ALL HANGER RODS, HANGERS, FASTENERS, ETC. SHALL BE PROVIDED WITH FACTORY APPLIED CORROSION PROTECTION COATING 1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE, STATE AND LOCAL ORDINANCES. 2. 19UILDNG DRAINAGE SYSTEM TO BE SLOPED AT 1/8' PER M MIN. FALL FOR 3' PIPE AND LARGER 1/4' PER FT. SLOPE FOR 2' PIPE SIZE AND SMALLER DEVIATIONS SHALL BE APPROVED BY ARICHITECT/ENGMER - 3. PROVIDE CLEAN OUTS EVERY "I b FT. AND AT BASE OF EVERY WASTESTACIC ALL CLOSE-OUTS TO BE FLUSH MOUNTED. 4, MATERIALS SHALL BE ALL NEW AND AS FOLLOWS: A DRAINAGE WASTE AND VENT PIPMG INCLUDING: NO HUB CAST IRON CISPI STANDARD SO ABOVE GROUND AND CAST IRON HUB, PLAN END ASTM A-14 WITH NEO- PRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN ITS APPROVED 5Y LOCAL AUTHORITIES AND, NOT TO BE USED IN AIR RETURN PLENUM B. WATER PIPING: COPPER TYPE 'L' ASTM 8=88 ABOVE GROUND AND COPPER TYPE 'K' ASTM 15-88 UNDERGROUND. C. VALVES: 125 PSI NIBCO SCOTT, STOCK14AM CIA EQUAL. 5. PERFORM THE FOLLOWING TEST: A WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF VW PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN ONE HOUR- 13. DRAINAGE SYSTEM: BEFORE INSTALLATION OF ANY DRAINS, THE END OF THE SYSTEM SHALL BE CAPPED 4 ALL LINES FILLED WITH WATER TO HIGHEST PONT 4 ALLOWED TO STAND UNTIL NSPECTION IS MADE AND WATER LEVELS REMAIN CONSTANT C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTS. D. COMPLETE SYSTEM FIXTURE 4 EQUIPMENT SHALL BE GIVEN AN IN SERVICE TEST AFTER COMPLETION OF THE NSTALLATION. E. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) POUNDS OF CHLORINATED LIME TO EACH IWO gal. OF WATER (50 PPM OF AVAILABLE CHLORITE.) RETAN MIXTURE N PIPES FOR 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING N SERVICE. 6- PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WO1I4ANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE, AND THAT HE WILL, AT HIS EXPENSE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING GUARANTEE PERIOD. 1. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF EXISTING UTILITIES AND POINTS OF CONNECTION BEFORE COMMENCING ANY WORK. 8. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES TREW RED. -L SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQWPhIENT, MATERIALS AND LAYOUTS PRIOR INSTALLATION. IV. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE, DUCTWORK, ETC. AS SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS. 1L PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A/C CONDENSATE DRAIN AND TRAP. SEE A/C PLANS FOR LOCATION OF UNITS AND DRAINS. 12. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 13. COORDINATE WORK WITH OTHER TRADES. 14. FURNISH AND INSTALL FIXTURES AS SPECIFIED N SCHEDULE, THIS DRAWING. ID. EACH 5AT14ROOM GROUP SHALL BE PROVIDE WITH AIR CHAMBERS OR SHOCK ABSORBER 16. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE, JUST BEFORE CONNECTING TO FIXTURE li. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 1 THESE DRAVVINIGS HAVE BEEN REVIEWED VOR COMPLIANuE WITH N.F.P.A. 13 AND IFA.0 61.G15-32.004 (DESIGN OF WATER BASED FIRE PRO,TECTION SYSTEMS) ATHRU J. A COY �.�^�Jl' THESE APPROVED DRAMNGS MUST BE SUBMj1TT WITH THE SHOP D 7clCy-T! OOVAL. DATE AM Consulting Engineers LLC r �� - •�" `� �; " . • • • � :�s' Certificate 0 F Authorization #9692 dose M. Martinez, P.E. #56016 12651 South Dixie M. Suite 209 TEL (305) 255-1621 ' Miami, Florida 33156 FAX (305) 255-1732 �: Y , • ,, y�}j�(/'{, , TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE ' �• y%j °' •• ly«� APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BEw REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION ',,�� .+.��+,f�.•� t� OF JMM CONSULTING ENGINNERS, LLC. ui r ate' , IIQ J r CO cm m O m H � N w aW V Z03�� aC X. LV �—No U. Joy aJ40 >a W .*�f► Y rp�w _.adEwE1p1 �li._I\kwpl I►_: RATE �I►TE � IIdk t< e l l vp 1OF 1 r A