06-1796-008PLUMBING GENERAL NOTES A. UNLESS OTHERWISE SPECIFIED ON THIS DRAWING CONTRACTOR SHALL REFER TO ORIGINAL LANDLORD SPECIFICATIONS FOR ALL APPLICABLE REQUIREMENTS. NOTES, DETAILS, CONSTRUCTION'S STANDARDS, ETC., COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO ORDERING AID/OR INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF/HERSELF WITH THE NATURE AND D(TEND OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE SINCE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEM AND FACLITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, EXISTING FACILITIES AND ALL BULDINIG STRUCTURES TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS, VARIATIONS IN ROUTING AND/OR CONSTRUCTION SHOULD BE ANTICIPATED BY THIS CONTRACTOR AND ARE E XPRESSL.Y INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBUGATION AND RESPONSIBLITIFS ASSUMED UNDER THIS CONTRACT. 2. THE NATURE OF THE REMODEL TYPE CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEERS AS WELL AS THE PLUMBING CONTRACTOR. EVERY EFFORT WAS BEEN MADE BY THE ENGINEERS TO SHOW AND IDENTIFY THE LOCATIONS AND TYPES OF EXISTING PLUMBING SYSTEMS, THE MAJOR PORTION OF THE PLUMBING SYSTEMS ARE AS SHOWN ON THE DRAWINGS HOWEVER DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. PLUMBING CONTRACTOR SHALL PERFORM A FIELD VERIFICATION BEFORE BIDDING THIS PROJECT. 3. CONTRACTOR WILL BE RESPONSIBLE FOR COODINATING HIS DEMOLITION WORK WITH OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING SYSTEMS TO REMAIN. 4. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING PIPES BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. 5. ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WADS, CHASES OR PARTITIONS. 6. EXISTING PIPES SERVING AREAS NOT COVERED BY THIS CONTRACT BUT IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED EXCEPT AS A TEMPORARY INTERRUPTION COORDINATED WITH THE OWNER AND LANDLORD. 7. PWMBING CONTRACTOR SWILL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 8. PLUMBING CONTRACTOR SHALL. VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 9. COORDINATE ALL WORK WITH OTHER TRADES, 10. PLUMBING CONTRACTOR SWILL. GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE 11. PROVIDE SHOCK ABSORBERS SIZE, QUANTITY AND LOCATION AS PER P.D.I. STANDARDS. 12. PROVIDE SHUT-OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH FIXTURE SUPPLY. 13. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 14. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH -INS WITH THE MANUFACTURER BEFORE MAKING ANY INSTALLATION. 15. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE "LEAD FREE" WITH LEAD CONTENT NOT EXCEEDING 0.2 PERCENT FOR SOLDER AND FLUXES AND 8 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. CONTRACTOR SHALL VERIFY MMUFAC LITER'S COMMANCE 16. ALL POTABLE HOT AND COLD WATER SYSTEMS SWILL BE FLUSHED CLEAR, STERIUZER WITH AN APPROVED SOLUTION AND THROUGHLY FLUSHED OF ALL RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND CONNECTIONS INSTALLED. 17. PROVIDE SHUT-OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE -END CONNECTIONS. 