06-1796-004GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE, FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND STANDARDS. 2. a) THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS AND BOXES REQUIRED TO MAKE A COMPLETE NEAT INSTALLATION IN ACCORDANCE WITH N.E.C. b) WHEN CONFLICTS ARISE IN LOCATIONS WIRING DEVICES, ELECTRICAL EQUIPMENT, DISCONNECTS, PANELBOARDS, ETC. DUE TO FIELD CONDITION OR IMPROPER FIELD COORDINATION CONTRACTOR SHALL BRING IT TO THE A/E'S ATTENTION AND AT NO EXTRA COST RELOCATE, AND OR EXTEND WITHIN A REASONABLE DISTANCE SUCH ITEM WHICH IS IN CONFLICT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING LOCATION OF ALLCOMPONENTS PRIOR TO ROUGH IN WITH ALL TRADES NO EXTRAS WILL BE ALLOWED FOR FAILURE TO DO SO. 3. THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING / BIDDING WORK. 4. THE CONTRACTOR SHALL SATISFACTORILY REPAIR IREPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 5. APPROVAL SHALL BE OBTAINED FROM A STRUCTURAL ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRUCTUALSUPPORT MEMBER. 6. ALL DEVICE BOXES SHALL BE INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN/NOTED OTHERWISE. 7. INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEM AS SHOWN/NOTED ON THESE DRAWINGS AND PER OTHER APPUCBLE DRAWINGS / INSTRUCTIONS. SEE AIR CONDITIONING DRAWING. 8. ALL MATERIAL REMOVED SHALL BE SISPOSED OF AS DIRECTED BY OWNER. 9. WIRE SIZE SHALL BE # 12 THHN / THWN UNLESS OTHERWISE NOTED ON PLANS. 10. ALL SHALL BE THWN. 11. ALL CONDUCTORS SHALL BE COPPER RUN IN METALLIC CONDUIT. 12. ALL CONDUCTORS SHALL BE RUN IN CONDUIT METALLIC TYPE). IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN QUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250-122 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 13. ALL MATERIALS SHALL BE U.L APPROVED. 14. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED. 15. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 16. ALL NON POWER RELATED WIRING I N CEILING AIR CONDITIONING PLENUM RUNNING WITHOUT CONDUIT SHALL BE TEFLON COATED CLASSIFIED FOR USE IN PLENUMS. 17. PROVIDE TRAPEZE HANGER AS ASSEMBLE FOR PLENUM COMMUNICATION CABLE WITH 3 8" DIAMETER. THREADED ROD AND CHANNEL ASSEMBLY TO SUPPORT CABLE BUNDLES EVERY 4 FTO.C. (MA(IMUM CABLES SHALL NOT LIE ON TOP OF CEILING TILE OR LUMINARIES). 18. LIGHT SWITCHES OPERATING CIRCUIT OTHER THAN 120 V SHALL NOT BE GANGED IN SAME BOX UNLESS SWITCHES ARE CONNECTED TO SAME CIRCUIT. 19, ALL BRANCH CIRCUITS TO HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER N.E.C. 250.122. 20. ALL EMPTY CONDUITS TO BE PROVIDED WITH NYLON PULL STRINGS. 21. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 22. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DRAWING. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 23. CONTACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUIT WIRING AND RACEWAY AS SHOWN ON THE AIR CONDITIONING DRAWING OR SPECIFICATIONS. IF AIR CONDITIONG DRAWING REFER TO MANUFACTURER ALL REQUIREMENT AND INCLUDE ALL RELATED WORK IN HAS CONTACT. 24. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. 25. RISERS ARE DIAGRAMMATIC ONLY. THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 26. THIS DRAWING IS A GUIDE FOR THE ELECTRICAL INSTALLTION. