06-1796-007T
UL1479
UL2079
PLUMBING LEGEND
SYMBOL
DESCRIPTION
SANITARY WASTE PIPING
-
COLD WATER PIPING (CW)
- - - - -
SANITARY VENT PIPING
CD -
CONDENSATE DRAIN PIPING
SD
STORM DRAIN PIPING
0317-
OVERFLOW STORM DRAIN PIPING
RUL
RAIN WATER LEADER
ORUL
OVERFLOW RAIN WATER LEADER
---D4---
GATE VALVE
CHECK VALVE
"P" TRAP
tLr—
-t-+ HB
HOSE BIBS (HIS)
WATER HAMMER ARRESTOR
VTR
VENT THRU ROOF
CO I-`--
CLEAN OUT
FCO
FLUSH FLOOR CLEAN OUT
W�-
FLOOR DRAIN WITH TRAP PRIMER
COOT'
CLEAN OUT ON GRADE
FD
FLOOR DRAIN
V
VENT
TRAP PRIMER (RESEAL)
TO CLOSEST FIXTURE
Q RD
ROOF DRAIN
O ORD
OVERFLOW ROOF DRAIN
FOS
FUEL OIL SUPPLY PIPING
FOR
FUEL OIL RETURN PIPING
INOTE;
SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS
UL FIRE RESISTANCE DIRECTORY:
A. FILLS, VOIDS OR CAVITY MATERIALS (XHHW)
B. FIRESTOP DEVICES (XHJI)
1. PRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY
2. METALLIC PIPE:
A) STEEL PIPE -12- 0 (OR SMALLER) SCH.10 (OR HEAVIER) STEEL PIPE.
B) IRON PIPE -12'0 (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C) COPPER TUBING - 4-0 (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
D) COPPER PIPE - 40 (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
E) CONDUIT - 4-0 (OR SMALLER) EMT OR 6' 0 (OR SMALLER) STEEL CONDUIT.
THE ANNULAR SPACE SHALL BE MIN. 0' TO MAX 1' WITHIN THE FIRESTOP SYSTEM.
3. TREMSTOPIA- MIN 1/2' THICKNESS OF SEALANT APPLIED WITHIN OPENING. MIN 3/8' CANT BEAD OF
SEALANT TO BE APPLIED AT AREAS OF POINT CONTACT.
'TREMCO' MODEL: TREMSTOP U1 FOR 1 OR 2 HOUR FIRE
RATED PENETRATION FOR SINGLE METALLIC PIPE THRU
GYPSUM WALL
1. PRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY
2. PLASTIC PIPE - NOM. 4.0 (OR SMALLER) SCH. 40 PVC PIPE FOR USE INCLOSED OR OPEN PIPING
SYSTEMS. SEE TABLE BELOW FOR REQUIRED ANNULAR SPACE
3. TREMSTOP WS - INTUMESCENT WRAP STRIP, CONTINUOUSLY WRAPPED AROUND OUTER
CIRCUMFERENCE OF THE PIPE. SEE TABLE BELOW FOR MIN. WRAPS REQUIRED.
PIPE DIAM. ANG. SPACE # OF WRAPS
2 3118 3
3 Ila 4
4 1/8 6
4. TREMSTOP MCR - PREFABRICATED STEEL COLLAR WRAPPED OVER THE WRAP STRIPS (ITEM 3) AND
MECHANICALLY FASTENED TO BOTH SIDES OF WALL ASSEMBLY.
TREMSTOP 1A OR TREMSTOP ACRYLIC (OPTIONAL) - MIN 1W BEAD OF SEALANT APPLIED AT THE
5. WALLBOARDIDEVICE AND DEVICEIPIPE INTERFACES.
NOTE: TREMSTOP D CAN BE USED IN PLACE OF TREMSTOP WS AND TREMSTOP MCR.
'TREMCO' MODEL: TREMSTOP D FOR 2 HOUR FIRE
RATED PENETRATION FOR SINGLE PLASTIC PIPE THRU
GYPSUM WALL
FIRE STOPPING DETAIL
N.T.S.
WATER HAMMEL—q
ARRESTOR (TY
A �
/2"
N.T.S.
NIN
/`F"'\ FLW*0015 ING FLOOR PLAN
F3/4'
1/2=
CONNECT NEW 1"
CW LINE TO EXIST.
VERIFY EXACT LOCATION
ON SITE.
1 EXIST. 3' CW LINE
TO REMAIN
'TIC WATER PIPI
IN
11411 = 11-011
r�
EXIST-� >
2" VENT UP IC EXIST. 4" SAN.
LINE. VERIFY
•� ` EXACT LOCATION
ON SITE
nn P,1 _ rZ
JAM Consulting Engineers LLC
Certificate OF Authorization 19692
lose M. Martinez, P.E. F56018
12651 South Aide HWY. Suite 209 T& (305) 255-1621
Miami, Florida 33156 FAX (305) 29—IM
TO THE BEST OF MY KNOWA.EDCE, THE PLANS AND SPECIFICATIONS SUBMITTED
HEREWATH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE
APPLICABLE BUILDING CODES THIS DRAWING IS THE SOLE PROPERTY OF
'JAM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE
REPRODUCED IN WWCLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION
OF JAM CONSULTING ENGINNERS, LLC.
� Q
AJ f>`
0
�Q a�
N
� W
m
A
i
�-
mr
LU
m r
a �-
> W
�I
a
DATE : •GALE
1/4' - T
DATE >>ytJMETM IP= 11111110
DI vmw NO:
P-1 of 2