18. ALL FLOOR DRAINS SWILL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 19. PVC PIPING IS NOT ALLOWED IN RETURN AIR PLENUMS. IF RETURN AIR PLENUMS ARE USED, CONTRACTOR SHALL REPLACE ALL EXISTING PVC PIPING WITH CAST IRON OR COPPER PIPING. 20. DRAINAGE SYSTEM DESIGN IS BASED ON 1/8' PER FOOT MINIMUM FALL FOR PIPES 3" OR LARGER AND 1/4' PER FOOT MINIMUM FALL FOR PIPES 2" OR SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT/ENGINEER. 21. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFFSETED TO A MINIMUM DISTANCE OF 3'-0" FROM PARRAPET WALL OR ROOF EDGE. SEE ARCHITECTURAL DRAWINGS FOR ROOF FLASHING. LEAD FLASHING WILL NOT BE ACCEPTED. 22. DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED WITH PRE -MANUFACTURED SLEEVE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 404.6.4. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. PLUMBING SPECIFICATION 1. GENERAL - MATERIAL SHALL BE NEW, UNUSED. BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBLICATIONS IN FORCE AT TIME OF BIDDING. 2. PPE AND FITTINGS - A. DRAINAGE WASTE AND VENT PIPING INCWDING: PVC DRAINAGE WASTE AND PIPING (QWV) CONFORMING TO ASTM D-2665 UNDERGROUND NO HUB CAST IRON CISPI STANDARD 301 ABOVE GROUNb AND CAST IRON HUB. PLAIN END ASTM A-74 WITH NEO- PRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN ITS PIED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR RETURN M. B. DOMESTIC WATER SUPPLY PIPING: COPPER PIPE TYPE 'L' WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM.886-78. C. CONDENSATE PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. D. STORM DRAIN PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL. WASTE AND VENT PIPING. 3. JOINTS AND METHODS OF CONNECTION: A. DWV COPPER PIPE: JOINT WITH 95-5 TIN -ANTIMONY SOLDER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. B. TYPE 'L' COPPER TUBE: JOIN WITH 95-5 TIN -ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATKNrS. C. STEEL PIPE o. THREADED JOINTS: AFTER CUTTING AND BEFORE THREADING, REAM ALL PEE AND REMOVE BURRS. MAKE JOINTS WITH JOINT COMPOUND APPLIED TO MALE THREADS ONLY. b. FLANGED JOINTS: STANDARD WEIGHT, 150 P.S.I. STEEL. WITH APPROVED RED RUBBER GASKET OR NEOPRENE RUBBER GASKET. INSTALL AS PER MANUFACTURER'S RECOMMENDATIONS. 4. UNIONS AND FLANGES: A. COPPER PIPE: BRONZE UNIONS FOR 2 INCHES AND SMALLER. FOR 2-1/2 INCHES AND LARGER USE BRONZE FLANGED CONNECTIONS 150 POUND CLASS. B. DIELECTRIC UNIONS OR FLANGES: UNIONS SHALL MEET DIMENSIONAL REQUIREMENTS AND TENSILE STRENGTH OF PIPE UNIONS IN ACCORDANCE WITH FED. SPEC. WW-U-531 E. UNIONS OR FLANGES SHALL BE SUITABLE FOR REQUIRED OPERATING PRESSURES AND TEMPERATURE CONDITIONS. UNIONS SHALL HAVE METAL CONNECTIONS ON BOTH ENDS. ENDS SHALL BE THREADED OR SOLDERED TO MATCH ADJACENT PIPING. METAL PARTS OF UNION OR FLANGED SHALL BE SEPAREATED TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. EPCO DIELECTRIC PIPE FITTINGS OR EQUIVALENT. 5. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CENJNGS OF FINISHED AREAS, 6. PIPE INSULATION: A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3 4" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL NOT WATER AND TEMPERED WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. 7. INSTANT -FLOW WATER HEATERS SHALL BE OF THE CAPACITY AND ELECTRICAL CHARACTERISTICS INDICATED ON PLANS AS MANUFACTURED BY CHRONOMITE LABORATORIES,INC. S. TRAP PRIMER SHALL BE SELF PRIMING TYPE ON COLD WATER SUPPLY LINE AS MANUFACTURED BY PRECISION PLUMBING PRODUCTS, INC. "PRIME -RITE" #PR-500. WHEN TWO OR MORE TRAPS REQUIRE PRIMING PROVIDE WITH DISTRIBUTION UNIT #DU-2. 3 OR 4 AND SUPPLY TUBE WSS-S ASSEMBLY. PROVIDE ACCESS PANEL AND INSTALL AS PER MANUFACTURER'S RECOMMENDATION.I 9. FLOOR DRAINS: AS MANUFACTURED BY JOSAM. A. FD-1: JOSAM 30000-A SERIES WITH 6"x6" SQUARE NIKALOY TOP AND 1/2w TRAP PRIMER CONNECTION. t>I PIPE W/ INSULATION NUT "VIS HAN PIPE 01 ULATION PIPE NSULATIO ADDLE SHNlD PIPE W/OUT INSULATION TEST TEE THREADEC CLEANOUI PLUMBING FIXTURE CONNECTION SCHEDULE COLD HOT SYMBOL DESCRIPTION DRAIN WATER WATER MANUFACTURER/MODEL TRIM P-1 WATER CLOSET 3" 1/2' -- AMERICAN STANDARD "CADET N' CLOSED COUPLE TANK( WITH SPEED CONNECT TANK/BOWL COUPLING (HANDICAP) .170. PIECE S OUS SYSTEMAND POUSHED CHROME TRIP LEVER. CHINA ELONGATED BOWL ANDTANK A ROLSONRE 195 OPEN FRONT SEAT WITHOUT COVER. WITH BDLT HOLE COVERS. SUPPLY: BRASS -CRAFT POLISHED CHROME CAST BRASS ANGLE SUPPLY WITH WHEEL. FIA M STOP AND SHALLOW ESCUTCHEON. P-2 LAVATORY 1 1/4" 1/2' -- AMr1ERICAN STANDARD "WHEELCHAIR FAUCET: DELTA 11 3530-LISP CHROME BASE, 12" (HANDICAP) LAVATORY" #9140.013. WHITE WIDESPREAD FAUCET, 5`SIW WITH H24-A24 WITH 12" CENTER FAUCET HOLES, CHROME LEVER HANDLES, VANDAL RESISTANT SPRAY FRONT OVERFLOW AND CONCEALED f RP5202 OUTLET 0.5 GPM AND METAL POP-UP DRAIN ARMS SUPPORT. WITH PLATED FLANGED AND STOPPER. P-TRAP: McGUIRE f8872 POLISHED CHROME CARRIER: JOSAM 17100 FLOOR -MOUNT CAST BRASS WITH WALL BEND, CLEANOUT PLUG, CONCEALED ARMS SUPPORT. SLIP NUTS AND SHALLOW ESCUTCHEON. SUPPLY: BRASS -CRAFT ANGLE SUPPLY STOP WITH LOOSE KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID CHROME COPPER CONNECTION. INSULATION: McGUIRE "PROWRAP' #PW 2000 WC SEAMLESS INSULATORS FOR OFFSET DRAIN, TRAP, TAN.PIECE, WASTE ARM AND HOT k COLD VALVES. P-3 WATER COOLER 1 1/2' 1/2" -- OASIS REF: LZS8 STAINLESS STEEL BOTTOM TOPS BARRIER -FREE ACCESS WATERWAY ARE LEAD-FREE IN MATERIALS 0 CONSTRUCTION RATED CAPACITY 8 GPH, 3.7 AMPS FLEXI-GUARD SAFETY BUBBLER. FULL LOAD , 1/4H.P. COMP. WALL CLEANOUT (NOT TO SCALE) ACCESS COVER AND FRAME FINISHED WALL SURFACE CONDENSATE TRAP DETAIL (NOT TO SCALE) AM Consulting Engineers LLC Certificate OF Authorization #9692 Jose M. Martinez, P.E. #56018 12651 South Dine HWY. Suite 209 EEL, (305) 255-1621 Miami, Florida 33156 FAX (305) 255-IM TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BOLDING CODES. TMS DRAWING IS THE SOLE PROPERTY OF JAM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF JAM CONSULTING ENGINNERS. LLC. Uj a o a�05 sr %"OF DATER : SCALE 09-21-1116 VIC DRAM STINErm rolt Eft pmwm NO: P-2 of 2