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 27. ALL CABLES SHALL BE RUN WITBUT SPLICES EXCEPT IF OTHERWISE INDICATED. 28. ALL PULL AND JUNCTION BOXES SHAL BE ACCESSIBLE AT ALL TIMES. 29. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 30. ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 31. BRANCH CIRCUIT BREAKERS SHALL BE OF THE BOIHN TYPE. PLUG IN CIRCUIT BREAKERS WILL NOT BE ACCEPTED. 32. ALL RACEWAY ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR CODED AS FOLLOWS: 120/208 V SYSTEM PHHAASSE B' BLACK PHASE 'C' BLUE NEUT D WHIGRETE 33. SUBMIT DETAILED LAYOUT OF ALL ELECTRICAL ROOMS WITH EQUIPMENT REQUIRING ELECTRICAL SERVICE, LAYOUT SHALL SHOW PROPOSED LOCATION OF ELECTRICAL SERVICE ITEMS SUCH AS DISCONNECTS, RELAY, PANELBOARDS, ETC. AND DIMENSIONS SHOWING CODE CLEARANCES TO ADJACENT SURFACES. 34. ALL ROUGH IN DIMENSIONS ARE TO CENTER LINE OF DEVICE UNLESS OTHERWISE NOTED. 35. ALL PULL BOXES, HAND HOLES AND MAN HOLES TO HAVE COVER PLATE BOLTED TO FRAME AND BONDED TO THE EQUIPMENT GROUND SYSTEM. 36. CONTRACTOR SHALL INCLUDE IN HIS BID ALL COST RELATED TO THE WIND LOAD COMPLIANCE, THE CLRRFICATTON OF THE EXTERIOR POLE/LUMINARY ASSEMBLIES BY A STRUCTURAL ENGINEER. 37. ALL CONDUCTOR SPLICES IN EXTERIOR LOCATED JUNCTION PULL BOXES EXPOSED TO THE WEATHER TO BE WEATHER SEALED BY USING AN APPROVED METHOD SUCH AS 3M, SCOTHLOCK CONNECTOR EPDXY SEAUNG, PACK OR SIMILAR. ELECTRICAL SYMBOL LEGEND USE THOSE THAT APPLY CEILING MOUNTED 2' X 4' FLUORESCENT LIGHT FIXTURE. L� CEIUNG OR WALL MOUNTED 1' X 4' FLUORESCENT LIGHT FIXTURE. 0 COMPACT FLUORESCENT DOWNUGHT FIXTURE. 1-0 WALL LIGHT WALL OR CEILING MOUNTED EXIT LIGHT FIXTURE. ARROWS, NUMBER OF FACES AND MOUNTING AS REQUIRED TO INDICATE A CLEAN PAHT TO EXIT S 120/277 V., 20 AMP., SINGLE POLE LIGHT SWITCH. S 3 120/277 V., 20 AMP., THREE WAY SWITCH. SM MANUAL MOTOR SWITCH. o f� ELECTRICAL PANEL Eli DISCONNECT SWITCH. SIZED PER EQUIPMENT NAMEPLATE ® MAGNETIC MOTOR STARTER, PROVIDED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. ELECTRIC MOTOR. -^•�•AA EQUIPMENT CONNECTION WITH FLEXIBLE CONDUIT. 20A., 120 V., QUADRUPLEX RECEPTACLE, TWO DUPLEX IN TWO BOX. 18" A.F.F. OR AS DIRECTED BY ARCHITECT. 20 A., 120., V., DUPLEX RECEPTACLE, GROUNDING TYPE, U.O.N. MOUNTED 18" A.F.F. OR AS DIRECTED BY ARCHITECT. Q �-G CEIUNG OR WALL MOUNTED JUNCTION BOX. CONDUIT RUNNING UNDERGROUND OR UNDER CONCRETE SLAB. TELEPHONE OUTLET 0 +18" A.F.F. OR AS DIRECTED BY ARCHITECT. EXISTING ELECTRICAL ROOM #4 EXIST'G TENANT GUTTER EXISTING 3P-1200A M.C.B. -,,, F _E - :SS-- 0 1 0 c NEW 4 #2 & 1 J8(G) IN EXISTING 2" C 100 NEW MAIN DISCONNECT EXIST'G 3/0 (G) I I 3 100 I 100K AIC NEW FPL APPROVED I I NEW 4 12 & 1 #8(G) IN NEW TENANT NEW I ____'*'�IME CLOCK PNL A L✓ EXISTING 2 C I - - EXIST'G 3 SETS OF (3 #600 MCM & -1 #4/0 (N) & 1 J2/0 (G)) IN 4" C TO EXIST. 3P-1200A IN DIST. BOARD. ELECTRICAL RISER DIAGRAM N.T.S. EXTEND EXIST'G 2' C TO NEW PANEL LOCATION. TYPE: SQ'D NQOD PANEL 9A" (22K AIC) 100A M.L.00/208V, 30, 4W MTG: FLUSH MOUNTED LOAD: 24.3 KVA/360V = 67.5 A CU BUS I GND BUS LOAD COND. WIRE TRIP POLE DESCRIPTION CKT No. CKT No. DESCRIPTION POLE TRIP WIRE COND. LOAD 11019 1-1/4" 4 70 AHU (*) 1 2 CU (*) 2 40 8 3/4" 4285 -- -- -- �_z 3 4 -- -- -- 800 1/2" 12 20 1 LIGHTS 5 6 DF 1 20 12 1/2' 800 600 LIGHTS 7 8 BATH REC. 500 200 ROOF REC. 9 10 RECEPTACLES 720 720 RECEPTACLES 11 12 1600 DEDICATED RECS. 13 14 1600 15 16 SIGN (*) 1 20 -- -- 1200 1600 17 18 SHOWCASE -- -- 1500 SPACE 19 20 SPARE -- -- -- -- -- -- -- -- 21 22 -- -- -- -- -- -- -- -- 23 24 (*) ON TIME CLOCK 7'R�Elll CO F-rating = 2 Hr. T-rating = 0 Hr, 111 4 rA N'oncz (1) Pre -Rated Concrete Floors or Block Walls = Min, 4-1/2' thick, with annular space range of 0' to 7/8'. ® Conduit - Nom, 4' dla, (or smatter) steel conduit or EMT. 0 Packing Material - Mineral wool (min, 4 pcf) compressed min, 507and installed Into the opening to obtain min, 4' thickness, ® TREMC❑ # TREMstop Acrylic - Min, 1/2' sealant applied within annulus, and a minimum 1/4' sealant' applied at point contacts at the floor surface for flooi or both surfaces for watts, F-rating = 1 and 2 Hr. T-rating - ^ UL # WL FIFE ALARM NOTES 1. FIRE ALARM SYSTEM SHALL BE U.L LISTED NFPA 72 APPROVED. 2. UPON ACTIVATION OF FIRE ALARM SYSTEM BY MANUAL STATION, THE FOLLOWING SHALL TAKE PLACE: A ENERGIZE ALARM SIGNALING DEVICES B SOUND AUDIBLE ALARMS AND FLASH VISUAL SIGNALS C ALERT LOCAL FIRE DEPARTMENT OR PROPIETARY SYSTEM D CAUSE ZONE IN ALARM TO BE DISPLAYED ON THE ANNUNCIATOR 3. ALL WIRING AND CONDUIT SIZE SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION, AND REQUIREMENTS OF NEC, LOCAL CODES AND NFPA IN NO CASE. SHALL THE WIRING BE SMALLER THAN #16 F.P.L CU IN. 3/4' CONDUIT 4. ALL CONDUCTORS SHALL BE COOPER AND SHALL BE SIZED FOR A MAXIMUM LOSS OF 1 dB. MINIMUM WIRE SIZE SHALL BE AS REQUIRED BY MANUFACTURER IN NO CASE. SHALL THE WIRING BE SMALLER THAN #16 F.P.L. CU IN. 3/4" CONDUIT 5. QUANTITY OF WIRES PER DEVICES SHALL BE AS REQUIRED BY MANUFACTURER. 6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING FIRE ALARM SIGNED & SEALED PERMIT DRAWINGS. TREI�1,�1 C© ® 1 or 2 - hour fire rated gypsum wallboard/stud assembly (angular space range, min, 1/4' to max. 5/8') ® Conduit - 4' diam,(or smatter) EMT or rigid steel © TREMCO # FIRE -SHIELD - min. 1/2' thickness of sealant Installed within opening with a min. of 1/4' crown around ground the penetrating Item applied flush with both side of wall assembly, RRE ALARM LEGEND ® PHOTOELECTRIC SMOKE DETECTOR nF PULL STATION QS 4 ADA SPEAKER/STROBE © ADA STROBE LIGHT NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE WITH EXISTING FIRE ALARM SYSTEM .�rs�`S'fiwl��ft������: � G-1 U-32.0t0 r` 72 n rtl . r Ed, 0P+. jjr<-o,G.>�q'a V • aDATF- ACCESSIBLE JUNCTION BRANCH CIRCUIT BOX w :. d ID 3/8' FLEXIBLE CONDUIT. NREXT TOPFIXTURE MAX 6FT. AS PER NEC 348.3 SLAB LIGHTING FIXTURE -� �- FINISHED CEILING RECESSED FLORESCENT LT. FIXTURE CONNECTION DETAIL N.T.S. NOTES: 1.- ALL RECESSED LIGHT FIXTURES ARE TO BE CONNECTED AS DETAILED. 2.- ALL JUNCTION BOXES ARE TO BE READILY ACCESIBLE. 3.- PROVIDE FIRE PROOF TENT AS REQUIRED TO KEEP UL CEILING RATING. U. �. • , V,, ' 4p ', AM Consulting Engineers LLC Certificate OF Authorization 19692 Jose M. Martinez, P.E. IM18 12651 South Dixie HWY. Suite 209 TEL. (305) 255-1621 Miami, Florida 33156 FAX (305) 29-17M TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF 'JMM CONSULTING ENGINEERS LLC' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHCUT THE EXPRESS WRITTEN PERMISSION OF JAM CONSULTINO ENGINNER% LLC. Uj 1 .1 Q O� a� oa �y Q E.. s D AIM : :MALE 00-21-10 11W -I DIA78 alifrM FOR EM DRAwNH ND : E-2 of 2